Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹30 L
EMD Value
₹30,000
Closing Date
26 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
COMMISSIONER TIRUNELVELI
1 Sn High Road Tirunelveli Municipal Corporation
Supply, Installation, Testing and Commissioning of Partial-Flow Measurement System (Ultrasonic Cross-Correlation Multi-level Velocity, Level Measurement and 3D Pipe Modelling) for Vertical / Horizontal-Drop Sewer Pipelines of 450 mm, 700 mm and 1000
2026_MAWS_712251_1
13/2026-27
Open Tender
Maintenance Works
Works
1 Sn High Road Tirunelveli Municipal Corporation
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹30,000
1 Sn High Road Tirunelveli Municipal Corporation
9 Oct 2026
9 Oct 2026
26 Oct 2026
9 Oct 2026
26 Oct 2026
9 Oct 2026
21 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, configuration and commissioning of a partial-flow measurement system for heavily polluted sewage in gravity pipelines of nominal pipe diameters 450 mm comprising a suitable transmitter, ultrasonic cross-correlation multi-level velocity sensor or equivalent multiple-flow-velocity technology, level measurement arrangement, pipe nozzle/sensor mounting assembly, sensor cables and accessories, weatherproof field/control enclosure, power supply and surge protection, communication interface/gateway wherever required, and complete 3D pipe and measurement-section modelling to establish the appropriate sensor installation arrangement and hydraulic measurement section. The system shall be suitable for measurement under variable sewage levels and flow conditions and shall include all necessary accessories, engineering, installation, configuration, testing, calibration and commissioning required to provide reliable flow measurement including all cost etc., complete. | 1 | Nos | 103 | ₹103 |
| 2 | Supply, installation, configuration and commissioning of a partial-flow measurement system for heavily polluted sewage in gravity pipelines of nominal pipe diameters 700 mm comprising a suitable transmitter, ultrasonic cross-correlation multi-level velocity sensor or equivalent multiple-flow-velocity technology, level measurement arrangement, pipe nozzle/sensor mounting assembly, sensor cables and accessories, weatherproof field/control enclosure, power supply and surge protection, communication interface/gateway wherever required, and complete 3D pipe and measurement-section modelling to establish the appropriate sensor installation arrangement and hydraulic measurement section. The system shall be suitable for measurement under variable sewage levels and flow conditions and shall include all necessary accessories, engineering, installation, configuration, testing, calibration and commissioning required to provide reliable flow measurement including all cost etc., complete. | 1 | Nos | 104 | ₹104 |
| 3 | Supply, installation, configuration and commissioning of a partial-flow measurement system for heavily polluted sewage in gravity pipelines of nominal pipe diameters 1000 mm, comprising a suitable transmitter, ultrasonic cross-correlation multi-level velocity sensor or equivalent multiple-flow-velocity technology, level measurement arrangement, pipe nozzle/sensor mounting assembly, sensor cables and accessories, weatherproof field/control enclosure, power supply and surge protection, communication interface/gateway wherever required, and complete 3D pipe and measurement-section modelling to establish the appropriate sensor installation arrangement and hydraulic measurement section. The system shall be suitable for measurement under variable sewage levels and flow conditions and shall include all necessary accessories, engineering, installation, configuration, testing, calibration and commissioning required to provide reliable flow measurement including all cost etc., complete. | 1 | Nos | 105 | ₹105 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
2biddocument.pdf
Tender Documents • 0.66 MB
BOQ_855588.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .