Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
27 Feb 2021, 3:00 pmClosed
OFFICE OF THE EXECUTIVE ENGINEER (SDW)-III
STP YAMUNAVIHAR, WAZIRABAD ROAD DELHI-110053
Electrification of newly constructed security check posts and washroom at STP Ph-I, Ph-II and Admin block, Yamuna Vihar.
2021_DJB_200339_1
NIT No. 10 (20-21)
Open Tender
Miscellaneous Works
Works
60 days
Yamuna Vihar.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹4,000
Yes
8 Mar 2021
19 Feb 2021
27 Feb 2021
19 Feb 2021
27 Feb 2021
19 Feb 2021
PART A:- External lighting. Supply and fixing of 32mm dia. 02 Mtrs. long G.I pipe (medium class) bracket for mounting of fluorescent/HPMV/HPSV street light fitting on pole/ wall including bending the pipe to the required shape, 2 Nos. 40mmX3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Providing of LED street light of 45 watt complete IP66 protection and impact resistance of 1K07. Make:- Havells/ Bajaj/Crompton/Phillips.
Providing of 2X 10 Sq mm PVC insulated and PVC sheathed Aluminum armoured cable. Make :- Gloster/ Grandly/ Universal/National
Providing and fixing of pole mounted cable junction box of size having phase bar, neutral bar, din bar along with IP 65 protection with complete accessories as site requirement. Make:- Sintex/hensel
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required.
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as reqd. (clamped with 1mm thick saddle) 2x 10 sq. mm
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
PART B:- Internal lighting. Providing of Endura Surface and wall mounted LED batten, LED tube light 20W/5700 K.20 W LED Make: Havells /Bajaj/ Philips/Crompton.
Providing of exhaust fan of size 200mm sweep, 1250 - 1400 R.P.M of single phase 230 Volt. Make: Bajaj/Crompton/Khaitan/Orient.
Providing of ceiling fan of size 1200mm of single phase 230 Volt. Make: Bajaj/Crompton/Khaitan/Orient.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way, Double door.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
Cantilever Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .