Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹1.6 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.7 Cr+₹11.6 L (7.47%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.7 Cr+₹11.6 L (7.47%) | L2 | Rejected-Finance Not being lowest |
| 3 | Rejected-Technical H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | - | - | Rejected-Technical As per technical evaluation enclosed |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per technical evaluation enclosed |
| 5 | Rejected-Technical | - | - | Rejected-Technical As per technical evaluation enclosed |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
10 Oct 2024, 6:00 pmClosed
CWE Udhampur
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
MODERNISATION OF WATER SUPPLY SYSTEM AT MAP ACCNs AND UPGRADATION OF WATER SUPPLY SYSTEM AT CERTAIN LOCATIONS UNDER GE (UTILITIES) UDHAMPUR
2024_MES_650845_3
CWE/U(U)-88/23-24
Open Tender
Miscellaneous Works
Item Rate
365 days
Udhampur
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (UTILITIES) UDHAMPUR
₹2.2 L
Yes
27 Dec 2024
27 Sept 2024
17 Oct 2024
27 Sept 2024
10 Oct 2024
5 Oct 2024
Amount
Supply and fixing of Central Processing Hardware having the following specifications 7th generation Intel core TM i5 7200U Processor (3M cache up to 3.10GHZ, Operating System: Geniune Windows 10 Home Plus / 64Bit. MS office latest, Memory 8GB single channel DDR4 2400MHZ(8GBx01), Hard drive- 2TB,1400RPM, Graphic card-NVIDIA G Force 920MX with 2 TB GDDR5 Graphics with Anti Virus as recommended by the SCADA manufacturer and comprising of :- a) Optical drivetray DVD drive b) LED Monitor 19" c) Wireless keyboard and mouse d) One year hardware warranty e) USB 2.0 RJ45, audioline out DC power along with HDMI port f) Suitable speaker 2.1 system. g) UPS of suitable capacity for battery backup of min 30 minutes.
Supply, Installation, Testing and Commissioning of SCADA software as runtime with unlimited tags/Screens for monitoring and automated control for complete water supply system in Sansar Chand Vihar, Albet Ekka Enclave and Naubat Ram Vihar including all UG sumps, OH Tanks, Pumps, motors, valves and any other equipments deemed necessary to be installed and deployed on the stand alone PC along with report generation on daily, weekly, monthly and yearly wise auto generated report software and historian software with licence. Note: Price inclusive of Development of all screens and all necessary communication cables.
Supply, Installation, Testing, and Programming of PLC based MIMIC PANEL of a minimum size 3000 (W) x 2000 ( H ) x 250 (D) (min) made out of 2mm CRCA sheet as per 61439 Part I &II type tested assembly. Panel shoud have all properly polished depicting in realtime status of all pumps and operational valves along with the level of water in Semi- Underground sump at Pump house Overhead Tank at Buildings. The panel shall be provided with LED Lighting to facilitate viewing in times of emergency alongwith suitable power UPS backup for 12 Hours and the distribution diagram shall be synchronised in real time with Water Supply distribution panel. The front facia of the Panel shall be made out of ink jet printed laminated Latex on Vinyl to clearly depict the layout of the water supply system in schematic format. The Panel shall consist :- (a). suitable number of input and outputs, (b). LEDs with LED holders, drivers of suitable size / capacity, (c). SMPS (24V / 5A) and MCB of suitable rating, (d). MIMIC PANEL PVC COVER (transprent) of suitable size to avoid dust ingress, (e). UPS 1000VA with 12V DC 180AH Battery (02 Nos) for 08 hour backup. Note : The complete layout of MIMIC Panel including all parametrs that are to be indicated to be approved by Engr-in-Charge before built of panel.
Supply, Installation, Testing and Commissioning of a suitable OPC server for unlimited tags with MODBUS TCP/equivalent driver having provision for IOT gateway to exchange data between the PLC based panels to be installed at site and the SCADA system complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Static IP with Broadband connection by the name GE(Utilities) Udhampur of any service provider of excellent speed.for the period of 2 year from date of completion of work. Note: Connection, Hardware and service charge for the complete functioning of the system deemed to be included in the quoted rate.
Supply installing, connecting, testing and commissioning of indoor PLC (Programmable Logic Controller) based Master monitoring / Annunciating control Panel and automation compatible pump motor starter panel at Albert Ekka Enclave. PLC panel of adequate size having degree of ingress protection IP-54, cubicle type, floor mounted made out of 2.0 mm thick CRCA sheet as per 61439 Part I &II type tested assembly. MS angle section 50mmx50mmx6 mm frame & compartmentalized for following equipments controls and door etc with front openable, single door system lockable/openable by keys from front side having flush pattern fancy locks with louvers & air vent gasket for natural flow of air for 1 phase, 2 wire, 240 volts, 50 Hz and CPRI approved make, factory made in approved factory duly powder coated externally as well as internally provided with suitable ''U'' type gasket to make it dust and vermin proof & genral construction confirming to IS:8623/93, with provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder piller box safely including containing of detachable plate having provision for entry of armoured cable of adequate size with glands and mounted on a powder coated metal stand including and other jointing/ Plugging material as:- (A) Motorised Valve of distribution header and sump ( 06+01 Nos) (B) Magnetic level Sensor for Semi UG sump (01No) (C) Pump sets (02 Nos)
Supply, installing, connecting, testing and commissioning of PLC (Programmable Logic Controller) based Master monitoring/ Annunciating control Panel and automation compitable pump motor starter panel at Naubat Ram Vihar. PLC panel of adequate size having degree of ingress protection IP-54, cubicle type, floor mounted made out of 2.0 mm thick CRCA sheet as per 61439 Part I &II type tested assembly. MS angle section 50mmx50mmx6 mm frame with sloping roof top type panel cover & compartmentalized for following equipments controls, and door etc with front openable, single door system lockable/openable by keys from front side having flush pattern fancy locks with louvers & air vent gasket for natural flow of air for 1 phase, 2 wire, 240 volts, 50 Hz and CPRI approved make, factory made in approved factory duly powder coated externally as well as internally provided with suitable ''U'' type gasket to make it dust and vermin proof & genral construction confirming to IS:8623/93, with provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder piller box safely including containing of detachable plate having provision for entry of armoured cable of adequate size with glands and mounted on a powder coated metal stand including and other jointing/ Plugging material complete with comprising of the following:- (a) Motorised Valve of distribution header and sump ( 06+01 Nos) b) Magnetic level Sensor for Semi UG sump (01No) (c) pump sets (02 Nos)
Supply, installing, connecting, testing and commissioning of PLC (Programmable Logic Controller) based Master monitoring/ Annunciating control Panel and automation compitable pump motor starter panel at Sansar Chand Vihar. PLC panel of adequate size having degree of ingress protection IP-69, cubicle type, floor mounted made out of 2.0 mm thick CRCA sheet as per 61439 Part I &II type tested assembly. MS angle section 50mmx50mmx6 mm frame with sloping roof top type panel cover & compartmentalized for following equipments controls, and door etc with front openable, single door system lockable/openable by keys from front side having flush pattern fancy locks with louvers & air vent gasket for natural flow of air for 1 phase, 2 wire, 240 volts, 50 Hz and CPRI approved make, factory made in approved factory duly powder coated externally as well as internally provided with suitable ''U'' type gasket to make it dust and vermin proof & genral construction confirming to IS:8623/93, with provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder piller box safely including containing of detachable plate having provision for entry of armoured cable of adequate size with glands and mounted on a powder coated metal stand including and other jointing/ Plugging material complete with comprising of the following:- (a) Motorised Valve of distribution header and sump ( 06+01 Nos) (b) Magnetic level Sensor for Semi UG sump (01No) (c) pump sets (02 Nos)
Supply, installing, connecting, testing and commissioning of design automation Panel of adequate size having degree of ingress protection IP-69, cubicle type, floor mounted made out of 1.8 mm thick CRCA sheetas per 61439 Part I &II type tested assembly. The panel builder should be channel partnet of ABB/L&T/Siemens, MS angle section 50mmx50mmx6 mm frame with sloping roof top type panel cover & compartmentalized for following equipments controls, and door etc with front openable, single door system lockable/openable by keys from front side having flush pattern fancy locks with louvers & air vent gasket for natural flow of air for 1 phase, 2 wire, 240 volts, 50 Hz and CPRI approved make, factory made in approved factory duly powder coated externally as well as internally provided with suitable ''U'' type gasket to make it dust and vermin proof & genral construction confirming to IS:8623/93, with provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder piller box safely including containing of detachable plate having provision for entry of armoured cable of adequate size with glands and mounted on a powder coated metal stand including and other jointing material complete with comprising of the following:- a) Magnetic level Sensor for OHT water level control (01 to 05 Nos as per site requirement) b) Single phase motorised operating valves control (01 to 05 Nos as per site requirememts)
Supply, Installation, Testing and commissioning of Flow/Pressure Switch of designed line pressure 1-10KG/sq.cm with Pressure Guage and necessary fittings with proper wiring and to be fixed in deliver line of each pump sets as directed by Engineer in charge.
Supply, Installation, Testing and commissioning of Rust proof, maintenance free Magnetic float switch sensors for OH tanks with following specifications: Principle: Magnetic, Magnet: Ferrite Ring: Float and Guide: ABS, Switch: Reed , Connection cable: 2 core Teflon Cable and to be fixed in each over head tank/semi UG sumps as directed by Engineer in charge. Note: 47 Nos for Bldgs and 03 Nos for semi UG sump and each tank have two sensors..
Supply, Installation, Testing and commissioning of Air releasing solenoid valve having 10mm dia, 230 V AC operated coil complete all as specified & directed.
Supply, Installation, Testing and commissioning of Priming solenoid valve/ Actuator having 25mm dia, 230 V AC operated coil complete all as specified & directed.
Supply, Installation, Testing and commissioning of motor actuated butterfly valve with the following specifications including all accessories (CI/GI/MS fittings required at site) complete as directed by Engineer-in-Charge. (a) Valve size 80mm dia. (b) Designed line pressure 8 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve/ Extended type as per site requirement. (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel/Rapid Control
Supply, Installation, Testing and commissioning of motor actuated butterfly valve with the following specifications including all accessories (CI/GI/MS fittings required at site) complete as directed by Engineer-in-Charge. (a) Valve size 150mm dia. (b) Designed line pressure 8 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve/ Extended type as per site requirement. (g) Input Supply : 230V, AC, 50 HZ (h) Inbuilt wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel/Rapid Control
Supply, Laying/ Fixing on wall 6 core, 1.5 sqmm cross sectional area armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified.
Supply, Laying / Fixing on wall 4 core, 1.5 sqmm cross sectional area copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified.
Supply, Laying/ Fixing on wall 2 Pair, 0.5 sqmm cross sectional area copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified.
Supply, Laying/ Fixing on wall 2 core, 1.5 sqmm cross sectional area copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified.
Excavating in trenches not exc 1.8 metre wide and not exc 0.6 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in loose/ soft soil.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Cutting of existing road/ Path/ Hard standing for crossing of DWC Tubing for laying of any size pipes including necessary exacavation and earth work including repairing the same as per existing with pre mix bituminuos carpet complete all as specified and directed.
Supply, Laying/ Fixing on wall DWC tubing of size 40/32 mm dia for laid in trenches for protection of cables complete all as specified and directed.
Supply and fixing of Snap- Fit Coupler for jointing of DWC tubing of size 40/32 mm dia complete all as specified and directed.
Supply Laying Fixing on wall of DWC tubing of size 40/32 mm dia for protection of cables complete all as specified and directed including all fittings and fixed to walls of buildings with required size of flat iron clamps, bolts, nuts and washers for protection of DWC complete all as specified and directed.
Supply, Installation, Testing and Commissioning of A3 size Laserjet Printer. Print speed black: Up to 14 ppm Print technology: Laser, Processor speed 234 MHz Connctivity: included components Laser Jet Print Cartridge, Getting Started guide, Printer documents and Software on CD-ROM, power cord.
Shree Ayyappa Engineering (BID ID -3135685)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .