Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹38.3 L+₹1.5 L (4.00%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹39.5 L+₹2.7 L (7.38%)Rejected-Finance 0 BINOVA NAGAR KAMRUP ASSAM 781018 UDYAM AS 03 0029196 | KAMRUP METRO | ASSAM | 781018 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹40.6 L+₹3.8 L (10.4%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹42.4 L+₹5.7 L (15.4%)Rejected-Finance W D BUILDING JP ROAD BHARALUMUKH GUWAHATI 781009 ASSAM | KAMRUP METRO | ASSAM | 781009 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
24 Nov 2021, 6:00 pmClosed
GE NARANGI
GE Narangi C/O 99 APO
SPECIAL REPAIR TO SHED NO P42 AND ROOF OF BLDG NO P77 UNDER GE NARANGI
2021_MES_483992_1
8705/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NARANGI
₹84,000
Yes
14 Dec 2021
27 Oct 2021
27 Nov 2021
27 Oct 2021
24 Nov 2021
10 Nov 2021
Amount
Dismantling of plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & as directed.
Dismantling of asbestos cement sheet (Corrugated semi corrugated etc) as in roof covering complete all as specified and directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.60mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.60mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and directed. Note: To be executed for provision of ridges and hips.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 with one shop coat of red oxide zinc chrome primer paint complete all as specified and directed.
S&F Rolled mild steel roof trusses ( framed) trussed purlins, crane gantries, rails and fastenings and heavy brackets framing ( Beam, tee, angle, channel or flat section) including distace pieces, cleats etc confirming to Fe 410-W ( Gde E-250 Quality A)complete all as specified & as directed.
S&F in repair suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner shall not be placed at more than 450mm from the adjacent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
S&F in repair False ceiling with 12mm thick of size 600mm X 900mm Plaster of paris sheets fixed with machine screws on and including GI channel 16 gauge grid work main joists placed at 750mm, centre to centre and cross joists 450mm centre to centre hanging with 6mm dia GI wire suspenders roof " J" hook bolts and nuts and treating the POP sheets with thin layer of POP with gypsum binder till smooth surface is acheived and applying two coats of plastic emulsion paint of approved colour over a coat of primer matching with the colour of ceiling sheets complete all as specified and as directed.
S&F decorative flowers design/ moulding using POP of dia not exceeding 40cm in circular shape as per approved design fixed in position including preparing the surface and applying two coats of plastic emulsion paint over a coat of primer matching with the colour of ceiling sheets complete all as specified and as directed.
S&F decorative cornices/ moulding using POP of cross sectional dimension exceeding 13sqcm and not exceeding 25 sqcm as per approved pattern and design fixed in position including preparing the surface and applying two coats of plastic emulsion paint over a coat of primer matching with the colour of ceiling sheets complete all as specified and as directed.
Demolition of brick /stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M&L for 100mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in floors finishing the surface even and smooth with using extra cement complete all as specified and directed.
M&L for 100mm thick PCC type D-2, 1:4:8(40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection. Plinth protection shall be laid in alternate bays n exc 2 sqm, 10 mm thick joints shall be provided, joint shall be filled with bitumen mastic, bitumen mastic shall comprises of 1 part of hot bitumen 85/25 and 3 parts of sand all by weight finished cement concrete surface even and fair without using extra cement complete all as specified and as directed.
M&L hardcore of gauge n exc. 63mm with broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L in repair Machine pressed precast concrete interlocking paver block with grey cement and pigment of approved design and pattern any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade including 30mm thick sand cushion including spreading screened river sand over surface for filling the joints with rising surface vibrator complete all as specified & as directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound to be measured and paid separately as "Supply only".
Supply only integral water proofing compound complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new wall surface and applying two coats of acrylic exterior weather resistant paint (weather proof paint) of tint as approved over a coat of primer and including applying wall care putty of 1mm thick average thickness complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish not exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 with mixing of WPC and surface finished fare and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle , and steel peg stay complete with glazing bars dovetailed or welded with 12mm dia square bars or round bar of approved design welded to steel window frame including cutting holes in old concrete surfaces and making good in PCC 1:2:4 type B-1 complete all as specified & as directed.
S&F rolled mild steel framed works as in doors or gates of angle or other section with gusset plates,, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hangings also fastening and fixing etcconforming to Fe.290.Gde-E-165.
S&Freinforced sheet glass 4mm thick , ordinary quality and glazing with oil putty in square not exceeding 1.50 sqm in each pane complete all as specified and directed.
M&L for preparation of old surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint r complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
S&F in repairs 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall or in floor as in waste/soil pipe etc complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
Taking down sliding shutter of any type and repairs to defective components/replacement such as sliding system and pulling system, re-assembling the whole sliding shutter including greasing complete, welding drilling where required and refixing the shutter in the same opening complete area of each shutter exc 10 Sqm but not exc 20 sqm each all as directed. All the shutter shall be removed carefully with accessories without damaging the adjacent structures. Contractor shall lay out all the defective parts of removed shutters at site and for approval of Engineer-in-Charge. Defective parts shall be replaced with new fixture/items, which shall be paid under relevent items at supply only rates. All the repairs parts/accessories alongwith new parts/accessories shall be reassembled and fixed to the satisfaction of Engineer-in-Charge in existing position. contractor shall carry out necessary greasing, easing etc for smooth functioning of the shutter, without any extra cost to the department.
Supply only MS Wheel of size 100 x 50 mm in top rail complete all as specified and as directed.
Supply only MS Wheel of size 50 x 25 mm in bottom rail complete all as specified and as directed.
Supply only guide channel made of mild steel deep channel section not less than 3.15 mm thick depth of channel 75 mm complete all as specified and directed.
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point incl. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item No 40 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 40 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 40 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 240 volt complete all as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
S&F switch socket combination outlet , 2-in-1, 5 Amp flush type complete all as directed.
S&F switch socket combination multipurpose, 5 in 1, , 5 & 16 Amp flush type complete all as directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed.
S&F modular stepped type electronic fan regulator, two module size, flush type complete all as directed.
M & L for point wiring for modular fitting with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) drawn through existing conduit of not less than 20mm dia with all fittings and accessories including suitable modular PVC box or pressed steel modular boxes made out of 1.6mm thick mild sttel including cover plate with frame laid /fixed in concealed on walls/ceiling, afor One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item No 51 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 51 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 51 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
All as per item No 51 here-in-before but wiring with 4 sqmm size single core multistranded copper conductor cable for north west modular outlet on independent board with 4 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F modular switch1 module 6 Amps 240 V single pole one way including cover plate with frame 240 volt complete all as directed.
S&F modular socket outlet 3 pin, 2-in-1, 6 Amps 2 module complete all as directed.
S&F modular switch socket combination outlet , 2-in-1, 6 Amp 3 module complete all as directed.
S&F modular switch socket combination multipurpose, 5 in 1, , 5 & 16 Amp 3 module complete all as directed.
S&F in repairs decorative hexagonal bulk head LED luminaire 10Watt,6000K with IP 66 Protection complete as specified and directed. (Make: Havells Model HEXAFT10WLED857SSYMBOPC or equivalent of crompton/Bajaj/Philips)
S&Fin repair regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model No: REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj / Philips / GE / Crompton)
S&Fin repair LED mirror light white cylindrical opal glass E 14 with lamp of 4 Watt high output diffuser complete. Make Jaguar Cat No. JNLWLCYLNDSIE14 or equivalent model of Philips / GE / Crompton)
S&F in repairs wall decorative fixtures in durable plastic body and designer mesh in gold finish suitable for 9 W LED lamp of B-22 including lamp of 9 W complete all as specified and directed. Make : Havells Cat No. LHFOECE1TZ1B014 or in equivalent of Bajaj/CG/Philips
S&Fin repair Destello suspended LED box type fitting pre wired including lLED tube 1X25 Watt connecting up with PVC insulated and sheathed 1100 V grade flexible copper cable with provision of suspension from ceiling (Make:- Havells, Model No: DESTELL0050LP/S25WLED 857 SPMMAWH or equivalent model of make Bajaj / Philips / GE / Crompton)
S&F in repairs round shape 12 Watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F in repairs Exhaust fan 250mm sweep AC single phase 230/240 Volts 50 Hz made of sturdy engineering plastic with louvers shutter complete.Make : Usha/Bajaj/Havells
S&F in repairs round shape 6 Watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing in repairs building security light bracket made of GI pipe 40 mm bore medium grade (bend to shape), 2.00 metre long and fixed with Ms flat iron clamp(clamp shall be 40 x 5mm), nuts, bolts and washers on pole complete all as specified and directed.
Supply and fixing in repair building security liminaires WSPD 48 Watts epoxy powder coated pressure die cast aluminium housing with weather proof gasket for LEDs and control gear compartments, pressure die cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. CRee LED/Equivalent colour temp-5700 K +/-300 K lens , IP-66, lumen efficiancy >100, lm/w. surge protection, 4 KV internal ( built in) with twin core conductor complete all as specified and directed including testing on completeion. Make: Havells Cat No. ENDURAPEARNEOSL48WLED757SASYTOPC or equivalent in Philips/WIPRO/CG.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed.
Taking down ceiling /wall / exhaust fans of any sweep carefully and and transporting from any location to MES E/M store yard and back after repairing and refixing in position duly painted with one coat of synthetic enamelled paint by spraying including filling cavities with filler connecting up after neccessary repair as directed. complete all as specified and directed.
S&F in replacement MCB DB, double door sheet metal enclosure TPN 4 way with 200 A rated bus bar with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in replacement MCCB DB, IP-43, double door sheet metal enclosure VTPN 4 way with 250 Amps rated copper bus bar 415 volt complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCCB 125 Amps, 415V , 16 KA 4 pole complete all as specified and as directed. Make :- Legrand / Siemens/Schnider.
S&F in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked fixing in DBs (DBs catered separately in this Schedule) (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repair MCB Tripple pole & neutral 40 to 63 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M & L in repair for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 3 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L in repair for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
S&F GI tubing 25mm dia light grade for cable protection and fixing to existing pole with mild steel flat iron clamp of size 25x3mm including nuts bolts etc complete all as specified and directed.
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
Taking down carefully by unscrewing from board/outlet boxes, fitting and fixturessuch as switches, sockets,ceiling rose, lamp holders, brackets ceiling fitting ,bulkhead fitting, tube light fitting and regulator etc for reuse at site or carring to the store ( To be measured only when found in all respect complete for reuse) and making good disturbed surface of wall, flooretc complete all as directed by Engineer-in-Charge.
Refixing serviceable fittings/ fixtures as obtained from serial item No. 108 here in before and connecting up with suitable size cable in location as directed.
Supply and fixing in repairs modular north west outlet tiny trip C-25, 2 pole MCB 240 V 50Hz single phase motor startar current range from 11 Amp to 18 Amp 240V 50 Hz AC including top complete all as specified and directed.
M/s Dhani Enterprise
KAMAKHYA CONSTRUCTION & BUILDERS
S. R. TRADING
PK ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .