| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | ₹8.2 L Quoted ₹9.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹12.4 LRejected-Finance | ₹12.4 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹13.2 LRejected-Finance | ₹13.2 L | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | YOGINDER KUMAR GUPTA AND COMPANY L3 | M/S GOYAL CONSTRUCTIONS L1 | Aditi Formation Company L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully ceiling fans, exhaust fans, pedestal fans, air circulator fans, wall-mounted fans and flame-proof fans, of any make, type, sweep and size, from various locations/buildings as directed, including disconnecting electrical connections, dismantling where required, careful handling and shifting, and depositing the same in MES E/M store yard, complete all as specified and as directed | 1,200 | EACH JOB | 70 ₹84,000 | 10 ₹12,000 | 70 ₹84,000 |
| 2.00 | M&L for Collecting ceiling fans, exhaust fans, pedestal fans, air circulator fans, wall-mounted fans and flame-proof fans, of any make, type, sweep and size, from MES E/M store yard as directed, transporting the same to the contractor’s workshop within Air Force premises, opening up and dismantling for servicing and repair, removing accumulated dust and dirt, cleaning the fan motor with cotton/waste, washing blades with detergent, inspecting all components, carrying out servicing, oiling and greasing with suitable grade of oil and grease, attending mechanical and electrical defects, undertaking lathe work wherever required, replacing defective petty parts as necessary for smooth and satisfactory functioning, reassembling the complete fans, and depositing the serviced fans back in MES E/M store yard, complete all as specified and as directed | 1,030 | EACH JOB | 70 ₹72,100 | 15 ₹15,450 | 50 ₹51,500 |
| 3.00 | M&L for Collecting serviceble ceiling fans, exhaust fans, pedestal fans, air circulator fans, wall-mounted fans and flame-proof fans, of any make, type, sweep and size, from MES E/M store yard as directed, transporting the same to site, fixing/refixing in original position including providing and fixing PVC flexible conduit pipe 20 mm dia, reconnecting with copper flexible cable to the existing electrical system, carrying out trial run and testing for proper speed and smooth operation to the satisfaction of the Engineer-in-Charge, complete all as specified and as directed | 1,200 | EACH JOB | 70 ₹84,000 | 15 ₹18,000 | 50 ₹60,000 |
| 3.01COMMON NOTES T ITEM NO 02 & 03: (i) Replacement of unserviceable major parts shall be measured and paid separately under the respective items as “Supply only”. The quoted rate under repair/servicing items shall be deemed to include the cost of all petty spares, accessories, consumables, oils, grease, cleaning materials, fasteners, etc., and no extra claim whatsoever shall be entertained during the currency of the contract. (ii) After completion of repair and refixing, each fan shall be tested. If the desired speed, smooth running or performance is not achieved to the satisfaction of the Engineer-in-Charge, the repair work shall be re-done by the contractor at his own cost, and the same shall be deemed to be included in the quoted rates. | ||||||
| 4.00 | Rewinding of 1200 mm sweep Ceiling fan Motor 240 Volt, AC, 50 Hz, of any make with super enamelled copper winding wire of existing size including sleeves work, varnishing with 'B' class insulation varnish complete all as specified and directed.
(NOTE: Motor shall be wound with machine with same or more No of turns as per existing provision). | 570 | EACH | 250 ₹1.4 L | 400 ₹2.3 L | 190 ₹1.1 L |
| 5.00 | -ditto- but for rewinding of 1400 mm sweep ceiling fan | 110 | EACH | 250 ₹27,500 | 400 ₹44,000 | 210 ₹23,100 |
| 6.00 | -ditto- but for rewinding of 300mm sweep exhaust fan | 150 | EACH JOB | 270 ₹40,500 | 250 ₹37,500 | 220 ₹33,000 |
| 7.00 | -ditto- but for rewinding of 380mm-400mm sweep exhaust fan | 100 | EACH JOB | 270 ₹27,000 | 260 ₹26,000 | 230 ₹23,000 |
| 8.00 | -ditto- but for rewinding of 430mm - 450mm sweep exhaust fan | 50 | EACH JOB | 270 ₹13,500 | 260 ₹13,000 | 240 ₹12,000 |
| 9.00 | Supply only Capacitor 2.5 mfd, paper type suitable for fans of any type, make or size, complete all as specified and as directed. | 625 | EACH | 85 ₹53,125 | 40 ₹25,000 | 50 ₹31,250 |
Updated dates
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Feb 2026, 6:00 pmClosed
GE (AF) SIRSA
AIR FORCE STATION SIRSA HARYANA-125055
REPAIR AND MAINT OF VARIOUS TYPE OF FANS ALONGWITH ALLIED WORKS AT AF STN SIRSA
2026_MES_748965_1
GE/SRA/T-69/2025-26
Open Tender
Miscellaneous Works
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹30,000
Yes
20 Feb 2026
17 Jan 2026
6 Feb 2026
17 Jan 2026
5 Feb 2026
24 Jan 2026
Taking down carefully ceiling fans, exhaust fans, pedestal fans, air circulator fans, wall-mounted fans and flame-proof fans, of any make, type, sweep and size, from various locations/buildings as directed, including disconnecting electrical connections, dismantling where required, careful handling and shifting, and depositing the same in MES E/M store yard, complete all as specified and as directed
M&L for Collecting ceiling fans, exhaust fans, pedestal fans, air circulator fans, wall-mounted fans and flame-proof fans, of any make, type, sweep and size, from MES E/M store yard as directed, transporting the same to the contractor’s workshop within Air Force premises, opening up and dismantling for servicing and repair, removing accumulated dust and dirt, cleaning the fan motor with cotton/waste, washing blades with detergent, inspecting all components, carrying out servicing, oiling and greasing with suitable grade of oil and grease, attending mechanical and electrical defects, undertaking lathe work wherever required, replacing defective petty parts as necessary for smooth and satisfactory functioning, reassembling the complete fans, and depositing the serviced fans back in MES E/M store yard, complete all as specified and as directed
M&L for Collecting serviceble ceiling fans, exhaust fans, pedestal fans, air circulator fans, wall-mounted fans and flame-proof fans, of any make, type, sweep and size, from MES E/M store yard as directed, transporting the same to site, fixing/refixing in original position including providing and fixing PVC flexible conduit pipe 20 mm dia, reconnecting with copper flexible cable to the existing electrical system, carrying out trial run and testing for proper speed and smooth operation to the satisfaction of the Engineer-in-Charge, complete all as specified and as directed
Rewinding of 1200 mm sweep Ceiling fan Motor 240 Volt, AC, 50 Hz, of any make with super enamelled copper winding wire of existing size including sleeves work, varnishing with 'B' class insulation varnish complete all as specified and directed. (NOTE: Motor shall be wound with machine with same or more No of turns as per existing provision).
-ditto- but for rewinding of 1400 mm sweep ceiling fan
-ditto- but for rewinding of 300mm sweep exhaust fan
-ditto- but for rewinding of 380mm-400mm sweep exhaust fan
-ditto- but for rewinding of 430mm - 450mm sweep exhaust fan
Supply only Capacitor 2.5 mfd, paper type suitable for fans of any type, make or size, complete all as specified and as directed.
Supply only Capacitor 3.15 mfd, paper type suitable for fans of any type, make or size, complete all as specified and as directed.
Supply only new Anti-suicidal Fan Rod, of any size/length, as demanded by Engineer-in-Charge with Load bearing Capacity 15 to 25Kg comprising / inclusive of the following Specifications :- (a) A pair of Supply Wire (b) Holes for Shackle fitting on Ceiling (c) Hole for Supply Wire bringing out after Inserting Caps (d) Wire to connect to fan motor (e) Hole for Safety screw fittings (f) Holes for Fan Motor Shaft. (MAKE: GOLD LIFE or any other make as approved by GE)
Supply only new Metallic Fan Rod, of any size/length, as demanded by Engineer-in-Charge with Load bearing Capacity 15 to 25Kg comprising / inclusive of the following Specifications :- (a) A pair of Supply Wire (b) Holes for Shackle fitting on Ceiling (c) Hole for Supply Wire bringing out after Inserting Caps (d) Wire to connect to fan motor (e) Hole for Safety screw fittings (f) Holes for Fan Motor Shaft.
Supply only Connection wire consisting of PVC insulated Twin Core twisted copper Flexible Wire of 23/.0076 from connector block to ceiling rose for Ceiling/Exhaust Fan Connection, complete all as specified and as directed.
Supply only Connection wire consisting of PVC insulated Twin Core twisted copper Flexible Wire of 40/.0076 from connector block to ceiling rose for Ceiling/Exhaust Fan Connection , complete all as specified and as directed.
Supply only PVC connector with screws, suitable for ceiling fans complete all as specified and directed.
Supply only up/down Canopy, suitable for Ceiling Fan 1200mm /1400mm Sweep, of any Make or type complete all as specified and as directed.
Supply only Armature for ceiling fan suitable for 1200 mm sweep with prewired copper wound armature complete all as specified and directed.
Supply only Armature for ceiling fan suitable for 1400 mm sweep with prewired copper wound armature complete all as specified and directed.
Supply only holding clamp for capacitor of ceiling fans 1200/1400 mm sweep, any type complete all as specified & directed.
Supply only MS/D Clamps for hanging purpose of ceiling fans with proper rubber reel packing & split pin complete all as specified and as directed.
Supply only Ball Bearing 6201/6202 (as approved), complete all as specified and as directed.
Supply only Ball Bearing 6203/6204 (as approved) , complete all as specified and as directed.
Supply only Bush made up of Gun Metal suitable for Ceiling Fan/ Exhaust Fan / Wall Mounted Fan of any Make and any size, complete all as specified and as directed.
Supply only Metallic Fan Blades, duly spray painted / powder coated, suitable for 1200 mm sweep Ceiling Fans of any Make, complete all as specified and directed.
-ditto- but metallic fan blades suitable for Ceiling Fans, AC, 1400mm Sweep
S&F Metallic Blades, comprising of three blades, duly painted, suitable for 300 mm sweep Exhaust Fans of any Make, complete all as specified and directed.
-ditto- but metallic fan blade for 380 mm sweep exhaust fan
-ditto- but metallic fan blade for 400 mm sweep exhaust fan
-ditto- but metallic fan blade for 430 mm - 450 mm sweep exhaust fan
Supply only Polycarbonate Fan Blade, comprising of 3 blades, suitable for Wall Mounted Fan, 400mm-450mm sweep, any Make, complete all as specified and as directed.
Supply only Ready Made Metallic Frame suitable for Exhaust Fans, 300mm sweep, of any Make and Type/Shape, duly painted complete all as specified and as directed.
-ditto- but metallic frame for 380-400 mm sweep exhaust fan
-ditto- but metallic frame for 430-450 mm sweep exhaust fan
S&F in repairs Shutters/ Louvers suitable for 300 mm sweep Exhaust Fans, of any Make and Type/Shape, duly painted and fixed on Brick Wall and grouted with Nuts, Bolts and Washers complete all as specified and as directed
-ditt- but shutter/louvers for 380-400 mm sweep exhaust fan
-ditt- but shutter/louvers for 430-450 mm sweep exhaust fan
Supply only ceiling fan, with brushless DC motor (BLDC), 5 Star rated, 1200 mm sweep having minimum 210 CFM air delivery with service value 6.0 alongwith down rod, canopy, fan blades and other accessories and depositing in MES Store complete all as specified and directed.
Supply Only PVC Ventilating Fan, rectangular type, 250mm sweep and depositing in MES Store complete all as specified and directed.
Supply Only PVC Ventilating Fan, rectangular type, 300mm sweep and depositing in MES Store complete all as specified and directed.
S&F new Fan Regulator, 5 Step, Socket type, 100 watt complete all as specified and directed.
S&F Fan Regulator, 5 Step, Piano type, 100 watt complete all as specified and directed.
S&F new Modular Fan regulator, 5 step, 120 watt, 2 module, 230 volts, single pole complete all as specified and directed.
S&F new Modular Fan regulator, 5 step, 120 watt, 1 module, 230 volts, single pole complete all as specified and directed.
M&L for complete painting of ceiling fans, 1200mm sweep, any type or make, with two coats of synthetic enamel paint, tint of paint as per existing with spraying Machine, writing MES No after preparation of surfaces complete i.e. Holding Down Rod, Fan Blades, Fan Body, Canopies and removing old paint by scrapping, cutting, rubbing, etc. and filling of Putty as required, complete all as specified and as directed.
-ditto- but for painting of Ceiling Fan 1400 mm sweep, any type or make
-ditto- but for painting of Metallic Exhaust Fan 250 mm to 300 mm sweep, any type or make
-ditto- but for painting of Metallic Exhaust Fan 380 mm to 400 mm sweep, any type or make
-ditto- but for painting of Metallic Exhaust Fan 430mm to 450 mm sweep, any type or make
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.67 MB
GENINSTRCTIONT-69.pdf
Tender Documents • 2.15 MB
BOQ_838760.xls
BOQ • 0.48 MB
TenderT-69.pdf
Additional Documents • 1.30 MB
CREDIT.pdf
Additional Documents • 0.05 MB
Download all tender documents and submit your bid