Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted | |
| 2 | L2₹12.5 L+₹2.1 L (19.7%)Rejected-AOC 11 71 KAVERI PATH MANSAROVAR JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L2 | Rejected-AOC Rejected being higher quoted | |
| 3 | L3₹14.6 L+₹4.2 L (39.8%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoted |
Tender Value
₹18.3 L
EMD Value
₹36,500
Closing Date
16 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-53/2020-21
2020_MES_404846_1
GE(H)-53/2020-21
Open Tender
Civil Works
Item Rate
240 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹36,500
Yes
22 Jan 2021
18 Dec 2020
18 Jan 2021
18 Dec 2020
16 Jan 2021
2 Jan 2021
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) complete, all as directed.
Dismantling of brick tiles or terracing tiles single layer on roofs including demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
S&F plain, solid, straight chowkats and frames of second class hardwood, wrought, framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints, complete all as specified & directed.
S & F factory made 25mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F butt hinges of size 50mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S&F 100mm long extruded aluminium alloy handles, fabricated type, anodised (ISI marked) complete all as specified.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised (ISI marked) complete all as specified.
S&F hasp and staple of size 100mm aluminium anodized safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified.
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps 30mm (when open) fixed with CP steel screws.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified.
S&F in repairs 4mm GI wire (for net mosquito) and adjusting the level & fixing to walls by means of cleats / hold fasts made out of GI flat 40x3mm of size 300mm long with 'L' & 'T' type base of size 300mm long, 02 Nos cleats / hold fasts to be provided in 20m internal of GI wire and fixed in PCC bed block 1:2:4 type B0 (using 12.5mm graded stone aggregate) of size 300x230x230mm with and including cutting / chieling of brick walls complete all as specified.
S&F in repairs prelaminated PVC solid board (Plastiwood/PVC plywood) 18/19mm thick, prelaminated on one side with decorative choice lamination & other side balancing white lamination including pasting with solvent chemical as required in Kitchen cabinet / shelves including openable shutter to kitchen cabinet etc or fixed with screws including ball catch with cabinet shutter complete all as specified & directed.
M&L for preparation of RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles. Filling the cracks by crack filler Providing 50mm thick average thickness (Thickness of PCC 70mm at centre and 30mm at outer edge of roof surcae) PCC 1:3:6 type C1 (using 20mm graded stone aggregate) at the places where slope is not proper or roof surface is uneven to maintain the proper roof slope complete all as directed.
M&L for Providing 25mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30%) over slab and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm and applying 2nd coat solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm over dried 1st coat complete all as specified and directed. Note :- The work of WPT shall be got executed through authorised approved applicator.
M&L for cement concrete (1:3:6) type C1 using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and as directed.
M&L for non skid ceramic jointless tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid designer ceramic jointless tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic designer jointless tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile exceeding not 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for glazed ceramic designer & pattern (dark & light shade) jointfree tiles (coloured) 450mm x 300mm x 7mm thick, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified. Note : - Kota stone shall be of size 550mm x 550mm (minimum) when brought at site.
M&L machine cut Kota stone slab 15 to 20mm thick , as in skirting etc. laid over & including screed bed or bedding layer of 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
M&L for Granite (of any type) tiles 18-20mm thick machine cut, as in floor, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for rendering 12mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L rendering 10mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement complete all as specified and directed.
Material and labour preparation of newly plastered cement surfaces of walls & applying three coats of white wash complete all as specified.
Material and labour preparation of newly plastered cement surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved shade/tint complete all as specified and directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coats of white wash complete all as specified & as directed.
M&L for 50mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Taking up or down 15mm bore steel tubing and connection from any position with or without concealed type incl cleaning for refixing or removal to store.
Taking up or down 20mm bore steel tubing and connection from any position with or without concealed type incl cleaning for refixing or removal to store.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
Fixing only GI water tubing 15 mm bore, medium grade, with & including supply & fixing all new fittings (ISI marked) complete fixed to walls and ceilings or laid in floors all as specified & as directed. Notes :- (i) Old serviceable water tubing retrieved from serial item No. 36.00 here-in-before shall be used. (ii) Quoted rate shall be deemed to include cost of GI fittings (ISI marked). Old fittings shall not be used.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
Fixing only GI water tubing 20 mm bore, medium grade, with & including supply & fixing all new fittings (ISI marked) complete fixed to walls and ceilings or laid in floors all as specified & as directed. Notes :- (i) Old serviceable water tubing retrieved from serial item No. 37.00 here-in-before shall be used. (ii) Quoted rate shall be deemed to include cost of GI fittings (ISI marked). Old fittings shall not be used.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall.
S&F in repairs 15mm bore bib tap standard of PTMT any colour, high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and as directed.
S&F in repairs 15mm bore Pillar taps (fancy type) of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-110gms) complete all as specified and directed.
S&F in repairs 15mm bore Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and directed.
S&F in repairs 15mm bore angle valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and directed.
S&F in repairs 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F in repairs 15mm bore stop valve, fancy type , chromium plated cast copper alloy screwed down, high pressure, with long shank and cup (concealed type) with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed.
S&F in repairs shower rose of PTMT any colour for fixing with 195mm long with bend of 45 degree with flange of PTMT (Minimum wt 80 gms) etc complete all as specified and directed.
S&F in repairs Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) all as directed.
S&F in repairs single/multi PVC (SWR) floor trap dia of outlet 75mm, with PTMT grating including jointing with solvent cement all as specified.
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F in repairs Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and plastic cleats (Minimum weight 190gms) complete all as specified..
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, with PTMT trap of suitable size 'P' or 'S' , including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
S&F in repairs vitreous china wash down water closet (Padestal pattern) White, with 'P' or 'S' trap including plastic water closet seat cover, white, closed pattern with flat bottom with mild steel chromium plated or aluminium hinging device and fixing with all joints including connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets duly painted with two coats of synthetic enamel paint over a coat of red oxide primer embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe 90cm long, and 32mm bore PTMT waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified.
M&L for treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical surfaces upto finished floor level) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40mm thick avgerage PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for providing spout 50mm bore GI pipe medium grade of length 0.50m and fixed all as specified. (ii) M&L for providing rendering of uneven surfaces of vertical sunken with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturers instruction to bottom and vertical sides up to finished floor level and 100mm aove FFL , the thickness of two layer shall be 1mm and when the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (iv) M&L for providing plaster to the bottom and sides up to FFL with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (v) The sunken floor shall be filled with lean concrete 1:7:12.
Note :- (i) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iii) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (iii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint and cost is deemed shall be included in quoted rates. (iv) Cost of WPC shall deemed to be included in quoted rates. (v) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-charge and record for each sunken slab shall be maintained. (vi) The treatment shall be carried out in presence of Engineer-in-charge and tested. Cost of testing is inclued in the rates quoted above. (vii) For Payment purpose, the Plan area of Sunken floor shall be taken into account.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. (measured overall as fixed along the centre line over fitting and accessories) complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified.
S&F 110mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F 75mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified.
Balaji Construction Co.
Shiva Constructin Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .