Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹45.4 L+₹4.5 L (11.1%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
Alwar
REPAIR/MAINT OF MES INSTALLATION AT ITARANA CANTT UNDER GE ALWAR
2024_MES_665142_1
8232/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE Alwar
As per NIT
3 documents required · 3 mandatory
₹500
GE Alwar
₹80,000
Yes
14 Nov 2024
10 Jul 2024
14 Sept 2024
10 Jul 2024
12 Sept 2024
26 Jul 2024
10 Jul 2024 - 25 Jul 2024
Amount
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for laying LT UG cable, Stay wire and LT pole/post holes etc and getting out in soft/loose soil etc complete all specified and directed.
Removing excavated materialn exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point etc complete all specified and directed.
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm etc complete all as specified and directed.
Supply & laying sub class B bricks, locally available un-burnt bricks suitable for LT cable protection cover etc complete all specified and directed by Engineer-in-Charge.
M&L local sand (tibba sand) for bedding ang sand cushioning of all LT UG cable etc complete all as specified and directed by Engr-in-Charge
Supply, laying and testing cable XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with stranded aluminium conductor 1100V grade , 3 1/2 core of size 70 Sqmm, rate including taking out of old UNSV cable and ACSR conducter etc all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor ,1100Volts grade of size 16 Sqmm 4 core etc complete all as specified and directed by Engineer in Charge.
M&L for preparation of metallic surface with sand papers and applying one coat of metallic primer before applying two coat of aluminium paint on steel tubular pole and cross arms any size and height etc complete all as specified and as directed by Engineer-in-Charge
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 180cm x 90cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, including PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt (6 Nos), including light point 2.5 sqmm (up to 15 m length as required)and switch independent one way 15Amp suitable for exposing at all weathers including taking down of old UNSV sign board etc complete all as specified and as directed.
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 400cm x 60cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, PCC(up to 1 cum), cement work,putti and paint excavation if required, LED tube light fittings 1x 20Watt(10 Nos), including light point 2.5sqmm (up to 15 m length as reuired ) and switch independent one way 15Amp suitable for exposing at all weathers including taking down of old UNSV sign board etc complete all as specified and as directed by Engineer-in-Charge.
S&F in repair LED street light fittings with excellent thermal management of 90 Watt IP-65 with complete accessories on MES installation bldgs at itarana cantt including taking down the old UNSV street light and connecting up the lights to the nearest point by using 1sqmm copper wire 2 run (up to 15 m) and including brackets 1.2 m and clamps 25x4 mm with nut bolts and washers , drilling holes on stone masonry etc complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc complete all as specified and as directed.
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly including making good of distrubed surface with putti plaster and paint as per existing colour etc complete all as specified and directed for the following :-
One light point controlled by one way switch.
One fan point controlled by one way switch.
One 3 pin 6 Amp socket point outlet on the same board with other switches
One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 13.00 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly including making good of distrubed surface with putti plaster and paint as per existing colour etc complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5pin, 6 Amps multi purpose flush type 230 volt etc complete all as specified and as directed
S&F in repair switch socket combination 2 in 1, 16 Amp flush type multi purpose 230 volt etc complete all as specified and as directed
S&F in repair switch piano flush button single pole one way 6 Amps 230 volt grade etc complete all as specified and as directed
S&F in repair ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board etc complete all as specified and as directed
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed
M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc including taking down old unsv point wiring.etc complete all as specified and as directed
S&F in repair distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt including taking down old unsv DB of the following Size :-
(a) 8 way SPN with200 Amp rated busbar 240 volts (double door type).
(b) 4 Way SPN with 200Amp rated busbar 240V (Double door type)
S&F in repair MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating:-
(a) MCB SP 240 volts 6 to 32 Amps
(b) MCB SPN 240 volts, 32 Amps
S&F in repair decorative ultra slim,elegant and sleek designed LED T5 batten lighting fixture with extruded aluminium housing with frosted diffuser envirenmentel friendly energy efficient sutiable for 20 watt LED tube light with 125 lumen per watt etc complete all as specified and directed .
M&L batten/angle holder insulated with back plate including suitable size of PVC round block etc complete all as specified and as directed.
Material and labour for renewal of Earthing complete with GI earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included GI earth strip 32mmx 6mm by means of bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg, crystal salt 200 kg ,magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil PCC 1:3:6 type C1 for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type B1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric or XPM jalli (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh etc complete all as specied and directed. Note:- Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
S&F in repair GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation etc complete all as specified and as directed by Engineer-in-Charge.
M&L for Cutting anxious green growth / vegetation growth from root for cleaning out the area around OH tank / pump house, electric sub station at ground level by cutting up root, un- wanted plants / bushes and removal the same to a distance not less than 50 mtr including levelling of land through JCB directed by engineer -in -charge , Note: (i) Rate including Cutting T&P, transporting/disposal/ dumping away from the site as per the laid down procedure of waste management system shall be considered with this item rate. (ii) Entire site shall not be given for one time. Area for cleaning shall be given to the contractor on requirement basis as per the site conditions and growth rate of bushes and grass etc. The area shall be divided into several parts and shall be directed to the contractor when cleaning is required at site. (iii) The above job is carried out in beginning from acceptance of contract and other after 3 month .
S&F in repair load change over switch 415 volt in sheet metel enclouser 4 pole of capacity 160 amp etc complete all as specified and directed by engineer -in-charge
S&F in repair load change over switch 415 volt in sheet metel enclouser 4 pole of capacity 200 amp etc complete all as specified and directed by engineer -in-charge
S&F in repair of sluice valves of cast iron body with forged brass spindle, class PN 1.6 and cast iron wheel head, both ends flanged, IS-1486 marked complete with neoprene rubber gasket joints, nuts, bolts (high tensile), and washers etc complete all as specified and directed of following size:-
(a) 150mm bore flanged end.
(b) 100mm bore flanged end.
S&F in repair of non return valve, flanged ends PN 1.0 ISI marked of 100mm bore etc complete all as specified and as directed
S&F in repaiir of non return valve, flanged ends PN 1.0 ISI marked of 80mm bore etc complete all as specified and as directed
Supply and fix in repair of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing,of the following sizes :- Note :-Excavation earth work will be measured and paid saperatly.
(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 80mm bore
S&F in repair MCCB for LT panels/ Feeder piller of following capacity and replace with new MCCBs without damaging the LT panel board or any assets associated with the installation for following sizes:-
(a) MCCB 4 pole TPN, 160Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
(b) MCCB 4 pole TPN, 200Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
(c) MCCB 4 pole TPN, 400 Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
(d) MCCB 3 pole TP, 63 to 100 Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
S&F rubber mat of 1 meter x 2 meter x 2.5 mm etc complete all as specified and directed by engineer-in-charge
Supply and fix electric rubber hand gloves (two glooves for each person) suitable for 11KV etc complete all as specified and directed
S&F in repair connection and test submersible cables copper conductor PVC insulated over all sheathed flat flexible, ISI marked - Conforming to IS 694,1100 volts grade etc complete all as specified and directed of sizes:-
(a) 10 sqmm 3 core
(b) 6 sqmm 3 core
S&F in repair of ^lithium based Energy Efficient Integrated solar street light of 40 watt ^ in single FRP body with duly polyurethane coating(camouflage colour),encases with monocrystalline solar PV panel of 65-67 Wp ,lithium battery 11.1/12.8 v 33 AH with inbuilt BMS IP 65 high brightness W-LED (160/180 lm /watt) lamp with aluminium reflector for better light distrubtion CRI>70 colour temperature 5700-6500K . microcontroller basedcharge controller cum driver automatic diming function (frist four hour at full brightness and rest of the time at lower light level with PIR motion sensor dusk to dawn operation sutiable to working temperature -10 to 55 C .weight not more than 14-16 kg with adjustiable MS clamp sutiable for pole wall mounting etc complete as requirer protection-short circuit overload reverse polarity and battery protection firm should provide vital parameter test report from NABL accredited lab etc complete all as specified and directed
S&F in repair Direct Online Starter of capacity 7.5HP suitable for monoblock pumpsets installed at pump house ,borewell or any E/M installation etc complete all as specified and as directed by Engineer-in-Charge. Make:- L&T, Cat Part No SS96211 or equivalent make as mentioned in Appndix 'D'
S&F in replair Direct Online Starter of capacity 15 HP suitable for monoblock pumpsets installed at pump house ,borewell or any E/M installation etc complete all as specified and as directed by Engineer-in-Charge. Make:- L&T, Cat Part No SS96212 or equivalent make as mentioned in Appndix 'D'
S&F in repair fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for up to 40 HP and above 70 amp submersible motor pump including first filling of oil in oil chamber (If Required) and testing etc complete all as specified and directed. Make : L&T, Cat Part No CS90908 or equivalent make as mentioned in Appndix 'D'
supply installation testing and commissioning of submersible pump set of 15 HP Capicity ,coupled with submersible motor with sutiable delivery , head more than 60mtr discharge 1500LPM including mounting accessories ,GI clamp ,channels ,rubber gasket hanging rope made up of SWR or nylon water proof rope of sutiable dia etc and fabrication if any at bore well etc complete all as specified and directed by Engineer-in-Charge. Note:- Contractor shall test run the pump set by deputing sutiable tecnician from OEM in front of Engineer-in-Charge till achiving satisfactory result.
M&L for Glow sign board of size 150cm x 90cm x 15cm, out door type, totally enclosed with locking arrangement, made of 1.75mm thick both side poly carbonate milky white sheet with letters/matter by overlay colour film (colour as approved by GE) pasted over sheet, frame work made out of 26 gauge thick galvanized iron sheet and 50mm x 50mm x 5mm MS angle iron, including LED tube light fittings 1x18 watt - 6 Nos, prewired, with & including all standard accessories including making electric connections with suitable size mutistranded copper wire, including two coats of synthetic enamel painting over a coat of zinc chrome primer after preparation of steel surfaces, fixed at site by grouting the legs of frame in PCC (1:2:4 type B1) block of size 40cm x 40cm x 45cm, including dismantling & taking out old sign board, etc complete all as specified and as directed Note : Top of sign board shall be 2 metre from ground level. Legs shall be embedded in PCC block upto 40cm depth. 20cm long holdfast made of MS angle iron of size 40 mm x 40 mm x 6mm shall be welded at bottom of each leg. Letters/matter etc for sign board shall be given by the Engineer-in-charge as per location of sign board.
M&L for construction of brick masonry valve pit all as specified and as shown on drawing no. TD/2004/26 Sheet No 1/3 to 3/3 including excavation and earth work in any type of soil, PCC in foundation, coping, plastering,fabrication of valve pit chamber cover made out of angle iron frame and MS plates of thickness 3 mm with locking arrangement, 50mm dia lock with 03 keys, including of openable arrangement by heavy duty MS Hings of suitable size painted with synthetic enamelled paint (Blue colour) over a coat of primer including grouting of frame in PCC or brick work with plaster and final touch with double layer of white wash complete including all necessary excavation work and cutting of pipe including . jointing of valve including taking down old unsv valve pit MS cover etc complete all as specified and directed. of following sizes:-
(a) 1000mmx 950mm x 1000mm
(b) 1200 mmx 1200mmx 1000mm
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type and including bracket of 40mm dia and clamp of 40x 6mm complete and including pipe 40mm light grade of 1.5mtr lenth all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of BOQ.
M&L for PCC (1:3:6) type C1 using 40mm grade stone aggregate in foundation and mass concrete including necessary form work etc complete all as specified and directed by Engg in charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles etc including necessary form work, finished the exposed surfaces fair and even without using extra cement etc complete all as specified and directed by Engg in charge.
S&F street light GI bracket of 1.5 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole and including dismantling old U/S GI bracket of any size & length.etc as specified and as directed.
Supply, installation, testing and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 280 x 170 x 105 mm depth with cable entry size of 10Sqmm to 25 sqmm with 4 No. busbar of capacity 63 Amps and MCB SP 6 Amp-1 No, with flat iron clamps of size 30 x 6mm, nuts and bolts complete including taking down old etc complete all as specified and directed by Engg in charge.
M&L for rewinding fan motor of capacity 1/10 HP or 1/8 HP or 180 watt for desert cooler single phase AC 50 Hz with super enamelled copper wire of existing gauge/ size of etc complete all as specified and directed.
S&F in repairs wool pad set (set of 3) including wire mesh suitable for 18"/20" desert cooleretc complete all as specified and directed.
S&F in repairs Desert Cooler fan motor suitable for 18"/20" inches desert cooler complete of etc complete all as specified and directed.
S&F in repairs Desert Cooler spray pump suitable for 18"/20" inches desert cooler etc complete all as specified and directed.
S&F in repairs 3 core flexible cable of copper conductor 23/0.0076 etc complete all as specified and directed.
S&F in repairs regulating switch three speed 5 Amps, SP, 230 volts etc complete all as specified and directed
S&F in repairs PVC flexible pipe 15mm bore of superior quality.etc complete all as specified and directed
S&F in repairs PVC water distributor 3 way assembly of size 15mm including fixing at top of cooler by means of screw/bolts/nuts etc complete all as specified and directed.
M&L for preparation of steel surfaces including replacement of tank of desired capacity of desert cooler & applying two coats of synthetic enamel paint first quality over a coat of red oxide primer etc complete all as specified and directed.
S&F LED type security-DRACO SERIES light luminaire 25 watts, 230 Volts 50 Hz including all necessary fitting accessories and LED etc complete all as specified and directed.
Supply ,installation and testing and commissioning 15 HP submerssible motor with copper winding etc complete as specified and complete set etc complete all as specified and directed. Note: Contractor shall test run motor by deputing sutiable from OEM in front of engineer-in-charge till achiving satisfactory result and old motor shall be deposited in MES store yards
Shiv Enterprises (BID ID -3082349)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .