Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.8 L+₹3.5 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.4 L+₹5.0 L (16.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.1 L+₹5.8 L (18.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L4₹44.3 L+₹12.9 L (41.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI
GE (AF) E/M CHAKERI KANPUR
REPAIR AND MAINTENANCE OF STREET LIGHT INCLUDING ALLIED WORKS IN TECHNICAL AREA AT AFS KANPUR
2024_MES_676327_1
8718/E8
Open Tender
Civil Works
Item Rate
270 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹80,000
Yes
22 Jan 2025
24 Sept 2024
26 Oct 2024
25 Sept 2024
21 Oct 2024
8 Oct 2024
Amount
Excavation in trunches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M&L for double walled corrugated DWC HDPE pipe of outer dia 50mm and inner dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50sqmm cable complete all as specified and directed.
Supply & fixing or laying galvanised steel tubing light grade 40 mm bore (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe all as directed by Engineer in Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-2 complete all as specified and directed .
M & L for boring in any type of soil under road 60cm below the top surface of road complete for passing through 40mm to 50mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
Supply and lay testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core. laid in trench/ duct / along pole/wall etc including suitable size lugs, glands,Nut, bolts, washers & insulation tape etc making connection complete all as specified directed. Note : The cost of thimbles/lugs and cable gland etc is including in quoted rate and no extra payment will be made for it.
All as per item No. 08 above but cross sectional area 25 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 08 above but cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 08 above but cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
Supply jointing, commissioning and testing inreplacement of heat shrinkable straight through Joint suitable for cable of size 10 to 16 sqmm, 2/3.5/4.0 core, 1100 volts grade complete all as specified and directed by EIC.
Supply jointing, commissioning and testing inreplacement of heat shrinkable straight through Joint suitable for cable of size 25 to 50 sqmm, 2/3.5/4.0 core, 1100 volts grade complete all as specified and directed by EIC.
Supply and fixing Energy saving & Enviroment friendly LED street light fittings made out of pressure die cast anodized alluminium housing having capacity 60 watt with high efficiency polycarbonate UV stablized cover with integrated lens to ensure asymmetrical light and overall IP protection IP 65 or better complete all as specified & directed by Engineer in Charge.
Supply and fixing Energy saving & Enviroment friendly LED street light fittings made out of pressure die cast anodized alluminium housing having capacity 90 watt with high efficiency polycarbonate UV stablized cover with integrated lens to ensure asymmetrical light and overall IP protection IP 65 or better complete all as specified & directed by Engineer in Charge.
Supply and fixing in replacement of LED Flood lights 100 watt with high luminus efficacy, protected to IP65 with front toughened glass, with all necessary accessories required effective range including necessary mounting arrangement such as flat iron clamps, nuts, bolts & washers etc complete all as specified and directed
Supply and fixing in replacement of LED Flood lights 250 watt with high luminus efficacy, protected to IP65 with front toughened glass, with all necessary accessories required effective range including necessary mounting arrangement such as flat iron clamps, nuts, bolts & washers etc complete all as specified and directed
S&F in replacement of LED highbay light 150 W energy saving and envirment friendly light fitting, pressure dia cost aluminium housing with aim & adjustable bracket, matt finished reflector for gglare elimination, SMD LED with secondary lens with IP 66 protection including all fixing accessories complete all as specified and directed by Engr-in-Charge.
S & F in replacement decorative Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply only LED driver suitable for street/ security/ flood light fitting 1 X 60 / 70 / 100 watt 230V, any type/make all as specified and directed.
Supply only LED driver suitable for street / security /flood light fitting 1 X 150/200/250 watt 230V any type/make all as specified and directed.
S&F in replacement of MCCB, thermal magnetic protection type of 63 Amps 25KA, 4 pole, 415 volts fixed with and including lugs, nuts, bolts, washers, spacers, studs, links etc testing and commissioning complete all as specifiedand directed..
S&F in repair FRP looping box 350x270x200mm with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting, tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 6 Amp, 04 Nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed
Supply, installation, commissioning and testing in replacement of LT feeder piller box outdoor type, IP 54 protection made out of 3.15mm thick CRCA sheet metal, double door type and sitable MS angle iron base frame, cubical type floor mounted 3 phase 4 wire, 415V properly insulated aluminium bus bar-04 Nos having capacity 375 Amps on phase and neutral, dustand vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, RYB indication lamp with Digital multifunction meter, suitable size platform built with brick work in CM (1:4) 15mm thick ,plastering in CM (1:6), 0.6Mtrs height from GFL, including lugs, gland , thimble and nut bolts etc electric connection complete etc all as specified and directed by EIC. Note:- Incoming and Outgoing : (i) MCCB 250 Amps, 25KA , 4P, 415V - 01 No, (ii) RYB inidication lamp (iii) Volt meter and Ammeter.
S & F in replacement of galvanized anti corroded weather proof octagonal electric poles 7 Mtrs long top mounting on foundation complete with base plate including PCC foundation as per SSR provision and directed with 1200 mm long arms bracket, tapper plug, bolts, nuts and screws etc as specified complete including taking out existing RCC/ damaged rusted MS pole and street light bracket complete all as specified and directed by EIC. Note :- 1. Rate quoted by contractor deemed to be inclusive of required excavation work . 2. PCC and foundation shall be measured and paid seperately under seperate items 3. Old LT steel pole if retrieved , shall be deposited to MES store
M&L for plain cement concrete (1:3:6) Type C2 using 40 mm graded stone aggregate complete all as specified and as directed by Engineer- in -Charge.
M&L for cement concrete 1:2:4 Type B 2 using 40 mm graded stone aggregate complete all as specified and as directed by Engineer- in - Charge.(For LT pole foundation base, coping new and demolished one)
Supply & fix in repair Rigid non-metallic grade PVC conduit of size 20 mm dia including sockets, suitable size lenth of pvc threads for tighting of conduit areound the pole etc complete as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint complete including dismantling cross arms of MS channel complete etc. all as specified.
Supply and fixing in replacement of Isolator/MCB, 4P, 10 kA, 'C' 63 Amps, 415 volts 50 Hz all as specified and directed
Material & Labour in replacement for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 6 Sqmm for street light service cable all as specified and directed.
Material & Labour in replacement for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 10 Sqmm for street light service cable all as specified and directed.
Material & Labour in replacement for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 16 Sqmm for street light service cable all as specified and directed.
S & F in repairs security light brackets with 1.50mtrs long 40/50mm dia light grade galvanised iron pipe with 30° bend including flat iron clamps, nuts, bolts and washers to brace the same properly duly painted with two coats of silver coloured synthetic enamel paint over one coat of red oxide primer and making the good to disturbed surfaces to match with existing, complete all as specified and directed.
Supply and fixing in repair 1.5 Sqmm three core PVC insulated FRLS flexible copper conductor wire for street/security light terminal box , incl suitable size of bottle lugs etc complete all as specified and directed.
Labour only for checking the serviceability of street light fittings including lowering down form electric pole up to height 11.00 Mtr (except high mast light) if needed and testing of different spares / components / parts of security light fittings of any wattage/capacity of any description and in any position, checking functioning of contactor, MCCBs and their replacement if found to be unserviceable, regular cleaning of dust & dirt deposit due to natural effects, removal of carbon deposits it any or as direction of Engr-in-Charge and replacement of un-serviceable/ damaged /broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. Note for item is as under:-
Spare parts/componenets required to make the light fittings serviceable shall be measured and paid for separately under respective item of sch 'A'.
Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc.
Required screws, insulating tapes, internal wiring wire ,gaskets, tape insulation and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
Taking down unserviceable street/security light fittings of any type,wattage and make from LT/HT poles and transporting from site to MES store yard for repairing in deemed to be included in this item rate. The defective street light fittings will be repaired only at MES yard/place as directed by Engr-in-Charge.
Lowering of high mast light assembly from upto 16 Mtr high mast,any type, make and wattage, dismantling, checking parts and components for replacement, if required, and making the light fittings operational to give rated illumination including. cleaning of glass cover and refixing the same after repair/replacement of defective components complete with necessary electrical connection with by providing 3 core 1.5 Sqmm PVC sheathed multi stranded copper conductor cable of required length complete all as specified and directed. Note :-Spare parts/components to be replaced shall be measured and paid for separately under respective item of sch 'A'. The cost of greasing of pully, roller, bearing and gear including refixing of rope clamps, adjustment of lock, leaver etc shall be deemed to include the quoted rate.
Supply & Fix in repair trailing cable 4 Sqmm, 5 core copper conductor EPR insulated PCP sheathed cable having current carrying capacity 30 Amp complete all as directed by Engr-in-Charge.
Supply & Fix in repair trailing cable connector and terminal box complete all as specified and directed. Make and Model as per existing.
Supply & Fix in repair high mast 3 phase, 440 volt integral motor remote control switch with one No MCB 4 pole, 63 Amp complete all as directed by Engr-in-Charge. Make :- As per existing.
M&L repair, welding of High Mast feeder pillar box front/ rear door and locking arrengement including paint patch work making good as per existing colour and as directed by Engr-in-Charge.
Supply and fixing in replacement for automatic street light switch using nature switch for automatic switching of street lights base on LUX level of Natural light. The infrared sensor based nature switch alongwith suitable power cotactors and MCBs (Input-Output) should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proff, termite proof and FR grade thermoplastic polycabonate enclosure conforming to IP-66 protection class 2. The contactor, MCB and copper circuit wiring (min 10 Sqmm) should suitable enough to take single phase load of 5 - 8kW, contactor rating 40 Amps, MCB(SP) rating 32 Amps (2 Nos) complete all as specified and directed
Supply & Fixing in replacement of Power Timer contactor, 03 pole, 40 Amps complete all as directed by Engr-in-Charge
Supply & Fixing in replacement of Power Timer contactor, 03 pole, 63 Amps complete all as directed by Engr-in-Charge
Supply & fixing in replacement Automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/sun set by setting date, time and degree of longitude and latitude without separate light sensors complete all as directed by Engr-in-Charge
Supply and fixing in replacement Automatic operation street light timing switch having lighting control (ON-OFF) through Dail type timer switch (24 Hours) complete all as directed by Engr-in-Charge
M&L for preparation of exposed steel surface of steel tubuler pole (up to 11 mtr long) by scrapping, cleaning and painting by one coat of aluminium paint after preparation , including primer of the steel surfaces including painting to pole with two coat blue & white paint in strap alternatively all round the poles and writing pole No. Hight of the strap shall be as per standard and Nos of strap shall be 05 Nos. Note: 1-Pole number shall be recored in MB for payment purpose. 2- Pole existing tech area other than Runway inside boundary wall shall be considered for painting.
M&L for cutting of crawles along the electric pole of any type and height arround the 2 Mtr from the pole including removing the crawler from site and depositing at places all as directed by Engr in Charge.
M&L for shifting of street light pole of any size & height to not more than 5KM distance and erecting (PCC 1:3:6 type C2) it in ground with proper coping (PCC 1:2:4 type B1) and reducing size of pole by cutting it all as per directed at site by Engr-in-Charge.
M/s A S Electrical (BID ID -3138209)
M/S PASHUPATI TRADERS (BID ID -3146154)
VEE KAY ENTERPRISES (BID ID -3138775)
PAWAN COOL CORPORATION (BID ID -3136866)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .