Tender Value
₹39.1 L
Closing Date
2 Feb 2022, 2:00 pmClosed
Project Director
Office of Project Director, FRFCF, BARCF, Kalpakkam
Preventive Maintenance and Major Overhauling of Power and Distribution Transformers at FRFCF, Kalpakkam
2021_BARC_665517_1
BARC/NRB/FRFCF/ELE/T-166/2021
Open Tender
Electrical Works
Item Rate
730 days
Kalpakkam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
31 Mar 2022
7 Jan 2022
7 Feb 2022
7 Jan 2022
2 Feb 2022
11 Jan 2022
10 Jan 2022 - 31 Jan 2022
Amount
Preventive Maintenance and Testing on oil type power Transformer of capacity of 33kV/6.6kV,12.5MVA as per the scope of work.
Preventive Maintenance and Testing on Dry type distribution Transformer of capacity of 6.6kV/433V,2MVA as per the scope of work.
Preventive Maintenance and Testing on oil type distribution Transformer of capacity of 6.6kV/433V,650KVA as per the scope of work.
Preventive Maintenance and Testing on oil type distribution Transformer of capacity of 6.6kV/433V,1000KVA as per the scope of work.
Preventive Maintenance and Testing on oil type distribution Transformer of capacity of 11kV/433V,1000KVA as per the scope of work.
Dismantling,shifting to factory,overhauling,testing at facotry,shifting to site,unloading,erection and testing at site of 500KVA, 11KV/0.433KV Transformer as per the scope of work
Dismantling,shifting to factory,overhauling,testing at facotry,shifting to site,unloading,erection and testing at site of 250KVA, 11KV/0.433KV Transformer as per the scope of work
Oil leakage arresting of 33kV/6.6kV,12.5MVA power transformers as per the scope work
Oil leakage arresting of 6.6kV/433V,630KVA distribution transformers as per the scope of work
Oil leakage arresting of 6.6kV/433V,1000KVA distribution transformers as per the scope of work
Cleaning and painting of 6.6kV/433V,630KVA oil type distribution transformers
Cleaning and painting of 6.6kV/433V,1000KVA oil type distribution transformers
Collection of Transformer oil samples and Conducting Break Down Voltage test as per the scope of work.
Reconditioning of silicagel in Breathers of Transformers/BOCBs/Storage Tanks as per the scope of work and as directed by Engineer In-Charge
Supply and installation of Buckholtz relay GOR3 as per the scope of work.
Supply and installation of MOLG as per the scope of work.
Supply and installation of Silicagel as per the scope of work.
Supply and installation of Silicagel breather for 12.5MVA transformer as per the scope of work.
Supply and installation of Silicagel breather for 1MVA transformer as per the scope of work.
Supply and installation of Silicagel breather for 630 KVA transformer as per the scope of work.
Supply and installation of OTI as per the scope of work.
Supply and installation of WTI as per the scope of work.
Reconditioning of Transformer oil in Transformers /storage Tank/ Drums-Oil quantity upto 1000 ltr
Reconditioning of Transformer oil in Transformers /storage Tank/ Drums-Oil quantity above 1000 ltr upto 7000 ltr
Clearing Heavy jungle area including removal all unwanted plants, branches, twigs, wild growth, trees and saplings of girth upto 30cm, uprooting of rank vegetation etc. complete, and disposing the same 100metres away by manually or burning them without disturbing other areas etc., complete all as directed by the EIC. The useful firewood if any, shall be cut and stacked at a place (with 100metres lead) as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from EIC before burning the wild growth.
Clearing light jungle area, bulb weeds, grass including removal all unwanted plants, branches, twigs, wild growth etc.complete, and disposing the same 100 meters away manually or burning them without disturbing other areas etc., complete all as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from him for burning the wild growth as per the scope of work.
Maintenance on 4pole structures including replacement of insulators, terminal connectors and jumpers as per the scope of work and as directed by Engineer In -Charge
Aluminum painting of 4 Pole structures of height 12mtr approx for 11kV /6.6kV/33kV as per the scope of work and as directed by Engineer In -Charge
THARIQUE ELECTRICAL CONTRACTOR
Trans Electro
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .