| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.7 L+₹23,597 (1.44%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹17.2 L+₹76,817 (4.67%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
27 Oct 2021, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO CERTAIN BUILDINGS, PERIODICAL SERVICES, ELECTRIFICATION WORK AND SEWAGE LINE REPAIR IN 16 RR AND REPAIR/ REPLACEMENT OF SOLAR WATER HEATER, RO, GEYSER, WIRING INCLUDING ALLIED WORK AT CERTAIN UNITS IN AOR OF AGE BR-III UNDER GE 881 EWS
2021_MES_478479_1
GE/PNH-43/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹31,000
Yes
29 Nov 2021
29 Sept 2021
29 Oct 2021
29 Sept 2021
27 Oct 2021
14 Oct 2021
Amount
B&R PORTION:- Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Dismantling fillets, rails, posts, rafters, purlins etc under 40 sqcm in section complete all as specified and directed.
S&F Suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 0.5mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) & E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips, complete all as specified and directed. Make:- Everest Industries Ltd of equivalent as approved by GE.
M&L for 50mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in bed blocks, copping of pole, benching and similar work with and including necessary form work, complete all as specified and directed.
M&L for chequered colour cement concrete tiles with grey cement and pigment of size 30x30cmx 25mm thick set jointed and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 20mm thick in cm 1:6 complete all as specified and directed
M&L for glazed ceramic coloured tiles of size 450 mm x 350 mm x 7mm/ 350x 250x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Note:- Shade/Colour of tile shall be approved by the GE.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/Rectagular) area of each tile exceeding 0.06 Sqm but not exc 0.11 Sqm in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including cement screed bed 15 mm thick in cement mortar 1:4 base complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/Rectagular) area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including cement screed bed 15 mm thick in cement mortar 1:4 base complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/Rectagular) area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm in vertical surface such as skirting, dados and risers set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar 1:4 base complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified and directed.
M&L for Rendering 20mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick cement plaster rendering in CM 1:6 on fair faces of stone masnory/brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Taking down cement plaster from brick or stone walls hacking for keys & scrubbing down with water including raking of joints etc as in patches complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar 1:4 on bricks or concrete surface, surface finished even & smooth without using extra cement complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S&F 0.63mm thick galvanised corrugated mild steel sheeting with grade of Zinc coating of 275 gms/Sqm with two corrugation side lap and at least 150 mm end lap , fixed with L or J type or cranked hook bolts, in roof, walls etc, complete, all as specified and directed.
All as per item No. 19 above, but except sheeting, complete all as specified and directed.
S&F 0.80mm thick plain galvanised mild steel sheeting with 275 gm/sqm Zinc coating as in ridge , hips, valley gutters, drip and straight flashingfixed with L or J type or cranked hook bolts, in roof etc., complete, all as specified and directed.
M&L for preparation of new wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of new wall surfaces and applying three coats of white wash on wall complete all as specified and directed.
M&L for preparation of new plaster surfaces of wall and applying two coats of OBD over a coat of 1mm thick wall putty complete all as specified and directed.
S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
S&F Mild steel work as in wind ties for roof including securing bolts, including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-250 Gde E-165 complete all as specified and directed.
Taking down chowkhat or frame not exc 1.5 Sqm each with shutters (without taking of shutter from the frames) complete all as specified and directed.
Taking down chowkhat or frame exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking of shutter from the frames) complete all as specified and directed.
Taking down shutters of any description, exceeding 1.0 Sqm but not exceeding 2 sqm each, from chowkhats, complete all as specified and directed.
Taking down shutters of any description, not exceeding 1.0 Sqm each, from chowkhats, complete all as specified and directed.
M&L for 35mm thick 2nd class hardwood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered paticle board medium density, wood patilcle board with commercial face veneers complete all as specified and directed.
M&L for 30mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, section 8, clause 8.24 (a) complete all as specified and directed.
M&L for preparing of new or previously untreated surfaces of wood of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F Solid pvc door frame of size 50mmx47mm made out of 5mm plain colour pvc sheet reinforced with ms square tube suppling and fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick(Stiles) consisting of frame made out of MS tubes for top and bottom rails. MS frames shall be covered with heat moulded plain coloured PVC,C, channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame with 3 Nos stainless steel hinge 100 mm size, welded/sealed to the stiles rails with suitable PVC sheet beading and jointed together with solvent cement. S&F in the frame as per manufacturer's instructions complete all as specified and directed.
S&F 30mm thick 2nd classhard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc divided into square (with sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b) supplied and fitted to chowkats complete, all as specified and directed.
S&F sheet glass pane ordinary quality & glazing with oil putty 3mm thick not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F Mild steel butt hinges, medium weight, cold rolled,75mm long complete all as specified and directed.
S&F Aluminium anodised, barrel tower bolts of extruded section of size 100mm complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F Butt hinges 100 mm long, medium weight, cold rolled mild steel, complete all as specified and directed.
S&F aluminium anodised,barrel tower bolt if extruded section 150mm long complete fixed with steel screws complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy complete all as specified and directed.
S&F Aluminium, anodised, handles 150 mm of extruded section complete all as specified and directed.
S&F aluminium, anodised, handles 100 mm of extruded section complete all as specified and directed.
S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beading complete all as specified and directed.
S&F 300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repair gratings 125mm dia with waste hole of PTMT complete all as specified and directed.
M&L for Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Taking up or down 15mm bore steel tubing & connection including cleaning for or removal from site 15mm complete all as specified and directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F GI tubing medium grade 15mm dia with all fittings, cutting, threading and fixing to walls,ceiling or in floors complete all as specified and directed.
M&L for Plain cement Concrete 1:3:6 type-B1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed.
S&F in repair MS powder coated tubular curtain rod fancy type of 25mm dia, complete all as specified and directed.
S&F in repair 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe complete all as specified and directed.
S&F in repairs 15 mm dia Bib taps, Fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make: Jaguar Cat No QQT-CHR-7037 or equivalent of Make as specified in PS.
S&F MS powder coated decorative type bracket, end ball, rounded block, bracket (coated with brown/cherry/golden colour) suitable for 25mm dia curtain rod of approved pattern and shade fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and directed.
S&F in repair 15 mm dia anglular stop cock, Fancy type, with wall flange, screwed for iron pipe complete all as specified and directed . Make:- Jaguar Cat No FLR-CHR-5053N or equivalent of Make as specified in PS.
M&L for 12mm thick both side prelaminated particle board, medium density fixed with screw to frame work in cup board shutters, partitions, shelves etc complete all as secified and directed.
Cleaning / disinfecting of PVC / RCC water storage tank of any capacity with disinfecting chemicals (Chlorine) properly with water thoroughly flushed out, complete all as specified and directed.
M&L for Preparation of old plastered/ un-plastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified and directed.
Complete removal of existing treatement and applying two coats of white wash on wall, complete all as specified and directed.
All as per item No. 62 above but on ceiling, complete all as specified and directed.
All as per item No-62 above but applying one coat of oil bound distemper white or any tint, complete all as specified and directed.
Complete removal of existing treatement from wall plaster and applying two coats of oil bound distemper white or any tint, complete all as specified and directed.
All as per item No-62 above but applying one coat of cement base paint on wall and AC sheet roof surfaces, complete all as specified and directed.
S&F in repair High or low level PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
S&F flush pipe/waste pipe of polyethylene of low or high density of PVC, 32mm dia complete all as specified and directed.
S&F in repair wash basin, Vitreous China (flat back or angle back type) of size 580 x 450mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S&F in repair for vitreous China bowl urinal (back or cornerwall type) complete including providing & fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with & including 60mm long brass screw, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe and waste pipe, (Ist quality) with flat back of size 465x355x265mm white with grating and unions for discharge pipe complete all as specified and directed.
S&F in repair, Vitreous china squatting pan of pattern, long pan, 'Orissa pattern', size 580 x 440 mm white with integral foot rests (excl flushing cistern and flush pipe) but including provision of lime concrete complete all as specified and directed.
Complete removal of existing treatement from wall plaster and applying two coats of cement base paint, complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint in camouflage pattern/single shade, complete all as specified and directed.
M&L for Preparation of old painted wooden or wood based surfaces of any description not otherwise described, over 10cm width or girth including knotting and stopping as required and applying one coat of synthetic enamel paint, complete all as specified and directed.
S&F PVC connection 450mm long 15mm dia complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in floors or fixed to walls complete all as specified and directed.
M&L for one coat of 3mm thick wall care putty on walls complete all as specified and directed.
Writing letters or figures (Block, Roman, Italic or Indian) n. exc 30cm high with synthetic enamel paint including oblitering old writing of any description to match existing work, complete all as specified and directed.
S&F in repair 75mm bore PVC soil waste and vent pipe single socketed in any length with rubber ring joints laid in floor or fixed to wall complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, capacity in 500 Ltrs including dismantling existing water tank and removing to store complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as spd in SSR Pt-I, capacity in 1000 Ltrs including dismantling existing water tank and removing to store complete all as specified and directed.
S&F in repairs 20 mm bore, Ball brass valves, high pressure, with polythene float and fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed.
M&L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 (Except stone), complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones & dressing of face beds and joints, with max.depression on face from straight edge held against the dressed surface n exc.20mm in lime or sand stone, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Cleaning of under ground sewage lines of 100mm/150 mm bore including manholes, CI stacks.gully traps etc. by means of cleaning by roding from manholes to manholes till the cleared/cleaned water running under sewage line and flushing after cleaning, taking out sludge collected in manholes, removing & depositing the same outside the periphery of defence land in the pit at a minimum distance of 50 m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes including taking off and re-fxing cover the manhole pitt, complete, all as directed. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Opening of cover (of any description and size) of septic tanks and soakage wells/pits, de-sluding / de-watering contaminated with fine waste materials ( liquid sludge) alongwith solid waste from septic tank and soakage wells/pits of any capacity/depth by mechanical pumping (Truck mounted mechanical machine) / manually making it fully functional to to entire satisfaction of Engineer-in- charge and and removing & depositing the sludge outside the periphery of defence land at a minimum distance of 50 m from nearby living accn and burring in borrow pits including covering with fresh mud and refixing the cover after cleaning / removing the liquid waste material of septic tanks / soakage wells / pits including cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces all as directed by Engr-in-Charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Cleaning of blockage of Water Closet (Indian or European), trap & pipe line upto first manhole manually by Roding and making it fully functional by flushing with water to entire satisfaction of Enginerr-in-charge including removing the deposited sludge/solid/liquid material, outside MD land and burring in borrow pits including covering with fresh mud, complete all as specified and directed by Engineer-in-charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
E&M PORTION Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv sub main wiring including earth continuity any type/ size with surface casing/ caping/ TW batten/ PVC conduit surface or recess etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light point controlled by one way switch 6 Amp complete all as specified and directed.
One fan/ exhaust fan point controlled by two way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 97 above but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire complete all as specified and directed. Make of wiring wire against item No- 97 to 98: Havells/RR Kabel/Finolex
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Ceiling rose, 3 phase PVC/poly carbonate, insulated body, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Tube light fitting box type suitable for LED 20W tube rod made out of ultra bright, glass shell, glare free, wide angle, single side connection retofit LED tube with G13 lamp holders complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting including 20LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LHFXCEP1TNNW020 for batten fittings or Equivalent cat part of make:-Wipro / Crompton / Bajaj Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair LED street light fittings 60W made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with hosing with all accessories pre wired with and including 40mm dia GI pipe bracket of 1.2 mtr made to shape as required fixed on wall or pole with FI clamp of required shap & 40x6mm siize, nut, bolts, washers and making connection with three core copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-ENDURAPEARLNEOSL60WLED757PASYTOPC or Equivalent cat part of Make specified in PS
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 10 Sqmm including taking down existing old service connection, complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 16 Sqmm including taking down existing old service connection, complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 4sqmm, 1 wire of 4 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, complete all as specified and directed.
M&L for complete servicing and repair of RO Plant of any capacity, servicing and cleaning of all accessories and re-fixing in the same in position, testing complete all as specified and directed by Engr-in-Charge. Noe:- Unsv accessories will be measured and paid seperately under respective items of Sch
Supply only micron cartridge filter sponge 4" x 20" of 4 micron suitable for existing RO plant complete all as specified and directed.
Supply only micron cartridge filter sponge 2" x 10" of 4 miron suitable for existing RO plant complete all as specified and directed.
Supply only RO Membrane conceal 100 GLD suitable for existing RO plant complete all as specified and directed.
Supply only RO Membrane conceal 400 GLD suitable for existing RO plant complete all as specified and directed.
M&L for excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m depth for taking up or laying pipe in soft /loose soil and getting out complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and ramming in layers not exceeding 25 cm without damaginlg pipes specials/CI specials, fittings complete all as specified and directed.
Removing of surplus soll not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 m above the strating point complete all as specified and directed.
S & F in repair steel water tubing galvanised ,medium grade with all fittings and fixed complete to laid in trench/ walls, in old/new situation complete all as specified and directed for bore of pipe of following sizes: -
20 mm dia
25 mm dia
40 mm dia
All as per item No 122 above but laid in trench of following bore of pipe:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
S & F in repair gate / globe valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed for bore of following size : -
20 mm bore.
25 mm bore.
40 mm bore
50 mm bore
M&L for complete servicing and repair of solar water heating system of any capacity, servicing and cleaning of all accessories and re-fixing in the same in position, testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch
S&F solar water heater collector FPC type screw less Technology suitable for existing solar water heating system, ISI marked complete all as specified and as directed. Make Recold or equivalent as approved By GE.
S&F solar collector glass suitable for existing solar water heating system complete all as specified and as directed.
Supply only Glycol for solar water heating system complete all as specified and as directed.
Repair to existing solar collector with copper brazing complete all as specified and as directed.
S&F in repair heating element of capacity 3 KW, ISI marked suitable for existing solar water heating system complete all as specified and as directed.
S&F in repair make up tank 5 Ltr capacity for existing solar water heating system complete all as specified and as directed.
S&F gasket and end joints suitable for existing solar water heating system complete all as specified and as directed.
M&L sheet glass pane ordinary quality & glazing with oil putty or wooden beads, 3mm thick not exceeding 0.50 sqm in each pane complete all as specified and directed.
ABINASHI ENTERPRISES
MS SHAM ARMYSTORE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .