| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹16.6 L+₹1.7 L (11.7%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹42,480
Closing Date
23 Jan 2021, 6:00 pmClosed
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR - 62 OF 2020-21 SPECIAL REPAIRS FOR REPLACEMENT OF OLD UNSERVICEABLE LT PANEL, MCCB AND LT / UNDER GROUND CABLES IN OTM ACCOMMODATION AT MILITARY STATION FAZILKA (2ND CALL)
2020_MES_383969_2
CA NO. CWE SGNR - 62 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ABOHAR
Class E
Category b(i)
10 documents required · 10 mandatory
₹500
GE ABOHAR
₹42,480
Yes
22 Feb 2021
2 Jan 2021
26 Jan 2021
2 Jan 2021
23 Jan 2021
9 Jan 2021
Amount
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and directed by Engineer-in-charge
M&L for aggregate for loose filling of gauge 80mm to 150mm graded stone aggregate as in foundation of platform fencing area complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable underground LT Cable of 4/3.5 core, 10 Sqmm to 70 Sqmm from trenches/floor/road/pipe/along poles including taking out old bricks complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work required for item shall be measured and paid separately under respective items of BOQ.
Supplying, laying, jointing and testing and commissioning 6 sqmm, 2 core XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 6 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 10 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 10 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 25 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 35 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 50 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 95 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 120 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 11 here-in-before but cable of cross sectional area 150 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
Disconnecting of LT supply and opening bus bar chamber / cable box chamber of outdoor / indoor LT Panel, removing of burnt out lugs, MCCB/ MCB of any capacity and size and cleaning of bus bar with CTC solutions, insulating the bus bar by taping with RYB colours, necessary nut bolts of existing size and refixing after repairs complete all as specified and directed by Engineer-in-Charge. Note : (i) Aluminium lugs of any size as per site shall be measured and paid for separately. (ii) MCCB/MCB of any capacity shall be measured and paid for separately.
Supply and Fixing for MCCB 4 pole 63 A , 415 V, 50Hz having breaking capacity 16KA with all fitting accessories complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing for MCCB 4 pole 100 A , 415 V, 50Hz having breaking capacity 16KA with all fitting accessories complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing for MCCB 4 pole 125 A , 415 V, 50Hz having breaking capacity 16KA with all fitting accessories complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 3 pole 160 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 3 pole 200 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 3 pole 250 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as specified and directed by Engineer-in-Charge.
S&F ACB 4 Pole, 415 Volt, with thermal magnetic release (Manual Fixed Type) of capacity 630 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for servicing ACB by taking out Air Circuit breaker of capacity 400-1250 Amps from LT panel cleaning all parts internally and externally checking of the proper tentionof mechanical springs and switching mechanisim, tightning of connections of moving, fixing contacts, floating contracts, servicing of motors and charging system and refixing it on its original position and testing of control wiring to operational complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of shutter assembly suitable for 3/4 pole ACB upto 630/800 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of arc chute (set of 3) suitable for 3/4 pole ACB upto 630/800 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of floating isolating contact (set of 3) suitable for 3/4 pole ACB upto 630/800 Amps capacity complete all as specified and directed by Engineer-in-Charge.
Supplying and laying in replacment of synthetic insulating mat of size 2mtr x 1mtr x 10mm complete all as specified and directed by Engineer-in-Charge. Make : The item should be ISI Marked and as approved by GE
S&F for self adhesive reflective radium stickers 75mm x 12Mtr wide around the steel light poles 1.5mtr above the ground level complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 6 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 10 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 16 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 25 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 35 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 50 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 70 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 120 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 150 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fix for GI Pipe 80mm bore light grade for protection of cable incuding provision of clamps, nuts, bolts etc. required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge. Note : Excavation and earth work shall be measured and paid separately under respective item(s) of BOQ.
Supply and fix in repairs GI pipe 40mm bore light grade for protection of cable including provisionof clamps, nuts, bolts, etc. required for fixing pipe along pole / wall / laid under the road / laid under the floor or trenches complete all as specified and directed by Engineer-in-Charge.
M&L for cutting, trimming bushes, weed / tidy plants to bring in a cleaned position and level the area around / inside near E/M installation and making good of LT panel / two, four pole structure / substation / transformer yard without disturbing installed accessories / equipments by using cutting equipments hacksaw, axe, ladders, sword, trimmer for well groomed with safety measures etc incuding disposal of trimmed branches 100 Mtr away inside the cantonment area and cleaning the area complete all as specified and directed by Engineer-in-Charge.
Supply and fix on-load change over switches, 4 pole in open execution of capacity 63 Amps complete taking down old unserviceable one and making necessary connections incuding all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 51 here in before but for 100 Amps rating complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 51 here in before but for 150 Amps rating complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 51 here in before but for 200 Amps rating complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 51 here in before but for 320 Amps rating complete all as specified and directed by Engineer-in-Charge.
M&L in repairs Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht strip 32x6mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B1 including CI cover with frame 40x40x6mm angle iron frame on top of pit cover and excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. (Payment to be made after result should berequired less than 5 Ohm) Notes :- (i) GI wire upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber. (iii) Water pipe upto earth pit shall be provided in slanting position as included in this item. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,01,930.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 23 (Schedule of Credit) of Tender document
Singla Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .