| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹50.0 L+₹12,204 (0.24%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹51.4 L+₹1.6 L (3.17%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹53.2 L+₹3.3 L (6.63%)Rejected-Finance 6 1ST CROSS 1ST MAIN OLD POLICE STATION ROAD LAKKASANDRA BANGALORE 560 030 | BENGALURU URBAN | KARNATAKA | 560030 | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹54.3 L+₹4.4 L (8.92%)Rejected-Finance | L5 | Rejected-Finance rejected being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Aug 2020, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
OUT SOURCING FOR DAY TO DAY E M MAINTENANCE SERVICES AND CERTAIN MISC REPAIRS REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIC SERVICES IN THE AREA OF AGE E M UNDER GE I RD EAST BANGALORE
2020_MES_360726_1
8958
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I R AND D East Bangalore
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹96,000
Yes
6 Nov 2020
14 Jul 2020
8 Aug 2020
14 Jul 2020
4 Aug 2020
30 Jul 2020
15 Jul 2020 - 22 Jul 2020
Amount
Providing services for maintenance and repair of internal electric supply and attending day to day complaints round the clock in all days in general shift in DRDO Phase II residential area except Sundays and Holidays all as directed/specified as under :- (a) Nature of duty :- (i) Attending of all day to day compliants of maintenance works. (ii) Replacement of fluorescent tubes, bulbs, building security lights of any wattage any type, chokes, starters , capacitors etc. (iii) Attending faults in 5/15 Amps sockets, single sockets, single phase and three phase power points, distribution boards, feeder pillar boxes of all types etc including internal wiring of buildings,ceiling fans, exhaust fans, geysers etc complete.
(iv) Periodical examination of feeder pillar boxes for any loose connection and tightening the same. (v) Inspection and testing of earth pits (vi) Collection job card maintained by the duty staff and attending the same without any loss of time (vii) Any other job required but not stated in this schedule but essential for smooth functioning of service centres (viii) The material required for attending the repair will be provided by the Department as and when required basis (except T&P which shall be provided by the contractor)
Operating staff to be employed as under :- (i) Electrician - 01 No for general shift excluding Sunday and Holiday (Total - 01 per day) Shift Timing :- 0900hrs to 1700hrs (general shift)
Note for Item Ser No. 36 (i) Necessary two Nos uniform duly marked as Category of workers and mobile facility shall be provided to electrcian. The rate shall be deemed to include for the same. (ii) Contractor will provide ITI certificate for electrician or minimum experience of 4 years from reputed organization (iii) PF, ESI of the tradesman is required & payment should be given through Bank account only (iv) If contractor fails to provide the tradesman the recovery should be @1500 per shift (v) Contractor will provide all the required Documents , Register, Tools, uniform, First Aid Box etc. at the duty places
Supply, install, testing and commissioning in replacement of CPRI approved LT Panel board, outdoor cubicle , dust and vermin proof made out of 3.15mm thick MS sheet with front end back door openable type fitted with nuts, bolts and washers fitted with knobs and hinges incl painting with two coats of enamelled paint over a coat of red oxide primer suitable for 415Volts 50Hz, 3 phase, 4 wire suitable for Pocket 1 and incl the following :-
(a) MCCB FP 415V 250Amps 35kA, adjustable thermal & magnetic settings - 01 No as incomer
(b) MCCB TP 100A, 25kA adjustable thermal & magnetic settings - 16 Nos as outgoing - 03 Nos
(e) Indicators RYB LED type - Set of three
(f) Aluminium bus bars 400 A TPN - 01 Set
(g) Internal wiring of panel board with copper cable of appropriate size single core including control fuses and cable glands, lugs of sutable size for incoming and outgoing cables, earthing terminals and cable glands
Supply, install, testing and commissioning in replacement of CPRI approved LT Panel board, outdoor cubicle , dust and vermin proof made out of 3.15mm thick MS sheet with front end back door openable type fitted with nuts, bolts and washers fitted with knobs and hinges incl painting with two coats of enamelled paint over a coat of red oxide primer suitable for 415Volts 50Hz, 3 phase, 4 wire suitable for Pocket 1 and incl the following :-
(a) MCCB FP 415V 200Amps 35kA, adjustable thermal & magnetic settings - 01 No as incomer
(b) MCCB TP 100A, 25kA adjustable thermal & magnetic settings - 16 Nos as outgoing - 02 Nos
(e) Indicators RYB LED type - Set of three
(f) Aluminium bus bars 400 A TPN - 01 Set
(g) Internal wiring of panel board with copper cable of appropriate size single core including control fuses and cable glands, lugs of sutable size for incoming and outgoing cables, earthing terminals and cable glands
Painting of LT outdoor type feeder pillar box of size not more than 1.50 x 1.25 x 0.75m with two coats of enamelled paint over a coat of red oxide primer including repair to the hinges and locking system , cleaning inside the panel, cleaning the vegetation around the foundation upto 1.0 mtr around complete all as specified and as directed
M & L for servicing of 4 pole structure including greasing of 03 Nos GOD, replacemet of all jumpers with proper lugs/thimble, painting the structure and channels , replacement of wornout nuts bolts, replacement of blown fuses , trimming of tree branches including painting to the structure with aluminium paint over a coat of red oxide primer complete all as specified and as directed Note: 1. Proper shut down should be taken in advance. 2. All Safety precautions should be taken by the tenderer
M&L Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn in and including rigid PVC type conduit concealed in walls / floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasis to the wall s/ floors/ ceiling and repairing with existing surface after work including taking down carefully unserviceable point wiring with fittings complete all as specified and as directed.
One light/ fan/exhaust fan point controlled by one way switch
One light point controlled by 02 two way switches
One three pin socket outlet 6 amps socket on the same board with other switches
One 3 pin socket point 5 Amps on the independent board.
One bell point controlled by one bell push
All as per item No 6 here-in-before but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 1.5 sqmmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps soket outlet independently all as specified and as directed by engr-in-charge.
Supply & fix switch modular type single pole 1 way 5 Amp 230 volt complete as directed.
Supply & fix switch modular type single pole 2 way 5 Amp 230 volt complete as directed.
Supply & fix socket 6 Amps modular type, 230 volts grade all as directed.
Supply & fix switch modular type 1 way 16A, 1 module all as specified and directed.
Supply & fix Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as directed.
Supply & fix Modular switch bell push 6 Amps one module all as specified and directed by Engr-in-Charge
Supply & fix modular type fan regulator 120 W two module complete all as specified and directed by Engr-in-Charge
Supply and fix bell AC 230V single phase all as specififed and directed by Engr-in-Charge
Supply & fix ceiling rose surface bakelite two to three terminal complete all as directed.
Supply & Fix angle holder polycarbonat/bakelite type with back plate complete all as specified and directed including one number LED lamp of 9Watts
Fixing only in replacement of fluorescent tube light fitting with energy efficient LED fitting 20 watts surface mounted with polycarbonate housing & integrated electronic driver including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed by Engr-in Chrage Note :- LED fitting will be issued by the department under Sch 'B'
Supply and replacement angle holder/tube light fitting with decorative LED mirror light fitting surface mounted of capacity of 07W translucent acrylic diffuser including driver and accessories complete all as specified. including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed Make : Crompton Cat Part No : LCL-07-CDL or equivalent in Havells/WIPRO/Phillips
Supply and replacement of any type of fitting with LED type surface mounted decorative oval bulk head fitting edge lit of 10Watts complete including connecting to ceiling rose with twin copper conductor of size 0/0.24 all as specified and directed Make : Havells Cat part No : RUGBYNEONFT10W LED760SSYMBOPC or equivalent in WIPRO/CG/Phillips
Dismantling the ceiling fan complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete testing all as directed Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted
Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper wining from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacment of capacitor and complete testing all as directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective item. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
All as per item No.22 herein before but for 1400mm sweep ceiling fan
All as per item No.22 herein before but for 300mm sweep exhaust fan
All as per item No.22 herein before but for 450mm sweep exhaust fan
Supply and replace worn out fan bearings of the existing size of superior quality complete all as specified and directed
Supply and replace capacitor 2.5mfd suitable for 1200mm sweep ceiling fan complete all as specified and directed
Supply and replace capacitor 4.0mfd suitable for exhaust fan complete all as specified and directed
Supply and replace rubbr reel of superior quality along with gun metal frame and split pin complete all as specified
Supply and fix exhaust fan louvers on outside of the external wall suitable for 380mm sweep for G+5 buildings complete all as specified and as directed
Supply and fix exhaust fan louvers on outside of the external wall suitable for 450mm sweep for G+5 buildings complete all as specified and as directed
Painting of ceiling fan along with down rod and blades using spray gun with existing colour at the site including dismantling the fan from the hook complete all as specified and as directed
M & L for submain wiring of 2 run 4 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including one run of 2.5 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge
M & L for submain wiring of 2 run 6 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including one run of 4 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge
M & L for submain wiring of 4 run 10 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including two run of 6 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables all as specified and directed by Engr-in-Charge
Supply and fix in replacement of MCB DB SPN 4 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 6 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB DB SPN 8 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
Supply and fix in replacement of MCB SPN 6-32Amps 230 Volts single phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB SP 6-32Amps 230 Volts single phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TP 63Amps 415 Volts three phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TPN 6-32Amps 415 Volts three phase all as specified complete including dismantling the old one
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground( earth pit not less than 2.25metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected as required 32 x 6mm upto 7.5Mtr GI strip up to means of GI bolts, nuts , check nuts and washers and connected to building panel/DB all as shown in electrical plate No. 3 of SSR Part I and all as specified including testing on completion, taking down old unserviceable earthing complete all as specified and directed by Engr-in-Charge.
Ashraya Nirman
HEERA CONSTRUCTION CO.
Sri Vijalakshmi Constructions
M/S Anu Enterprises
Lucky Enterprises
Eastern Engineering Works
G K CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .