Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC RATES QUOTED ARE REASONABLE | |
| 2 | L2₹26.0 L+₹1.1 L (4.33%)Rejected-Finance | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 3 | L3₹26.7 L+₹1.8 L (7.29%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 4 | L4₹27.2 L+₹2.3 L (9.10%)Rejected-Finance | L4 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 5 | L5₹28.0 L+₹3.1 L (12.3%)Rejected-Finance 10 67 1 CHINNAMUSHIDIWADA PENDURTHI VISAKHAPATNAM ANDHRA PRADESH 530051 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530051 | L5 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
10 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE PUDUKKOTTAI ROAD THANJAVUR
REPAIR AND REPLACEMENT OF LT UNDERGROUND CABLE AND CONNECTED WORKS AT AIRFORCE STATION THANJAVUR.
2021_MES_420997_2
8794/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
THANJAVUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹80,000
Yes
17 Aug 2021
29 May 2021
11 Jun 2021
29 May 2021
10 Jun 2021
5 Jun 2021
Amount
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories including taking down old unserviceable cable. Make: Havell’s / Polycab / Plaza)
All as per Item No 1 here-in-before but 16 sqmm 2 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 16 sqmm 4 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 35 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 50 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 95 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 120 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 150 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 185 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 240 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 300 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
All as per Item No 1 here-in-before but 400 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza)
Fixing/laying in replacement 80 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laying in trench or pole / wall for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/Prakash Surya)
Fixing/laying in replacement 50 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laying in trench or pole / wall for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/Prakash Surya)
Fxing/laying in replacement 40 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laying in trench or pole / wall for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/Prakash Surya)
Replacement of alluminium cable thimbles / line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 400 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells
All as per Item No.16 above but 300 Sqmm.
All as per Item No.16 above but 240 Sqmm.
All as per Item No.16 above but 185 Sqmm.
All as per Item No.16 above but 150 Sqmm.
All as per Item No.16 above but 120 Sqmm.
All as per Item No.16 above but 95 Sqmm.
All as per Item No.16 above but 50 Sqmm.
All as per Item No.16 above but 35 Sqmm.
All as per Item No.16 above but 25 Sqmm.
All as per Item No.16 above but 16 Sqmm.
All as per Item No.16 above but 10 Sqmm.
Supply and fixing in repair cable glands 10 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 16 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 25 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 35 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 50 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 95 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 120 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 150 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 185 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 240 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 300 sqmm complete all as directed by Engr In Charge.
Supply and fixing in repair cable glands 400 sqmm complete all as directed by Engr In Charge.
Supply and fixing in replacement LT heat shrink straight through jointing kit suitable for 6 to 16 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge.
Supply and and fixing in replacement LT heat shrink straight through jointing kit suitable for 25 to 50 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge.
Supply and and fixing in replacement LT heat shrink straight through jointing kit suitable for 70 to 150 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge.
Supply and and fixing in replacement LT heat shrink straight through jointing kit suitable for 185 to 300 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed. Note :- Mechanical excavation is not allowed in this Stn only manual excavation allowed.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite partricles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning.
Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .