Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.7 L+₹1.3 L (3.86%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.0 L+₹3.5 L (10.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹36.0 L+₹3.5 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹38.4 L+₹5.9 L (18.3%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L5 | Rejected-Finance Being L5 |
Tender Value
₹41.1 L
EMD Value
₹82,300
Closing Date
19 Sept 2024, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow -453441
PROVISION OF STORE ROOM SENTRY POST AND PARKING SHED AT HEMMA FF RANGE AT INF SCHOOL UNDER GE MIS MHOW
2024_MES_667070_1
8705/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
150 days
GARRISON ENGINEER (MIS)
All as per Tender document
7 documents required · 7 mandatory
₹500
GE (MIS) Mhow
₹82,300
Yes
23 Oct 2024
20 Jul 2024
23 Sept 2024
20 Jul 2024
19 Sept 2024
3 Aug 2024
Amount
Surface dressing not exceeding 15 cm deep in soft/loose soil all as specified .
Excavation over areas not exceeding 1.5 m deep and getting out in any type of soil complete all as specified
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for shafts, wells, cespits, manholes, pier hold etc not exceeding 10 Sqm on plan and getting out in any type of soil complete all as specified
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified.
Returing, filling in trenches with soil including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm in hard/dense soil complete all as specified
M&L for moorum / red bajri filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including waterring and consolidation complete all as specified.Note:consolidated thickness shall be measured.
M&L for hardcore with broken stone of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified
M&L for plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filing,sub base of floor etc complete all as specified
M&L for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filing,sub base of floor etc complete all as specified
M&L for reinforced design mix cement concrete of grade M25 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified NOTE : Reinforcement shall be measured and paid separately under relevant item.
M&L for reinforced design mix cement concrete of grade M25 using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in Chhajjas and the like, etc complete all as specified NOTE : Reinforcement shall be measured and paid separately under relevant item.
M&L for reinforced cement concrete of grade M25 using 20 mm graded stone aggregate as in beams, bands, cantilvers, bressummers, lintel etc complete all as specified. NOTE : Reinforcement shall be measured and paid separately under relevant item.
M&L for reinforced cement concrete of grade M25 using 20 mm graded stone aggregate as in chajjas complete all as specified. NOTE : Reinforcement shall be measured and paid separately under relevant item.
M&L for reinforced design mix cement concrete of grade M-25 using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified . NOTE : Reinforcement shall be measured and paid separately under relevant item.
M&L for high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, etc complete all as specified
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups ,spaces,nibs and binders including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, etc complete all as specified
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits of foundation and plinth beams and similar work , vertical or to batter fair finished surface of concrete complete all as specified
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions,fair finished surface of concrete complete all as specified
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) etc for rough finished surface of concrete surface complete all as specified
M&L for use and waste of formwork to sides and soffits of floor or roof beam, beam hauchings, bands, girders, bressummers, lintels, etc for fair finish surfacecs complete all as specified and directed
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6.00m mean radius built in cement mortor 1:4 complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified
M&L for rendering 5mm thick in cement mortar 1:3 on ceiling concrete surface, finished even and smooth without using extra cement complete all as specified
M&L for machine cut Kota stone slab flooring 20 mm thick (+ 2mm) thick of size 58cm x 58cm (or nearest size as available in the market) laid over and including 25 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate and 15mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing to mirror finish, complete all as specified and directed
S&F Mild steel, plain, black sheet 2.0 mm thickness in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, but in hearths; covering to door shutters; covering to door chowkats (frames);chullah hoods; water tanks; water troughs;ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched;including round headed screws, clout nails or rivets and fixed to wood or steel members, etc.,with plain 40 mm lap joints or welded/ riveted seams including bending, turning up,mitred angles, stopped ends, outlets etc complete all as specified and directed.
S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc. complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-250) quality-A complete all as specified
S&F Steel rolling shutter without ball bearing all as specified including top cover anchoring rod , hasp and staple and one shop coat primer erected in postion as indicated gear operated type with bevel gear box and crank handle complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection ,finished the surfaces of concrete topping even and fair without using extra cement including making joint at every 3 meter interval and at corner and filled with a mixture of bitumen and sand laid in alternate bays complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall , pillasters, cornices etc (upto G+3 storied building) by scrapping down , brooming down or steel wire brushing, and washing with water and applying two coats of superior quality exterior weather proof water base emulsion paint over a coat of primer of same make on wall complete all as specified and directed. Note :- (a) Each stage i.e preparation of surfaces,application of primer, application of first coat, application of second coat shall be got passed by Engineer-in-Charge (b) Written Warranty for four years or as per manufacturer's instructions, whichever more shall be furnished by the contractor (c) Putty shall be measured and paid separately under relevant item.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistance primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash on ceiling surface complete all as specified and directed.
S&F Steel ventilator with top hung shutter including projecting type hinges with steel handle, steel peg stay, complete with glazing bar, dovetailed or welded complete all as specified and as directed
S&F Mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M&L for providing and applying minimum 1mm thick wall care putty over the prepared surface to make the surface even and smooth for painting.
M&L for preparing roof surface of any description and applying bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm all as specified .
M & L for applying two coats of tack coat of Industrial bitumen of grade 85/25 at the rate of 1.2 Kg per Sqm including cleaning the surface all as specified .Note: 1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat shall be measured and paid seperately.
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyster non wove fabric ( weight not less than 150 gms/sqm) laid on primed surface by forced torch application complete all as specified and as per Manufacturer's instructions.
M&L for applying two coats of bitumen based aluminium painting @ 0.15 Kg/Sqm for each coat over APP membrane including preparation of surface complete all as specified and directed
S&F Mild steel work as in tubular trusses / tubular pipes as in post including special shaped washer etc complete using ERW or induction butt welded tubes. confirming to IS-11611979 grade St.-240 complete all as specified and directed
M & L for preparing steel surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer
S&F Pre-painted Galvalume/ Zinkalume corrugated sheeting 0.50 mm thickness as in roof, etc, having crest depth 28-30mm at a pitch of 195-250 mm and having 2 ribs in between for addition strength fixed with zink coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap complete as directed and specified.
M&L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC FRLS concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches and blank plates, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
One ligh/Exhaust Fan point controlled by one switch
One 5amps socket out let point controlled by one switch on the same board with other switches.
One 5amps socket out let point on independent board controlled by one switch.
All as per item No 44 here in before but using FRLS PVC insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FRLS PVC insulated cable for 15 amps socket point on independent board controlled by one switch.
M&L for Point wiring with FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core two run having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit not less than 25mm base size with all fitting and fixing accessories and with 1.5 Sqmm green FRLS PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs including galvanised/wooden boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for the followings.
One light/ fan/ bell point controlled by one switch
S&F Modular Switch flush type 6 Amps single pole, one way
S&F Modular Socket outlet, multi purpose, 2/3 Pin combined 6 Amps flush type
S&F Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socket complete
S&F Modular Switch 16 Amps single pole, one way
S&F modular fan regulator step type, 2 module type
S&F ceiling rose surface bakelite three terminal
S&F integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 , Bajaj cat Pt No. BCLSB 18WH or equivalent in Wipro
Supply and fix LED street light fittings 1x35 Watt, 5700K complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 /66protection fixed on and including sufficient length and appropriate size GI bracket with all accessories duly connection with three core flexible copper cable complete all as specified and directed .Make:- Havells Cat No.LHEXAYP7PN6K030 Crompton Cat No. LSTO-25-CDL, Bajaj Cat No. BCLST 25W LED IV2
M&L for sub main wiring with 02 runs of 6 sqmm main wire along with 01 run of 06 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. Make of cable - Havells / Finolex / RR Kabel Ltd. / L&T Make of PVC Conduit( FRLS) - Presto Plast / Finolex / Jindal / Asian / AKG
S&F sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system, IP 43, IK 09 protection including necessary provision for inserting the DBs, fixed in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with the existing colour of wall complete all as specified and as directed.
S&F double door SPN DBs 08 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed
S&F MCB TPN 40 to 100 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified
S&F MCB SPN 6 to 32 amps 10 KA, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified
S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified
S&F Exhaust fan , steel body AC single phase, 230 V of size 300 mm sweep ventil air DSP green type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall or fixing in aluminium fabricated windows including provision of PVC flexible copper cable of size 23/0.0076 three core from ceiling rose to exhaust fan for connection including making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
S&F BLDC ceiling fans with blade and remote e including down rods (as per site requirement),and accessories, 230 V, 1400 mm sweep,minimum air delivery 210 CFM with service value 6.00 BEE.,five star rated with brushless direct current motor (BLDC) complete all as specified
M & L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion including taking down/dismantling the existing complete all as specified and directed.
S&F LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches / ducts, on poles of size 4 core x 16 Sqmm including testing commissioning complete all as specified
M & L for clean and dry sand (un-washed) in trenches including spreading and leveling for cushioning of UG cable complete all specified and directed.
M&L for bricks slightly over burnt (kiln burnt) , modular bricks , best quality, locally available , laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified and as directed.
Supply, laying and jointing GI pipe 'light grade' 40 mm bore in trenches/under floors or roads/ along poles/ on wall including clamps for protection of cables complete all as specified and directed.
m/s ajay chandil (BID ID -3100681)
APconstruction (BID ID -3100711)
M/s Narendra kumar Agrawal (BID ID -3094697)
sunway associates (BID ID -3093189)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .