Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹34.2 L+₹1.4 L (4.38%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹35.8 L+₹3.0 L (9.25%)Rejected-Finance | L3 | Rejected-Finance other than L1 | |
| 4 | L4₹37.1 L+₹4.4 L (13.3%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance other than L1 |
| Sl No | Description | Qty | Unit | MB Enterprises L4 | Iconic Engineers L3 | M/s Dhapola Elevator and Engineering L1 | M/S Anand Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00Comprehensive, preventive and periodical maintenance of lifts/elevators/dumbwaiters installed in AHRR Complex as mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise consultancy by regularly/periodically examining(as per OEM guideline), lubricating and adjusting the mechanical and electrical driving equipment. The scope of work incl replacement of unsv componenents as and when required such as, governor sleeve, shaft assembly, bearing / contact, governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, counter weight, guide rails, buffers, machines motors, generators, door ropes, UPS/ARD system, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock brake shoes, liners, contactors, relays, coils, pushbuttons, door operator VVF drive, VVVF main drive, cardoor safety device, limit switches, governor, hoistway door locks, indicators and other machanical and electrical parts (excpet car cabin, landing door, sheave rim and Srl item No 02 to 28 of Sch 'A') for smooth functioning of elevators and incl all machine works i.e. welding, cutting, drilling, screwing, etc. as and when required, to entire satisfaction of Engineer-in-charge, incl cost of materials complete incl Sunday and holiday all as specified & directed for following Lift(s) / Elevator(s) - | |||||||
| 1.01 | Electric Hospital passneger cum stretcher elevator /lifts of capacity 26 passenger serving (G+4) 5 floors installed at A Block lift No 02 & 03 (Make : TKE Elevator) -02 Nos lifts | 24 | Per Lift Per Month | 11,500 ₹2,76,000 | 8,500 ₹2,04,000 Lowest | 12,000 ₹2,88,000 | 9,500 ₹2,28,000 |
| 1.02 | Electric Hospital passneger cum stretcher elevator / lifts of capacity 26 passenger serving (-1+G+4) 6 floors installed at OT(Lift No 04 & 05) (Make TKE Elevator) -02 Nos lifts | 24 | Per Lift Per Month | 11,500 ₹2,76,000 | 8,500 ₹2,04,000 Lowest | 11,500 ₹2,76,000 | 9,500 ₹2,28,000 |
| 1.03 | Electric Hospital passneger cum stretcher elevator / lifts of capacity 20 passenger serving (G+4) 5 floors installed Ramp side (Lift No 7 & 8) (Make Thyseen Krup Elevator) -02 Nos lifts | 24 | Per Lift Per Month | 11,500 ₹2,76,000 | 8,500 ₹2,04,000 Lowest | 11,850 ₹2,84,400 | 9,500 ₹2,28,000 |
| 1.04 | 20 passenger elevator of 1360 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 03 Nos installed at CTVS . | 36 | Per Lift Per Month | 21,500 ₹7,74,000 | 24,600 ₹8,85,600 | 16,500 ₹5,94,000 Lowest | 20,000 ₹7,20,000 |
| 1.05 | 10 passenger elevator of 680 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 02 Nos installed at CTVS . | 24 | Per Lift Per Month | 21,500 ₹5,16,000 | 23,100 ₹5,54,400 | 15,560 ₹3,73,440 Lowest | 20,000 ₹4,80,000 |
| 1.06 | 250 Kg Dumb Waiter (G+1) (Make : KONE Elevator) - 01 Nos installed at CTVS . | 12 | Per Lift Per Month | 16,000 ₹1,92,000 | 10,300 ₹1,23,600 | 15,000 ₹1,80,000 | 10,000 ₹1,20,000 Lowest |
| 1.07 | 250 Kg Dumb Waiter (G+2) (Make : KONE Elevator) - 01 Nos installed at CTVS . | 12 | Per Lift Per Month | 16,000 ₹1,92,000 | 10,300 ₹1,23,600 | 16,000 ₹1,92,000 | 10,000 ₹1,20,000 Lowest |
| 1.08 | 10 passenger elevator of 680 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 03 (G+2)(Make : KONE Elevator) – 02 Nos installed at ADC Block . | 24 | Per Lift Per Month | 19,500 ₹4,68,000 | 19,500 ₹4,68,000 | 15,000 ₹3,60,000 Lowest | 19,000 ₹4,56,000 |
| 1.09 | 15 passenger elevator of 1020 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 03 (G+2)(Make : KONE Elevator) – 01 Nos installed at ADC Block . | 12 | Per Lift Per Month | 21,500 ₹2,58,000 | 19,500 ₹2,34,000 | 15,000 ₹1,80,000 Lowest | 19,000 ₹2,28,000 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
29 Sept 2025, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI RAO TULA RAM MARG DELHI CANTT-10
COMPREHENSIVE, PREVENTIVE AND PERIODICAL MAINTENANCE OF LIFTS AT P-100 , CTVS AND MD ACCN AT AHRR UNDER GE EM RR HOSPITAL, DELHI CANTT
2025_MES_728875_1
CWE-ND/36/2025-26
Open Tender
Civil Works - Others
Item Rate
365 days
DELHI CANTT
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE E/M RR HOSP DELHI CANTT
₹82,000
5 Dec 2025
2 Sept 2025
1 Oct 2025
2 Sept 2025
29 Sept 2025
17 Sept 2025
Amount
Comprehensive, preventive and periodical maintenance of lifts/elevators/dumbwaiters installed in AHRR Complex as mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise consultancy by regularly/periodically examining(as per OEM guideline), lubricating and adjusting the mechanical and electrical driving equipment. The scope of work incl replacement of unsv componenents as and when required such as, governor sleeve, shaft assembly, bearing / contact, governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, counter weight, guide rails, buffers, machines motors, generators, door ropes, UPS/ARD system, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock brake shoes, liners, contactors, relays, coils, pushbuttons, door operator VVF drive, VVVF main drive, cardoor safety device, limit switches, governor, hoistway door locks, indicators and other machanical and electrical parts (excpet car cabin, landing door, sheave rim and Srl item No 02 to 28 of Sch 'A') for smooth functioning of elevators and incl all machine works i.e. welding, cutting, drilling, screwing, etc. as and when required, to entire satisfaction of Engineer-in-charge, incl cost of materials complete incl Sunday and holiday all as specified & directed for following Lift(s) / Elevator(s) -
Electric Hospital passneger cum stretcher elevator /lifts of capacity 26 passenger serving (G+4) 5 floors installed at A Block lift No 02 & 03 (Make : TKE Elevator) -02 Nos lifts
Electric Hospital passneger cum stretcher elevator / lifts of capacity 26 passenger serving (-1+G+4) 6 floors installed at OT(Lift No 04 & 05) (Make TKE Elevator) -02 Nos lifts
Electric Hospital passneger cum stretcher elevator / lifts of capacity 20 passenger serving (G+4) 5 floors installed Ramp side (Lift No 7 & 8) (Make Thyseen Krup Elevator) -02 Nos lifts
20 passenger elevator of 1360 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 03 Nos installed at CTVS .
10 passenger elevator of 680 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 02 Nos installed at CTVS .
250 Kg Dumb Waiter (G+1) (Make : KONE Elevator) - 01 Nos installed at CTVS .
250 Kg Dumb Waiter (G+2) (Make : KONE Elevator) - 01 Nos installed at CTVS .
10 passenger elevator of 680 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 03 (G+2)(Make : KONE Elevator) – 02 Nos installed at ADC Block .
15 passenger elevator of 1020 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 03 (G+2)(Make : KONE Elevator) – 01 Nos installed at ADC Block .
Notes for item No. 1.00 to 1.09: (i) The above maintenance shall be done through OEM of existing lifts. Please also refer Sch 'A' Notes. (ii) The contractor shall have to submit MOU from OEM M/S TKE (for Item No. 1.01 to 1.03) and submit MOU from OEM M/S KONE (for Item No. 1.04 to 1.09). (iii) The rates quoted shall be inclusive of T&P required for carrying out repairs, stationary for maintenance of record all as specified. (iv) All the cleaning items (Dusting cloths, floor/Glass cleaner, SS steel cleaner, broom etc) shall be provided by the contractor and rates deemed to be included in the quoted rate. Otherwise a penalty of Rs. 100/- per day will be charged. (v) Any items not covered in Sch 'A' (except car cabin, landing door, sheave rim and Srl Item No 02 to 28 of Sch A) shall be deemed to be included in the unit rate quoted for above item for the smooth functioning of lifts and the contractor may quote the rate accordingly. Contractor is expected to inspect the lift before quoting the rate and Lifts will be handed over in the same condition. No claim will be admissible thereof.
Notes for item No. 1.00 to 1.09 (contd.):- (vi) Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, penalty shall be charged as given below:- (a) up to 1st day- NIL (b) 2nd day- Rs 1000/- day (c) Subsequency for every days - Rs 2000/day. (vii) Contractor shall be responsible to register the day to day complaints of lifts and addressed the same with in the stipulated timeframe and the complaint register will be putup to the JE / Engr-in-charge on daily basis. (viii) The comprehensive / preventive / periodical maint incl fortnightly, monthly, quarterly, half yearly inspection / testing as per service manual or as per IS standard will be submitted to Engr-in-charge. (ix) Contractor shall submit safety security certificate of lifts from OEM in every month as per performa mentioned in tender documents. (x) Adequate arrangements shall be made to dewatering the lift pit as and when water accumulates. Cost Should be included in the quoted rate. Otherwise penality of Rs 500 per day per lift will be recovered from the contractor. (xi) Contractor shall be responsible to update the imp tele number and safety precautions of inside the car cabin of each lifts and update the same time to time.
Supply & fix in replacement of SMF Battery 12 V 18 AH or all as per site requirement complete all as specified & directed.
Supply & fix in replacement of SMF Battery 12 V 12 AH or all as per site requirement complete all as specified & directed.
Supply & fix in replacement of SMF Battery 12 V 7 AH or all as per site requirement complete all as specified & directed.
S&F in replacement MCB SP 6-32 Amps complete all as directed.
S&F in replacement MCB TPN 63 Amps complete all as directed.
Supply and fix in repair, of blower/car cabin fan by taking down unserviceable blower/fan complete all as specified and as directed.
Supply & fix in replacement as in shaft light of lift environmental friendly, ultra modren, energy saving LED fitting 20W with all connection incl wiring all as per site requirement complete all as specified and directed.
S&F in replacement cabin light decorative recess mounted round/square fixture (as per existing size and type) in white finish with opal diffuser and electronic driver, suitable for car cabin complete all as per site requirement directed by Engr-in-Charge.
Supply & fix in replacement travelling cable multistranded copper conductor of size 12 core 0.5 sqmm as pe OEM all as directed by Engr-in-Charge.
M&L for replacement of GI earth plate 600 x 600 x 6 mm including replacement of pit cover and providing salt and charcoal mixture complete including chamber as per requirement all as specified and as directed.
S&F in replacement of GI earth strip 25 x 6 mm complete all as specified and as directed.
M&L for replacement of lift facia made of stainless steel of existing thickness including ply board complete all as specified and as directed
M&L for replacement of pit stop switch, cable 2 m complete all as specified and as directed.
M&L for replacement of swing arm tension weight assembly complete all as specified and as directed
M&L for replacement of ROPE, PAWO F1 6NAT6X19 FC1770SZ complete all as specified and as directed
M&L for replacement of NUMERIC UPS DEVICE, 600VA 230V 1PH complete all as specified and as directed
M&L Repair and adjsutment/alignment of car door and lift sills in safe and smooth manner incl welding, grouting, screw, nuts, bolt etc complete all as directed.
S&F contactor four pole 40 A, AC 415 V complete all specified and as directed
S&F MCCB 63 A 415 V, 16 kA, 4 Pole, complete all as specified and as directed
S&F RCCB 25 A double pole, 30mA complete all as specified and as directed.
S&F RCCB 40 A four pole, 300mA complete all as specified and as directed.
S&F RCCB 63 A four pole, 300mA complete all as specified and as directed.
S&F MCCB 100 A 415V, 16kA, 4 pole complete all as specified and as directed.
Supply and fix in repair, Metallic body exhaust fan of 380 mm sweep, single phase including necessary addn/altn to accommodate at the existing location or making provision by cutting/chasing wall and making good the disturbed surfaces, matching with the existing colour of wall all as directed by Engr-in-Charge.
S&F LED Fitting 1X 9 W/ 1X10 W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F in replacement copper cable 1.5 Sqmm single core, 1100V PVC round sheathed flexible type complete all as directed.
M&L for replacement of transparent acrylic sheet for lift car ceiling of existing type and ceiling size complete all as specified and as directed by Engr-in-Charge
M/S Anand Enterprises (BID ID -3438632)
Iconic Engineers (BID ID -3432051)
MB Enterprises (BID ID -3429790)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .