Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹23.4 L+₹3.1 L (15.3%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Dec 2019, 6:00 pmClosed
GE AF ADM AREA MAHARAJPUR
AIR FORCE STN. MAHARAJPUR
REPAIR REPLACEMENT OF LT CABLE STREET LIGHTS TIMERS AND CONNECTED WORKS AT AF STATION MAHARAJPUR
2019_MES_297226_1
8899/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AIR FORCE STN. MAHARAJPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF ADM AREA MAHARAJPUR
₹40,000
Yes
13 Jan 2020
13 Nov 2019
20 Dec 2019
13 Nov 2019
19 Dec 2019
27 Nov 2019
13 Nov 2019 - 23 Nov 2019
Amount
Labour only for checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning acrylic/glass cover connecting to electric supply and its testing on installation etc complete all as specified and directed.
NOTES FOR SCH `A’ ITEM NO 1:- (i) Fixing charges for Spare Parts of the new & old replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and cost of new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. .
(ii) Necessary T&P i.e. ladder, tools,Vehicles etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.
(iii) Required screws, insulating tapes, internal wiring wire , gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
(iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition.
(v) Contractor’s quoted rates for Schedule `A' item No 1 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed.
(vi) The acredit rep of Contractor shall daily report to JE E/M and receive the complaints and job card of U/S street lights on each working day and details his electirician for repair/rectification and make the street lights in serciceable condition.
(vii) If his rep fails to report concerned JE, a panelty @ Rs. 500/- per day shall be recovered. The US/defective each street lights shall be got repaired and make functional within two days from the issue of job card failing to which 50/- per light per day shall be recovered as penalty charges.
(viii) All T&P and kits required for security purpose for operational works of equipment will be provided by the contractor to the workers. In case of any accident take place during operation to the worker, contractor will be responsible & give necessary medical aids and also compensation to the worker under compensation act 1923.
Supply only the following parts for LED fittings:-
(a) Driver for street light 45 Watts Make- Wipro Cat Part No-LG53-018-002-780 or equivalent models in Crompton Greaves/Philips.
(b) Driver for street light 60 Watts Make-Wipro Cat Part No-LG53-028-002-1540, WLD-LF19-711-60 or equivalent models in Crompton Greaves/ Philips.
(c) Driver for street light 70/90 Watts Make-Wipro Cat Part No-LG53-028-002-1540, LG56-036-002-1540 or equivalent models in Crompton Greaves /Philips.
(d) Driver for flood light 100 Watts Make-Wipro Cat Part No-LG75-100-050-1860, LG76-100-050-1860 or equivalent models in Crompton Greaves /Philips.
(e) Driver for flood light 120 Watts Make-Wipro Cat Part No-LG76-120-050-2190 or equivalent models in Crompton Greaves /Philips.
Disconnecting and Taking out U/S street light fittings any type, ( LED street light, LED flood lights, HPSV and MH lights) and fixing only street light fittings/security light fittings of any type and in any position on poles/walls/ pillars etc. including cleaning the acrylic cover, connecting the fittings with electric source with using suitable PVC insulated and sheathed flexible solid 2 core 2.5 Sqmm size copper/Aluminium conductor cable with testing of fittings complete all as specified and directed. (Note: Old serviceable Security light fittings/Street light fittings shall be segregated for re-use under this item)
Dismantling old U/S exiting Light Fittings and S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 flood light luminair with high power LED as light source 120 W LED 6000K with1.5 sqmm 3 core copper/aluminium conductor cable in replacement with existing HPSV /MH light fittings of any type complete all as specified and directed. (Make : Bajaj cat part No BJFL 120W LED or equivalent in Crompton Greaves /Wipro/Philips)
Dismantling old U/S exiting Light Fittings and S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP65 flood light luminair with high power LED as light source 30 W LED 4000K with1.5 sqmm 3 core copper/aluminium conductor cable in replacement with existing HPSV /MH light fittings of any type complete all as specified and directed . ( Make : Bajaj cat part No BJFL 60W LED or equivalent in Crompton Greaves /Wipro/Philips)
Dismantling old U/S exiting Light Fittings and S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 Street light luminair with high power LED as light source 45 W LED 4000K with1.5 sqmm 3 core copper/aluminium conductor cable in replacement with existing HPSV /MH light fittings of any type complete all as specified and directed. (Make : Bajaj cat part No BRLEP 45W LED V2 or equivalent in Crompton Greaves /Wipro/Philips)
Dismantling old U/S exiting Light Fittings and S&F Energy saving, environmental friendly, long life , Exlusive innovative die -cast aluminium IP66 Street light luminair with high power LED as light source 60 W LED 6000K with1.5 sqmm 3 core copper/ aluminium conductor cable and PVC conduit pipe 15 mm bore heavy duty ISI marked duly clamped with pole at 2 places from light fitting to over head line in replacement with existing HPSV /MH light fittings of any type complete all as specified and directed. (Make : Bajaj cat part No BRLEP 60W LED V2 or equivalent in Crompton Greaves /Wipro/Philips).
Taking down existing unserviceable Post Top light and Supplying, Fixing, connecting and testing outdoor LED Post top light fittings fully die cast Aluminium body finished with stove enamelled paint with acrylic window cover with Aluminium cover spigot entry 40 to 52 mm suitable for 4 to 12 W LED bulb including LED bulb complete all as specified and directed. Make: Bajaj Model Arian Cat Part No. BGCTW4 LED WW or equivalent model in Crompton Greaves/ Phillips.
S&F in replacement 2 mm thick CRCA sheet of existing size and shape as per requirement complete including all jointing material such as nuts, Bolts, Washers and necessary welding etc complete all as specified and directed.
Notes FOR SCH `A’ ITEM NO 9:- (i) The board repaired shall be made totally enclosed, weather proof, vermin proof for installation of incoming/ outgoing MCCB/ Switch fuses/ Cable etc. Complete as required and directed. Cost of the same deemed to be included in quoted rates. (ii) Rates quoted by contractors shall deemd to be included all necessary cutting, welding, levelling and jointing etc as directed to match & accommodate with the existing feeder pillar box/ Penal board. (iii) The replaced portion shall by painted with applying two coats of synthetic enamelled paint over and including one coat of red oxide primer. Cost of the same is deemed to be included in quoted rates.
M&L for preparation of old decorated existing external/ internal surfaces of feeder pillar boxes/ panels/Boards of any description and in any position including removal of disintegrated & deterioated paint either by hand scrapping or by blow lamps etc, applying necessary fillar coat and stopping as required and applying two coats of synthetic enamelled paint of shade as per direction of GE using spray machine complete all as specified and directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. (Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers).
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and direced.
Supplying and Lay Dry and clean fine sand for cable cushioning to under ground cable protection, complete all as specified. (Note :- only punned thickness shall be considered for measurement).
M&L for bricks for cover underground cable with one layer of bricks using sub class 'B' bricks (Old size) laid flat across the cable complete all as specified.
Laying Only bricks for cover underground cable with one layer of bricks using sub class 'B' bricks (Old size) laid flat across the cable complete all as specified.
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking out protection pipe , brick cover etc, cutting defective portion of cable and stacking properly for relaying and removal of defective cable from site complete all as specified and directed for the following sizes:
(a) LT aluminium conductor cable of size 10 sqmm to 16 Sqmm, any core.
(b) LT aluminium conductor cable of size 25 sqmm to 35 Sqmm, 4 core.
(c) LT aluminium conductor cable of size 50 sqmm to 95 Sqmm, 3.5 core.
Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :- Note: Serviceable cable obtained from item No. 17 above shall be reused .
(a) LT aluminium conductor cable of size 10 sqmm to 16 Sqmm, any core.
(b) LT aluminium conductor cable of size 25 sqmm to 35 Sqmm, 4 core.
(c) LT aluminium conductor cable of size 50 sqmm to 95 Sqmm, 3.5 core.
Supply, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to pole/ walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes:- (Make :- Polycab/Havells/Finolex )
(a) 16 Sqmm, 4 core
(b) 25 Sqmm, 4 core
(c) 35 Sqmm, 4 core
(d) 50 Sqmm, 3.5 core
(e) 70 Sqmm, 3.5 core
(f) 95 Sqmm, 3.5 core
(g) 10 Sqmm, 2 core
(h) 16 Sqmm 2 Core
Surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil. Complete all as specified.
Disconnecting existing LT over heated or burnt cable terminal at existing panel/ board/feeder pillar box etc., cutting out over heated / burnt / unserviceable and portion of cable, stretching / opening cable to suitable required length from available rings incluiding necessary excavation and earth work all as required at site etc. and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers etc. all as directed by the Engineer-in-Charge for the following sizes of cable :-
(a) 10 Sqmm to 35 Sqmm cable of any core
(b) 50 Sqmm to 120 Sqmm cable of any core
Dismantling and taking out old unserviceable existing MCCB of any description and in any position complete all as specified and directed.
Supply , fixing, testing and comissioning MCCB, 630 Amps , 4 pole, 415 volt AC supply, having breaking capacity 35/36 KA and with thermal setting 70% to 100%, adjustable load setting Complete all as specified. Make :-Standard Cat Part No. ISLCNF0630 or equivalent in L&T/ Legrand
Supply , fixing, testing and comissioning MCCB, 400 Amps , 4 pole, 415 volt AC supply, having breaking capacity 35/36 KA with adjustable load setting Complete all as specified. Make :-Standard Cat Part No. ISLCNF0400 or equivalent in L&T/ Legrand
Supply , fixing, testing and comissioning MCCB, 160 Amps , 4 pole, 415 volt AC supply, having breaking capacity 35/36 KA with adjustable load setting Complete all as specified. Make :-Standard Cat Part No. ISLCNF0160 or equivalent in L&T/ Legrand
Supply , fixing, testing and comissioning MCCB, 125 Amps , 4 pole, 415 volt AC supply, having breaking capacity icu=16 KA with adjustable load setting Complete all as specified. Make :-Standard Cat Part No. ISLCNF0125 or equivalent in L&T/ Legrand
Supply , fixing, testing and comissioning MCCB, 100 Amps , 4 pole, 415 volt AC supply, having breaking capacity icu=16KA with adjustable load setting Complete all as specified. Make :-Standard Cat Part No. ISLCNF0100 or equivalent in L&T/ Legrand
Disconnecting/ Dismantling /Taking out old spreader terminals adn S&F new spreader MCCB Terminals of Current Rating 75/100/125 Amps complete all as specified and directed. Make: C&S Cat Part No. CEST1044C or equivalent in L&T/Havells
Disconnecting/ Dismantling /Taking out old spreader terminals adn S&F new spreader MCCB Terminals of Current Rating 150/175/200/250 Amps complete all as specified and directed. Make: C&S Cat Part No. CEST2544 or equivalent in L&T/Havells
Disconnecting/ Dismantling /Taking out old spreader terminals adn S&F new spreader MCCB Terminals of Current Rating 500/630/700/800 Amps complete all as specified and directed. Make: C&S Cat Part No. CEST8044 or equivalent in L&T/Havells
Dismantling and taking out old unserviceable existing U/S Changeover switch any type, Supply and connected Euroload Four Pole 250 Amp 415 Volt 50 HZ Changeover with Advance Neutral, Open Execution conforming to IS 13947 (part-3); IEC:60947-3 . Complete all as specified and directed. ( Make :- Havells Ref No-IHCNFO0250 or equivalent in L&T and C&S)
Dimantling and Taking out old U/S time switch any type and in replacement S & F in Automatic street light Switch for automatic switching OFF street light at 30 Lux level and switching ON at 10 Lux of natural light the sensor along with suitable power Contactors of rating 63 Amps 3 Phase, MCB 63 Amps-03 Nos should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof, Termite proof and FR grade special moulding compound (Sintex make SMC junction box) conforming to IP55. The contactors, MCBs and circuit wiring should suitable enough to take load of 25 KW equially distribution over three phase 415 Volts A/C (Nature Switch MCB,Contactor and wiring suitable for the Make and model) all as specified and directed. (Make:- HAVELLS Cat Part No- IHXT509120 or equivalent Make in Legrand/L&T ).
Incoming (a) MCCB-630 Amps, 415 Volts, 4 Pole, AC with thermal setting 70% to 100% and breaking capacity icu=35/36 KA-01 No Make: Standard Cat Part No. ISLCNF0630 or equivalent in L&T/ Legrand
Outgoing (a) MCCB-315 Amps, 415 Volts, 4 Pole, AC with thermal setting 70% to 100% and breaking capacity icu=35/36 KA-01 No Make: Standard Cat Part No. ISLCNF0315 or equivalent in L&T/ Legrand (b) MCCB-200 Amps, 415 Volts, 4 Pole, AC with thermal setting 70% to 100% and breaking capacity icu=35/36 KA-02 Nos Make: Standard Cat Part No. ISLCNF0200 or equivalent in L&T/ Legrand (c) MCCB-125 Amps, 415 Volts, 4 Pole, AC with thermal setting 70% to 100% and breaking capacity icu=25 KA-02 Nos Make: Standard Cat Part No. ISLCNF0200 or equivalent in L&T/ Legrand (d) Spare place for fixing any switch gear in future- 02 Nos
Supplying, laying & jointing GI tubing 50 mm bore, light grade for passing of cables, fixed to poles/ laid under road crossing/ floor/ walls etc complete all as specified and directed. (MAKE : TATA/JINDAL/ SWASTIK).
Manish Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .