| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹28.4 L+₹1.7 L (6.45%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹28.6 L+₹2.0 L (7.47%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹29.0 L+₹2.3 L (8.74%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹29.0 L+₹2.3 L (8.76%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹49.9 L
EMD Value
₹99,720
Closing Date
1 May 2023, 6:00 pmClosed
MAJ SRINATH PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/REPLACEMENT OF EXTERNAL WATER SUPPLY DISTRIBUTION LINE, REPAIR TO DG SET WITH MISC WORKS INCLUDING REPAIR/MANTENACE OF SUMMER AND COOLING APPLIANCEs AT DGQA AREA UNDER GE(I) KANPUR.
2023_MES_589318_1
GE(I)/KAN/T-04 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KANPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(I) KANPUR
₹99,720
Yes
7 Jul 2023
13 Apr 2023
6 May 2023
13 Apr 2023
1 May 2023
26 Apr 2023
Amount
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes all as specified and directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as directed.
Removing excavated soils to a distance not exceeding 50 m and depositing where directed.
M&L for drilling hole at a depth up to 1.5 mtr below the normal ground level of suitable size to insert upto 150 mm dia pipe across the road in horizontal position complete all as directed.
M&L for cutting of road depth up to 1.5 mtr below the normal ground level of suitable size to lay pipe upto 150 mm dia pipe across the road in horizontal position incl making good all disturbed surfaces of road to match with existing surfaces by premix road material/PCC complete all as directed.
Disconnecting, dismantling and taking up or down old/unserviceable/cracked GI tubing with fittings of size 15 mm bore incl cleaning for refixing complete all as spfd and directed. Note: Excavation and earth work will be measured and paid separately under relevant items.
All as per Srl No 6 above but of size 20mm.
All as per Srl No 6 above but of size 25mm.
All as per Srl No 6 above but of size 40mm.
All as per Srl No 6 above but of size 50mm.
Re-laying, jointing and testing old but serviceable GI tubing 15mm dia (obtained from srl item No-6) and connection in new or old portion incl new fittings such as bends, elbows, union, tees, reducers etc as required at site laid in trenches or on floor or wall complete and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed.
All as per Srl No 11 above but of size 20mm (obtained from srl item No-7).
All as per Srl No 11 above but of size 25mm (obtained from srl item No-8).
All as per Srl No 11 above but of size 40mm (obtained from srl item No-9).
All as per Srl No 11 above but of size 50mm (obtained from srl item No-10).
Supply & Laying, jointing and leakage testing in replacement of GI tubing medium grade 15mm bore with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches/floor/walls and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and as directed at site. Make: Tata/Jindal/Prakash Surya. Notes :(i) The laying and jointing of pipes are required to be carried out in short / long streches catering to specific requirements of a purticular quarter or a group of blocks. (ii) Excavation & earth work shall be measured & paid seperately.
All as per Srl No 16 above but of size 20mm.
All as per Srl No 16 above but of size 25mm.
All as per Srl No 16 above but of size 40mm.
All as per Srl No 16 above but of size 50mm.
All as per Srl No 16 above but of size 80mm.
Disconnecting, dismaantling and taking down /GI/DI/Cemented pipe line of size 100mm bore, including all fittings with spigot and socket/ flanged end or any type, lead joint including removing from site complete all as specified and directed.
Re-laying, jointing and testing old but serviceable GI/DI pipe line of size 100mm bore after cleaning as taken down under Srl item No 22 here-in-before including all fittings as required at site complete and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and directed.
Supply fixing and testing DI pipe line of size 100mm bore, including all fittings with spigot and socket/ flanged end or any type, lead joint including removing from site complete all as specified and directed.
Supply fixing and testing DI pipe line of size 150mm bore, including all fittings with spigot and socket/ flanged end or any type, lead joint including removing from site complete all as specified and directed.
S&F in replacement of cast iron double flanged sluice valve of size 80mm bore class PN 1.0 confirming to IS 14846/2000 with with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including replacement of rubber packing complete all as specified and directed. Make : Kirloskar/Upadhyay.
All as per Srl No 26 but sluice valve of size 100mm.
All as per Srl No 26 but sluice valve of size 150mm.
M & L for boring on existing CI pipe upto 200 mm dia for branch connections of up to 50mm dia pipe by fixing of MS clamp 50x4mm cut to length and bent to shape, drilled and welded with GI socket of suitable size incl rubber packing, nut, bolt etc and testing complete all as specified and direted.
Repair to GI pipe lines of size 15mm to 25 mm bore dia and repair to leaked joints of pipe line complete including replacement of old GI fitting i.e union,nipple & sockets etc including excvation and taking up & down GI pipe required cutting & threading refixing in position in trenches and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed.(DGQA campus,Nepier Rd,Harding R & , supply depot ) Note: Excavation and earthwork shall be measured and paid separately under respective items
Repair to GI pipe lines of size 40mm to 80 mm bore bore dia and repair to leaked joints of pipe line complete including replacement of old GI fitting i.e union,nipple & sockets etc including excvation and taking up & down GI pipe required cutting & threading refixing in position in trenches and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed. Note: Excavation and earthwork shall be measured and paid separately under respective items (DGQA campus,Nepier Rd,Harding R & , supply depot )
Cutting existing CI/DI water main 150mm bore pipe in position for making branch connection and CI/DI pipeline (Insertion of CI/DI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation & earth work. Note : Fittings such as tees, bends, collars & reducers etc incl in this item and only run lead joints, CI/DI fittings & sluice valve shall be measured and paid separately and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed.
All as per srl No 32 but of size 100 mm.
All as per srl No 32 but of size 80mm.
M&L for Run lead joints complete with spun yarn of size 80mm dia all as spfd and directed.
All as per srl No 35 but of size 100 mm.
All as per srl No 35 but of size 150 mm.
M&L for Cast iron/ductile iron special fittings for spigot and socketed pipes such as bends (any type, radius and angle) socket tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, single branch, Y junction, double branch, cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore pipes complete all as specified and directed.
S & F in replacement of stop valve 20mm dia, gun metal iron, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe or for ferrule ISI marked including dismantling the old U/S existing valve complete.
M & L for opening up of leaking sluice valve 80mm and repacking of stuffing box & replacement of gland packing, nuts, bolts & washers etc complete all as specified of the following sizes :-
All as per item No-39 but of size 100 mm dia.
All as per item No-39 but of size 150 mm dia.
S & F in replacement of gun metal iron gate valve 25mm dia with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified including dismantling the old unserviceable existing valve complete.
All as per srl item 43 but of size 40 mm bore.
All as per srl item 43 but of size 50 mm bore.
M&L joints with rubber gaskets for CI flanged pipe including necessary nut bolts and washers etc for pipe 150 mm bore all as specified.
Cutting and removing unwanted grass and wild growth including bushes and shrubs from the roots at water supply installations including removing and even finish the entire area complete all as specified and directed at site by Engineer in charge.
Supply only sodium based granular having chlorine content 60-70 % disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite packing in 45 kg drum completed all as specified & directed. Make : Declibac/Brizing/Aquafit or E-in-Cs approved (Note: Contractor must produced TC & PVS from the manufactures/ All India Distributor at the time of supply for the Originality of material).
M & L for construction of valve pit chamber in replacement 600 x 600 x 950 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces incl dismantling and removal of old unserviceble valve pit remains all as specified and directed.
M & L for construction of valve pit chamber in replacement 950 x 950 x 950 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces including dismantling and removal of old unserviceble valve pit remains all as specified and directed.
S & F in replacement of fully automatic star delta starter, suitable for up to 30 HP submersible motor, 3 phase 440 volt complete with over load protection with adjustable relay range, electronic timer relay and single phasing preventor incl suitable size 40X4 mm angle iron frame grouted on wall for proper mounting arrangement all as specified. Make : SEIMENS / BCH / L & T
M&L for replacement of MS angle iron/Channel support for motor/pump incl nut bolt etc incl painting and making good all disturbed surfaces with PCC 1:2:4 complete all as spfd and directed.
Cleaning/removal of grass/bushes/plants/mud etc all around/inside the valve pit chamber up to size 950mm x 950mm x 950mm complete all as spd and directed all as specified and directed.
Taking up/down pipe line including excavation, returning filling and removal of excavated soil near existing pipe line of size 80 to 200 mm bore in break down maint of rising main line/distribution line. Providing any type of special tools & plants such as JCB & material (such as detachable joints/leak repair clamp suitable for CI/DI fittings, coller/short pieces of pipes or any other fittings as required to minimize the breakdown time and rectification of the problem as soon as possible. Rectification work must be start within two hours of intimation to contractor. Any delay in rectification may be penalized as deemed fit.
M&L for repairing the leakage of flange end joints for MS/CI pipe by doing welding incl replacement of rubber gasket, nut, bolt and washers etc bailing out pipe line water as required and directed for the sizes 150mm bore.
Taking / lifting out defective submersible pumps set from bore well complete with column pipe upto 150mm dia steel rope, submersible cable and accessories etc and relowering and commissioning the same after repairing works and testing complete of rating 20 to 40 HP 3 phase.
Dismantling, taking out complete burnt winding wire of submersible motor including cleaning of stator slots replacement of defective parts and rewinding with existing type & gauge of copper winding wire pvc insulated as per motor capacity and using new insulation material such as insulating paper sleeves etc.replacement of submersible cable as required size/ length complete incl testing all as directed of rating 5hp to 20 hp 3 phase. Noe : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor.
Dismantling submersible pump, straightening & polishing of pump shaft, making threading and key way, turning surfacing polishing to impellers, CI bowl complete including replacement of worn out parts as per requirement complete incl testing and all as directed of rating 5hp to 20 hp 3 Phase. Noe : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor.
S & F in replacement of Motor bush of gun metal upper and lower for 5 to 20 HP capacity (Set of two)
S & F in replacement of Rotor bearings sleeve upper and lower for 5 to 20 HP capacity, (set of two.)
S & F in replacement of coupling arrangement with key for motor for 5 to 20 HP capacity
S & F in replacement of Sand guard for submersible pump set for 5 to 20 HP capacity
S & F in replacement of Thrust bearing assembly for submersible pump set motor for the capacity 5 to 20 HP
S & F in replacement of Epoxy type cable jointing kit complete with all the jointing material, ferrule, for 1100 volts flat submersible copper conductor cable 16/10 Sqmm 3 core Make : M seal/Reychem/Birla 3 M
S & F of Rubber gasket (packing) suitable for 80 to 150 mm dia flange.
S & F in replacement of MS Nut bolts with spring washers of any sizes.
S & F in replacement of Steel wire rope stranded 12 mm dia for hanging of submersible pump set .
S & F in replacement of Electric cable for submersible pump set, flat 10 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed. Make- Finolex/ Paragon/Havells
S & F in replacement of impeller with key and distance bushes for 5 to 20 HP capacity pump
S & F in replacement of Pump shaft of stainless steel suitable for 20 to 30 HP capacity pump
S & F in replacement of NRV for 20 to 30 HP capacity pump
S & F in replacement of Bearing bush for submersible pump for 5 to 20 HP capacity.
S & F in replacement of Bowl assembly for submersible pump set for the capacity 5 to 20 HP
S & F in replacement of Distance sleeves for submersible pump for 20 to 30 HP capacity.
rewinding of electric driven centrifugal motor 3 to 10 HP capacity AC, 3 phase, 440 volt with superior quality insulated copper winding wire of identical gauge and specification of the existing short circuited winding wires with all necessary insulating materials & applying one coat of water proof epoxy paint to the exteriors of motor and refixing at site including rubber coupling , cleaning of slots and testing complete all as specified and directed. Note: The cost of transportation from pumphouse/yard to workshop and workshop to pumphouse/yard shall deemed to be included in item rate quoted by Contractor
Repair/servicing to complete DG set any make/modal 62.5 to 200 KVA water cooled diesel engine by taking out dismantling segregation of all parts and re-assembling after duly repair/ replacement of following new part fixing including all type machine work such as turning reaming etc, washing, cleaning, greasing , wires, replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note:- Any other accessories found unserviceable that shall be replaced & paid under respective items of this Sch.
S&F in replacement of Lub oil filter element for 62.5 to 200 KVA DG Set as per sample all as spfd.
S&F in replacement of Fuel filter element for 62.5 to 200 KVA DG Set as per sample all as spfd.
S&F in replacement of Dry type air cleaner for 62.5 to 200 KVA DG Set as per sample all as spfd.
S&F in replacement of V-Belt of fan for 62.5 to 200 KVA DG Set as per sample all as spfd.
S&F in replacement of By Pass Filter for 62.5 to 200 KVA DG Set as per sample all as spfd.
S&F in replacement of Electronic Governor Assy for 62.5 to 200 KVA DG Set as per sample all as spfd.
S&F in replacement of Starting switch of DG set up to cap 62.5 to 200 KVA as per sample all as spfd.
M&L for replacement of complete wiring (copper multistrand cable) of DG set any capacity as directed at site including thimble screw and sleaves etc
S&F in replacement of Gauge lube oil pressure of DG set cap 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of Hose pipe for of DG set cap 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of radiator hose pipe of DG set cap 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of Injector assy of DG set cap 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of Clamp hose radiator of DG set as per sample all as spfd.
S&F in replacement of water body of DG set 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of Turbo charging kit assembly of DG set 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of self starter 12/24 volt for DG set 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of AVR (Anti Voltage Regulator) for DG Set of capacity 62.5 to 200 KVA as per sample all as spfd.
S&F in replacement of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit as per sample for DG set 62.5 to 200 KVA as site requirment.
Repair of PT (Pressure time) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts , celebration for DG set of capacity 62.5 to 200 KVA & testing on completion.
Repair to radiator assy Cleaning washing throughly, descaling and M&L for replacement of rubber size paid and MS Nut & Bolts including brazing /repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complete incl nut, bolt, washers, & spring any type for DG set capacity 62.5 to 200 KVA.
Cleaning decarbonishing complete and spray painting to complete DG Set canopy outside of capacity 62.5 KVA to 200 KVA including writing SM No, Srl No, Make, capacity & date of installation as per sample all as directed.
Disconnecting, dismentling & repair to Dynamo with segregation of all parts supply and fix in replacement of armature field, coil, carbon brush and bearing etc reassembling complete & testing on completion.
M&L for replacement of Coolant for DG set of make : Castrol/Indian Oilor equivalent
M&L for replacement of Engine oil 20 W 40 complete all as spfd. make : Castrol/Indian Oilor equivalent
Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set all as spfd.
Supply and fixing in replacement of maintinance free battery 12 volt 180 AH 25 plate including battery leads and initial charging of battery. Make :Exide/Amron/
Disconnecting, dismantling and repair/servicing to self starter 12/24 volt and replacement of field coil, carbon brush, bush or other unserviceable parts parts and refixing complete and testing after completion.
M&L in replacement of microprocessor digital type DG set controller of DG set capcity 62.5 KVA to 100 KVA ( Make of DG set- Greaves Cooton) including connect all control wiring & programming all the parameter related to DG set at site complete.
S&F in replacement of Automatic battery charger AC input 230 + 10% V output DC for 12/24 volt battery current 10-15 Amp for 02 No batteries at a time with digital ammeter and voltmeter.
S& f in replacement of Battery terminal bolt type suitable for any tpe of battery.
S& f in replacement of Battery lead of copper conductor 35 Sqmm single core fitted with suitable terminal on both side.
M & L for winding of armature winding and field winding with super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc complete for DG set of capacity 75 to 380 KVA incl taking out the old burnt windings.
M & L for painting of Rising line , supply line over flow line, wash out line, fire point with equipment complete up to OHT height with cross arms, clamp of any lengt of all Pump House area with two coat of (red,black, blue) syenthatic paint after scraching out old paint, cleaning and existing surface rust free, preparation of the existing surface, including arrow marking of all water lines and painting with naming fire point(Pump house and Sub station) as existing , complete all as specified and directed by Engr-in-charge. Note :- Painting work will be considered as intire DGQA Area as per colour coading Norms
Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009including taking down old unserviceable complete all as specified & directed by Engr-in-charge
Repair, maint and making the continuity of supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigrator, ACs etc. including providing of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any accessories found unserviceable that shall be replaced & paid under respective items of this Sch. (ii) Contractor/ superviser of contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectify on next day morning . (iii) Complaint slip book, registers as per sample will be provided by the contractor .
Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, dismantling blades and handing over to MES staf for repairing with all accessories all as spfd and directed.
Assembling the fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired complete with all accessories all as spfd and directed.
Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified. Note :- 1. Repairs will be measured and paid separately under respective items.
Rewinding of AC ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block complete and all as specified.
S&F fan capacitor AC 440 volts 4 mfd 50HZ complete and all as specified. Make : Epcos/Usha/Havells.
All as per srl item No 6 here-in-before but 2.5 mfd.
All as per srl item No 6 here-in-before but 3.15 mfd.
Supply and fixing in replacement of gun metal bush suitable for any size / model / type of fans complete all as specified & directed.
M&L for repairs, alignment grinding to shaft, remetalling & finishing all as required .
S&F ceiling fan shaft of standard size including taking out old shaft, complete and all as specified.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed. Make : SSK/Cona/leader.
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified.
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified.
M&L in replacement of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete and all as specified Make : SKF/NBC/ABC.
Replacement of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete and all as specified Make : SKF/NBC/ABC.
Cleaning thoroughly ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
Cleaning thoroughly exhaust/wall/podestal fan 225 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
S&F in replacement of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 225 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long.
All as per item No 131 but of size 1 Mtrs long
All as per item No 131 but of size 1.5 Mtrs long
All as per item No 131 but of size 2 Mtrs long
All as per item No 131 but of size 3 Mtrs long
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed.
M&L for 40 mm bore galvanised iron tubing medium grade fixed to walls or hanging the fan including making hole and making good the disturbed surface by filling with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, plastered the surface and match the periodical such as oil bound distemper, white/colour wash etc with exisiting one complete all as specified and directed. Make: Tata/Jindal/Surya Prakash
All as per item No-1377 but of GI pipe of size 50mm bore.
M & L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells/Plaza.
All as per item No 139 but copper cable of size 1.5 Sqmm.
All as per item No 139 but copper cable of size 2.5 Sqmm.
M & L for taking down/out desert cooler from existing place and removing old paint from the body of desert cooler and applying painting on desert cooler external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed.
M & L in replacement of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler as per sample complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
Supply and fixing in replacement of water lifting pump submersible type 220 -240 Volts 50 HZ as per sample complete all as specified and directed. Make : Vansal model No OASIS SX6 (Submersible ) or equivalent make as approved by GE.
Supply & fixing in replacement of kit fan motor of desert cooler as per sample, 230 volts complete with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed. Make : Crompton / Havells / Khaitan / Usha.
S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed.
M & L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed
S & F of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed. Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
M&L for dismantling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as spfd and directed.
Disconnecting, dismantling old u/s indicator lamps and replaced with new all as spfd and directed. Make Anchor/Kay/Standard
Dismantling old PVC Water distributor four way and refixing with new as per sample and all as spfd and directed.
S&F in replacement of existing UNSV desert cooler blade as per sample and fix in the desert cooler and all as specified and directed by Engr-in-Charge. Make. Cromton graves or equivalent.
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window AC of 1.5 / 2 Ton capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately if required under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. (iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor
S&F inreplacement of cooling coil of window type AC any cap up to 2 ton all as spfd.
S&F in replacement of front grill of window AC suitable for 1.5/2 ton cap as per sample all as spfd and directed.
S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton cap as per sample all as spfd and directed.
S&F in replacement of Air blower moter as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase as per sample all as spfd and directed.
S&F in replacement of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd as per sample all as spfd and directed.
S&F in replacement of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton as per sample.
S&F in replacement of thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity all as spfd.
S&F in replacement of condenser fan blade suitable for window/split type AC of any make & capacity all as spfd and direceted.
M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spray painting with a coat of synthetic enamel paint of required shade complete all as specified and directed by the engineer -in -charge.
Disconnecting electrically and opening the cover of split AC 1.5/2 ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as directed by Engineer-in-Charge.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and fixing only new spares as per model / capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.
S&F in replacement of sealed compressor, rotary type, of any make as per sample suitable for split type AC of 1.5/2 Ton capacity all as spfd and directed.
S&F in replacement of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type all as spfd and directed.
S&F in replacement of discharge grill of outdoor unit of any size and type for split AC’s all as spfd and directed.
Supply and fixing in replacement of defective remote control hand set with "AAA" batteries for window/split type AC's, of any model / make complete all as specified and directed.
Supply and fixing in replacement of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed.
Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed.
Supply and fixing of copper tube as per existing and site requirement complete all as specified and directed.
Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete as per site requirement and as directed.
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort all as spfd and directed.
M&L for fixing/installation of split AC inner/outer or both unit as received from item No 69 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion all as spfd and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required.
supply and fixing in replacement of deoxidized annealed copper tube of as per sample including brazing etc. complete all as specified and directed.
supply and fixing in replacement of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed.
supply and fixing in replacement of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed.
S&F in replacement of Main control circuit (PCB) for window/split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia all as spfd and directed.
M & L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor's workshop including any welding / repair work reqd at site complete all as specified and as directed.
Supply and charging refrigerant R-22/R134a/R410 as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and as directed. Make : MEFRON/DUPONT
Disconnecting, dismantling old u/s compressor from refrigrator and replaced with new as per sample for the refrigerator of capacity 165 to 310 Ltrs including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed.
Supply and fixing in replacement of Starting relay suitable for refrigerator of any make and capacity. Make: Renutrol / Anapurna / Godrej / Whirlpool / LG.
Supply and fixing in replacement of Thermostat suitable for refrigerator of any make and capacity. Make: Indofos / Renutrol / Anapurna / Whirlpool.
Supply and fixing in replacement of PVC freezer door suitable for any size and capacity of the refrigerator.
Supply and fixing in replacement of Magnetic rubber door gasket suitable for any size and capacity of the refrigerator.
Supply and fixing in replacement of Copper liquid line filter two way / one way of refrigrator any type/capacity.
Supply and fixing in replacement of Over load protector of size 1/6 HP to 1/8 HP of refrigrator any type as per site requirement.
Supply and fixing in replacement of Capillary tube as per site requirement of refrigrator/water cooler any type.
Supply and fixing in replacement of Bulb of refrigrator any type as per site requirement of Make: Philips / Bajaj.
Supply and fixing in replacement of Ice tray twist type PVC of refrigrator any type.
Supply and fixing in replacement of Freezer of suitable size for refrigerator with door for refrigrator any type.
Supply and fixing in replacement of Condenser cooling coil suitable for refrigerator capacity min 165 ltr to maximum 310 ltrs.
Supply and fixing in replacement of Vegetable basket suitable for refrigerator as per site requirement.
Supply and fixing in replacement of Partition jalli /glass shelf suitable for refrigerator as per site requirement.
Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 1 to 5 KVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc all as spfd and directed. Note : Spare parts will be measured and paid seperately under respactive items.
Supply and fixing in replacement of Main relay of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of Main control circuit (PCB) of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of replacement of sensor transformer of voltage stabilizer 1 to 5 KVA as per sample.
Supply and fixing in replacement of voltmeter of voltage stabilizer 1 to 5 KVA as per sample. .
Supply and fixing in replacement of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 KVA as per sample.
Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair all as spfd and directed.
S&F in replacement of sealed compressor as per sample suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs as per sample.
S&F in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler.
S&F in replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator.
S&F in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample.
S&F in replacement of Starting relay of water cooler as per compressor requirement.
S&F in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement.
S&F in replacement of Over load protector of water cooler as per sample suitable for water coolers.
S&F in replacement of PVC flexible pipe transparent 15 / 20 mm dia (as per sample) for water cooler.
S&F in replacement of Push tap long body, cast copper alloy, chromium plated suitable for water cooler of capacity up to 150 ltrs (as per sample).
S&F in replacement of PVC float valve 15 / 20 mm dia with rod & ball for water cooler. Make: Prayag or equivalent.
S&F in replacement of Liquid line filter one way / two way for water cooler.
Supply and fixing in replacement of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed.
S & F in replacement of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed.
M & L for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed.
M & L for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed.
S&F of ceiling fan clamps for fixing with fan rod incd nut, bolt, lock pin, rubber real complete all as specified & directed.
S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers complete all as specified & directed.
G S SANDHU & CO.
SUSHMANAND ENGINEERING WORKS
NEW TECH ELCTRICALS
DEO Traders
Ashirwad Contractor and Supplier
M/S DARSHAN ENGINEERING WORKS
M/s A S Electrical
Charan sales and Service
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .