| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | ₹45.6 L Quoted ₹47.8 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹52.1 LRejected-Finance AT SHRI RAMADHAR YADAV WEST ABHIYANTA NAGAR BAILEY ROAD DANAPUR PATNA BIHAR 801503 | DANAPUR | PATNA | BIHAR | 801503 | ₹52.1 L | L2 | Rejected-Finance Bid is not lowest |
| 3 | L3₹52.3 LRejected-Finance 20 23 MANASKAMANA ROAD BANSBARI MORE PS ENGLISHBAZAR DT MALDA | ENGLISHBAZAR | MALDA | WEST BENGAL | 732101 | ₹52.3 L | L3 | Rejected-Finance Bid is not lowest |
| 4 | L4₹53.2 LRejected-Finance | ₹53.2 L | L4 | Rejected-Finance Bid is not lowest |
| 5 | L5₹53.6 LRejected-Finance VILL PO MANOHAR CHHAPRA MOTIPUR DISTT MUZAFFARPUR PIN 843111 | MOTIPUR | MUZAFFARPUR | BIHAR | 843111 | ₹53.6 L | L5 | Rejected-Finance Bid is not lowest |
| Sl No | Description | Qty | Unit | M/S ANAND MOHAN ENTERPRISES L5 | M/S Priya Trading Agency L7 | ANAHITAS INFOSOLUTIONS PRIVATE LIMITED L2 | RAJ AND SONS L6 | M/S SAROJ KUMAR SINGH L1 | M/s Mukesh and company L3 | VAISHNAVI CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Taking out MS / GI / CI / DI pipe any type including fittings with / without spigot and socketed end laid in trenches including removing of lead for following sizes :- Note :- Old lead shall be re used. | ||||||||||
| 1.01 | 15 mm bore. | 350 | RM | 50 ₹17,500 | 60 ₹21,000 | 60 ₹21,000 | 50 ₹17,500 | 5 ₹1,750 | 50 ₹17,500 | 62 ₹21,700 |
| 1.02 | 20 mm bore. | 330 | RM | 50 ₹16,500 | 62 ₹20,460 | 65 ₹21,450 | 60 ₹19,800 | 5 ₹1,650 | 60 ₹19,800 | 66 ₹21,780 |
| 1.03 | 25 mm bore. | 304 | RM | 55 ₹16,720 | 65 ₹19,760 | 70 ₹21,280 | 60 ₹18,240 | 5 ₹1,520 | 70 ₹21,280 | 72 ₹21,888 |
| 1.04 | 40 mm bore. | 156 | RM | 65 ₹10,140 | 70 ₹10,920 | 80 ₹12,480 | 60 ₹9,360 | 5 ₹780 | 75 ₹11,700 | 81 ₹12,636 |
| 1.05 | 50 mm bore. | 78 | RM | 65 ₹5,070 | 72 ₹5,616 | 85 ₹6,630 | 60 ₹4,680 | 5 ₹390 | 90 ₹7,020 | 85 ₹6,630 |
| 1.06 | 80 mm bore. | 70 | RM | 75 ₹5,250 | 85 ₹5,950 | 90 ₹6,300 | 80 ₹5,600 | 5 ₹350 | 95 ₹6,650 | 92 ₹6,440 |
| 1.07 | 100 mm bore. | 24 | RM | 85 ₹2,040 | 90 ₹2,160 | 95 ₹2,280 | 80 ₹1,920 | 10 ₹240 | 100 ₹2,400 | 96 ₹2,304 |
| 1.08 | 150 mm bore. | 12 | RM | 80 ₹960 | 92 ₹1,104 | 100 ₹1,200 | 80 ₹960 | 10 ₹120 | 106 ₹1,272 | 105 ₹1,260 |
| 2.00Refixing only GI steel tubing and connections in new or old position including cleaning internally and externally, any grade / make (in trenches / wall / floor / ceiling) including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of following size:- | ||||||||||
Tender Value
₹45.0 L
EMD Value
₹89,900
Closing Date
8 Jan 2026, 6:00 pmClosed
GE DANAPUR
DANAPUR CANTT
REPAIR MAINT OF CI DI PIPE LINE VARIOUS VALVES VALVE PIT CHAMBER AND ALLIED WORKS AT DANAPUR REPAIR MAINT OF VARIOUS TYPES OF PUMPS MOTOR ELECTRIC PANELS CLEANING OF OH TANK AND UG SUMP AND SWIMMING POOL AT DANAPUR AND REPAIR MAINT OF STREET LIGHT SE
2025_MES_744920_1
CA NO GE DNR T85 OF 2025 26
Open Tender
Civil Works
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE DANAPUR
₹89,900
Yes
19 Feb 2026
17 Dec 2025
15 Jan 2026
17 Dec 2025
8 Jan 2026
1 Jan 2026
WIMMING POOL AT DANAPUR & REPAIR/MAINT OF STREET LIGHT, SECURITY LIGHT, CABLES, POLES AND CONNECTED WORKS UNDER GE DANAPUR CANTT
Taking out MS / GI / CI / DI pipe any type including fittings with / without spigot and socketed end laid in trenches including removing of lead for following sizes :- Note :- Old lead shall be re used.
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore.
100 mm bore.
Refixing only GI steel tubing and connections in new or old position including cleaning internally and externally, any grade / make (in trenches / wall / floor / ceiling) including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of following size:-
Taking out MS / GI / CI / DI pipe any type including fittings with / without spigot and socketed end laid in trenches including removing of lead for following sizes :- Note :- Old lead shall be re used.
15 mm bore.
150 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore.
100 mm bore.
50 mm bore.
Taking out MS / GI / CI / DI pipe any type including fittings with / without spigot and socketed end laid in trenches including removing of lead for following sizes :- Note :- Old lead shall be re used.
15 mm bore.
150 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
Supply, laying and testing (DI) Ductile Iron pressure flanged type, class K-9 suitable for rubber gasket joints in standard working length confirming to IS-8329/2000 with inside cement mortar lining duly ISI marked laid in trenches complete all as specified and directed of following sizes : -
80 mm bore.
100 mm bore.
Supply, laying , jointing and testing GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/ floor/ all as specified and directed of following size:-
Taking out MS / GI / CI / DI pipe any type including fittings with / without spigot and socketed end laid in trenches including removing of lead for following sizes :- Note :- Old lead shall be re used.
15 mm bore.
150 mm bore.
S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe for following sizes: -
40 mm bore.
40mm bore.
80 mm bore.
M&L for run lead joint with spurn yard & head for spigot and socketed end CI pipe & fittings complete all as specified directed for following :-
150mm bore.
200mm bore.
Supply and fix cast iron flanged sluice valve of class 1.6 PN installed complete with ISI marked (IS-14846) with gun metal spindle and hand wheel all as specified and directed by EIC including taking down old unserviceable one of following size : -
80 mm bore.
M&L for run lead joint with spurn yard & head for spigot and socketed end CI pipe & fittings complete all as specified directed for following :-
150mm bore.
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe in soft / loose type of soil and getting out complete all as specified.
Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25cm thick complete all as specified and directed by EIC.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in (CM 1:6) complete all as specified & directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in copping etc including necessary form work complete all as specified and directed.
250 mm bore.
M&L for rendering 15 mm thick on fair face of brick work in CM 1:4 finished even and smooth wiyhout using extra cement complete all as specified directed.
M& L for priming painting on cement plastered surfaces of any description over 10 cm width or girth two coat complete all as specified and directed.
S&F MS chamber cover with angle iron frame , 6 mm thick MS plate, provided with lifting hooks, embedded in masonry, and finished with one coat of red oxide primer and two coats of synthetic enamel paint, complete all as specified and directed of following.
Frame Work(angle)
MS Work
Overhauling of 20 HP/10 HP/5 HP centrifugal motor of pump set of Sewage Pump by dismantling each part cleaning properly, oiling greasing with replacing bearing, bushes, oil seal, gland packing set and reassembling of pump set all as specified and directed as per existing size and making connection with proper size of lugs, nuts bolts including cleaning , scraping out old rubbed paint / rust & applying two coat of rubber synthetic paint ( first class ) by spray painting machine over a coat of primer commissioning and testing complete all as specified and directed.
S & F in repair rubber star packing of motor & pump of existing size and type including resetting alignment of the pump sets of following capacity:-
(a) 20/10/5 HP pump.
Taking out submersible pump of 62 / 72 HP capacity including motor from bore well by disconnecting all electric / water connections dismantling of motor and pump for repair including transportation from work site to workshop and back, lowering of pump set, connecting and testing complete all as specified and directed.
M&L for opening of submersible motor of 62 / 72 HP capacity and taking out the rotor from the body and cutting the burnt coils / winding, cleaning the starter slots properly by using cleaning material and re-winding / reassembling the same including replacement of parts/components complete including cleaning, scraping out old rubbed paint / rust & appling two coat of rubber synthetic paint (first class) by spray painting machine over a coat of primer of any capacity of motor complete all as specified and directed. Note:- Replacement of parts / components shall be measured and paid separately under respective item of Schedule 'A' as supply only.
M&L for Lath work including all materials as required for the following items/components of motor of 62 / 72 HP capacity complete as under :- (a) Making the strip on rotor including pressing the core of rotor and polishing the shaft. (b) Making the proper size of motor cover (housing) including welding etc. (c) Re-metaling of thrust plate and replacement of ebonite sheets complete.
Replacement of nut bolts and Washers Suitable for 62/72 HP Motor as per sample complete all as specified and directed.( Full set)
Replacement of Bushes/Shaft Sleeves Suitable for 62/72 HP Motor as per sample complete all as specified and directed.
Supply only Gland packing, Gaskets, oil seal Suitable for 62/72 HP Motor as per sample complete all as specified and directed.
Testing and Commissioning of Submersible motor of capacity 62/72 HP Including Vibration, Alignment, Leakage Check Complete all as Specified and Directed
MS sheet Primer
S&F 3 core x 25 Sqmm Copper Flat Submersible Cable (ISI marked, PVC/XLPE insulated, Suitable upto 1100V) complete all as specified and directed.
Supplying and fixing of 6" (150 mm) dia column pipe for borewell installation, heavy duty MS/ERW pipe of ISI make, minimum wall thickness 5–6 mm, length 3 m/5 m with threaded/flanged ends and suitable couplings, including welding, threading, alignment, lowering in borewell, jointing with nuts, bolts, gaskets, and painting with anti-corrosive primer and two coats of enamel paint, complete as directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps including all fixing arrangement complete all as specified and as directed.
S&F in replacement of Pressure gauge 0-150 LBS/in2 / 0 to 10 KG/cm2 ISI marked complete all as specified and directed.
S & F in repair of Start/Stop push button heavy duty type complete all as specified and directed.
M&L for replacement of Voltmeter 96 mm x 96 mm, range 0-500 Volts digital type complete all as specified and directed.
M&L for replacement of Ammeter 96 mm x 96 mm, range-0-100 Amps digital type complete all as specified and directed.
M&L for replacement Indication lamp (RYB) complete all as specified and directed.
Supply, installation, testing and commissioning of 125 Amp, 4-Pole MCCB, 415V, 36kA breaking capacity, thermal–magnetic release with adjustable settings, complete with rotary operating handle and necessary accessories, mounted in panel board as required complete all as specified and directed
Supply only steel wire rope 6mm dia (7/19 construction) suitable for highmast system including u bolt complete all as directed.
Supply, installation, testing and commissioning of 320 Amp, 4-Pole MCCB, 415V, 25kA breaking capacity, thermal–magnetic release with adjustable settings, complete with rotary operating handle and necessary accessories, mounted in panel board as required complete all as specified and directed.
Supply, installation, testing and commissioning of Single phase preventer VPS-3 complete all as specified and directed.
Supply and installation of 3-phase timer switch for automatic star-to-delta changeover in motor starting panels. Designed to control star contactor OFF and delta contactor ON after preset time delay. Suitable for 415V AC, industrial applications complete all as specified and directed.
Supply and installation of Copper Cable Lugs with 30 mm hole size, suitable for terminating copper conductors in motor control panels, distribution boards, and power circuits. The lugs shall be made of high conductivity pure copper, tinned surface, with appropriate barrel size to fit conductor size (e.g., 16 mm² to 95 mm²), and designed for proper crimping. Suitable for M30 bolt connection. Conforming to IS 8309 / Equivalent Standards complete all as specified and directed.
Supply and installation of Thermal Overload Relay, adjustable current range 60–100 A, suitable for protection of 3-phase motors against overload conditions. Wiring and connections to be done as per site requirement complete all as specified and directed.
Carry out physico-chemical, biological testing of water of bore well at different pump house i.e PH-1, PH-2, PH-3 & CDA/NCC Patna from Govt Lab/Govt Authorised Laboratory all directed and submitting the report to Eng-in-charge complete all as specified and directed. Rates quoted should be for one sample.
Taking down old unsv Street light / flood light fittings in any position of any capacity for Repair by replacement of unsv spares ( SPD / Driver / Mcpcb etc ) and re-fixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items.
S&F MCB, SP 10-32 Amps, 'C' Curve with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
Supply and installation of 16 sqmm Copper Conductor, Single Core, PVC Insulated, 600/1000V Grade Electrical Wire for motor control panel wiring. The wire shall be used for power and control circuits inside the motor panel, conforming to IS 694 standard. Proper termination with lugs and ferrules shall be provided, and wiring shall be neatly routed in cable ducts or trays as per site requirement complete all as specified and directed.
S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete, lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers, > 120 Lm/W efficacy,Operating voltage:120–270V AC, 50Hz etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, fixing to wall/pole , complete all as specified and directed.
All as per item No-48 above but 70 watts.
S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 100 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable,Operation Voltage-120–270V AC, 50Hz,System efficiency>110/120 lumens/watt, 10kv SPD etc, fixing to wall/pole complete all as specified and directed.
All as per item No-48 above but 60 watts.
All as per item No-51 above but 120 watts.
All as per item No-51 above but 150 watts.
Supply, fixing, in replacement connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed.
Supply, fixing, in replacement connecting and testing post top light fitting integral type in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X25 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with 1 coats of Cement base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
All as per item No-59 above but of size 10 Sqmm complete all as specified and directed.
All as per item No-51 above but 200 watts.
All as per item No-59 above but of size 6 Sqmm complete all as specified and directed.
S&F in replacement PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed.
Supply and fixing lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed
Dismantling LT steel tubuler pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Taking down, transport to workshop , Re-winding of electric motor 3 phase installed at high mast pole of capacity upto 2.2/3 HP and refixing of the same including necessary arrangement complete all as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.40 MB
ParticularSpecification8765.pdf
Additional Documents • 0.66 MB
BOQ_834077.xls
BOQ • 4.23 MB
Schedule.pdf
Additional Documents • 0.16 MB
Tender8965.pdf
Tender Documents • 0.52 MB
Download all tender documents and submit your bid