Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹22.2 L+₹2,480 (0.11%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹23.1 L+₹94,740 (4.27%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹29.9 L+₹7.7 L (34.9%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹31.1 L+₹9.0 L (40.4%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
19 Mar 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR REPLACEMENT OF SUB MAIN WIRING BLDG METER BOX PANEL BLDG DB GATE LIGHT GARDEN LIGHTS AND ITS CONNECTED ITEMS INCLUDING CERTAIN MISC E/M PORTION AT AUNDH MIL STN UNDER GE MH AND RH KHADKI
2024_MES_643707_1
8545/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹70,000
16 May 2024
22 Feb 2024
21 Mar 2024
22 Feb 2024
19 Mar 2024
7 Mar 2024
22 Feb 2024 - 12 Mar 2024
Amount
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 2.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continuous earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two single core cable, earth wire and PVC conduit shall be measured as one length.
All as per item No 01 above but of 4 Sqmm Make : Polycab /Finolex/ RR
All as per item No 01 above but of 6 Sqmm Make : Polycab /Finolex/ RR
All as per item No 01 above but of 10 Sqmm Make : Polycab /Finolex/ RR
S & F sheet metal enclosures in repair double door distribution board factory made duly painted of following capacity with 200 amps rated copper bus bar , suitable for fixing MCB /Isolators all as specified Make:L & T/Legrand/Havells or equivalent make
12 way SPN, 240V
8 way SPN 240V
8 way TPN, 415V
12 way TPN, 415V
S & F MCCB 125 Amps, 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity. Make : L &T /Legrand/standard.
Supply and fixing miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB Complete with connection testing and commissioning. Make : L &T /Legrand/Havells
SP 5 to 32 AMP, 240V, 10 KA 'B' curve
SP 40 AMP, 240V, 10 KA 'B' curve
SPN 32 Amps, 240V, 10 KA 'B' curve
SPN 40 Amps, 240V, 10 KA 'B' curve
TPN 63Amps, 240V, 10 KA 'B' curve
Supply and replace hylum sheet 3 mm thick for Junction boxes, circuit boxes for various size and refixing the existing switches, sockets, regulators cut in to required sizes including fixing with new cadmium plated screws and cup washers complete all as specified and as directed.
M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
100 x 100 mm and 50 mm deep
200 x 150 x 50 mm deep
250 x 200 x 50 mm deep
Decarbonizing of indoor MCB / meter box any type removing unserviceable MCCBs, burnt bus bars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter, replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of broken MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB & MCBs, powder coating painting with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks including dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge. Note : (i) MCCBs, indicator lamps, Ammeter, Volt meter, will be measured & paid separately as supply only. (ii) necessary MS sheet and welding including sealing the meter with sealing lead/PVC seal with MES Emblum embossing on it all are inclusive coated rate. (iii) Required size of neutral bus bars including coated rate. (iv) Required size of copper cable for connecting MCBs and meters are including quoted rate.
S & F in repair meter panel box indoor type wall mounting of with locking arrangement including powder coating siemens grey shade for size 1200 (w) x 900 (h) x 250 (d) mm, with the provision of MCB mounting channels suitable for mounting 10 Nos single phase meter complete all as specified and directed by Engr-in-Charge.
S & F in repair meter panel box indoor type wall mounting of with locking arrangement including powder coating siemens grey shade for size 900 (w) x 900 (h) x 250 (d) mm, with the provision of MCB mounting channels suitable for mounting 07 Nos single phase meter complete all as specified and directed by Engr-in-Charge.
S & F in repair meter panel box indoor type wall mounting of with locking arrangement including powder coating siemens grey shade for size 600 (w) x 500 (h) x 250 (d) mm, with the provision of MCB mounting channels suitable for mounting 01 Nos three phase meter complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing or passing through pipe or laid in trenches or fixed to pole/wall or fixed to LT panel board, insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 4 sqmm 2 core incl suitable end terminations with cable glands, aluminium lugs, sleeves as required includung taking down unserviceable cable complete all as specified and directed by Engr-in-charge.
Excavation in trenches for taking out/laying of cable and pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide complete and all as specified for the following type of soil:-
Soft and loose soil
Hard dense soil
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose/hard/dense soil complete all as specified.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified.
M & L for riddled earth for cushioning including spreading, levelling and hand punning to under ground cable in trench all as specified and directed. Note: Punned thickness shall only be measured and paid seperately.
M&L for brick Class 'B' size 230 mm x 115 mm x 75 mm protection for under ground cable all as specified and directed.
Taking down the old bricks during excavation and relaying the same serviceable brick / PCC covers for protection of UG cable all as specified and directed.
Supply and fixing MCB, single pole, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 2 AMP, in the FRP Box complete with connection testing and commissioning including taking down unserviceable pole box complete all as directed by Engr-in-charge.
Taking down old unsv bollard light and M & L for LED based bollard light, with aluminium housing with acrylic diffuser of cap 10 W with IP 65/66 protection, bollard length should be 800mm with all accessories complete all as specified and directed. Make : Jaquar Cat part No :JSB-GRY-LBLDCON10XW or equivalent Halonex/ Crompton Note : The quoted rates is inclusive of excavation and foundation work of PCC of bollard fittings as recommended by OEM and Engr-in Charge.
Taking down old unserviceable post top lantern (gate light) 12 W with high power brightness LM 80 certified LED, made up of die cast aluminium spigot, spun aluminium powder coated top cover, aluminium PDC heat shrink, opal PC diffuser and clear acrylic diffuser with IP 65 protection and connecting with three core flexible copper wire from connector to ceiling rose. Make : Jaquar/ Halonix/Havells.
Taking down old unserviceable straight translucent poles size 0.75Mtr, Top and Bottom size 90 mm dia and light system 20-30 Watts, pole is wound on multi axis CNC filament winding machines using low angles for high strength, pole colour as per site required complete all as specified and directed. Make :Helipole or equivalent make Note: The price inclusive of Flange, Dome cover for bolts, cutout, cover for cutout with SS bolts
SKS Electricals
PURVA ELECTRICALS AND ENGINEERS
Adinath Technical Services
ANUSHKA BUILDERS
SHREE VAIBHAV ELECTRICALS
Mahindra Electric Stores
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .