Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.4 L+₹32,913 (1.43%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹24.7 L+₹1.6 L (7.08%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹29.7 L+₹6.6 L (28.7%)Rejected-AOC H NO 24 BEHIND GURUDWARA JUTOGH CANTT SHIMLA HP 171008 | SHIMLA | HIMACHAL PRADESH | 171008 | L4 | Rejected-AOC Other than lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Rahul Meena, IDSE, EE, Garrison Engineer
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
WELCOME MAINT OF MD ACCN AT MIL STN DAGSHAI UNDER GE KASAULI
2023_MES_588600_1
GEK-03/2023-24
Open Tender
Miscellaneous Works
Item Rate
330 days
DAGSHAI UNDER GE KASAULI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹70,000
Yes
3 Jul 2023
8 Apr 2023
15 May 2023
8 Apr 2023
8 May 2023
24 Apr 2023
Amount
Schedule 'A' Section - I
M & L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete including taking down cement plaster on brick or stone wall and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specified and directed.
M & L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete including taking down cement plaster on brick or stone wall and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:3 on ceiling brick/concrete surfaces w/o using extra cement including taking down cement plaster on Ceilling and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specified and directed.
M&L for preparation of plastered or unplastered old surfaces of walls and above but one coat of cement based paint on walls complete all as specified and directed.
M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfaces by washing, rubbing down and stopping of previously treated surfaces and applying two coat of cement base paint over a coat of primer on walls complete all as specified and directed.
M&L for for applying 1 mm thick wall care putty of old decorated plastered or unplastered surfaces of wall complete all as specified and directed.
M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of oil bound distemper of any approved tint complete all as specified and directed.
M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfaces by washing, rubbing down and stopping of previously treated surfaces and applying two coat of oil bound distemper of any approved tint over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered ceiling surfaces or AC plain building board surfaces and applying one coat of oil bound distebmer complete all as specified and directed
M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) all as specified and as directed.
All as per item No 10.00 above but applying two coat of synthetic enamel paint complete all as specified and directed
M&L preparation of old painted steel surfaces exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
All as per itme No 12.00 above but two coat of synthetic enamel paint complete all as specified and directed
M&L preparation of new plastered ceiling surfaces or complete removal of existing treatment in old plastered ceiling surfaces by washing, rubbing down and stopping of previously treated surfaces and applying two coat of white wash on wall complete all as speciifed and directed.
M&L for preparation of old plastered ceiling surfaces or AC plain building board surfaces and applying one coat of white wash complete all as specified and directed.
M&L preparation of old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying one coat of synthetic enamel paint of any tint as approved complete all as specified
ditto as per item No 16.00 above complete removal of existing treatment and applying two coat of synthetic enamel paint over a coat of primer
M&L preparation of old painted plastered wall surfaces and applying one coats of synthetic enamel paint of approved tint complete all as specified
All as per item No 18.00 but applying two coat of synthetic enamel paint complete all as specified and directed
M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of exterior emulsion paint complete all as specified and directed
M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfaces by washing, rubbing down and stopping of previously treated surfaces and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make complete all as specified and directed.
M&L disconnecting existing over head steel/PVC water tanks, setting aside (or lowering, if required) for repairs, cleaning etc and hosting if required, reconnecting and refixing in position including cleaning and removing all a scale and dirt etc from tanks and from mouth of circulating pipes etc capacity exc 250 ltrs but n. exc 500 ltrs complete all as specified and as directed.
All as per item No 22.00 above but exc 500 Ltrs and n exc 1000 Ltrs capacity complete all as specified and directed
Writing letters or figures ( block , Roman , Italic , indian) n.exc 30cm height all as specified and directed.
Writing Stops , commas, short lines dashes hyphens,brackets etc all as specified and directed.
Taking down chowkats or frames n.exc. 1.5 Sqm each but without taking off shutters from the frames
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 sqm each but without taking off shutters from the frames
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. →
S & F 35 mm thick factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete, all as specified .
S & F 35 mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc ( without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a), supplied and fitted to chowkats.
M&L 2nd class hardwood as in plain, solid straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed
M & L for two coats of synthetic enamel paint over coat of pink primer on new wooden surfaces of any description not otherwise described over 10 Cm width or girth including preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC 1:2:4 type B0 (using 12.5 mm graded stone agg as in chajja at any height complete including demolition of RCC in chajjas including necessary scaffolding up to a height of 12 mter all as specified and as directed.
Use and waste form work to chajjas chulla hoods troughs and similar items including edges at any height rough finished flat surface complete all as specified & directed.
M&L for providing fabricating placing in position new reinforcement of any size as per site requirement including securing and anchoring and drilling holes inserting the ends and welding if required etc complete all as specified and dircted(Dowel pins willl not paid seperately)
S&F extruded aluminium alloy handles of size 150 mm fabricated type omplete all as specified and as directed.
S&F 200 mm aluminium anodised barrel tower bolts of extruded section etc complete all as directed.
S&F 100mm mild steel butt hinges, cold rolled medium weight.
S & F for galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge.
S&F 250 mm aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) etc complete all as directed.
M & L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment all as specified.
Material and labour for Glazed ceramic coloured tiles in vertical surfaces exc 0.08sqm and n exc 0.16sqm, 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed.
M&L for 16 to 18 mm thick granite stone machine cut (table rubbed & polished) in one piece as in steps,jambs,pillars,windows cills,cooking platform and similar work bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing including making hole in platform complete all as specified.
Demolition stone slabs or tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified.
S&F in repair 15mm bore angle cock, chromium plated, brass, fancy type, screwed both ends for iron pipe or for union etc complete all as specified and directed.
S&F in repair 15mm bore PVC connection with brass nut of length 450mm etc complete all as specified and as directed.
S&F in repair 15mm bore Bib taps, chromium plated cast copper alloy, fency type with crutch or butter fly handle, screwed down for iron pipe or for brass ferrule etc complete all as specified and directed.
S&F in repairs PVC waste down pipe 32 mm bore etc complete all as specified and directed.
S&F in repairs 32mm chromium plate coupling for WHB complete all as specified and directed.
S&F in repairs 40mm chromium plated waste coupling for kithen sink complete all as specified and directed.
S & F in repair for 15mm bore pillar tap fancy type, cast copper alloy chromium plated screwed down, high pressure with crutch or butter fly handle etc complete all as specified and directed.
S&F in repair 15 mm bore brass Chromium plated wall/basin/sink mixer for mixing hot & cold water screwed down for iron pipe etc complete all as specified.
S & F in repair CP soap dish fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed by the Engineer-in-Charge
S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S&F in repair CP toilet paper holder all as specified and as directed.
S&F in repair Towel rail 600mm long chromium plated fixed in and including chromium plated brass screws and wooden/plastic cleats etc complete all as specified.
S&F as in repair fixing WC Orissa pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) includung provision of lime concrete bedding and PVC S trap of 110 mm dia etc complete all as specified and directed by Engr-in-Charge.
S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets 10 Ltrs capacity complete all as specified complete all as specified and directed by Engr-in-Charge
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts,) complete incl making good to floor to match with adjoining surfaces including plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated of aluminium hinging device etc complete all as directed by Engr-in-Charge
S&F for 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified. Including taking up or down steel tubing and connections upto 15mm bore.
S&F for 20 mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified. Including taking up or down steel tubing and connections upto 20 mm bore.
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completed and as directed by the Engr-in-Charge
M & L for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completed and as directed by the Engr-in-Charge
S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to laid in trenches or in floors/wall complete all as specified and as directed by the Engineer-in-Charge
S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and as directed by the Engineer-in-Charge
S&F PVC(SWR) bend 110mm dia bore complete all as specified and directed by Engr-in-Charge
S&F PVC(SWR) bend 75 mm dia bore complete all as specified and directed by Engr-in-Charge
S & F in repair 100 mm dia CP grating plain including jointing with solvent cement.
S&F in repair 75 mm dia PVC(SWR) floor trap, with grating including jointing with solvent cement etc complete all as specified.
S&F in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm etc complete all as specified.
S&F aluminium anodised 4 pin cloth hook hanger fixed to wall complete all as specified and as directed.
Dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Charge
Dismantling wrought iron or mild steel work of any description any position not otherwise provided complete all as specified
M & L for 6 mmPlywood, grade BWR, type BB, fixed with screws to timber frame work all as specified including dsmantling of wall and ceiling board (fibre, pulp, insulation, etc) or insulationboards etc,, any thickness etc. including cover fillets complete
M&L for 18/19 mm block boards,interior grade, fixed with screws to timber frame work complete all as specified. including dsmantling of wall and ceiling board (fibre, pulp, insulation, etc) or insulationboards etc,, any thickness etc. including cover fillets complete
M&L 6mm thick teak wood lipping for block board or veneered plywood 18/19mm thick, fixed with nails in repairs complete all as specified and directed.
Material and Labour for 2nd class hard wood (Hollock) Plain fillets Exc6 & n. exc 13 sq.cm square, rectangular or triangular in section, clean sawn, secured with nails or brads,complete including dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Charge all as specified.
S&F for 0.9 mm thick decorative laminate type 1 of surface finish colour and pattern as approved, fixed with approved adhesive as per specified and as directed
M& L for PVC edge strip of 18/19 mm wide, colour and pattern as approved fixed with adhesive as per specified and as directed
S&F in repair Continuous (piano) hinges,mild steel, bright finish or elec trogalvanised bright finish width of flaps(when open) 30 mm complete all as specified.
S&F 100 mm long extruded stainless steel handle fabricated type anodised, complete all as specified.
S&F Hasp and staple, safety type,of aluminium anodised including bolt to hinge plate and fixed with screws 100 mm size complete all as specified.
S&F magnetic steel stopper catcher holder for cup board of approprite shape and size all as directed.
Material and Labour Framed work such as grills, gratings,railing etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified.
Material and Labour for Welded steel wire fabric n.exc 4 Kg/Sqm supplied and fixed complete to wood or steel members complete all as specified.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified & directed complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:4:8 type D-2 ( using 40mm graded stone aggregate) as in sub base floor and in foundation including necessary form work complete all as specified and directed.including demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials )
M&L for PCC Type B1 1: 2:4 (20 mm graded stone aggregate ) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as in coping ,kneelers , appex stone, coping etc .including demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials )
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment set and jointed in neat cement slurry over 20 mm thick cement screed in CM 1:6 all as specified.all as specified and as directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment set and jointed in neat cement slurry over 20 mm thick cement screed in CM 1:6 all as specified.all as specified and as directed
M&L for Chequered cement concrete tiles 30 cmx 30cm x 25 mm thick, with grey cement and pigment set jointed and pointed in neat cement slurry over and including 20 mm thick screed bed in CM 1:6 in floors with grey cement and pigments complete all as specified and directed
Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
Material and labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed, copper conductor cable in and incl PVC casing -n-caping of any size/dia medium grade complete with all accessories/fittings, brass screws, washer etc and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :-
One light /Exhaust fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed.
One bell point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed.
One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed.
One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed.
One two way point controlled by two, two way switches 06 Amps complete all as specified and directed.
All as per serial item No 97.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06 Amps socket outlet point on independent board complete all as specified and directed.
All as per serial item No 97.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSH PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc,and including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :-
One light / Exhaust fan point controlled by one, one way switch 06 Amps complete all as specified and directed.
One bell point controlled by one, one way switch 06 Amps complete all as specified and directed.
One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed.
One 3 pin,06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed.
One two way point controlled by two, two way switches 06 Amps complete all as specified and directed.
All as per serial item No 99.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06 Amps socket outlet point on independent board complete all as specified and directed.
All as per serial item No 99.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed.
Supply & fixing modular switch 1module, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
Supply & fixing socket, 06 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
Supply & fixing modular switch 1module,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
Supply & fixing socket, 06/16 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
Supply and fixing modular bell push 1module, 06 amps , 240 volts all as directed by Engr-in-Charge
Supply and fixing door bell ding dong type , 240 volts AC
Supply & fixing modular switch 1module, 06 Amps single pole, two way 240 volts complete all as specified & directed. by Engr-in-Charge
Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge
Supply and fix LED lamp 9/10 watt complete all as specified and directed.
Supply & fixing in repair LED tube light batten fitting 18/20W, (single Side Connection) including LED Rod including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply & fixing/fixing in repair LED mirror light 10W including rod complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing in repair of 9/10 W LED bulk head luminairies incl LED light with clear prismatic diffuser,driver holder connecting up with three core flexible copper conductor cable of suitable size including all acessories for fixing on wall all as specified and directed by Engr-in-Charge.
Supply and fixing wall mounted decorative fancy light fitting stylo (Round) suitable for 14 watts LED lamp including provisson of fixing on wall with all items required for fixing all as specified and directed by Engr-in-Charge.
Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed by Engineer - in - Charge.
Material and labour for sub main wiring with 2x4 Sqmm nominal cross sectional area (two single core cable of 4 Sqmm for Phase and neutral + o1 single core cable of 2.5 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.
Ditto all as item No 116.00 above, but by using two single core cable of 6 Sqmm for Phase and neutral + 1 single core cable of 4 Sqmm for earth wire.
Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
All as per item No 119.00, herein before but of size 08 way SPN.
All as per item No 119.00, herein before but of size 12 way SPN.
Supply and fixing MCB, SP, AC, 240 volts "C" series capacity of 06 to 32 Amps, 10kA and making connections with suitable thimble complete all as specified & directed.
Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity 20 Amps to 32 Amps 10kA and making connections with suitable thimble complete all as specified & directed.
Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity 40 Amps to 63 Amps 10kA and making connections with suitable thimble complete all as specified & directed.
Supply and fixing sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision of four pole 100 Amp isolator and MCBs of cap 20 to 40 Amps as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
Supply & fix Isolator 4 Pole 'C' series 100 amps capacity AC 415 V,10kA complete all as specified and directed.
M & l for Sheet metal enclosure fiiting on wall and making the connection with provison of MCCB 4 Pole 100 Amps 25 KA, 415 volts , 50 Hz ,thimble/lugs, aslo including all nuts bolts required for fixing all as specified and directed by Engineer - in - Charge
Supply & fixing industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 32 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
Taking down carefully under ground cable of any size and making good to disturbed surface as per existing complete all as specified and directed.
Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 25 Sqmm 3.5 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed.
-ditto- all as per item No 131.00, but 16 Sqmm 2 core
-ditto- all as per item No 131.00, but 10 Sqmm 2 core
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in hard/dense soil and gating out in hard/dense soil complete all as specified and directed.
Supply / laying and fixing 50 mm bore HDPE pipe PN10 with all fittings laid in trenches for cable protection complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft / loose soil complete all as specified and directed.
Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed.
Taking down the geyser of 25/ 50 ltr capacities from the site after disconnecting the water connection, electric connection, opening the geyser assembly and descalling deposited in the inner container and outlet water pipe set complete all as directed by Engineer-in-Charge. (Note:- Replacement of Unserviceable bolts, rubber real, ring nuts, washers to be included in the rate quoted by tenderer. However supply & fix or material & labour for GI fittings and other connected works shall be measured and paid for separately under respective items of schedule ‘A’ here in after) :-
Supply & fix in repair of geyser syphon assembly steel plate with nuts and bolts, washers, clamps and rubber ring any Make of geyser, for 25/50 ltr capacity of Geysers.
Supply & fix in repair of thermostatic switch 11 " long ISI marked complete with electric connection suitable for geyser any Make complete all as specified and directed.
Supply & fix in repair of geyser element 1.5 /2.0 KW capacity with rubber ring Round/trangular type complete with clamps, nuts and bolts washers etc for geysers ISI marked (any Make) complete all as specified and directed.
Supply and fix Non return valve 15mm dia made of bronze ISI marked heavy duty fixed in repairs complete all as directed by Engineer-in-Charge.
Supply & fix (in repairs) 15mm dia PVC connection 450 mm long , suitable for hot water supply ,complete with 2 Nos brass nuts complete all as specified and directed.
Supply & fix (in repairs) 15mm dia PVC connection 450 mm long , suitable for cold water supply ,complete with 2 Nos brass nuts complete all as specified and directed.
Supply & fix in repairs of Zebra fastner of size 12x100 mm complete all as specified and directed .
Taking down of the following accessories in repair works including all necessary fitting items such as screw, nut and bolt, connector, flexible copper wire 1.5/2.5Sqmm size etc including cheking/testing complete as directed by Engr-in-Charge :-
Supply & fixing modular switch 1module, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
Supply & fixing socket, 06 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
Supply & fixing modular switch 1module,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
Supply & fixing socket, 06/16 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
Supply and fix in repair lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge
Supply and fix in repair white cover plate with frame 1 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair white cover plate with frame 2 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair white cover plate with frame 3 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair white cover plate with frame 4 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair white cover plate with frame 6 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair white cover plate with frame 8 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair metal flush box 1/2 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair metal flush box 2 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair metal flush box 3 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair metal flush box 4 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair metal flush box 6 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair modular switch socket combination16 A, 6 pin, 3 module complete all as specified & directed by Engr-in-Charge
Supply and fix in repair modular switch socket outlet 03 pin 06 A, flush type complete all as specified & directed by Engr-in-Charge
Supply and fix in repair modular switch socket outlet 03 pin 16 A, flush type complete all as specified & directed by Engr-in-Charge
S&F in Replacement Exhaust Fan 250mm plastic body , 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed
S&F in Replacement Exhaust Fan 300mm Sweep metal body (Heavy Duty), 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed.
M&L for electric insulation tape heavy duty complete all as per specifed and directed.
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
Supplying and fixing Meter Box made up of BWR plywood board of 8mm thickness covered with 3mm thick laminated sheet, size of the box shall be of 900mm x 450mm x 250mm including provision of shutters with lock and clasp complete and fixed as directed by Engr-in-Charge.
Amount of credit of Rs. 31871.10 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
R. P. Suppliers and Construction Co.
Sagar Builders
M/S J.S.ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .