| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹37.9 L+₹6.8 L (21.7%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹43.0 L+₹11.8 L (37.9%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L3 | Rejected-Finance L3 | |
| 4 | L4₹43.4 L+₹12.2 L (39.2%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹47.0 L+₹15.8 L (50.8%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
18 Jun 2024, 6:00 pmClosed
Major S K Yadav GE(S) BATHINDA
GE(S) Bathinda Bathinda Mil Stn
GE(S) BTD 30 OF 2024-25 REPAIR REPLACEMENT OF INTERNAL UNSERVICEABLE POINT WIRING REWIRING FITTING FIXTURES DBs SUB MAIN WIRING SWITXCCHES AND CONNECTED ACESSORIES WORK IN GOVIND COLONY RANJIT COLONY AND JADUNATH ENCLAVE UNDER AGE EM IV UNDER G
2024_MES_655160_1
GE(S) BTD- 30 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(S) Bathinda
Class D
category b(i)
12 documents required · 12 mandatory
₹500
GE(S) Bathinda
₹94,000
Yes
9 Sept 2024
21 May 2024
20 Jun 2024
21 May 2024
18 Jun 2024
4 Jun 2024
Amount
Taking down carefully existing copper/ aluminium point wiring ( light, fan socket or power)complete including fixture and fittings such as Switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells , light fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition separately) and making good to the disturbed surfaces of walls,floors etc to match the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate.
Dismantling & Taking down of existing unsv light fittings/Fixtures for replacement etc. complete all as specified and as directed.
Dismantling & Taking down of existing unsv call bell for replacement etc. complete all as specified and as directed.
Dismantling & Taking down of existing unsv batten/angle holder for replacement etc. complete all as specified and as directed.
Dismantling & Taking down of existing unsv MCB, DBs,MCCB and Isolator for replacement etc. complete all as specified and as directed.
M & L Point wiring with multistranded copper conductor single core, PVC insulated and unsheathed FRLSH cable , including PVC insulated unsheathed multi stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly with GI terminal boxes, modular frame & cover plate ( suitable for modular switch/sockets) for the following :-
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sqmm ( nominal area) cable & 1.5 Sqmm ( nominal area) cable as earth continuity conductor in existing concealed conduit complete all as specified and directed by Engr-in-charge
Switch socket combination 3 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 2.5 Sqmm PVC unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board, complete all as specified and directed by Engr-in-charge.
All as per item No.8 , here-in-before but One socket outlet three pin,15 Amp on the Independent board complete all as specified.
One light point controlled by one push button with 1.5 Sqmm ( nominal area) cable & 1.5 Sqmm ( nominal area) cable as earth continuity conductor in existing concealed conduit complete all as specified and as directed.
One light point controlled by two way switch with 1.5 Sqmm ( nominal area) cable & 1.5 Sqmm ( nominal area) cable as earth continuity conductor in existing concealed conduit complete all as specified and directed by Engr-in-charge
Note for srl item no. 6.00 to 11 : 1. Switches & sockets shall be measured & paid separately under respective item of Sch 'A' 2. GI box shall be fixed flush in position with cement mortar ( 1: 4 ) complete all as specified.
S & F switch modular type single pole one way, 6 Amp one module, complete all as specified.
S & F switch modular type single pole one way,16 Amp one module, complete all as specified.
S & F socket outlet modular type multipupose, 2/3 pin, single pole one way,6 Amp, two module, complete all as specified.
S & F socket outlet modular type multipupose, 2/3 pin, single pole one way,6 / 16 Amp, two module, complete all as specified.
S & F switch modular type single pole two way, 6 Amp one module, complete all as specified.
S & F bell push switch modular type single pole one way, 6 Amp one module, complete all as specified and as directed.
S & F Fan regulator modular type, 5 step, high speed, two module etc.complete all as specified and as directed.
S & F call bell ding dong type AC 230 V etc. complete all as specified and as directed.
S & F ceiling rose,3 terminal PVC/Polycarbonate, suitable for 230 V, AC, 50 Hz supply, complete all as specified.
S & F wall mounted extruded Aluminium / polycarbonate integrated LED batten fixture with tube 1.2 m, 20 watt, 1.2 m 3000/6500K, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and integrated in built driver complete including making connection complete all as specified.
S & F wall mounted LED batten fitting 10 ( ± 10%) watt 6500 K, 0.6m, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and inbuilt driver complete including making connection complete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure double door 8 way SPN, 240 V, ISI marked complete with netural and earth link and 200 Amp rated bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed.
all as per item No. 24 above but 04 way TPN , 415 Volt complete all as specified and directed.
S & F in replacement of MCB 6-32 Amp , 240 Volt, single pole, 10 KA 'C' series complete all as specified.
S & F in replacement of MCB 40-63 Amp , 240 Volt, SPN, 10 KA 'C' series complete all as specified.
S & F MCB TPN 40 to 100 Amp, 415 Volts, 10 KA 'C' series complete all as specified
S & F in replacement of sub main two single core PVC FRLSH copper conductor unsheathed wire multi stranded 6.0 Sqmm along with earth wire 6.0 Sqmm copper conductor single core wire connected by common earth in and including medium grade 20 mm size concealed conduit complete all as specified. ( Note :- Two length of 6.0 Sqmm cable and one length of 6.0 Sqmm earth cable alongwith PVC concealed conduit will be measured as one running length)
Supply, installing,testing and commissioning ( in replacement ) of indoor type LT panel wall mounted , having dimensions not less than 1.4m x 0.8m x 0.2m with double door made out of 2mm thick CRCA sheet metal weather proof with thimble and cable entry boxes with cable gland, having 07 nos compartments for fixing of meters having acrylic cover. Panel should coverd from all sides with front and back lockable door and hinges complete with copper bus bar of capacity 200 Amps with heat shirnkable PVC sleev, with an angle iron base frame grouted in wall complete including painting with paint shade of epoxy based powder paint RAL 7032 & DMC insulators and consisting of the following :- (a) Incoming MCCB 63 Amps, 4 pole, 415 Volts, 16 KA - 01 No. (b) Outgoing MCB 32 Amps, SPN, 230 Volts, 10 KA , B curve - 06 ( outgoing one for each DU). ( c) Outgoing MCB 10 Amps, SPN, 230 volts, 10 KA, B curve - 01 No ( outgoing one for each DU.) (d) Internal power & control wiring with suitable PVC insulated FR single core multistranded copper wire cable. (e) Indicating lamp Set RYB type - 01 set. Note :- 1 Meters as dismantaled during panel replacement to be deposited in E/M store and shall be refixed in to the meter boxes after installation. 2. Drawing of meter box panel must be approved by by Engr-in-charge before placing order.
S & F in replacement single pole and neutral enclosure 240 V with a two pin and earth plug and socket complete with one double pole MCB 20 Amps complete all as specified and as directed.
S & F in repair RCCB Earth Leakage Protection 230 Volts, 25 Amp, AC type double pole 30mA ISI marked complete all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc. to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.
M&L for Attend the complaint for checking and locating faults of light/power circuits and defective electrical light/ fan/ bell/ switche 5 Amps/switch 15 Amp/socket outlet 5 Amps and 15 Amps for continuous electric supply or broken neutral system, rectify the same, tightening of loose wire/circuit by using the same old wire or by using new wire up to 1.00 metre length and similar petty work complete all as specified and directed at site. Note :Switches,sockets,bell push,call bell, light fitting/ Fixture shall be measured and paid separately under respective item.
S & F in repair switch piano, flush type single pole one way 5 Amp complete all as specified and as directed.
S & F in repair switch piano, flush type single pole two way 5 Amp complete all as specified and as directed.
S & F in repair switch piano, flush type single pole one way 15 Amp complete all as specified and as directed.
S & F in repair bell push 5/6 Amp 230 V, AC etc.complete all as specified and as directed.
S & F in repair socket outlet 3 pin, 5 Amp flush type etc.complete all as specified and as directed.
S & F in repair socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type etc.complete all as specified and as directed.
S & F in repair switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal etc.complete all as specified and as directed.
S & F in repair call bell ding dong type AC 230 V etc. complete all as specified and as directed.
S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and as directed.
S & F in repair wall mounted extruded Aluminium / polycarbonate integrated LED batten fixture with tube 1.2 m, 20 watt, 1.2 m 3000/6500K, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and integrated in built driver complete including making connection complete all as specified.
S & F in repair wall mounted extruded Aluminium / polycarbonate integrated LED batten fixture with tube 1.2 m, 25 watt, 1.2 m 3000/6500K, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and integrated in built driver complete including making connection complete all as specified.
S & F in repair wall mounted LED batten fitting 10 ( ± 10%) watt 6500 K, 0.6m, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and inbuilt driver complete including making connection complete all as specified and directed by Engr-in-charge.
S & F in repair decorative wall light fixture made of polycarbonate suitable for retrofit 9 watt LED lamp ( base B-22 ) complete with PC diffuser & including one 9 watt LED lamp (base, B-22) 6500 K, not less than 90 lumen/watt efficiency including making connection complete all as specified and directed by Engineer-in-charge.
S & F in repair lamp holder PVC/ Polycarbonate type with back plate etc. complete all as specified and as directed.
S & F in repair LED lamp 7 watt ( base B-22 ) 6500 K, not less than 90 lumen/watt efficiency complete all as specified and as directed.
S & F in repair LED street light ( bldg security light) 35 watt , 230 V,AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube up to 1.2 mtr length bent to shape with 02 sets of MS clamp made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and as directed.
S & F in repair rigid non - metallic PVC conduit external dia 20 mm in size inclusive of all Tees, bends, elbow, reducers, junction boxes, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddels, pipe hooks etc. complete all as specified and as directed.
S & F in repair Hylem sheet cover 3mm thick of size 5" x 5" complete with machine screws/washer with provision of slots for switches, sockets, fan regulators ( including refixing of all switches, sockets, fan regulator dismantled from existing sheets) etc. complete all as specified and as directed.
S & F in repair Hylem sheet cover 3mm thick of size 8" x 5" complete with machine screws/washer with provision of slots for switches, sockets, fan regulators ( including refixing of all switches, sockets, fan regulator dismantled from existing sheets) etc. complete all as specified and as directed.
S & F in repair Hylem sheet cover 3mm thick of size 11" x8" complete with machine screws/washer with provision of slots for switches, sockets, fan regulators ( including refixing of all switches, sockets, fan regulator dismantled from existing sheets) etc. complete all as specified and as directed.
S & F in repair sunken box of size 4" x 4" with approved depth and thickness complete with earth dolly including making good the diturb surface CM ( 1:3 ) to match the existing complete all as specified and as directed.
S & F in repair sunken box of size 7" x 4" with approved depth and thickness complete with earth dolly including making good the diturb surface CM ( 1:3 ) to match the existing complete all as specified and as directed.
S & F in repair sunken box of size 10" x 7" with approved depth and thickness complete with earth dolly including making good the diturb surface CM ( 1:3 ) to match the existing complete all as specified and as directed.
M & L in replacement for earthing circuit wiring ( green colour) with multistranded copper conductor , single core FRLS, PVC insulated and unsheathed cable of size 1.5 Sqmm, run through existing conduit connected to existing terminal/ socket point outlet / MCBs etc. complete all as specified and as directed. Note :- One run of cable in existing concealed conduits/surface drawn with suitable saddling shall be measured as one running meter ( RM) and shall deemed to be included in the quoted rate.
M & L in replacement for earthing circuit wiring ( green colour) with multistranded copper conductor , single core FRLS, PVC insulated and unsheathed cable of size 2.5 Sqmm, run through existing conduit connected to existing terminal/ socket point outlet / MCBs etc. complete all as specified and as directed. Note :- One run of cable in existing concealed conduits/surface drawn with suitable saddling shall be measured as one running meter ( RM) and shall deemed to be included in the quoted rate.
M & L in replacement for earthing circuit wiring ( green colour) with multistranded copper conductor , single core FRLS, PVC insulated and unsheathed cable of size 6.0 Sqmm, run through existing conduit connected to existing terminal/ socket point outlet / MCBs etc. complete all as specified and as directed. Note :- One run of cable in existing concealed conduits/surface drawn with suitable saddling shall be measured as one running meter ( RM) and shall deemed to be included in the quoted rate.
S & F in repair MCCB 415 V, FP 63 Amp 16 KA, complete all as specified and directed by Engr-in-charge.
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
M/s NIRMAN BUILDERS
Mohinder Pal and Sons
M/S SODHI ASSOCIATES
Aman Enterprises
ABHINANDAN ENTERPRISES
M/s Kataria Construction Company
M/S KARTIK BUILDERS
M/s Manav Builders
R K KATARIA AND SONS
LM CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .