Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC QUOTED L1 |
| 2 | L2₹1.1 Cr+₹2.5 L (2.29%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹1.1 Cr+₹2.5 L (2.29%) | L2 | Rejected-AOC NOT ADMITTED |
| 3 | L3₹1.1 Cr+₹6.6 L (6.15%)Rejected-AOC | ₹1.1 Cr+₹6.6 L (6.15%) | L3 | Rejected-AOC NOT ADMITTED |
| 4 | L4₹1.2 Cr+₹11.4 L (10.7%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.2 Cr+₹11.4 L (10.7%) | L4 | Rejected-AOC NOT ADMITTED |
| 5 | L5₹1.2 Cr+₹13.1 L (12.3%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹1.2 Cr+₹13.1 L (12.3%) | L5 | Rejected-AOC NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
28 May 2022, 6:00 pmClosed
CWE Subs Mumbai
HQ CWE Subs Mumbai, NCH Colony, Powai, Bhandup Post, Mumbai -400078
Addn altn and improvement to bldg No SPDC 1 and SPDC 02 at MO MB Ghatkopar
2022_MES_521586_1
8428/E8
Open Tender
Civil Works
Works
300 days
GE NW Bhandup
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE NW Bhandup
₹2.2 L
Yes
4 Aug 2022
4 May 2022
30 May 2022
4 May 2022
28 May 2022
17 May 2022
Amount
Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size & pattern) including all fitting, head shoes, bends etc complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S&F 1mm thick GI sheet in ridges hips, valley gutters, drip etc welded or soldered joints with grade of zinc coating 275 including neccessry arangement for leakage proof drop in to rain water pipes 160mm dia complete all as spd and directed.
S&F 2 mm fibre glass reinforced translucent corrugated sheeting of a similar pattern as that of PPGI sheet with two corrugations side lap fixed with GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F 160mm bore PVC rain water pipe single socketed (ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails, provision of water seal proofing with valley gutter etc complete all as specifed and directed.
Dismantling wrought iron or mild steel work of valley gutter and expended metal any description complete all as specified and directed..
S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats, notching, drilling, fitting, riveting and /or welding, bracing or connecting with bolts and nuts (incl rivets or bolts and nuts) etc,Fe-410W (Gde-E-250)quality -B, including necessary scaffolding etc complete all as specified and directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports, wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on brick walls, RCC pillars, beams etc and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick cement plaster in two coats using factory manufactured pre mix/ready mix mortar of Roof it Mix of M/s Premier floor to roof Materials Pvt Ltd/Easy plast of M/s Walplast products Pvt Ltd/Readiplast of M/s Ultratech cement Ltd/Soundplast PMC-1 of M/s Sound build care Pvt Ltd/ or other approved equivalent make, having minimum composition to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechanical mixing with water in metalic tray only to make good consistency as per the specification of manufacturing and applied over exterior masonry and concrete surfaces with base coat of 18mm thick and finishing coat of 5mm thick final rendering, including using richer mix for making comers if necesary, at all floor and level, including making grooves of existing size wherever required, including clleaning the surfaces, curing etc. complete all as specified and directed. Note : Work shall be executed at Multiple places as per requirement and at up to 8mts height.
Supply only integral water proofing compound.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed. Note :- Height of the structre is more than 7 mtr and necessary scaffolding and jack will be provided at the time of work.
M&L for reinforced cement concrete 1:1.5: 3 (nominal mix) using 20mm graded aggregate as in beam , cantilever , lintel over 1.5 m span complete all as specified and directed ( Note: reinfocement and form work shall be measured and paid seperately.
M&L for form work to sides and soffits of roof beam , lintel , cantilever etc for fair finished flat surface complete all as spd and directed .
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping for columns hooking ends and bonding with and incl mild steel wire not less than 0.90 mm dia or securing with clips complete all as speficied and
M&L for mild steel TMT bars 8 mm dia and over cut to length bent to shape required in stirrups and binding cranking bending spirally for hooping for columns hooking ends and bonding with and including mild steel wire not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M & L for removing loose, disturbed or disintegrated old concrete surfaces of RCC beam, column, lintel, pardi, railing etc, cleaning throughly exposed reinforcement, preparing exposed concrete surfaces to receive guniting, applying anti corrosive paint to the exposed reinforcement, supply and fix welded wire mesh of size 100 x 100 mm of 3 mm dia wire, weight not less than 1.37 Kg/Sqm & binding with 22 gauge binding wire to reinforcement and applying pressure guniting in cement mortar 1:3, minimum thickness 30 mm and thereafter rendering 10 mm thick plaster in cement mortar 1:3, mixed with water proofing compound 2% by weight of cement and finishing the surface even and smooth without using extra cement to match the existing surfaces, removing the debris outside MD land including material and labour for necessary scaffolding and safety arrangement for guniting work complete all as specified and directed (Note :- The finished surfaces to be matched with the existing surface. WPC Shall be measured & paid separately)
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces and applying one coat of white wash on wall, columns, beams etc complete all as specified and directed..
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for complete removal of existing treatment on walls including washing down, rubbing down and applying antifungal treatement as required and applying two coats of 100% antiffungal weather coat exterior emulsion acrylic emulsion paint over a coat of primer complete as specified and directed by Engr-in-Charge
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
M&L for preparation of old steel surfaces and applyingone coat of synthetic enamel paint complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete as directed
S&F aluminium section in doors/windows/ventilators ,any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing glass/XPM jali and all necessary fittings complete, screws, plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of bakelite sheet glass pane,wire mesh will be measured separately.
S&F only 4.80mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator n exc 0.50 Sqm each pane all as specified & as directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
S&F machine cut kota stone slab flooring 20-25mm thick as in windows cill jambs and soffit etc over 15mm thick cement mortar 1:4 screed base laid jointed with grey cent mixed with pigment incl rubbing polishing complete all as specified and directed .
Dismantling carefully reinforced cement concrete work (including cutting of the reinforcement as required to facilitate dismantling) with low Impact Hammer / Breaker without dismantling the structure of any description and in any position not otherwise specifically provided for, cleaning and removing the retreived debris out side MD land, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces , complete all as specified and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for building up the profile of structural members using polimer modified mortar M/S krishna conchem (Mohit PMM) or polimer mortar HB of Dr fixit n exc 20mm thick incl levelling profiling etc all as spd
M&L for building up the profile of structural members using polimer modified mortar M/S krishna conchem (Mohit PMM) or polimer mortar HB of Dr fixit exc 20mm and n exc 40mm thick including levelling profiling etc complete all as spd and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately).
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and disposing off the rubbish outside MD land complete all as specified and directed.
M&L PCC 1:3:6, C-2 (using 40mm graded crushed stone aggregate) as in plinth protection, sub base of floor ( 75mm thick ) finished even and fair complete all as specified and directed.
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free or equivalent) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed.
Demolition of RCC structure such as gantry wall, pillar, column, beam etc ( below or above ground level) in any thickness complete all as specified and directed..
M&L for injecting chemical GLYPHOSPHATE 41% SL 20 ml or till refusal by making cuty/injection of the stem of plant 30 mm C/C and spraying with solution (25 ml GLYPHOSPHATE 41% diluted with 1 ltr of water) and removing the plant/vegitation including penetrated roots complete including necesary scaffolding etc all as specified and directed for plants/vegetation
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S&F turbine Air Ventilator dia 700mm, height 421 mm, Neck/Throat dia 530mm / 710mm. Top cone MOC & Grade Stainless Steel 304, Dia 460mm, No of fins 36, thickness 0.5 mm and Neck/bottom ring of shaft Dia 525mm width 120mm, Shaft MOC 19mm dia SS, Drive mechanism SS boll supporting brush MOC matlon, FRP base with dome MOC & grade 450 Imerson, sheet size 1050mm x 1800mm, Hood size 530 mm, opening at bottom base 900mm x 600mm, Exhaust capacity 1900 CFM, Net weight / Gross weight 8 Kg / 14 Kg and including necessary fixing arrangement, scaffolding etc, complete all as specified and directed. Note :- The height of the store houses are more than 8 mtr. All the safety precautions must be ensured by the tenderer.
Taking down carefully copper/aluminum point wiring of any type such as Concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
M&L for surface point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including stove enamelled steel conduit having thickness not less than 2 mm with all fittings including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of copper wire:Le Grand/Havells/Polycab and PVC conduit Make: Precision,Plaza) 2. Modular steel sunken boxes and switch sockets measured and paid separately.
All as per srl item No 49 above but for 5 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per srl item No 49 above but for 5 pin 5 amps socket outlet on indenpendent board of light point all as specified.
M&L for surface point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including stove enamelled steel conduit having thickness not less than 2 mm with all fittings including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained. (Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire :Legrand/standard/Havells and PVC conduit Make: Precision,Plaza) 2. Modular steel sunken boxes and switch sockets measured and paid separately.
Supply and fixing modular ceiling fan regulator 120 watt 2 module AC 240 volt complete all as specified and directed.
M&L for switch modular one way 6/10 amps 1 module complete all as specified.of make: legrand/ Havells/Anchor(Roma)
M&L for switch modular one way 16 amps 1 module complete all as specified.of make: legrand/ Havells/Anchor(Roma)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
M&L for socket modular 6/16 Amp 2/3 pin combined 2 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
Supply and fixing modular metal flush box 3 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
Supply and fixing modular metal flush box 6 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
Supply and fixing modular metal flush box 8 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.make: legrand/ Havells/Anchor(Roma)
M&L for submain wiring in and including steel conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed.Make:Legrand/Havells/polycab Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 4 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Make: Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted MCB DB TPN 415 Volts 4 way double door vertical type with 200 Amps rated bus bar din rail neutral link all as specified and directed.Make: Legrand/Schneider/Siemens.
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 6 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.Make: Legrand/Schneider/Siemens.
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 8 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCCB 4 pole 415 volts 16 KA TPN 100 Amps complete all as specified.Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCCB 4 pole 415 volts 16 KA TPN 63 Amps complete all as specified.Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB 415 volts 16 KA TPN 63 Amps complete all as specified.Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB 415 volts 16 KA TP 32 Amps complete all as specified.Make: Legrand/Schneider/Siemens
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates.(ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also be provided by the contractor .
Material and Labour for tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: Havells /CG/Luker/Shakti Fixtures
Supply and fixing in repairs highly efficient high power multi LED flood fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Havells /CG/Luker/Shakti Fixtures.
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP656,LEDs 100 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting complete.Make: Make: Havells /CG/Luker/Shakti Fixtures
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP656,LEDs120 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting complete.Make: Make: Havells /CG/Luker/Shakti Fixtures
Supply and fix in repairs ceilling rose 3 terminal all as specified and directed.Make -Cona,Anchor,Indo Asian
M&L for self level coloured epoxy flooring in patches 5mm thick with as per manufacturer specification complete all as specified and directed
Supply and fix in repairs MCB SPN 240 Volts 40 to 63 Amps breaking capacity 10 KA rating complete all as specified and directed.Make :Legrand/Schneider/Siemens
Vishal Builders
S R INFRASTRUCTURE
Parmatma Enterprises
MUKESH CONSTRUCTION CO
the bhimani group of companies
SHAILENDRA B TULSANI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .