Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.3 L+₹1.3 L (9.94%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹14.6 L+₹1.6 L (12.6%)Rejected-AOC 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹15.0 L+₹2.0 L (15.3%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U)m E/M Meerut Cantt
GE(U)m E/M Meerut Cantt
MAINT AND REPAIR/REPLACEMENT OF STREET LIGHT, CABLES, JUNCTION BOXES AND ALLIED WORKS IN SOUTH AREA UNDER AGE E/M (ES) AT GE(U) E/M MEEERUT CANTT
2021_MES_469622_1
8365
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Meerut Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U)m E/M Meerut Cantt
₹40,000
Yes
23 Oct 2021
20 Aug 2021
21 Sept 2021
20 Aug 2021
18 Sept 2021
4 Sept 2021
20 Aug 2021 - 28 Aug 2021
90 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soil complete all as specified.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour river sand for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . ( Note: Punned thickness shall be measured for the purpose of payment)
M&Lfly ash old size bricks , straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Taking out unserviceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 25 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Taking out unserviceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
S&F pole mounting type junction box factory made of size 350x250x150mm of FRP sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA suitable for domestic loading , -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
S&F in repair Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to or not less than 90 watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with cable complete all as specified and directed. and making connections complete all as specified and directed by EIC.
Taking down unservuceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
S&F in repairs 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections to street light fittings complete all as specified and directed.
M&L for preparation of old painted surfaces erected steel tubular swaged poles / Rails/Girder poles of LT over head line ( Except embedded portion) , 9 M long including all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 04/ 05 Nos bands/ straps with Two coats of synthetic enamel paint ( black & yellow and Black and red white 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on yellow synthetic enamel piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified
Trimming/ lopping branches of tree touching to LT/HT OH lines not exceeding 30 cm girth , shrub, vegetation, bushwwod and saplings at least upto 3 M from outer edge of ACSR including removing of braches of trees etc. to a distance exceeding 100 m and not exceeding 150 M complete all as specified and directed. Note :- (i) Shutdown wherever required shall be taken in writtig from Engr-in-Charge.
Supplying and fixing 40mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of the following bore (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
S&F 40mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.5M duly bended and fabricated to 120 degree to shape consisting adapter (where required) to suit the opening of street light fitting, mounting brackets made out of 350mm long or higher mild steel FI 40x6mm required shape (Two Nos per GI pipe bracket) duly fitted with 4 Nos Mild Steel bolts 10mm dia, 50mm long with nut and washers or providing reducers and GI pipe of size suitable for existing top fixed bracket duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connection with cable complete all as specified and directed to poles etc.
Supply installation testing and commissioning of 3 Phase 5KVA, GCMS (Group control management system) central LT Panel with on/ off contactor for collective control, with input and output MCB 3 phase panel meter, remote data monitoring, notification of faults, suitable for surge protection, rotary switch for mannual operation, 2mm, MS sheet enclosure with proper earthing arrangements complete all as specified and directed- Note- The GCMS should have following features- (a) Input to GCMS shall be 3 phase control/1 phase grid power input and with 3 phase (Common phase /individual phase control/1 phase output for load with option to switch on and off the load (b) GCMS shall be able to measure voltage , current, power factor, Active power, apparent power, metering cumulative active energy , metering cummulative apperent energy (c) Time scheduling which could be defined from the GUI running locally in smart device (d) Communication-GPRS commuication between GCMS and cloud server street lights for futuristic expansion (e) Wireless local control for field staff to on/off GCMS in case of GSM failure.
S&F in repair Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to or not less than 70 watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with cable complete all as specified and directed. and making connections complete all as specified and directed by EIC.
Taking down LED street lights fittings from pole/ walls, opening of street light fittings of any type, wattage and make, making the light fittings operational to give the rated illumination by repairing/ renewal/ replacement pf components viz driver, LED bulbs, electronic circuit and other minor defective parts and refixing the street light in its original position and reconnecting with renewed cable of Twin core 2.5 sqmm stranded aluminium conductor cable ,PVC insulated and PVC sheathed cable of required length complete all as specified and directed. Note:- Driver only if renewed shall be measured separately at supplied only rates under relevant item (ii) Reparing to street light fittings shall be carried out at MES store yard of AGE E/M ES at Meerut.
Supply only Driver suitable for 25 watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
Supply only Driver suitable for 45/48 watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
Supply only Driver suitable for 60/70/72watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any dahage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Taking down of existing unserviceable MCB and S & F Miniature circuit breakers TPN, 32/40 Amps, 415 Volts , 10 KA, 'C' curve rating and to be housed in existing sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Taking down of existing unserviceable MCB and S & F Miniature circuit breakers TPN, 63 Amps, 415 Volts , 10 KA, 'C' curve rating and to be housed in existing sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Repair/maintenance of timer switch assembly of any TYPE and MAKE after dismantling the same from pole, detecting fault, rectifying the same, testing and refixing in the same position after repair/replacement of defective part all as specified. Note:- Parts replaced shall be paid at supply only rates under item no 26 to 27 here in under.
Supply only street light lexic power timer contactor,04 pole,40Amps complete all as specified and directed.
Supply only street light lexic power timer contactor,02 pole,40Amps complete all as specified and directed.
Supplying and fixing in repair automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed caable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted, connecting and testing factory made , epoxy powder coated, Single Phase street light panel, digital 24 hrs, suitable for 6KW (max) complete with 32 Amps TP Contactor, and 40 Amps SPN MCBs and fixed on pole/ wall/ feeder pillar complete all as specified and directed.
Supply and fix in repair SPN DBs for lexic MCB complete with SPN MCB 63 Amp, 10 KA, suitable for domestic loading, 240 Volt as as specified.
Supply and fix in repair Fire retardant low smoke (FRLS) PVC insulated unsheathed multi stranded single core aluminum conductor 1100 volts grade of size 2.5 Sqmm of suitable length for street light terminal to over head conductor complete all as specified
Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirtect light IP 65 protection with impact and corrosiion resistant made in cast aluminium with decorative opal poly carbonate diffusercomplete with driver and lamp complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 volt AC pressure dia cast housing outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver lamp necessary bracket, clamps and nuts & bolts etc required for fixing light fittings on ploe/ wall etc. complete all as directed.
Taking out unserviceable cable and Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor of 16 Sqmm 2 core complete all as specified and directed.
S&F in repair 20mm external dia rigid non metallic PVC conduit, medium grade including tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such couplers, lock nuts, saddles, pipe hook, etc fixed to poles with suitable size of PVC straps at every 50 CM complete all as specified.
Taking down of existing unserviceable MCB and S & F Miniature circuit breakers SP, 6 to 32 Amps, 240 Volts , 10 KA, 'C' curve rating and to be housed in exixting sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Narender Construction
Shikha Enterprises
M/S JPS Electrical Engineer & Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .