Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC Awarded as a lowest (L1) | |
| 2 | L2₹43.5 L+₹4.0 L (10.1%)Rejected-AOC B 3 3 DHANALAXMI PARK OPP PMT BUS DEPOT BHUSARI COLONY PAUD ROAD KOTHRUD PUNE 411 038 | PUNE | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-AOC Being second lowest (L2) | |
| 3 | L3₹44.2 L+₹4.7 L (11.9%)Rejected-AOC 26 3 BOMBAY PUNE ROAD LAXMI APARTMENT OPP BU BHANDARI SHOWROOM PUNE 411003 | PUNE | MAHARASHTRA | 411003 | L3 | Rejected-AOC Being third lowest (L3) | |
| 4 | L4₹46.4 L+₹6.9 L (17.6%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L4 | Rejected-AOC Being fourth lowest (L4) | |
| 5 | L5₹48.0 L+₹8.5 L (21.5%)Rejected-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L5 | Rejected-AOC Being fifth lowest (L5) |
Tender Value
Refer Docs
EMD Value
₹81,000
Closing Date
9 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
PROVISION OF CERTAIN SANCTIONED WORKS AT HEMRL UNDER GE RD PASHAN
2021_MES_471759_3
GERD/PSN/TOKEN/25 OF 2021-22
Open Tender
Civil Works
Item Rate
210 days
GERD PASHAN PUNE
As per tender documents
9 documents required · 9 mandatory
₹500
GERD PASHAN PUNE
₹81,000
Yes
3 Jan 2022
22 Nov 2021
13 Dec 2021
23 Nov 2021
9 Dec 2021
2 Dec 2021
23 Nov 2021 - 1 Dec 2021
60 days
Amount
Dismantling of wrought iron and steel work of any description and in any position as any fencing grills complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement morter or cement lime mortar including all quoins,pillars,arches etc, and clearing off the premises complete all as specified and directed.
Excavation in trenches not exc 1.5m height wide and not exc 1.5m wide and not exc 1.5m in depth and getting out in soft disintegrated rock complete all as specified and directed.
Removing excavated material to a distance upto 250m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Returning filling in including spreading ,levelling , watering & well ramming in layers not exc 25cm complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for walling of random rubble, uncourse, well bonded, bedded and solidly hearted, built in cement mortar 1:6 including provision of precast PCC bond stones complete all as specified and directed.
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone (using serviceable old stones obtained from demolation) complete all as specified and directed.
Material and labour for extra over stone walling for hammer dressing to face stones and dressing or face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses 20 mm deep in granite or trap stone complete all as specified and directed.
Material and labour for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar (1:3) complete all as specified and directed.
Material and labour for Joist, channel, angle, or tee sections, fixed independently, without connection plate,as in fencing post etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply and fixing of mild steel angles,bars, flats etc as in supports for posts and struts in fencing including cutting tops to shape as directed,drilling holes,notching for wire,etc, flat iron fillets (For securing wire mesh etc.,) including all necessary drilling,bolting or riveting,etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
Material and labour for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm & n exc 10cm long dia of neck 11 to 15mm complete all as specified and directed.
Material and labour for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 Gde E-165 complete all as specified and directed.
Material and labour for preparation of new steel surfaces any description over 10 cm width /girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolition & breaking up drain pipes (salt glazedwere/AC/RCC ) set in cement mortor,of any internal dia of pipe ie 200 mm complete all as specified and directed by Engineer in Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and exc 1.5m but n. exc 3.0m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan getting out in soft/ loose soil complete all as specified and directed.
Demolition of unreinforcement cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for reinforced concrete pipes, class NP2, laid and jointed with collars of dia 200 mm complete all as specified and directed.
Material and labour for PCC (1 : 3: 6 ) type C2(using 40 mm graded aggregate) as in bed to drain pipe including packing under & haunching against the sides of pipes of 200 mm dia after they are laid tested complete all as specified and directed. Note: Thickness of bed below pipe shall be 10cm and width shall be outer dia of pipe plus 30cm.
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour precast concrete block masonry Type C1 1:3:6 (20mm graded crushed stone aggregate) with solid blocks exc 10cm in width and setting in cement mortor 1:4 complete all as specified and directed by Engineer- in -Charge.
Material and labour for Rendering 15mm thick on brick work or concrete surfaces in two layers i.e 10+5mm in cement mortar 1:4 including WPC surface even and smooth (without using extra cement) complete all as specified and directed. Note: WPC shall be measured and paid seprately.
Material and labour for rendering 10mm thick in cement mortar 1:6 on brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Removing excavated material to distance n exc 50m and depositing where directed at a level n exc 1.5m height complete all as specified and directed.
Demolition of Reinforcement cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Material and labour for providing, precast cement concrete type B1 1:2:4 using (20mm graded crushed stone aggregate) in cement cement mortar 1:4 but in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and setting in mortar complete with joints to match complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Supply and fixing PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Material and labour for external angles (for quoins and jambs) in facings for walling of random rubble or polygonal rubble, uncoursed or brought upto courses and squared rubble masonry, regular coursed, Secunderabad and Bangalore types complete all as specified and directed.
Material and labour for plain cement concrete in string, lacing courses and copings etc, rounded or chamfered on edges type C1 1:3:6 (20 mm graded crushed stone aggregate) including necessary form work complete all as specified and directed.
Material and labour for hardcore of gauge exc 63 mm but n exc. 100 mm, of broken stone or boulder deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
Material and labor for cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) 100 mm thick as in sub base complete all as specified and directed.
Material and labour for cement concrete type B -1, 1:2:4 (using 20mm graded crushed stone aggregate) 100 mm thick as in hardstanding complete finished fair and even without using extra cement all as specified and directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' thickness of slab 100mm complete all as specified and directed.
Rough excavation n exc 1.5 m deep and getting out in hard/ dense soil complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed.
Supply and planting LXORA plant having minimum 60cm height, sampling should be grown in 30cm pot, healthy grown up with good roots system including digging of pit of size 60cm x 60cm x 60cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Vinca bicolour plant having minimum 45cm height, sampling should be grown in 25cm pot, healthy grown up with good roots system including digging of pit of size 60cm x 60cm x 60cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Acalypha plant having minimum 60cm height, sampling should be grown in 25cm pot, healthy grown up with good roots system including digging of pit of size 60cm x 60cm x 60cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Jasmin sp plant having minimum 60cm height, sampling should be grown in 25cm pot, healthy grown up with good roots system including digging of pit of size 60cm x 60cm x 60cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Bougainvillia plant having minimum 60cm height, sampling should be grown in 25cm pot, healthy grown up with good roots system including digging of pit of size 60cm x 60cm x 60cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Cassia Fistula plant having minimum 150cm height, sampling should be grown in 325mm x 325mm bag, healthy grown up with good roots system including digging of pit of size 90cm x 90cm x 90cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Crepers(Clerodendron/Thunbergia) plant having minimum 150cm height, sampling should be grown in 25cm pot, healthy grown up with good roots system including digging of pit of size 90cm x 90cm x 90cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed.
Supply and planting Ashoka Tree plant having minimum 180cm height, sampling should be grown in 225mm x 300mm bag, healthy grown up with good roots system including digging of pit of size 90cm x 90cm x 90cm in any type of soil, refilling with good approved soil mixed with decomposed cattle manure in ratio 2:1 and watering complete all as specified and directed. Notes :- for Srl Nos 42 to 49 i) The quoted rates shall deemed to be included necessary watering to plant till completion of work. ii) If any palnt dies during defect liability period of contract, the same shall be replaced with new similar plant by the contractor without any extra cost to the Government. The quoted rate shall be deemed to include said provision and nothing extra shall be admissible to the contractor on this account.
Dismantling of existing old padding concrete of any thickness of existing water proofing treatment over the RCC slab other than beams, chajjas, staircase etc by chipping of with porper tools viz chiesel and with applying reasonable force so as to avoid any damages to existing RCC roof slab complete as directed by Engr-in-Charge.
Material and labour for 40mm thick (average thickness) PCC 1:2:4 (Type B0 using 12.5 mm graded crushed stone aggregate) as in levelling/padding course on roof slab, chajjas, projections on similar surfaces existing with slope, kerbs, roundedor chamfered edges, making the surface enven and smooth without using extra cement using liquid water proffing compound as per manufacturers instructions including form work if any complete as specified and directed by Engr-in-Charge. Note:-Liquid water proofing compound will measure and paid seperately as supply only.
Material and labour for rendering 10 mm thick on green fair faces of concrete surface in cement mortar 1:4 for receive the roof finishes using water proofing compound as per manufacturers instructions. (WPC Shall be measured and paid separately as supply only) complete all as specified and directed.
Material and labour for APP based polymeric membrane minimum weighing 3.5 kg / sqm and minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 160 gms /sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 litre/sqm by forced application then applying one coat of bitumen @ 1.2 Kg / sqm and two coats of bituminous aluminium paint complete all as specified and directed. The complete roof treatement shall be consisting of as under :- (i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 litre / sqm, (ii) Laying of APP based membrane of specified thickness and weight, (iii) Applying one coat of bitumen of grade 85/25@ 1.2 Kg / sqm, (iv) Applying two coats of bituminous aluminium paint @ 100 ml/ sqm per each coat. Note:-(i) The work shall be executed through authorised applicator only as approved by GE. (ii) The contractor has to furnish guarantee for 10 years for APP membrane.
Supply only integral liquid WPC of approved make complete all as specified and directed.
Taking down cement plaster on brick or stone walls or concrete surfaces etc incld raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Material and labour for 5 mm thick plastering in cement mortar 1:3 on ceiling and finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for three coats of white wash on ceiling including preparation of new or previously untreated surface complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats distmper oil emulsion over a coat of primer over and including 3 mm thick wall care putty complete all as specified and directed.
Material and labour for complete removal of existing treatment on wall and applying two coat of exterior emulsion over a coat of primer after preparation of surfaces at any height including necessary scafolding etc complete all as specified and as directed by Engr in charge.
Material and labour for Preparation of new or previously un treated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking down Chowkhats & frames with shutters (without taking off shutters from the frames) n. exc 1.5 sq. m each complete all as specified and directed.
Supply and fix, factory made box type steel window, comprising of double rebated frame made of ERW Hollow outer profile of size 80mmx60mm of 1.25mm wall thickness of frame including side hung double shutters (i.e. one side of frame glazed shutters with sash bars and other side of frame skelton shutters without sash bars) made of ERW hollow section 40mmx20mm of 1mm wall thickness, glazed shutters divided in three panels with two Nos sash bars welded to frame of shutter and prepared to recieve sheet glasses including provision of flat iron strip of size 15mm x 3mm (02 Nos) to skelton shutters with rivetted bolt to secure wire mesh, providing hold fasts 04Nos of required size complete as per Drg No CERD//TD-485/2021 Sheet Nos 1/5 to 4/5 including a shop coat of red red oxide primer and making holes 04 Nos in brick wall/ stone wall/ concrete for each window for fixing hold fasts of size 150mmx230mmx75mm including PCC 1:2:4 type B-1 using 20mm graded stone aggregate as for hold fasts including necessary form work, complete all as specified and directed. Notes:- (i) Glass panes, wire mesh & painting shall be measured & paid separately under respective items of BOQ, (ii) Design shall be as approved from GE before fabrication and placing bulk order to the manufacturer, (iii) TD drawings are not being enclosed but these shall form part of the tender documents. The same may be seen in GE office during working hours.
Supply and fixing 4.00mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
Material and labour for 30mm thick PCC type B-0 1:2:4 using 20mm graded crushed stone aggregate finished rough surface complete all as specified and directed.
Material and labour for Screed bed 20 mm thick for laying floor finish as a bedding layer in cement mortar 1:6 complete all as specified and directed.
Material and labour for machine cut kota stone flooring 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding and polishing complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material and labour for backing coat 10mm thick cement plaster in cement mortar 1:4 on brick/concrete surfaces complete all as specified and directed by the Engineer-in-Charge.
Material and labour for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, skirting, dado etc laid bedded and pointed in any mortar complete all as specified and directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Material and labour for pressure guniting 30mm thick lath over existing RCC structure with cement mortar (1:3) incorporating with approved acryic polymer agent and 5mm thick plaster cement mortar (1:4) for finished the gunited surfaces even and fair without using extra cement including scaffolding any height from base complete all as specified and directed. Note : Acyrlic polymer/ spray set admiture shall be measured and paid seperately under relevant items of this BOQ as 'Supply only'.
Supply only sprayset admixture as approved complete all as specified and directed. Make: HBL of Fosroc or equivalent in make as specified in Appx 'B' as approved by GE.
Material and labour for design mix concrte M-25 (using 20mm graded crushed stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including form work complete all as specified and directed.
Taking down carefully point wiring (Light , fan socket or power) complete fittings such as (switchs, ceiling roses, lights, regulators, sockets etc to be measured seperately) and removing materials to store for safe custody or for reuse at site or issue under Sch of Credit and making good to the disturbed surfaces to match the existing complete all as specified and directed.
Taking down carefully DBs any type any size all as specified and removing to store for safe custody for reuse at site or issued under schdule of credit and making good to the disturbed surfaces to match with the existing complete all as specified and directed.
Taking down carefully ceiling fans / exhaust fans, sealing cable end, dismantling blades and removing fan and blades to store and making good to the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for point wiring (on surface ) in and including stove enemelled steel / ERW conduit along with fittings, ISI marked 19/20 mm dia, with 1.5 Sqmm PVC FRLS insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with cast iron/pressed steel terminal box of suitable sizes & 1.6 mm thick duly painted inner & outside by anti-corrosive paint, for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover with brass screw, cup washer and including PVC FRLS insulated & unsheathed stranded copper conductor of 1.5 Sqmm as continuous earth wire complete all as specified for the following :- a) One light point controlled by one switch.
b) One Fan point controlled by one switch.
c) One Exhaust Fan point controlled by one switch.
d) One 5 Amps socket outlet point on independent board controlled by one switch.
All as per item No.78 herein before but power point wiring with 4.0 Sqmm single core PVC FRLS insulated unsheathed cable with stranded copper conductor for one switch socket outlet, 5/15 Amps multi purpose on independent board including PVC FRLS unsheathed copper conductor of 4.0 sqmm as earth wire all as directed by Eng-in-charge.
Supply & fix Ceiling rose surface Bakelite, 65x50mm three terminals 230 Volts, AC Single phase complete all as specified and directed.
Supply & fix Switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed.
Supply & fix for switch socket combination 2 in 1, 3 pin, 5 Amp, flush type complete all as specified and directed.
Supply & fix for switch socket combination 5 in 1, 6 pin, 5A/16A flush typecomplete all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed by Engineer-in-Charge.
Supply and fix surface and wall mounted LED 20 W batten with aluminum housing & integrated electronic driver complete all accessories as per directed by Engineer-in-Charge. Make:-Havells Cat No-LUMILINEPLUSBS20WLED865SPCSS or equivalent in make as specified in appendix 'B' as approved by GE.
Material and labour for submain wiring with two runs of PVC insulated 1100 volts graded multistranded, copper coductor of size 4.0 Sqmm FRLS cable single core with earth continuity conductor cable of same description but 4.0 Sq mm drawn in ERW steel conduit all as specified.
Supply and fixing TPN distribution board factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated 4 way to be fixed flush with wall complete with all accessories all as directed by Engineer-in-Charge.
Supply and fixing ,connecting and testing MCB three pole and neutral (MCB TPN) 440 volts, of capacity 32 to 63 Amps, 10 kA C curve complete all as specified and directed by Engineer-in-Charge..
Supply and fixing, connecting and testing MCB single pole (MCB SP) 220 volts of capacity 6 to 32 Amps, 10 kA C curve complete all as specified and directed by Engineer-in-Charge.
Material and labour for Earthing in repairs with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 4mm by means of nuts, bolts, checking nuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR part-I connected to earthing test point including taking down the existing earthing plate, etc including excavation & earth work in any type of strata, watering pipe 20mm bore light grade with funnel, PCC chamber with PCC cover slab1:2:4 type B1 without GI protection pipe 20mm bore light grade, charcoal & salt etc all as specified and directed by Engr-in-Charge.
Material and labour for taking down ceiling fans / exhaust fans of any sweep /size and repair/rewinding /servicing and refixing at same place after painting of ceiling fans / exhaust fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing air termination single pointed aluminium rod of 12mm dia 300mm long including dismantling taking out old air termination complete all as specified and directed.
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including, 3 NOS, 8mm dia 25mm long hex, head screw including dismantling taking out old inspection box complete all as specified and directed.
Supply and fixing aluminium strip 25x3mm with saddle and fixing screws etc for roof conductors and down conductors above ground level fixed on walls / roof with all neccesary fixing arrangements complete all as specified and directed including dismantling taking out old aluminium strip.Note : Epoxy base insulator and PCC block only will be measured and paid seperately completel all as specified and directed.
Supply and fixing galvanised iron strip of size 32x6 mm burried in ground or "fixed on wall'' with all neccesary fixing arrangements complete all as specified and directed including dismantling taking out old galvanised iron strip.Note : 1. Epoxy base insulator only will be measured and paid separely. 2. All GI strip joints should be butt welded atleast 50 mm long complete all as specified and directed.
Material and labour epoxy base insulator suitable size 35 mm height fixed on PCC blocks / on wall on MS angle / on towers with and including nut bolts and washers etc by including dismantling taking out old insulator complete all as specified and directed.
Supply and fixing PCC block of size 150x150x150mm in PCC 1:3:6 Type C1 with 20mm graded aggregte for fixing on roof conductor / air terminal rod / GI Strip etc including necessary form work including dismantling taking out old PCC block complete all as specified and directed.
Material and labour for GI tubing light grade of size 40 mm bore for connecting to air termination rod / protection to GI strip complete ncluding Brackets for fixing complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI earth strip 32x6mm by means of GI nuts, bolts check nuts and washers earth lead protected by 40mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including testing on completion. Notes : The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways, GI funnel with GI watering pipe 20mm dia med gde, wire mesh, protection pipe 40mm dia GI pipe light gde for earth lead upto 7.50m long complete all as specified and directed. Note :- GI strip 32x6 mm beyond 7.5 mtr will be measred & paid seperately.
Supply and fixing earth pit indicator made out of MS sheetof 16SWG of size 30x20cm welded to " angle of size 25mm x 25mm x 3mm at a height 1m above ground including dismantling taking out old earth pit indicator complete all as specified and directed.
Supply and fixing inspection boxes /test point boxes 250mm x150mm x100mm made out of 16gauge MS sheet with top cover including provisioin of fixing of 2 Nos epoxy insulator with and including insulating PVC sheet for incoming and outgoing copper strip for proper insulation etc complete all as specified and directed.
Taking down Eight Zone control panel carefully by removing existing connecting cable without damaging existing UV,IR detector etc complete all as specified and directed.
Supply and fix, test and commissioning for microprocessor based intelligent control panel Eight zone with RS 485 PORT to control deluge system, connecting repeater panel including battery backup 20 hours with and including provision of battery charger 2 Nos rechargeable SMF batteries of BP 46,12 volts,40 AH/20 HR in each building complete including glands lugs and indication on cable control wiring for eight zone complete all as specified and directed by Engineer-in-Charge. Make:- Tata Honeywell / Notifier/ESIS
Supply and fix, test and commissioning for microprocessor based intelligent Repeater panel Eight zone with RS 485 PORT to control deluge system, connecting repeater panel including battery backup 20 hours with and including provision of battery charger 2 Nos rechargeable SMF batteries of BP 46,12 volts,7 AH/20 HR in each building complete including glands lugs and indication on cable control wiring for eight zone complete all as specified and directed by Engineer-in-Charge. Make:- Tata Honeywell / Notifier/ESIS
Supply,fix,test and commissioning of with weather shed type manual call points in repair, manual call point resettable type wall mounting type with and including dust and moisture proof cover and designed to rise the alarm once the glass is broken complete all as specified and directed by Engineer-in-Charge. Make:- Tata Honeywell / Notifier/ESIS
Supply,fix,test commissioning Fire Alarm hooter electronic type with and including weather shed complete all as specified and directed by Engineer-in-Charge. Make:-Alert /Khairaz or equivalent ISI marked make as approved by GE.
Supply,laying,testing and commissioning on wall, roof or floor, armoured FRLS cables from Control panel to Repeater panel of size 6 core 1.5 sqmm PVC insulated and sheathed complete all as specified and directed by Engineer-in-Charge.
Supply,laying,testing and commissioning on wall, roof or floor, armoured FRLS cables from Control panel to Repeater panel of size 2 core 1.5 sqmm PVC insulated and sheathed complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting of bituminous road / floor for laying of pipe not exceeding 1.5 meter wide and not exceeding 10cm deep including and making good with PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate, 100 mm thick finished the surface fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply and laying flexible PVC pipe of size 40 mm bore for drawing of control cable 6 core 1.5 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and laying Light Grade GI pipe of size 40 mm bore galvanised, with all fitting laid in trenches for drawing of control cable 6 core 1.5 sqmm complete all as specified and directed by Engineer-in-Charge.
Baljeet Singh Choudhari
M/S NILESH BUILDERS
R. K. Industrial Fabricators
S.K.HARAL
AJAY ENTERPRISES
sanjay m. suryawanshi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .