Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.8 L+₹1.1 L (4.71%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹24.0 L+₹1.2 L (5.41%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹24.9 L+₹2.2 L (9.48%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹25.8 L+₹3.1 L (13.7%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹96,500
Closing Date
10 Feb 2021, 6:00 pmClosed
GE I KANPUR
GE I KANPUR CARIAPPA ROAD KANPUR CANTT 208004
SPL REPAIR REPLACEMENT OF AIR CONDITIONERS AT COD INSIDE UNDER GE I KANPUR
2021_MES_413655_1
GE(I)/KAN/T-67 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Kanpur cantt
Class D category b i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹96,500
Yes
18 Feb 2021
18 Jan 2021
12 Feb 2021
18 Jan 2021
10 Feb 2021
5 Feb 2021
Amount
Supply, installation, testing and commissioning of split air cooled split unit air conditioners 1.5 Ton capacity electric driven single phase of units indoor and outdoor complete accessories including suction and discharge pipe with insulation and cordless remote control unit and with in-built air ioniser and plasma filter for better indoor air quality with BEE 5 Star rating and EER 3.2 of capacity, using Eco friendly refrigerent gas including gas charging, installing at wall including electrical connection for power supply with suitable electrical copper cable, fixing PVC drain pipe for water drainage jointing suction & discharge line with insulation to indoor unit and all the necessary connection including grouting nut, bolt, washer and fixing of indoor unit at wall complete all as specified and directed. Make : Hitachi / DAIKIN / O General as approved by GE(I). Note : (a) The contractor shall furnish the manufactures warranty card to the Engineer in Charge. (b) The contractor shall make necessary opening on the brick / stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed and specified. (c) The refrigerant pipe (copper pipe) and power cable if additionally required at site (other than supplied with AC) will be measured and paid separately under respective items.
Supply, installation, testing and commissioning of split air cooled split unit air conditioners 2.0 Ton capacity electric driven single phase of units indoor and outdoor complete accessories including suction and discharge pipe with insulation and cordless remote control unit and with in-built air ioniser and plasma filter for better indoor air quality with BEE 4Star rating and EER 3.2 of capacity, using Eco friendly refrigerent gas including gas charging, installing at wall including electrical connection for power supply with suitable electrical copper cable, fixing PVC drain pipe for water drainage jointing suction & discharge line with insulation to indoor unit and all the necessary connection including grouting nut, bolt, washer and fixing of indoor unit at wall complete all as specified and directed. Make : Hitachi / DAIKIN / O General as approved by GE(I). Note : (a) The contractor shall furnish the manufactures warranty card to the Engineer in Charge. (b) The contractor shall make necessary opening on the brick / stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed and specified. (c) The refrigerant pipe (copper pipe) and power cable if additionally required at site (other than supplied with AC) will be measured and paid separately under respective items.
Supply and fix window type room air conditioner electric driven of capacity 2.0 TR single phase 230 Volt + 10%, 50 Hz, AC supply complete with cordless remote control unit with copper condenser air cooled with BEE 5 star rating including required cutting of holes in walls / window / aluminium partition etc of any thickness for installation of AC etc. connection and making good the disturbed surface to match with the existing complete all as specified and directed. Make : Hitachi / O General / Daikin as approved by GE(I). Note :- (i) Cutting holes in walls / window / aluminium partition etc of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Provision of angle iron stand / wall mounted platform etc for fixing / supporting the AC unit is inclusive in above rate. Note : Contractor will submit guarantee / warranty certificate from manufacturer.
Supply and fix Voltage stabilizer for automatic operation, single phase having digital display board naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. Make : V Guard / Voltas / Volina as approved by GE(I) . Note Contractor will submit guarantee/warranty certificate from manufacturer.
Supply and fix Voltage stabilizer for automatic operation, single phase having digital display board naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Make : V Guard / Voltas / Volina as approved by GE(I) . Note Contractor will submit guarantee/warranty certificate from manufacturer.
Disconnecting, dismantling and taking out indoor and outdoor unit of split AC with cooling tubing and other accessories carefully and depositing to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remote all as specified
Disconnecting, dismantling and taking out window type AC with accessories carefully and depositing to MES store yard complete with remote all as specified
M&L for fixing/installation of split type AC inner/outer both unit as received from item no 06 above with all accessories and making all connections of copper tubing/drain and including refrigerant other connectng items i.e. copper tube/drain pipe and connecting electrically and testing on completion all as specified and directed.
M&L for fixing/installation of window type AC as received from item no 07 above with all accessories and making all connections including refrigerant and testing on completion all as specified and directed.
M & L for PVC flexible pipe cut to pieces with required clamps of size 25 mm dia with suitable nipples for draining out of water complete all as specified and directed.
M & L for deoxidized annealed copper tube of 6.35 mm outer dia of 0.7 mm wall thickness or as per site reqmt including brazing etc. complete all as specified and directed.
M & L for deoxidized annealed copper tube of 15.88 mm outer dia of 0.8 mm wall thickness or as per site reqmt including brazing etc. complete all as specified and directed.
M & L for foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness or as per site reqmt complete all as specified and directed.
M & L for foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness or as per site reqmt complete all as specified and directed.
S & F of PVC rounded 3 core 4 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells / Plaza.
M/S DARSHAN ENGINEERING WORKS
Bharat Sales Corporation
Ashirwad Contractor and Supplier
U K Enterprises
DEO Traders
G S SANDHU & CO.
FATEHPUR CONSTRUCTION COMPANY
HVAC Engineering Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .