| 1 | L1₹31.1 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹31.1 L Quoted ₹31.8 L | L1 | Accepted-AOC Due to being L1 |
| 2 | L2₹33.0 L+₹1.2 L (3.77%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹33.0 L+₹1.2 L (3.77%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹37.2 L+₹5.3 L (16.8%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹37.2 L+₹5.3 L (16.8%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹37.2 L+₹5.4 L (17.1%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹37.2 L+₹5.4 L (17.1%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹38.6 L+₹6.8 L (21.3%)Rejected-Finance WARD NO 11 HOUSE NO 305 JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹38.6 L+₹6.8 L (21.3%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹85,820
Closing Date
26 Nov 2021, 6:00 pmClosed
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Provn of security lights and certain other E/M sanctioned works under GE (Utilities) Udhampur
2021_MES_484716_1
GE/U-49/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹85,820
Yes
13 Jan 2022
28 Oct 2021
3 Dec 2021
28 Oct 2021
26 Nov 2021
12 Nov 2021
Amount
Taking out the existing unserviceable LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for Phases and neutral - 01 set (b) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job (c) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 36/35 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 36/35 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos. (b) MCCB 4 pole ,Ics=100%Icu- 26/25 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals - 02 Nos. (c ) MCB SPN 63A -03 Nos
60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum- lumen output of luminarie should be 6600 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K). The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Make of LED shall be CREE/NICHIA/ OSRAM. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The potted driver used must be a constant current constant voltage driver with efficiency of > 85% including GI bracket and clamps, nut, bolt and washer and connection 3 core wire from connector to over head line. The manufactures LOGO must be embossed/ engraved in the housing of the luminarie. Make: Jaquar Cat No LSRT01S060XW or Philips Cat No BRP-409 LED 060 CW HE-NR PCS-1PSU GR or Wipro Cat No LR 02 671XXX57G2 or Polycab cat No PUB0506015
Flood Light of capacity 60W aluminium die cast housing luminaire for uniform illumination and toughened glass for IP66 protection. Make : Wipro CAT pt no. LF19-711-060-57-XX Crompton CAT Pt no. LFL-60-CDL/60-M or equivalent in Syska.
LED street Light of 60W made of die-cast aluminium, with optic LENS for uniform light distribution.Rate IP66. Make : Wipro CAT No.- LR02-671-XXX-57-G2 Crompton CAT Pt no. LST-60-CDL or equivalent in Syska.
120 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 14400 Lumens) color rendering (CRI) of > 70 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Make of LED shall be CREE/NICHIA/ OSRAM. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The potted driver used must be a constant current constant voltage driver with efficiency of > 85%. The manufactes LOGO must be embossed/Engraved in the housing of the luminarie. Make: Jaquar, Cat No LFLDSLM120XW or Philips Cat No BVP122LED 124 CW HE AK 55FG XTFCL S4 or Wipro Cat No LF20- 132-060-57-G2 or Polycab cat No PUB0506013.
LED Flood Light of 350W high efficiency made of aluminium die cast, with unique optic LENS for uniform illumination.Rated IP66. Make : Wipro CAT Part No.- LF20-442-060-57-XX Crompton CAT Part No.LSFO-350-CDL/60-M, CAT Part No. PCFLF C3 01 350 HL-LFL or equivalent in Syska.
Automatic street light control switch of 8 KW three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 (Hansel make). The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge. Model No SWADEEP 66- 8 KW3P or L&T or Havells or Indoasian
Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
ACSR conductor of required size for over haed lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor complete all as specified and directed by Engr-in-Charge.
Stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, complete all as specified and directed by Engr-in-Charge.
Supply ,fabricating and fixing in repairs cross arms ( any type) supports, bracing, stiffeners anti climbing spikes etc made out of MS channel, angle iron, flat of any size including drilling of holes making clamps including eye hooks, nuts bolts and washers etc welding if required including painting with two coats of aluminium paint over a coat of red oxide primer.
GI earth wire 8 SWG(4mm dia) on poles for continuous earth wire and for guarding cradles including binding to required shape with binding wire complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing and testing LT under ground cable 35 sqmm 3.5 core, heavy duty, XLPE insulated, screened, PVC bedded galvanised steel strip armoured, electric power cables with aluminium conductor, 1100 volts, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge.
All as per srl item No 13 here in before but of size 16 Sqmm 4 core
Excavation in trenches in any type of soil not exceeding 1.50 m wide and not exceeding 1.50 mtr in depth and getting out for cable complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 15 here in before but depth exc.1.5m but not exc. 3m complete all as specified & directed by Egnr-in-charge.
Returning filling in ( soil ) including spreading leveling watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed by Egnr-in-charge.
Double walled corrugated (DWC) pipe of size 75x61 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd
Double walled corrugated (DWC) pipe of size 50x38 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd
Double walled corrugated pipe (DWC) of size 40x32 mm with necessary Snap fit Coupler. Make : Tirupati/Rex/Polyextrusion.
Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete all as specified and directed by Engr-in-Charge.
Supply , installation, testing and commissioning of outdoor type,weather proof, feeder pilar box made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
M&L for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade of size 25 sqmm 3.5 core heavy duty ,laid in trenches/ducts/through pipe complete all as specified and directed. Make-Havells/Polycab/Gloster
PVC insulated multi stranded aluminium conductor PVC cable sheathed 10 sqmm twincore and making connections of street light fittings from UG cable complete all as specified and directed by Engr-in-charge. Make : Plaza/Paragon/kalinga.
Modular box made of FRP impact resistance plastic & heat resistant materials of suitable size to accommodate the fixtures with IP65 incl connector terminal block 4 pole suitable for fixing cable connection and fixing to pole with suitable nuts, bolts . Make : Sintex/Hansu
LED bollard lights of 11 watt capacity all as specified and dirfected by Engr-in-Charge. Make Wipro Cat Part No- LB-13-131-SPK-65-08 or equivalent make of CG/Phillips. Note- Necessary Grouting for fixing of bollard and taking down unserviceable bollard light deemed to be included in the quoted rate by the contractor.
Post top Lantern pure polyster UV resistant powder coated die cast aluminium housing with clear diffuser uniform illumination of 20W capacity LED type and taking down unserviceable post top lantern complete all as specified and directed by Engr- in- Charge. Make : Wipro Cat Part No.- LP07-501-XXX-57-CL/ Havells Cat Part No-CORALPT25WLED75PSYMTOPC. Note: Necessary grouting for fixing of PT lantern & taking down unserviceable fittings to be included in the quoted rate by the contractor.
LT UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor 100 volts grade of cross sectional area 16sqmm 4 core including taking down unserviceable cable complete all as specified and directed by Engr- in- Charge. Note :- Earth work shall be measured & Paid separately.
PVC insulated 1.5 sqmm multi stranded copper conductor cable from junction box to light fittings complete all as specified and directed by Engr- in- Charge.
GI tubing, light grade, 50mm including necessary clamps for the protection of the cable, laid in trenches/under road/path including taking down unserviceable pipecomplete all as specified and directed by Engr-in-Charge.
Moduler box made of FRP/impact resistance plastic & heat resistance incl MCB 20 Amps DP and connector terminal block 4 pole including taking down unserviceable junction box. Make : Sintex/Hensel
Focus light 8 watt for architectural and monument lightining including taking down unserviceable Focus light. Make : Wipro Cat Part No- LF05-600-036-27-XX or as equivalent Philips/CG.
Earthing complete with Copper earth plate electrode 600 mm x 600mm x6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level and covered with alternate compact layer of comen salt and charcol dust, connected to Copper earth strip of size 50mm X 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of Copper earth lead including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and connected to earthing test point all as specified and directed by Engr-in-charge.
Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. Note :-1. Cost of following items are deemed to be included in unit rate. a.20 mm nominal bore light grade GI pipe for provision of watering. b. Requisite quantity of common salt and charcoal. c. Testing of earthing.
Supply and fixing Copper strip 50X 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed by Engr-in-Charge.
Earthing with GI earth plate electrode 600x600x6.3mm buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32x6mm thick for earthing lead fixed by means of nuts, bolt, washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR 1996 part 1, including necessary excavation and earth work in any strata of soil, common salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel & wire mesh, PCC pit with CI cover and frame etc all as specified and directed by Engr-in-Charge. Note: All the joints shall be made with welding to get proper conductivity.
vijay kumar gupta and co
FANGALIA TRADERS
SINGH CONST CO
PARDEEP SHARMA
PREM NATH KHAJURIA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .