GEMC-511687706422360
Awarded to GANIT STAR ENGINEERING
₹10.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 150W FLOOD LIGHT | GANIT & SLIM 150W | - | 250 NOS | ₹4,124 | 1,031,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.3 LQualified Make: GANIT
Model: GANIT & SLIM 150W 32 35 SINHASA IT PARK DHAR ROAD INDORE MADHYA PRADESH 452013 | INDORE | MADHYA PRADESH | 452013 | Make: GANIT
Model: GANIT & SLIM 150W | ₹10.3 L | L1 | Qualified |
| 2 | L2₹12.3 L+₹1.9 L (18.8%)Qualified Make: Master Controls
Model: ECFS-150W-NW 5 37 KIRTI NAGAR INDUSTRIAL AREA NEW DELHI WEST DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110015 INDIA | WEST DELHI | DELHI | 110015 | Make: Master Controls
Model: ECFS-150W-NW | ₹12.3 L+₹1.9 L (18.8%) | L2 | Qualified |
| 3 | L3₹13.2 L+₹2.9 L (28.0%)Qualified Make: UNISTAR
Model: UN-FL150 H NO A 5B 105 S F S FLATS NEAR AVTAR ENCLAVE PASCHIM VIHAR DELHI DELHI 110063 | WEST DELHI | DELHI | 110063 | Make: UNISTAR
Model: UN-FL150 | ₹13.2 L+₹2.9 L (28.0%) | L3 | Qualified |
| 4 | L4₹14.6 L+₹4.2 L (41.1%)Qualified Make: OREVA
Model: ORFLD-150W 1033 527 B UNCHWA GARHI KUTCHERY RAJAPUR ALLAHABAD ALLAHABAD UTTAR PRADESH 211002 UDYAM UP 03 0003958 | PRAYAGRAJ | UTTAR PRADESH | 211002 | Make: OREVA
Model: ORFLD-150W | ₹14.6 L+₹4.2 L (41.1%) | L4 | Qualified |
| 5 | L5₹16.8 L+₹6.5 L (62.9%)Qualified Make: JILCO
Model: JLED-BFLF-150 B 70 21 22 23 DSIDC IND COMPLEX LAWRENCE ROAD DELHI DELHI 110035 | NORTH WEST DELHI | DELHI | 110035 | Make: JILCO
Model: JLED-BFLF-150 | ₹16.8 L+₹6.5 L (62.9%) | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
29 May 2018, 2:00 pmClosed
LED Luminaire (for Flood Light) LED Luminaire (for Flood Light) ( 250 ) Technical Specifications Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes - Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes - Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B - Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 - LED Rating/System Wattage/Rated Power 150W 150W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt - Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 - 1/7 Mounting brackets (included) Adjustable - Warranty for free replacement (in Years) 2 - ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V - Automatic Higher Cut off voltage above 300 volt Yes - Rated voltage 230 V AC 50 Hz - AC Power Factor at full load ≥ 0.95 - Driver Efficiency (in %age) ≥85 - Total Harmonics Distortion (in %age) ≤ 10 - "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes - OPTICAL LED chip Efficacy ≥130 Lm/Watt - Colour temperature (+/-500K) 6000K - Working life for LED (Minimum 50
000 burning hours as per LM-80 report) Yes - Colour Rendering Index(CRI) ≥70 - Beam Angle ≥120 - Optic lense materal (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense - THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes - Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes - Junction temperature < 85 degC - Operating temperature range -10 deg C to +50 deg C - 2/7 Operating Humidity Range 10 % to 95% RH - PROTECTION Short circuit Protection Yes - Over load protecton Yes - Over Voltage protection Yes - Reverse polarity Yes - High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes - Insulation resistance between earth and current carrying part >100 M ohm - The luminaire shall be protected against surges and transients ( Internal) >/=5KV - The luminaire shall be protected against surges and transients of >/=10KV (External) No - CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes - The luminaire body must be corrosion resistant epoxy powder coated Yes - All fastners must be of stainless steel Yes - The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes - Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the Yes - 3/7 entry of the dust
water
insects etc.
Luminaries light transparency should be of Toughened glass Yes - Toughned transparent glass cover thickness >/=4 mm - Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes - Number of electronic control gear (power supplies) 1 No. 1 No.
2 Nos.
3 Nos.
4 Nos. Driver components shall be industrial grade or above Yes - PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes - The Luminaires works on single phase three wires system (Phase
Neutral and Earth) Yes - Suitable connector shall be provided for LED connection between driver output and LED Yes - Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm - Light Source SMD LED Chip as per LM 80/IS16106 - MARKING "Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed - Manufacturer’s name
model number
serial number Yes - Date of manufacture (month-year)
and lot number as identification mark inside each unit and the outside of each Yes - 4/7 packaging box The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes - REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND - System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes - LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output
power
PF
Current in Amps
CRI & CCT etc.
) Yes - LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being used in the luminaire) Yes - Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad Yes - 5/7 IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Seller has to furnish Type test report on demand by buyer/consignee Yes - DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes - LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Priya Ranjan Singh 829144
Makoli
Phusro 250 30 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 10.00 Duration of ePBG required (Months). 24
108725
GEM/2018/B/15515
GeM Contract
LED Luminaire (for Flood Light)
GeM Contract
30 days
Jharkhand; Bokaro
PRODUCT
Awarded to GANIT STAR ENGINEERING
₹10.3 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 150W FLOOD LIGHT | GANIT & SLIM 150W | - | 250 NOS | ₹4,124 | 1,031,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| LED Luminaire (for Flood Light) LED Luminaire (for Flood Light) ( 250 ) Technical Specifications Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes - Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes - Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B - Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 - LED Rating/System Wattage/Rated Power 150W 150W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt - Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 - 1/7 Mounting brackets (included) Adjustable - Warranty for free replacement (in Years) 2 - ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V - Automatic Higher Cut off voltage above 300 volt Yes - Rated voltage 230 V AC 50 Hz - AC Power Factor at full load ≥ 0.95 - Driver Efficiency (in %age) ≥85 - Total Harmonics Distortion (in %age) ≤ 10 - "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes - OPTICAL LED chip Efficacy ≥130 Lm/Watt - Colour temperature (+/-500K) 6000K - Working life for LED (Minimum 50 | - | - | - |
| 000 burning hours as per LM-80 report) Yes - Colour Rendering Index(CRI) ≥70 - Beam Angle ≥120 - Optic lense materal (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense - THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes - Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes - Junction temperature < 85 degC - Operating temperature range -10 deg C to +50 deg C - 2/7 Operating Humidity Range 10 % to 95% RH - PROTECTION Short circuit Protection Yes - Over load protecton Yes - Over Voltage protection Yes - Reverse polarity Yes - High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes - Insulation resistance between earth and current carrying part >100 M ohm - The luminaire shall be protected against surges and transients ( Internal) >/=5KV - The luminaire shall be protected against surges and transients of >/=10KV (External) No - CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes - The luminaire body must be corrosion resistant epoxy powder coated Yes - All fastners must be of stainless steel Yes - The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes - Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the Yes - 3/7 entry of the dust | - | - | - |
| water | - | - | - |
| insects etc. | - | - | - |
| Luminaries light transparency should be of Toughened glass Yes - Toughned transparent glass cover thickness >/=4 mm - Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes - Number of electronic control gear (power supplies) 1 No. 1 No. | - | - | - |
| 2 Nos. | - | - | - |
| 3 Nos. | - | - | - |
| 4 Nos. Driver components shall be industrial grade or above Yes - PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes - The Luminaires works on single phase three wires system (Phase | - | - | - |
| Neutral and Earth) Yes - Suitable connector shall be provided for LED connection between driver output and LED Yes - Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm - Light Source SMD LED Chip as per LM 80/IS16106 - MARKING "Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed - Manufacturer’s name | - | - | - |
| model number | - | - | - |
| serial number Yes - Date of manufacture (month-year) | - | - | - |
| and lot number as identification mark inside each unit and the outside of each Yes - 4/7 packaging box The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes - REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND - System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes - LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output | - | - | - |
| power | - | - | - |
| PF | - | - | - |
| Current in Amps | - | - | - |
| CRI & CCT etc. | - | - | - |
| ) Yes - LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being used in the luminaire) Yes - Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad Yes - 5/7 IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Seller has to furnish Type test report on demand by buyer/consignee Yes - DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes - LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Priya Ranjan Singh 829144 | - | - | - |
| Makoli | - | - | - |
| Phusro 250 30 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 10.00 Duration of ePBG required (Months). 24 | - | - | - |
Exempted
28 Jul 2018
19 May 2018
contract_GEMC-511687706422360.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_108725.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .