Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.8 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹15.2 L+₹36,347.80 (2.45%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹16.5 L+₹1.6 L (11.0%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹18.8 L+₹3.9 L (26.5%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹19.9 L+₹5.0 L (34.0%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
18 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
PROVN OF 5 MTR FIRE BREAK AROUND ESH AND STORE ROOM AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2021_MES_496391_1
GE/KC/NIT-50/2021-22
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Kaluchak
₹44,000
Yes
21 Mar 2022
21 Dec 2021
26 Jan 2022
21 Dec 2021
18 Jan 2022
4 Jan 2022
21 Dec 2021 - 28 Dec 2021
60 days
Amount
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipe etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Excavation over areas not exc. 1.5m deep in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in chajjas, complete all as specified & directed.
Use & waste of form work to sides of concrete foundation, footings, bases of columns, rafts and raft beamsand similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides of pillars, posts, structs, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to edges of concrete flats, treads, break in floors, window cills, concrete railings openings in concrete walls, floor and roof and n exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide for rough finished surfaces of concrete, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
40mm thick PCC 1:2:4, nominal mix, type B0, using 12.5mm graded crushed stone aggregate as in damp proof course to horizontal or vertical surfaces including necessary formwork, complete all as specified and as directed.
5mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on other than fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
5mm thick rendering in cement mortar 1:4 over 10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective items.
Supply only integral water proofing compound, complete all as specifed & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls, chajjas, facias, parapets and applying two coats of cement base paint of any tint over a coat of cement primer, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified & directed.
100mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in flooring, surface finished even and smooth without using extra cement, complete all as specified & directed.
Hard core of gauge n exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
Preparation of the concrete surfaces of accessible roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face, complete all as specified & directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Glass dividing strips, 3mm thick and 38mm wide, complete all as specified & directed.
Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, necessary welding for fixing of butt hinges of any size/any number, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
PCC 1:3:6 nominal mix, type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats and similar items, complete all as specified & directed.
35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
Mild steel pressed handle, oval type, stove enamelled black, 150mm long, complete all as specified & directed.
Mild steel barrel tower bolts, stove enamelled black, with bright bolt, 200mm long, complete all as specified & directed.
Mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less 12mm dia, with and including a minimum of 6 bolts and nuts, 4 on bolt plate and 2 on stapple plate, 300mm long, complete all as specified & directed.
Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, complete all as specified & directed.
Removing excavated material to a distance exc. 50m but n exc 150m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
75mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Machine Pressed precast concrete interlocking paver block any shape and size M-35 Grade, 60mm thick confirming to IS-15658-2006 with grey cement and pigments laid over and including 50mm thick sand cushioning, complete all as specified & directed.
100mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in pavement, hard standing, path etc, surface finished even and fair, laid in alternate bays including form work, complete all as specified & directed.
100mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Aluminium floor dividing strips, 1.5mm thick and 100mm wide, complete all as specified & directed.
Forming embankments of soils including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc 1.5m high from base, complete all as specified & directed.
Walling of random rubble stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6, uncoursed, complete all as specified & directed.
Raised pointing to random or polygonal rubble masonry, uncoursed or brought up to courses in cement mortar 1:3, complete all as specified & directed.
Hand packing (any thickness) using broken stone or boulders at back of walls over arches etc., and raising (or lowering) to the required level, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, fixed in retaining wall for weep hole, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in surface channel and drains including necessary form work, complete all as specified & directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 59 above but for one 3/5 pin 5 Amps socket outlet on same board.
All as per Srl item No. 59 here-in-before but for one 3/5 pin 5 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Inverter LED lamp 6500K, 900lm in white colour of 9 watt, base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 8 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, single pole & neutral, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .