Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | ₹36.6 L Quoted ₹36.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹37.5 L+₹68,800.19 (1.87%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹37.5 L+₹68,800.19 (1.87%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹38.5 L+₹1.7 L (4.71%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹38.5 L+₹1.7 L (4.71%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹38.7 L+₹2.0 L (5.33%)Rejected-Finance | ₹38.7 L+₹2.0 L (5.33%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹39.1 L+₹2.3 L (6.28%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹39.1 L+₹2.3 L (6.28%) | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹36.9 L
EMD Value
₹73,760
Closing Date
17 Feb 2024, 6:00 pmClosed
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO- GARHI, PIN-182121
Special repair/replacement of Overhead line to underground cable including connected works at Krimchi Complex area under GE(Utilities) Udhampur.
2024_MES_639284_1
GE/U- /2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (UTILITIES) UDHAMPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹73,760
16 Mar 2024
27 Jan 2024
24 Feb 2024
27 Jan 2024
17 Feb 2024
10 Feb 2024
Amount
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm x3.5 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 185 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 150 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 120 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 95 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 70 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 16 Sqmm x 2 core complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but size 10 Sqmm x 2 core complete all as specified and directed by Engr-in-Charge.
(c) Panel indicating lamp neon/LED type (Red,Yellow & Blue) with lamp holders-03 Nos. (d) Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core-01 Job. (a) Incoming:- (i) MCCB 4 Pole, Ics = 100% Icu, 50 KA, 415 Volts, 315 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (b) Outgoing:- (i) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 63 Amps with thermal adjustable and fixed magnetic setting with extended terminals-03 Nos. (ii) MCCB 4 Pole, Ics = 100% Icu, 25/26KA, 415 Volts, 40 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. Note:- (a) Item retrived from site should be refixing at new location as per direction by Engr-in-Charge. (b) Cost of refixing of LT panel will be paid separately in respected item.
(c) Panel indicating lamp neon/LED type (Red,Yellow & Blue) with lamp holders-03 Nos. (d) Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core-01 Job. (a) Incoming:- (i) ACB 4 Pole, Ics = 100% Icu, 50 KA, 415 Volts, 800 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (b) Outgoing:- (i) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 630 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (ii) MCCB 4 Pole, Ics = 100% Icu, 25/26KA, 415 Volts, 315 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (iii) MCCB 4 Pole, Ics = 100% Icu, 15/16KA, 415 Volts, 40 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. Note:-(a) Item retrived from site should be refixing at new location as per direction by Engr-in-Charge. (b) Cost of refixing of LT panel will be paid separately in respected item.
(c) Panel indicating lamp neon/LED type (Red,Yellow & Blue) with lamp holders-03 Nos. (d) Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core-01 Job. (a) Incoming:- (i) MCCB 4 Pole, Ics = 100% Icu, 50 KA, 415 Volts, 500 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (b) Outgoing:- (i) MCCB 4 Pole, Ics = 100% Icu, 25/26KA, 415 Volts, 63 Amps with thermal adjustable and fixed magnetic setting with extended terminals-05 Nos. Note:-(a) Item retrived from site should be refixing at new location as per direction by Engr-in-Charge. (b) Cost of refixing of LT panel will be paid separately in respected item.
(c) Panel indicating lamp neon/LED type (Red,Yellow & Blue) with lamp holders-03 Nos. (d) Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core-01 Job. (a) Incoming:- (i) MCCB 4 Pole, Ics = 100% Icu, 50 KA, 415 Volts, 250 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (b) Outgoing:- (i) MCCB 4 Pole, Ics = 100% Icu, 25/26KA, 415 Volts, 63 Amps with thermal adjustable and fixed magnetic setting with extended terminals-10 Nos. (ii) MCCB 4 Pole, Ics = 100% Icu, 15/16KA, 415 Volts, 40 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. Note:-(a) Item retrived from site should be refixing at new location as per direction by Engr-in-Charge. (b) Cost of refixing of LT panel will be paid separately in respected item.
(c) Panel indicating lamp neon/LED type (Red,Yellow & Blue) with lamp holders-03 Nos. (d) Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core-01 Job. (a) Incoming:- (i) MCCB 4 Pole, Ics = 100% Icu, 50 KA, 415 Volts, 630 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. (b) Outgoing:- (i) MCCB 4 Pole, Ics = 100% Icu, 25/26KA, 415 Volts, 63 Amps with thermal adjustable and fixed magnetic setting with extended terminals-10 Nos. (ii) MCCB 4 Pole, Ics = 100% Icu, 15/16KA, 415 Volts, 40 Amps with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos. Note:-(a) Item retrived from site should be refixing at new location as per direction by Engr-in-Charge. (b) Cost of refixing of LT panel will be paid separately in respected item.
Supply, Installaiton, commosioning and testing Weather proof outdoor double door type bus bar chamber i.e (front & back opening), made out of 1.6 mm thick MS sheet comprising 4 Nos aluminium strip each of 300 Amps mounted on insulators with 4 No's mounting legs made out of 25mm x 25mm x 5mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in plain cement concrete M-10, type C-2 (using 40mm graded crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removing of surplus soils, complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engr-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
Material and labour for road cutting for laying of HT/LT Cables / Pipes and making good the distrubued surfaces as equal to existing road finishes including refilling the excavated material, compacting , WBM and black top carpeting with biutemen & aggregate complete all as specified & directed by Engr-in-Charge.
Supply and fixing Route indicator 750X200X200mm with slant embosed facing including earth work and grouting 600mm below ground level complete all as specified and directed by Engr-in-Charge.
Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specefied and directed by Engr-in-Charge.
S&F in replacement 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-Charge.
Dismantling of old unserviceable/ broken/jointed ACSR conductor or earth wire from poles and removing from site of work complete all as specefied and directed by Engr-in-Charge.
Taking down old unserviceable existing LT panel complete all as specefied and directed by Engr-in-Charge.
K S BUILDERS
slathia construction works
PAUL TRADERS
MOHAN LAL AND SONS
FANGALIA TRADERS
BARU ENTERPRISES
vijay kumar gupta and co
PROACH ASSOCIATES BUILDERS & ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .