Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹22.9 L+₹1.4 L (6.32%)Rejected-AOC | L2 | Rejected-AOC Other Than Lowest Tenderer | |
| 3 | L3₹22.9 L+₹1.4 L (6.41%)Rejected-AOC | L3 | Rejected-AOC Other Than Lowest Tenderer | |
| 4 | L4₹23.3 L+₹1.8 L (8.18%)Rejected-AOC | L4 | Rejected-AOC Other Than Lowest Tenderer |
Tender Value
₹24.6 L
EMD Value
₹49,200
Closing Date
7 Sept 2020, 6:00 pmClosed
GE 874 EWS C/o 56 APO
GE 874 EWS C/o 56 APO
REPAIR MAINT OF CENTRAL HEATING SYSTEM AND REPAIR OF INTERNAL WIRING INCLUDING FIXTURE/ FITTING AND SUMMER COLLING APPLIANCES AT ZANGLI, DRUGMULLA AND CHAKKIGAM UNDER GE 874 EWS
2020_MES_367858_1
GE 874/EWS-16/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
KUPWARA
Class E Category b i
5 documents required · 5 mandatory
₹500
GE 874 EWS C/o 56 APO
₹49,200
Yes
2 Mar 2021
10 Aug 2020
8 Sept 2020
10 Aug 2020
7 Sept 2020
24 Aug 2020
11 Aug 2020 - 18 Aug 2020
Amount
Attending complaints for day to day/daily complaints by employed skilled staff, checking the serviceability of fan coil units and Air Conditioners of any capacity for having continous serviceability of FCU/ AC for any number of times as desired by Engr-in-charge incl replacement of minor spare parts like gasket, Electronoc boards and components, teflon tape, flare nut, tightening of any loose glycol connections, shifting FCU/ AC from one place to another place if required, heating up the freezed glycol line anywhere about the premises to have continous flow of glycol fluid, repairing the insulation pipes of any size by providing shallow pipe/ GI pipe as deemed fit for failing the insulation of pipe line,tightening the loose electrical connections as related with FCU/ AC,heating system, cleaning the air filter incl radiator of FCU to the entire satisfaction of Engr-in-charge all as directed. (i) Attending complaints of different nature in a single day in entire Grn incl ops room and MI room will be considered one job. (ii)Any replacement of major parts will be measured and paid seperately under respective items of Sch A. (iii) Any nature of complaints related to FCU, radiator,bursting /cracking/leakage MS pipe lines, replacement of valves etc will be completed round the clock by suitable tradesman(welder with suitable T&P incl potable heating materials, skilled mech of CHS,plumber/fitter with helper, supervisor). (iv) Job slip will be maintained by the contractor supervisor under the supervision of JE E/M. (v) Any delay, of more than 48 hrs from intimation, in attending complaints will be reported to higher authorities and suitable penalities will be incurred from contractor( Rs 1000/- per job)
Disconnecting all electrical connection from central heating burner of make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and dismantling it from inlet opening central heating plant and set aside for repair and maintenance , removing wornout/defective spare parts and the replacement of following parts including servicing and testing on completion, complete all as specified. (Note :- Cost of spares/parts to be replaced will be measured and paid seprately as supply only under respective items mentioned here-in-below).
Supply only Ignition Transformer suitable for burner make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make - Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only oil flow sequence controller suitable for burner make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make - Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only Fuel feed pump suitable for burner make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make - Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only Photocell suitable for burnersuitable for burner make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make - Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only Nozzle suitable for burner make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make - Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only Solenoid valves suitable for burner make Ecoflame model No 83141558 25-10 minor 30.1 TLD min 15Kg/hr and max 28 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make - Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Disconnecting all electrical connection from central heating burner of makeEcoflame model No 870114/2 48-05 minor 14 TDC min 9 Kg/hr and max 14.5 Kg/hr IP-40 and dismantling it from inlet opening central heating plant and set aside for repair and maintanance , removing wornout/defective spare parts and the replacement of following parts including servicing and testing on completion, complete all as specified. (Note :- Cost of spares/parts to be replaced will be measured and paid seprately as supply only under respective items mentioned here-in-below).
Supply only Ignition Transformer suitable for burner make Ecoflame model No 870114/2 48-05 minor 14 TDC min 9 Kg/hr and max 14.5 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss.
Supply only oil flow sequence controller suitable for burner make Ecoflame Model Minor-14 DTC Max pressure 2 bar)and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss.
Supply only Fuel feed pump suitable for burner make Ecoflame model No 870114/2 48-05 minor 14 TDC min 9 Kg/hr and max 14.5 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only Photocell suitable for burner make Ecoflame Model Minor-14 DTC Max pressure 2 bar)and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss .
Supply only Nozzle suitable for burner make Ecoflame model No 870114/2 48-05 minor 14 TDC min 9 Kg/hr and max 14.5 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss,
Supply only Solenoid valves suitable for burner make Ecoflame model No 870114/2 48-05 minor 14 TDC min 9 Kg/hr and max 14.5 Kg/hr IP-40 and heating plant model No.WHW-200 capacity 200000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss,
Disconnecting all electrical connection from boiler and dismantling burner of make Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 from inlet opening central heating plant and set aside for repair and maintenance , removing wornout/defective spare parts and the replacement of following parts including servicing and testing on completion, complete all as specified. (Note :- Cost of spares/parts to be replaced will be measured and paid seprately as supply only under respective items mentioned here-in-below).
Supply only Ignition Transformer suitable for burners Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 and heating plant model No.WHW-100 capacity 100000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss.
Supply only oil flow sequence controller suitable for burners Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss.
Supply only Fuel feed pump suitable for burners Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 and heating plant model No.WHW-100 capacity 100000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss.
Supply only Photocell suitable for burners Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss.
Supply only Nozzle suitable for burners Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 and heating plant model No.WHW-100 capacity 100000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Supply only Solenoid valves suitable for burners Ecoflame Model 011/32 37-09 Minor 12.1 TL (L+S) min 6 Kg/hr and max 12 Kg/hr IP-40 bar and heating plant model No.WHW-100 capacity 100000 Kcal/hr Make Ecoflame/ Suntec/ Siemen/CE/ Danfoss
Dismantling boiler of capacity 200000/ 100000 Kcal/hr by disconnecting all electric connections and unscrewing glycol tubing to isolate combustion chamber of boiler . Opening the inlet cover of Boiler by unscrewing the nut bolt and taking out the unserviceable coil made out of MS from the chamber with engagement of Tripod and chain pulley wihtout damaging internal chamber including cleaning of carbon content(scaling) to max clean with the help of heavy duty compressor including disposal of waste outside of cantonment area and replacement of damage parts of boiler complete all as directed by Engr-in-charge. (Note :- Cost of spares/parts to be replaced will be measured and paid seprately as supply only under respective items mentioned here-in-below).
Supply only burnt fire crete matti all as specified
Supply only asbstos foam all as specified
Supply only Inner glycol tubing of all as specified
Supply only Inner Piping Glass of all as specified
Supply and fixing of Asbestos Rope on Exhaust of bioler central heating plant up to wall all as specified and directed.
Material and labour for replacment of pressure guage suitable for heating plant model No.WHW-200 and WHW-100 as per sample all as specified
Material and labour for replacment of Transperent Fuel Filter suitable for heating plant model No.WHW-200 and WHW-100 as per sample all as specified
Material and labour for replacment Fuel pipe for fuel pump suitable for heating plant model No.WHW-200 and WHW-100 as per sample all as specified
Material and labour for replacment Fuel tee suitable for heating plant model No.WHW-200 and WHW-100 as per sample all as specified
Supply and fix butterfly gate valve 100 mm dia having nitrate seat and epoxy coated disc CI with hand leaver pressure rating PN 1.0 complete all as specified and as directed. Make - C&R/ kirloskar/ Zoloto.
Supply and fix air release valve (ARV) to automatically release trapped air from a heating system 25mm dia. complete all as specified and as directed. Make - C&R/ kirloskar/ Zoloto.
Disconnecting all electrical connections from blower and motor of Air handling unit at 428 FD HOSP (Make thermax) blower compartment incl dismantling of all pre filters, microfilters,aluminium perforated sheet over glass fibre wool panels , blowermotor incl connecting after repair / replacements of following parts including servicing and testing on completion, all as specified and directed by Eng-in-charge. (Note :- Cost of spares/parts to be replaced will be measured and paid seprately as supply only under respective items mentioned here-in-below).
Supply only prefilters having aluminium frame as per sample
Supply only Micro filters having aluminium frame as per sample
Supply only aluminium perforated sheet panel over 50 mm thick glass fibre wool as per sample
Supply only centre bearings for blower shaft incl CI housing all as per sample
Supply only v belts size B77 all as specified
Supply only foam for AHU Shatters all as specified
Repair of rediator cheaking for leakage of copper tubes and discaling of Glycol tubing including welding bleasing as requaired at site
Cleaning the chimney of heating plants from inside with wire brushes and removing away all carbon deposited and painting the outer surface of the chimney with two coats of heat proof black paint after preparing the surface for repainting complete all as directed.
Supply and fixing in replacement decorative wall mounted fan coil units of capacity 4500 Kcal/Hr CFM 470 complete with grill, ESB casing 3 speed motor, wall mounting brackets inlet out let mainfold all as directed and specified by Engr-in-Charge. Make - Western Model No WFC-4 or equivalent in Caryaire/ zeco/ airflow.
Repair of damages in CHS pipeline system with SMAW/ GMAW/ GTAW welding work, including electrodes/ filler material, for one damage of upto 2 meters long on the pipeline complete all as directed.
Supply and laying,connecting , fixing and testing in replacement of 3 layer poly propylene random copolymer composit pipes 25mm bore OD pipe conforming to PN1.6 complete with fittings duly insulated with 13mm thick closed cell elastomeric insulation 30 to 40 Kg/m3 density all as directed and specified by Engr-in-Charge.
Supply and laying,connecting , fixing and testing in replacement of 3 layer poly propylene random copolymer composit pipes 20mm bore OD pipe conforming to PN1.6 complete with fittings duly insulated with 13mm thick closed cell elastomeric insulation 30 to 40 Kg/m3 density all as directed and specified by Engr-in-Charge.
Supply and fixing in replacement aluminium cladding over MS pipe and AHU duct with 24 guage aluminium sheet incl over lapping,screwing and well finishing complete all as specified
Supply & fixing in replacement of gun metal steam stop valve of 25mm bore screwed on both ends. Make Sant,CIM,Zoloto
Supply & fixing in replacemnet of gun metal steam stop valve of 20mm bore screwed on both ends. Make Sant,CIM,Zoloto
Supply & fixing in replacement of gun metal steam stop valve of 15mm bore screwed on both ends. Make Sant,CIM,Zoloto
Supply and fixing in replacement Heavy duty wiremesh bounded fuel pipe with flare nut both ends 600 mm length as per sample complete all as directed by Engr-in-charge.
Supply and fixing in replacement fuel filter element as per sample complete all as directed by Engr-in-charge.
Supply and fixing in replacement polyurethane pipe for hot water flow suitably connecting at inlet and outlet of FCU of size 16mmx12mm capable of of taking over 10 bar pressure ISI marked and temp 85 deg celsius all as specified and directed. Make K N K or as approved by GE.
Supply and fixing in replacement Nitrile foam insulation over CHS MS ERW heating pipes, of size 3/4" ID X 1/2 " TK ( 19 mm x 13mm ) all as specified and directed Make Superlon,Sant
Supply and fixing in replacement Nitrile foam insulation over CHS MS ERW heating pipes, of size 7/8" ID X 1/2 " TK ( 22 mm x 13mm ) all as specified and directed Make Superlon,Sant
Supply and fixing in replacement Nitrile foam insulation over CHS MS ERW heating pipes, of size 4" ID X 3/4 " TK ( 102 mm x 19mm ) all as specified and directed Make Superlon,Sant
Supply and fixing in replacement Nitrile foam insulation over CHS MS ERW heating pipes, of size 3 1/8" ID X 1/2 " TK ( 80 mm x 13mm ) all as specified and directed Make Superlon,Sant
Repair and maintenance of wall mounted type Fan coil unit ( Inner Unit complete) of make Western modle - WFC-04/ WFC-3000 after disconnecting electric connections including servicing and washing of condensor and replacement of following parts with existing make (Capacity upto 4500Kcal/Hr) and specifications as approved by the Engineer-in-charge: Note :- The cost of labour for repair and replacement of worn out/defective spare parts included in this item and parts to be replaced shall be measured and paid separetely and minor part included with this like tap roll etc.
Supply, Installation, Commissioning and testing of Blower motor for FCU of make Western model No WFC-04/ WFC-3000
Supply, Installation, Commissioning and testing of PCB for FCU of make Western model No WFC-04/ WFC-3000 and for Air Conditioner of capacity upto 2 ton
Supply, Installation, Commissioning and testing of Display Board for FCU of make Western model No WFC-04/ WFC-3000
Supply, Installation, Commissioning and testing of Nozzle Sets for inner units for FCU of make Western model No WFC-04/ WFC-3000, as per sample.
Supply, Installation, Commissioning and testing of Pressure Valve for inner units for FCU of make Western model No WFC-04/ WFC-3000, as per sample.
Supply, Installation, Commissioning and testing of Rubber Rings for for stopage of leakage in inner units pipe for FCU of make Western model No WFC-04/ WFC-3000, as per sample.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed for fixing of inclusive of one primer coat, one under coat and one finishing coat of paint.complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specifiecd and directed.
Points wiring for one light point/fan point/socket controlled by one switch with 1.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/fan point including Accessories and providing PVC boxes for mounting switches, sockets, fan regulators, provn for modular terressa plate, irene srtrips No of modules as required on site or as direcdted by Engr-in- charge.
Point wiring for 5 pin socket outlet 5 Amps on the same board controlled by one switch with 1.5 sqmm PVC FR insulted un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FR insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) including Accessories and providing PVC boxes for mounting switches, sockets, fan regulators, provn for modular terressa plate, irene srtrips No of modules as required on site or as direcdted by Engr-in- charge. specified.
Point wiring for 5 pin socket outlet 15 Amps on the independent board controlled by one switch with 2.5 sqmm PVC FR insulted un-sheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC FR insulted un-sheathed copper conductor single core multi stranded flexible cable as earth lead (using colour coding) in and including cable 1100 volts grade including casing and capping (ISI marked) including Accessories and providing PVC boxes for mounting switches, sockets, fan regulators, provn for modular terressa plate, irene srtrips No of modules as required on site or as direcdted by Engr-in- charge.
Switch piano flush button single pole, one way 5 amps complete all as specified and directed.
Socket outlet multi 5 pins 5 amp, complete all as specified and directed.
Switch socket combination 2 in 1, 5A flush type complete all as specified and directed. .
Switch piano flush button single pole, one way 15amps complete all as specified and directed.
Socket outlet 2 in 1, 6 pins 15 amp, complete all as specified and directed.
Switch socket combination 3 pin 16A, flush type complete all as specified and directed. .
Ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed.
Lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
Supply and Fix only stepped type electronic fan regulator 1 module in white colour complete all as specified and directed. .
S&F Modular switch 1 way 6A, 1 module, flush button single pole, one way, wooden pattern, complete as directed and specified by engineer in charge. complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 module, flush button single pole, one way, wooden pattern, complete as directed and specified by engineer in charge. complete all as specified and directed.
S&F modular socket outlet 2 in 1, 6 pins 6A and 16A, combined module, wooden pattern, complete as directed and specified by engineer in charge.
S&F modular white cover plate with frame, 1 to 8 module, wooden pattern, complete as directed and specified by engineer in charge.
Sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 12 way incl blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/ flush to the wall or niche complete all as specified and directed.
Sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 8 way incl blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/ flush to the wall or niche complete all as specified and directed.
MCB single pole & neutral 6 to 32 Amps 230 Volts'C' series, 10 KA complete all as specified and directed.
MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, all as specified and as directed by Engr -in-Charge.
Submain wiring using two single core PVC insulated cables with copper conductor(FRLS) of size 6 sq.mm (nominal area) & drawn into medium grade PVC conduit 25 mm dia with all fittings and accessories fixed concealed including chase cutting in brick/stone masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface including provision of 4 sq.mm copper conductor(FRLS) PVC insulated earth wire complete all as specified. Note:- 2 Run of 6sqmm + 1 Run of 4sqmm +1Run of PVC conduit shall be measured as 1 RM.
Submain wiring using two single core PVC insulated cables with copper conductor(FRLS) of size 4 sq.mm (nominal area) & drawn into medium grade PVC conduit 25 mm dia with all fittings and accessories fixed concealed including chase cutting in brick/stone masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface including provision of 2.5 sq.mm copper conductor(FRLS) PVC insulated earth wire complete all as specified. Note:- 2 Run of 4sqmm + 1 Run of 2.5sqmm +1Run of PVC conduit shall be measured as 1 RM.
Submain wiring using two single core PVC insulated cables with copper conductor(FRLS) of size 2.5 sq.mm (nominal area) & drawn into medium grade PVC conduit 25 mm dia with all fittings and accessories fixed concealed including chase cutting in brick/stone masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface including provision of 1.5 sq.mm copper conductor(FRLS) PVC insulated earth wire complete all as specified. Note:- 2 Run of 2.5sqmm + 1 Run of 1.5sqmm +1Run of PVC conduit shall be measured as 1 RM.
S&F Bed side designer lamp, 5 watts, with designer ceramic or designer glassware cover, enamelled bronze base, with LED lamp, including all wiring and switches required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body, complete all as specified and directed by Eng-in-charge. Make - C&S/Crabtree/Standard or as approved by Eng-in-charge.
Supply Only Table lamp, designer hanging type, 10 watts, with designer ceramic or designer glassware dome of 600mm, enamelled bronze/ stainless steel base, with LED lamp, including necessary wiring and accessories required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body, complete all as specified and directed by Eng-in-charge. Make - C&S/Crabtree/Standard or as approved by Eng-in-charge.
S&F Bathroom mirror lamp, 10 watts, with designer glass cover, enamelled bronze base, with LED lamp, including necessary wiring and accessories required, PVC/ polycarbonate, isolated body, complete all as specified and directed by Eng-in-charge. Make - C&S/Crabtree/Standard or as approved by Eng-in-charge.
S&F Garden lamp, 10 watts, with 90 cm tall stem, designer ceramic or designer glassware cover, enamelled bronze/ designer steel/ designer cast iron rims and stem, with LED lamp, including all wiring and switches required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body, complete all as specified and directed by Eng-in-charge. Make - C&S/Crabtree/Standard or as approved by Eng-in-charge.
S&F Bathroom lamp, 10 watts, PIR sensor based, water resistant upto IP65, with designer ceramic or designer glassware cover, enamelled bronze base, with LED lamp, including all wiring and switches required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body, complete all as specified and directed by Eng-in-charge.
PIR Sensor based automatic switch, 220V, 6A, installed in plastic casing, coverage of 250 sq ft, timer programmable, complete all as specified and directed by Eng-in-charge. Make - C&S/Crabtree/Standard/Anchor or as approved by Eng-in-charge.
Taking down old unserviceable FTL/Bulk Head and S&F LED Bulk Head, 6Watts IP55 in engineering plastic housing with clear prismatic diffuser. including replacment of old US ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body. Make of light fitting - C&S Model No. CG80IB6WLED or equivalent in Phillips/ Wipro. Make of ceiling rose : Leader/ Cona/Anchor.
Supply and fixing recess mounting Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling.36 watts suitable for Armstrong/Grid ceiling compatible for Analog / DALI Dimming.Fixture size in mm (LxWxH) 595x595x65.Make Havells Cat No of fitting- VENUSNEOHE2X2PLR18-42WLED830MOD and Cat Part No of Driver LEDDRIVER36V36WS or equailent of philips/ wipro.
M&L rewinding of ceiling fan with super copper enamelled wire with suitable gauge, varnishing, oiling and greasing of any make of size 1200 /1400 mm sweep by dismantling its parts, capacitor by replacing petty items such as split pins,clamps, nuts & bolts, bearing & washer both end of down rod, cleaning of fan body and its blade by cleaning agent, assembling and connecting testing all as specified and as directed by Engr-in-Charge.
Painting of ceiling/ exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
M&L rewinding of exhaust fan with super copper enamelled wire with suitable gauge, varnishing, oiling and greasing of any make of size 450 mm sweep by dismantling its parts, capacitor 4 Mfd by replacing petty items such as nuts & bolts,bearing & washers, cleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting and testing Complete all as specified and directed.
Supply and fixing ball bearing suitable for Ceiling and exhaust fan of any sweep and make complete all as specified and directed.
Supply and fixing gun metal bush suitable for any sweep fan of any make complete all as specified and directed..
Supply and Replacement of unsv heating elemant with new one capacity of 1500 Watts (triangle type) for 25 Ltr geysers.
Supply and Replacement of unsv heating elemant with new one capacity of 2000 Watts for 25 Ltr geyser(triangle type).
Supply only of unsv heating elemant with new one capacity of 3000 Watts for 225 Ltr geyser.
Repair/Replacement of Thermostat 7''/9" suitable for 25/50 ltrs capacity water geyser with automatic thermal cutout fixed in repair and including testing, complete all specified and directed.
Repair/Replacement of copper Geyser Assembly with rubber packing for 25/50 ltrs capacity water geyser with automatic thermal cutout fixed in repair and including testing, complete all as specified.
S & F and testing of blower motor inverse type as per required at site compatible with inverter split type AC of Make voltas
S & F and testing of compressor for split type air conditioner of capcity 1.5/2 ton and taking down of UNSV compressor, all as specified and directed by Engr-in-charge Make of AC - LG, Samsung.
S & F and testing of thermistor (temprature Sensor) for split type air conditioner of capcity 1.5/2 ton and taking down UNSV Blower, all as specified and directed by Engr-in-charge make of AC - LG, Samsung.
S & F and testing of PCB for window/ split type air conditioner of capcity upto 2 ton and for FCUs of capacity upto 4500 kCal/hr and taking down UNSV PCB, all as specified and directed by Engr-in-charge make of AC - LG, Samsung.
Supply and fixing, in improvement/ enhancement/ replacement of heating dehumidifier element of ACs/ CHS, Oil Filled Radiators, of minimum 11 Fins, of minimum 2900 Watts, PTC cutoff type, of Make Usha/ Havells/ Morphy Richards, all as directed and specified by engineer in charge
S & F and testing of Blower for split type air conditioner of capcity 1.5/2 ton and taking down UNSV Blower, all as specified and directed by Engr-in-charge make of AC - LG, Samsung.
S & F and testing of transformer for split type air conditioner of capcity 1.5/2 ton and taking down UNSV Blower, all as specified and directed by Engr-in-charge make of AC - LG, Samsung.
S & F and testing of out door unit fan blade for split type air conditioner of capcity 2/ 1.5 ton and taking down UNSV Sensor, all as specified and directed by Engr-in-charge make of AC - LG, Semsung .LG.
S & F and testing of outer unit fan motor unit, of split type air conditioner of capcity 1.5/2 ton and taking down of UNSV fan, all as specified and directed by Engr-in-charge make of AC - LG, Samsung .LG.
S & F and testing of 2 Way Valve Assembly of split type air conditioner of capcity 1.5/2 ton and taking down of UNSV fan, all as specified and directed by Engr-in-charge make of AC - LG, Samsung .LG.
Supply, fixing in repair and checking of leakage for Copper pipe of size 1/2 inch including cutting, gas welding complete all as specifide and directed.
Supply, fixing in repair and checking of leakage for Copper pipe of size 1/3 and 1/4 inch including cutting, gas welding complete all as specified and directed.
Supply and fixing of Capaciter 50 MFD for 1.5 / 2 ton AC complete all as specifide and directed. Make USHA/ASIAN/GC.
Supply , fixing and testing of 3 Way Valve Assembly controling of cooling and heating of split type air conditioner of capcity 2/ 1.5 ton and taking down UNSV valve complete all as specified and directed by Engr-in-charge make of AC - LG, Samsung .
Supply Only of gas R-22/ R-410/R32/ R134a Refrigerant Gas in small disposable cylinders as directed by engineer in charge
Supply and refilling of gas R-22/ R-410/R32/ R134a for split/ window/ central package type Air conditioners and Refrigerators incl checking and fixing leakage complete all as specified and directed by Engrs-in-charge..
Supply and fix in replacement LED 9 w ,230v Indoor recess mounting down light circular and flat type, Chip on Board, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, all as specified and directed. Make Havells/Philips/C&S.
supply and fix in replacement Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED 7W/ 9W (TU) B22 basewitth 1x9 watt LED lamp complete all as specified and directed by Engr-in-charge . Make Havells/Philips/C&S
supply and fix in replacement 1x7 watt LED lamp (B-22 Base) 230v decorative wall mounting type with multicolour ABS housing with poly carbonate rings, and with designer ceramic or designer glassware cover/, enamelled bronze base, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed by Engr-in-charge. Make - as approved by Eng-in-charge.
supply and fix in replacement unique LED flood/ focus light 20 W LED 6500 K with IP 65 protection complete all as specified and directed by Engr-in-charge Make Havells, Philips ,C&S
Supply and fixing Ultra Violet UVC, germicidal type, 10W LED (or 20W Flurescent) Tube lights (or mounted type lamp), including fittings, 2 feet, as directed and specified by Engineer in Charge, Make - as approved by Eng-in-charge.
S&F sheet metal enclosure for Triple Pole Neutral type DBs (double door type), with back cover, wooden enamel finish or painted (as specified and directed), when MCBs to be used 4 to 12 way (as directed) incl blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche, with MCB provided by MES, complete all as specified and directed.
S&F MCCB/ RCBO (as directed) four pole 16 to 100 Amps (as required at site) 415 Volts, 16 KA complete all as specified and directed.Make: Havels /Legrand/ L&T
Taking down of unserviceable Geysers of any capacity and any type and deposit the same to the MES yard after cleaning including dismantalling and disconnecting electric and water supply connection, complete all as specified and directed by engineer in charge.
Supply and fixing steam generator of capacity 9 kW with digital temperature controller having temperature sensor (having temperature and timer display and control functions and additional features such as diffent power settings and control through phone), in for medical room with allied electrical and plumbing accessories, as directed by engineer in charge. Make - as approved by Eng-in-charge.
Supply and fixing, instant geyser having minimum capacity of 03 ltrs heating tank and minimum heating coil wattage of 2000 watts with all electrical and plumbing accessories, as directed by engineer in charge Make - as approved by Eng-in-charge.
Supply and Fixing Industrial Type Single Pole and Neutral Sheet metal enclosure with one Single pole MCB 10 - 20A two pin and earth plug and socket complete
M& L for Repair and replacment unserviceable wornout/ Burnt parts of Voltage Stablizer 1 KVA to 5 KVA of any make complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement of Stabiliser for 2 Ton Air Conditioner, Digital Type, of Model of V Guard -VG500 or equivalent as approved by engineer in charge.
Supply and fixing in replacement Operation Theatre Lights, double dome shadowless type, having minimum of 1,00,000 lux per dome, complete with boom, adapter and fittings, lifespan of 50000 hrs, 220V input supply through SMPS or direct, housed in hard plastic as approved by engineer in charge. Make - as approved by Eng-in-charge.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
Supply only copper thimble of size 25 sqmm
Supply only copper thimble of size 35 sqmm
Supply only copper thimble of size 50 sqmm
Supply only aluminium thimble of size 70 sqmm
Supply only aluminium thimble of size 95 sqmm
Supply only aluminium thimble of size 120 sqmm
Supply only aluminium thimble of size 150 sqmm
Supply only aluminium thimble of size 185 sqmm
Supply only aluminium thimble of size 240 sqmm
Supply Only LED Bulb, 7 Watt, B27/ E14 pin type (as directed), warm white, all as directed and specified by engineer in charge, of make of Havells/ Polycab/ Anchor/ Syska/ Bajaj, etc
Suppy Only screws of various sizes (as directed), for connecting electric boards and switch boards
M/S RAFIQ AHMAD SOFI AND SONS
GH MOHD SHAH AND CO
M/S SAJAA CONSTRUCTION COMAPNY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .