Loading…
Loading…
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
10 Feb 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
TOWNSHIP
12 conditions · 1 needing a document upload
Electrical Contractor License: Tenderer(s) have to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with the tender documents, failing which the offer is liable to be rejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Re-wiring of KV-1 School in Rail Coach Factory Kapurthala.
RCF-EL-TS-ET-121B-2024-25~RCF
RCF-EL-TS-ET-121B-2024-25
Open
Works - General
3 Months
Kapurthala, Punjab
₹0
₹19,800
10 Feb 2026
13 Jan 2026
27 Jan 2026
37 items across 1 schedule · ₹9,91,188.3 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Light Point Wiring:- Supply, wiring, testing & commissioning of light /ceiling fan/exhuast fan/brakcet light points with 2x1.5 sq mm cu wire and, 1.5 sq mm as earth wire along with modular Switch and modular plates etc, after removing the old aluminium wires, tubelight, ceiling fan, bracket light switch plates etc. as per item no. 01 0f explanatory notes. | Numbers | 540.00 | 502.14 | 2,71,155.6 |
| 2 | 6 Amp. Plug point:- Supply, wiring, testing & commissioning of 6 Amp. Plug point wth 1.5 sq mm cu wire as phase, neutral and 1.5 sq mm as earth wire along with modular Switch, modular socket and modular plate etc. after removing the old aluminium wires , switch /socket plates etc. as per item no. 02 0f explanatory notes. | Numbers | 265.00 | 580.44 | 1,53,816.6 |
| 3 | 16 Amp. Plug point:- Supply, wiring, testing & commissioning of 16 Amp. Plug point wth 2x4 sq mm cu wire and 2.5 sq mm as earth wire along with modular Switch, modular socket and modular plate etc. after removing the old aluminium wires, switch /socket plates etc. as per item no. 03 0f explanatory notes. | Numbers | 150.00 | 625.43 | 93,814.5 |
| 4 | Two-way switch point:- Supply, wiring, testing & commissioning of twin control light points with 1.5 sq mm Cu phase, neutral wire & 1.5 sq mm as earth wire along with modular 02 way Switch and modular plate etc. after removing the old aluminium wires , switch plates etc. as per item no. 04 0f explanatory notes. | Numbers | 8.00 | 372.56 | 2,980.48 |
| 5 | Supply, wiring, testing & commissioning 2 x 4 sq mm copper wire along with 4.0 sq m green colour multistrand earth wire from TPN/DB to AC point after removing the old wires etc as per item no. 05 0f explanatory notes. | RM | 400.00 | 93 | 37,200 |
| 6 | Supply, wiring, testing & commissioning 2 x 6 sq mm copper wire along with 4.0 sq m green colour multistrand earth wire from Meter to TPN/DB after removing the old wires etc as per item no. 06 0f explanatory notes. | RM | 200.00 | 102.59 | 20,518 |
| 7 | Ceiling fan fixing: Fixing, testing and commissioning of 1400 mm sweep ceiling fan (Existing Ceiling FAN will be provided after rewiring.) as per item no. 07 0f explanatory notes. | Numbers | 150.00 | 47.5 | 7,125 |
| 8 | Fan Regulator:- Supply, fixing, testing and commissioning of step type electronic modular fan regulator 100 watt as per specifications as per item no. 08 of explanatory notes. | Numbers | 150.00 | 172.78 | 25,917 |
| 9 | Fixing testing and commissioning of metal body exhaust fan 300mm/450 mm dia sweep 1400 RPM in kitchen. as per item no. 09 of explanatory notes. | Numbers | 30.00 | 58.74 | 1,762.2 |
| 10 | Batton Holder:- Supply, fixing, testing and commissioning of batten holders without bulb in lieu of bracket light points as per item no. 10 of explanatory notes. | Numbers | 30.00 | 38.7 | 1,161 |
| 11 | Distribution Board:- Supply, fixing (Flush type), testing and commissioning of 12way TPN/DB along with RCCB, MCB's (10A - 12 Nos; 16A - 12 Nos; 20A - 12 Nos; ELCB and TPN MCB-63A). Indoasian Make cat. ref or equivalent as per list of makes. 1. TPN/DB(12 way), Cat Ref: 811861 (8+36 modules) 2. TPN, 63 A, Cat no: 811220 3. MCB (10A, 16A,25A)36 Nos. 4. RCCB, 4 Pole, 63 A, Cat Ref: 811732 As per specifications after removing the old distribution boxes as per item no. 11 of explanatory notes. | Numbers | 4.00 | 32,591 | 1,30,364 |
| 12 | Distribution Board:- Supply, fixing (Flush type), testing and commissioning of 08 way TPN/DB along with RCCB, MCB's (10A - 12 Nos; 16A - 06 Nos; 20A - 06 Nos; ELCB and TPN MCB-63A) as per specifications after removing the old distribution boxes as per item no. 12 of explanatory notes. | Numbers | 2.00 | 12,794.6 | 25,589.2 |
| 13 | Supply, fixing of metallic concealed switch boxes in the wall of size 3"x3"/3"x4" after removing the old damaged boxes as per item no. 13 of explanatory notes. | Numbers | 20.00 | 23.4 | 468 |
| 14 | Supply, fixing of metallic concealed switch boxes in the wall of size 4"x6"/3"X8" after removing the old damaged boxes as per item no. 14 of explanatory notes. | Numbers | 40.00 | 116.09 | 4,643.6 |
| 15 | Supply, fixing of metallic concealed switch boxes in the wall of size 3"x5" after removing the old damaged boxes as per item no. 15 of explanatory notes. | Numbers | 20.00 | 66.59 | 1,331.8 |
| 16 | supply, fixing of metallic concealed switch boxes in the wall of size 5"x5" after removing the old damaged boxes as per item no. 16 of explanatory notes. | Numbers | 20.00 | 116.09 | 2,321.8 |
| 17 | Supply, fixing and Replacing/Providing of the GI Switch boxes of size 8"x10" modular type only at Existing locations of Quarters and service buildings with Hylam sheet top cover ISI marked (thickness 3mm) by making cutting in the Cemented wall and repairing the wall as it is original as per item no. 17 of explanatory notes. | Numbers | 20.00 | 196.84 | 3,936.8 |
| 18 | Supply, fixing of metallic concealed switch boxes in the wall of size 10 inch X 12 inch (19 Modules) after removing the old damaged boxes as per item no. 18 of explanatory notes. | Numbers | 30.00 | 252.81 | 7,584.3 |
| 19 | Supply, fixing of PVC Conduit pipe MMS (Medium mechanical strength) of 25 mm dia by making slit in the cemented wall, repairing the wall as it is original as per item no. 19 of explanatory notes. | RM | 500.00 | 33.3 | 16,650 |
| 20 | Supply, fixing, testing and commissioning of AC supply box (2 way SPN/DB) along with the 25 Amp SPN MCB for controlling AC unit Supply as per item no. 20 of explanatory notes. | Numbers | 10.00 | 719.92 | 7,199.2 |
| 21 | Call bell: Supplying & fixing of modular type Bell push switch on the existing modular plate & Switch box including connections with Modular Switch plate etc. as required as per item no. 21 of explanatory notes. | Numbers | 10.00 | 98.42 | 984.2 |
| 22 | LED Bulk Head: Fixing, Testing and commissioning of LED bulk head fitting of 10 watt as per explanatory notes. as per item no. 22 of explanatory notes. | Numbers | 20.00 | 36.9 | 738 |
| 23 | LED 18 W Tubelight: Fixing, Testing and commissioning of LED Tubelight fitting of 18 watt as per explanatory notes. (Tubelights will be procured & supplied through RCF/Elect/Store/Township). as per item no. 23 of explanatory notes. | Numbers | 300.00 | 38.7 | 11,610 |
| 24 | Supply, Fixing (flush type) testing and commissioning of TPN loop in loop out box made of SS-304 Stainless steel of size 350x250x100 mm of 1.6mm thick sheet along with 200A terminals mounted on DMC base with separator, duly powder coated with paint shade siemens RAL7032 of M/s Burger/Nerolac/Asian.The door box shall have hinges of SS-304 with proper stopper arrangement as per specifications and explanatory notes. The drg.& sample to be got approved from the deptt. before supplying. as per item no. 24 of explanatory notes. | Numbers | 6.00 | 2,952.6 | 17,715.6 |
| 25 | Supply, fixing, testing and commissioning of Small size Junction boxes (for approx. 3.0mtr/5.0mtr/5.5 mtr long poles) of stainless steel SS-304 sheet 1.6 mm thick duly powder coated complete with SS-304 clamps of 3mm thickness, 2mm thicksheet hinges of stainless steel only on the streetlight pole as per RCFdesign. Note:- Earth connection should be properly connected to Jn.box with use of copper thimble & connection to armoured wires as per item no. 25 of explanatory notes. | Numbers | 10.00 | 1,968.4 | 19,684 |
| 26 | Pipe Earthing: Supply, providing, testing and commissioning of GI Pipe earth stations as per Fig.14 of IS:3043-1987 as per item no. 26 of explanatory notes. | Numbers | 10.00 | 2,007 | 20,070 |
| 27 | Earth GI Strip wire: Supply & providing earth connections with 3 x 25 mm GI strip from earth stations to electrical panels as per item no. 27 of explanatory notes. | RM | 100.00 | 98.42 | 9,842 |
| 28 | Digging of pucca/concrete soil with the help of bockie for crossing the roads/pathways/pucca surface areas etc. The hole of bockie shall be 1000 mmbelow the top surface of the road and providing and laying the HDPE hume pipe of required size to run through the power supply cables. (The supply of HDPE pipe is under the scope of the tenderer) as per item no. 28 of explanatory notes. | RM | 60.00 | 295.26 | 17,715.6 |
| 29 | Excavation of trench in pucca area 1 mtr deep and 400mm wide with 75mm sand layer around the cable and top covered with class -B bricks for protection and repair the site to same as itis original shape. (The supply of bricks, sand, Cement etc are under the scope of the tenderer) as per item no. 29 of explanatory notes. | RM | 40.00 | 295.26 | 11,810.4 |
| 30 | Excavation of trench under Soft soil minimum 1 meter deep & 400 mm wide for laying of XLPE al. armoured cables of all sizes as per site requirement and provide sand cushoning of 75mm thick layer around the cable and top protection with class B bricks, laterally to cable length of cable as per RCFdrawing ( The sand, bricks etc are in the scope of the tenderer). The trench to refilled back after laying of cable, ramming, levelling and watering the excavated area after laying of cable to bring the surface to original level as per item no. 30 of explanatory notes. | RM | 230.00 | 127.95 | 29,428.5 |
| 31 | Laying of 4x70/4x50 sq mm XLPE cable in the existing excavated trench/Hume pipe/GIPipe/HDPE pipe as per site requirement. (cables will be supplied by RCF) as per item no. 31 of explanatory notes. | RM | 200.00 | 14.76 | 2,952 |
| 32 | Laying of 4x25/4x16 sqmm XLPE cable in theexisting excavated trench/through Hume pipe/GIPipe/HDPE pipe as per siterequirement. as per item no. 32 of explanatory notes. | RM | 200.00 | 13.78 | 2,756 |
| 33 | Supply, fixing, testing and commissioning of End terminations (only thimbles) & heat shrinkable sleeves of existing cables of size 4x50 sq. mm /4x70 sq.mm XLPE cables to be provided aluminium reducer terminals(Thimbles/lugs) to be crimped properly and fixing in the brass terminals of junction boxes as per item no. 33 of explanatory notes. | Set | 6.00 | 98.42 | 590.52 |
| 34 | Supply, fixing, testing and commissioning of End terminations (only thimbles) & heat shrinkable sleeves of existing cables of size 4x25 sq. mm /4x16 sq.mm XLPE cables to be provided aluminium reducer terminals(Thimbles/lugs) to be crimped properly and fixing in the brass terminals of junction boxes as per item no. 34 of explanatory notes. | Set | 10.00 | 98.42 | 984.2 |
| 35 | Bulk Head Fiiting: Supply of Bulk Head fitting with 9- 11 WATT lamp, IP 43 with cast aluminium body, as per PO H2050461 Dt:16/03/2020. as per item no. 35 of explanatory notes. | Numbers | 20.00 | 315.65 | 6,313 |
| 36 | LED 45 W Streetlight: SITC of street light fitting 45 watt LED, on 40 mm dia GI pipe having length 03 m on the walll with 1200 bend at the centre. as per item no. 36 of explanatory notes. | Numbers | 10.00 | 947.52 | 9,475.2 |
| 37 | Supply of XLPE cable of size 4Cx 16 Sq mm confirming to IS:7098(part-I) with latest amendments. as per item no. 37 of explanatory notes. | RM | 200.00 | 64.9 | 12,980 |
| Schedule total | ₹9,91,188.3 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .