Loading…
Loading…
Tender Value
₹89.8 L
EMD Value
₹90,000
Closing Date
7 Jul 2026, 5:30 pm
Similar tender results from the same govt authority in the past 3 years.
MR Kanshi Prakash Paikra
KONDAGAON
CONSTRUCTION OF SPECIALIZED ADOPTION AGENCY AND CHILD HELP LINE AT KANKER, DISTRICT KANKER (C.G.)
193797
NIT LETTER NO. 430 DHC JAGDALPUR
RESTRICTED TENDER
WORKS
12 days
KONDAGAON
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Chhattisgarh Housing Board (CGHB)
WORKS
MR Kanshi Prakash Paikra
RESTRICTED TENDER
PERCENTAGE
A B C D
KONDAGAON
TENDER SECTION
EXECUTIVE ENGINEER
120
12
No
0
193797
7 Jul, 2026 5:30:29 PM IST
9 Jul, 2026 11:00:00 AM IST
19 Jun, 2026 5:30:05 PM IST
NIT LETTER NO. 430 DHC JAGDALPUR
CONSTRUCTION OF SPECIALIZED ADOPTION AGENCY AND CHILD HELP LINE AT KANKER, DISTRICT KANKER (C.G.)
90000.00 INR
Demand Draft (OFFLINE)
8978000.00
2
8 Jul, 2026 5:30:52 PM IST
8978000
AS PER NIT
AS PER NIT
AS PER NIT
10000.00 INR
18d 0h 59m
6 documents required · 6 mandatory
₹10,000
₹90,000
19 Jun 2026
19 Jun 2026
9 Jul 2026
19 Jun 2026
7 Jul 2026
19 Jun 2026
8 Jul 2026
SCHEDULE OF RATE FOR INTERNAL ELECTRIFICATION WORK FOR LIBRARY BUILDING (GROUND FLOOR & FIRST FLOOR), KANKER DIST- KANKER (C.G.)
S.N. SOR Item No. Particulars of Item Unit Rate Rate in Word
01 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
1.7.1 Short Point Point 235.00 Two Hundred Thirty Five Only
1.7.2 Medium Point Point 374.00 Three Hundred Seventy Four Only
1.7.3 Long Point Point 518.00 Five Hundred Eighteen Only
02 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Myline)/ Havells (Verona) (ISI) Point 191.00 One Hundred Ninty One Only
03 1.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
1.10.2 Medium Point Point 582.00 Five Hundred Eighty Two Only
1.10.3 Long Point Point 814.00 Eight Hundred Fourteen Only
1.10.4 Extra Long Point- 1 Point 1149.00 One Thousand One Hundred Fourty Nine Only
04 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:-PVC Polycab/Precision/Saraswati Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
1.11.2 Medium Point Point 831.00 Eight Hundred Thirty One Only
1.11.3 Long Point Point 1191.00 One Thousand One Hundred Ninty One Only
1.11.4 Extra Long Point I Point 1594.00 One Thousand Five Hundred Ninty Four Only
1.11.5 Extra Long Point II Point 2042.00 Two Thousand Fourty Two Only
05 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe- Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI)
1.13.2 3 X 2.5 sq. mm in 20mm conduit Mtr 98.00 Ninty Eight Only
1.13.3 6 X 2.5 sq. mm in 25mm conduit Mtr 151.00 One Hundred Fifty One Only
1.13.4 9 X 2.5 sq. mm in 32mm conduit Mtr 210.00 Two Hundred Ten Only
1.13.14 6 X 10 sq. mm in 40mm conduit Mtr 454.00 Four Hundred Fifty Four Only
06 1.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) Make:- PVC Pipe- Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI)
1.15.2 25 mm Mtr 46.00 Fouty Six Only
07 3.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) Make:- Wire- Polycab/Havells/RR Kable (ISI)
3.11.1 1 x 1.5 sq. mm Mtr 13.00 Thirteen Only
08 3.12 Supplying and drawing following pair 0.5 mm FRLS PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification and IS: 694 (2010) Make:- Wire- Polycab/Havells/RR Kable (ISI)
3.12.2 2 Pair Metre 10.00 Ten Only
09 3.13 Supplying and drawing following grade co-axial TV wire FRLS PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/PVC conduit as per specification and IS: 694 (2010) Make:- Wire- Polycab/Havells/RR Kable (ISI)
3.13.1 RG-6 grade Mtr 12.00 Twelve Only
10 4.4 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. Make:- Wire- Legrand/Havell (ISI)
4.4.1 75mmX75mm (1/2 Module) Each 73.00 Seventy Three Only
11 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Make:- Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds Each 196.00 One Hundred Ninty Six Only
5.4.11 Plug Top (Duluxe Type) 3 Pin 16 Amps (For Power plug). Each 75.00 Seventy Five Only
5.4.15 Telephone Socket outlet Each 62.00 Sixty Two Only
5.4.16 T.V. antenna socket outlet Each 65.00 Sixty Five Only
5.4.18 25/32 amp A.C. Starter switch Each 217.00 Two Hundred Seventy Only
12 5.6 Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification. Make:- Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI) Each 720.00 Seven Hundred Twenty Only
13 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. Each 37.00 Thirty Seven Only
14 6.1 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required.P.F. should be greater than 0.9, with BEE Starrating from 1 star and above, IS:374:2019 including all amendments. Make:- Usha/Havells/Crompton/Bajaj/Orient (ISI)
6.1.3 1200 mm sweep Each 1497.00 One Thousand Four Hundred Ninty Seven Only
15 6.8 Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 Make:- Usha/Havells/Crompton/Bajaj/Orient (ISI)
6.8.2 300 mm sweep Each 1120.00 One Thousand One Hundred Twenty Only
16 6.11 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification.
6.11.2 60 cm long Each 35.00 Thirty Five Only
17 6.12 Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of celing fan) Each 49.00 Fourty Nine Only
18 6.16 Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. Make:- Havells/Wipro/Philips (ISI)
6.16.1 24 watt, size 300 x 300mm Each 1566.00 One Hundred Five Hundred Sixty Six Only
19 6.17 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. Make:- Havells/Wipro/Philips (ISI)
6.17.4 9 Watt Each 126.00 One Hundred Twenty Six Only
20 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/infalse ceiling, including connection, earthing etc complete as per specification and furnishing 5 Yrs Warranty certificate from manufacturer. IP20 P.F. should be greater than 0.9 LED chipe fficacy ratio ≥100 lumens/watt. Make:- Havells/Wipro/Philips (ISI)
6.19.3 18/20 watt {4feet} Each 390.00 Three Hundred Ninty Only
21 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. Make:- Havells/Wipro/Philips (ISI)
6.28.6 45 watt Each 2407.00 Two Thousand Four Hundred Seven Only
22 7.17 Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). Make:- Wire- Polycab/Havells/RR Kable (ISI)
7.17.1 10 sqmm (32 amp) Each 67.00 Sexty Seven Only
23 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. (Only face area is to be measured)
7.19.2 Above 300 mm and upto 450 mm deep sqm 6638.00 Six Thousand Six Hundred Thirty Eight Only
24 7.20 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as required.
7.20.2 200 amp (30x5mm) Mtr. 800.00 Eight Hundred Only
25 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. Make :- Legrand/ Havells (ISI)
9.1.1 3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA Each 1309.00 One Thousand Three Hundred Nine Only
9.1.26 4 pole MCCB, 160A, Adjustable Thermal - Magnetic Release, 35KA Each 7939.00 Seven Thousand Nine Hundred Thirty Nine Only
26 9.4 Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) Make :- Legrand/ Havells (ISI)
9.4.5 6 way Double door Each 1798.00 One Thousand Seven Hundred Ninty Eight Only
27 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Make :- Legrand/ Havells (ISI)
9.11.2 6 amps to 32 amps Each 130.00 One Hundred Thity Only
28 9.12 Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Make :- Legrand/ Havells (ISI)
9.12.3 40 amps Each 569.00 Five Hundred Sixty Nine Only
29 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Make :- Legrand/ Havells (ISI)
9.16.5 63 amps Each 1161.00 One Thousand One Hundred Sixty One
30 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.15.3 200/5 amps Each 306.00 Three Hundred Six Only
31 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 83.00 Eighty Three Only
32 10.19 Providing and fixing penal mounting following rating digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.19.2 0-200 amps Each 860.00 Eight Hundred Sixty Only
33 10.20 Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.20.2 Digital type Each 736.00 Seven Hundred Thirty Six Only
34 10.21 Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.21.1 For voltmeter Each 167.00 One Hundred Sixty Seven Only
10.21.2 For ammeter Each 183.00 One Hundred Eighty Three Only
35 12.16 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as per specification. Make:- Legrand / Havells (ISI) Metre 101.00 One Hundred One Only
36 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification:
12.19.2 With 2 metre long GI Pipes and 25 kg back filling compound. Each 7253.00 Seven Thousand Two Hundred Fifty Three Only
37 14.1 Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. Make:- Kissan/Supreme/ Finolex
14.1.4 120 mm outer dia and 103.5 mm Inner dia Metre 223.00 Two Hundred Twenty Three Only
38 15.3 Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/HUME/ STONEWARE/ METAL/HDPE pipe as perspecification, IS:9537 (2000,Part5) Make:- Polycab/Havells/KEI (ISI)
15.3.14 3.5 x 70 sq. mm. Metre 219.00 Two Hundred Ninteen Only
39 15.23 Supplying and making end termination with brass compression gland and aluminum lugs forfollowing size armoured aluminum conductor power cable of 1.1 KV grade as per specification..
15.23.15 3½ X 70 sq. mm (35 mm) Each 176.00 One Hundred Seventy Six Only
40 20.6 Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification. kg 68.00 Sixty Eight Only
41 26.17 Supply and erecting following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete.
26.17.6 CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 3Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 34B. Complete with Hose Assembly and horn, locking arrangement, operation manual, bracket with two screw and sleeve Each 5633.00 Five Thousand Six Hundred Thirty Three Only
SCHEDULE OF RATE FOR INTERNAL ELECTRIFICATION WORK FOR SPECIALIZED ADOPTION AGENCY & CHILD LINE BUILDING, AT KANKER DIST. KANKER (C.G.)
S.N. SOR Item No. Particulars of Item Unit Rate Rate in Word
01 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
1.7.1 Short Point Point 235.00 Two Hundred Thirty Five Only
1.7.2 Medium Point Point 374.00 Three Hundred Seventy Four Only
1.7.3 Long Point Point 518.00 Five Hundred Eighteen Only
02 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI) Point 370.00 Three Hundred Seventy Only
03 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Myline)/ Havells (Verona) (ISI) Point 191.00 One Hundred Ninty One Only
04 1.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
1.10.2 Medium Point Point 582.00 Five Hundred Eighty Two Only
1.10.3 Long Point Point 814.00 Eight Hundred Fourteen Only
05 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:-PVC Polycab/Precision/Saraswati Wire- Polycab/Havells/RR Kable (ISI) Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
1.11.3 Long Point Point 1191.00 One Thousand One Hundred Ninty One Only
1.11.4 Extra Long Point I Point 1594.00 One Thousand Five Hundred Ninty Four Only
06 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Make:- PVC Pipe- Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI)
1.13.2 3 X 2.5 sq. mm in 20mm conduit Mtr 98.00 Ninty Eight Only
1.13.3 6 X 2.5 sq. mm in 25mm conduit Mtr 151.00 One Hundred Fifty One Only
1.13.4 9 X 2.5 sq. mm in 32mm conduit Mtr 210.00 Two Hundred Ten Only
1.13.6 3 X 4 sq. mm in 25mm conduit Metre 128.00 One Hundred Twenty Eight Only
1.13.7 3 X 6 sq. mm in 25mm conduit Metre 161.00 One Hundred Sixty One Only
1.13.13 6 X 6 sq. mm in 32mm conduit Mtr 275.00 Two Hundred Seventy Five Only
07 1.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) Make:- PVC Pipe- Polycab/Precision/Saraswati (ISI) Wire- Polycab/Havells/RR Kable (ISI)
1.15.2 25 mm Mtr 46.00 Fouty Six Only
08 3.13 Supplying and drawing following grade co-axial TV wire FRLS PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/PVC conduit as per specification and IS: 694 (2010) Make:- Wire- Polycab/Havells/RR Kable (ISI)
3.13.1 RG-6 grade Mtr 12.00 Twelve Only
09 3.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) Make:- Wire- Polycab/Havells/RR Kable (ISI)
3.11.1 1 x 1.5 sq. mm Mtr 13.00 Thirteen Only
10 4.4 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. Make:- Wire- Legrand/Havells (ISI)
4.4.1 75mmX75mm (1/2 Module) Each 73.00 Seventy Three Only
11 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Make:- Switch Socket & accessories- Legrand (Mylinc)/ Havells (Verona) (ISI)
5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds Each 196.00 One Hundred Ninty Six Only
5.4.16 T.V. antenna socket outlet Each 65.00 Sixty Five Only
5.4.18 25/32 amp A.C. Starter switch Each 217.00 Two Hundred Seventy Only
12 5.7 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. Make:- Havells/Cona/Polycab/Vinay (ISI)
5.7.2 Deluxe Each 95.00 Ninty Five Only
13 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. Each 37.00 Thirty Seven Only
14 6.1 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required.P.F. should be greater than 0.9, with BEE Starrating from 1 star and above, IS:374:2019 including all amendments. Make:- Usha/Havells/Crompton/Bajaj/Orient (ISI)
6.1.3 1200 mm sweep Each 1497.00 One Thousand Four Hundred Ninty Seven Only
15 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 Make:- Usha/Havells/Crompton/Bajaj/Orient (ISI)
6.6.1 300 mm sweep Each 2158.00 Two Thousand One Hundred Fifty Eight Only
16 6.8 Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 Make:- Usha/Havells/Crompton/Bajaj/Orient (ISI)
6.8.2 300 mm sweep Each 1120.00 One Thousand One Hundred Twenty Only
17 6.12 Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of celing fan) Each 49.00 Fourty Nine Only
18 6.17 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. Make:- Havells/Wipro/Philips (ISI)
6.17.4 9 Watt Each 126.00 One Hundred Twenty Six Only
19 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/infalse ceiling, including connection, earthing etc complete as per specification and furnishing 5 Yrs Warranty certificate from manufacturer. IP20 P.F. should be greater than 0.9 LED chipe fficacy ratio ≥100 lumens/watt. Make:- Havells/Wipro/Philips (ISI)
6.19.3 18/20 watt {4feet} Each 390.00 Three Hundred Ninty Only
20 6.22 Supplying, installation, testing and commissioning of following 230/250 volts LED BOLLARD fitting cool white/warm white {Colour Temperature 3000/4000/5600/6000 K} with electronic driver, heat sink, capacitor and all other accessories on existing foundation/ pole bracket, including connection, earthing etc complete as per specification. P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. Make:- Havells/Wipro/Philips (ISI)
6.22.1 9 watt Each 3186.00 Three Thousand One Hundred Eighty Six Only
21 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. Make:- Havells/Wipro/Philips (ISI)
6.28.6 45 watt Each 2407.00 Two Thousand Four Hundred Seven Only
22 7.17 Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). Make:- Wire- Polycab/Havells/RR Kable (ISI)
7.17.1 10 sqmm (32 amp) Each 67.00 Sexty Seven Only
23 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. (Only face area is to be measured)
7.19.2 Above 300 mm and upto 450 mm deep sqm 6638.00 Six Thousand Six Hundred Thirty Eight Only
24 7.20 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as required.
7.20.1 100 amp (20x5mm) Mtr. 633.00 Six Hundred Thirty Three Only
7.20.2 200 amp (30x5mm) Mtr. 800.00 Eight Hundred Only
25 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. Make :- Legrand/ Havells (ISI)
9.1.1 3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA Each 1309.00 One Thousand Three Hundred Nine Only
9.1.24 4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA Each 5626.00 Five Thousand Six Hundred Twenty Six Only
26 9.2 Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) Make :- Legrand/ Havells (ISI)
9.2.5 4 way, Double door Each 692.00 Six Hundred Ninty Two Only
27 9.4 Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) Make :- Legrand/ Havells (ISI)
9.4.5 6 way Double door Each 1798.00 One Thousand Seven Hundred Ninty Eight Only
28 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Make :- Legrand/ Havells (ISI)
9.11.2 6 amps to 32 amps Each 130.00 One Hundred Thity Only
29 9.12 Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Make :- Legrand/ Havells (ISI)
9.12.3 40 amps Each 569.00 Five Hundred Sixty Nine Only
9.12.5 63 amps Each 567.00 Five Hundred Sixty Seven Only
30 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Make :- Legrand/ Havells (ISI)
9.16.5 63 amps Each 1161.00 One Thousand One Hundred Sixty One
31 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.15.2 100/5 amps Each 308.00 Three Hundred Eight Only
32 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 83.00 Eighty Three Only
33 10.18 Providing and fixing penal mounting following rating digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.18.2 0-100 amps Each 328.00 Three Hundred Twenty Eight Only
34 10.20 Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.20.2 Digital type Each 736.00 Seven Hundred Thirty Six Only
35 10.21 Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification.
10.21.1 For voltmeter Each 167.00 One Hundred Sixty Seven Only
10.21.2 For ammeter Each 183.00 One Hundred Eighty Three Only
36 12.13 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. Metre 83.00 Eight Hundred Three Only
37 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification:
12.19.2 With 2 metre long GI Pipes and 25 kg back filling compound. Each 7253.00 Seven Thousand Two Hundred Fifty Three Only
38 14.2 Supplying and laying HDPE pipe of 4kg/cum in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. Make :- Finolex/Supreme/Kissan (ISI)
14.2.3 90 mm outer dia Metre 216.00 Two Hundred Sixteen Only
39 15.3 Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/HUME/ STONEWARE/ METAL/HDPE pipe as perspecification, IS:9537 (2000,Part5) Make:- Polycab/Havells/KEI (ISI)
15.3.11 3.5 x 25 sq. mm. Metre 103.00 One Hundred Three Only
15.3.12 3.5 x 35 sq. mm. Metre 118.00 One Hundred Eighteen Only
40 15.23 Supplying and making end termination with brass compression gland and aluminum lugs forfollowing size armoured aluminum conductor power cable of 1.1 KV grade as per specification..
15.23.12 3½ X 25 sq. mm (25 mm) Each 92.00 Ninty Two Only
15.23.13 3½ X 35 sq. mm (28 mm) Each 135.00 One Hundred Thirty Five Only
41 20.6 Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification. kg 68.00 Sixty Eight Only
42 26.17 Supply and erecting following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete.
26.17.5 CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve Each 7253.00 Seven Thousand Two Hundred Fifty Three Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.09 MB
3367014512791951949_193797_NIT Form A (SAA) FINAL.doc
NIT • 0.26 MB
4069714726765905564_193797_CIRCULER 19.doc
NIT • 0.19 MB
5738670037550851818_193797_CURCULAR 2025 NEW.pdf
NIT • 6.47 MB
384491379920172981_193797_MAKE APPROVAL AND NEW GST.pdf
NIT • 3.22 MB
8205071283227479059_193797_SAA CHILDLINE SCHDULE OF ITEAM.pdf
NIT • 0.76 MB
4643027775641280843_193797_BUILDING PLAN SAA FINAL.pdf
NIT • 0.85 MB
7434546508527655306_193797_add.jpg
NIT • 0.07 MB
2877072223692806209_193797_Schedule of RATE ELE SAA.xlsx
BOQ • 0.08 MB
Download all tender documents and submit your bid