CWE (Subs) Mumbai
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
REPAIR MAINT OF HT INSTALLATIONS AND HT DISTRIBUTION NET WORK AT POWAI GHATKOPAR AND HAMLA UNDER GE NW BHANDUP
2020_MES_339173_1
8468/E8
Open Tender
Civil Works
Item Rate
300 days
Powai Hamla Ghatkopar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (NW) Bhandup
₹92,000
Yes
18 Aug 2020
21 May 2020
30 Jun 2020
21 May 2020
24 Jun 2020
15 Jun 2020
60 days
Amount
Filtration & Dehydration of transformer oil and HT OCB oil (at different locations) using ON-LINE filtration plant to achieve dielectric strength minimum 60 KV at 4mm gap including testing of oil before and after dehydation, complete all as specified and directed.
Supply only transformer oil conforming to IS 395-1983 (Make : 'Savita', 'Power Oil', APAR) having die electric strength minimum 70 KV at 4mm gap and submit oil report in writing before payment all as specified and directed, complete all as specified and directed.
Overhauling of step down outdoor/indoor transformer, 11/0.433 KV Dry type by disconnecting HT/LT terminals, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air and reassembling complete including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet suitable for transformer top cover, terminal boxes, painting with two coats of synthetic enamel paint and testing and recommissioning on load etc, complete for the transformers of following rating:- supply only of HT & LT bushings shall measured and paid separately under respective items):-
Transformer 500 KVA
Transformer 250 KVA
Overhauling of step down outdoor/indoor transformer (Make:- WESTERN / INDIAN Transformer Ltd / Voltas/ Vivekananda Transformer) 11/0.433 KV by disconnecting HT/LT terminals, decanning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet of 6 mm thick suitable for transformer top cover, terminal boxes, reassembling refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint after preparation of painted surfaces of transformer and testing and recommissioning on load etc, complete for the transformers of following rating (Filteration and dehydration of transformer oil, supply only transformer oil for topping up, supply only of HT & LT bushings shall be measured and paid separately under respective items) (Location- POWAI, GHATKOPAR AND HAMLA) :-
Transformer 750 KVA
Transformer 500 KVA
Transformer 400 KVA
Transformer 315 KVA
Transformer 250 KVA
Transformer 200 KVA
Transformer 160 KVA
Transformer 100 KVA
Supply of following spares for use during service work and left out spares can be kept in s/s for emergengy situation
Isolating contact assembly
Closing coil
Spring charging motor
Tripping Coil
Motor cut off switch liver
Buffer-Opening spring
Buffer -for closing spring
1- phase busbar spout for 800/1250A panel -R/B phase
1- phase busbar spout for 800/1250A panel - Y phase
1- phase busbar spout for 800/1250A panel - R/Y/B phase
Busbar support insulators-25KA, suitable for existing system including stainless steel nut bolts washers etc.
Rack-in/Rack-out handle
Space heater
Thermostat for space heater
Limit switch-1NO+ 1NC-service/Test position
Release coil assly with plunger w/o coil
Trip coil box assly with single plunger w/o coil
Pin for release prop
Supply and fixing vacuum interrupter bottle suitable for HT 11 KV existing VCB trolly 400 AMP complete all as specified of make CG model No: WL-34599M3+
Supply and fix in repairs HT bushing suitable for the following capacity transformer of make Western/Indian transformer Ltd/Voltas etc. complete all as specified and directed :-
For Transformer 750 KVA
For Transformer 500 KVA
For Transformer 400 KVA
For Transformer 315 KVA
For Transformer 250 KVA
For Transformer 200 KVA
For Transformer 160 KVA
For Transformer 100 KVA
Supply and fix in repair LT bushing suitable for the following capacity transformer of make Western/Indian transformer Ltd/Voltas etc. complete all as specified and directed :-
For Transformer 750 KVA
For Transformer 500 KVA
For Transformer 400 KVA
For Transformer 315 KVA
For Transformer 250 KVA
For Transformer 200 KVA
For Transformer 160 KVA
For Transformer 100 KVA
S&F in repair PT 11 KV / 110V, AC, 50 Hz, epoxy resin casting type with and including 3 Nos 2A / 3A PT fuses, cylindrical type, fixed indoor type etc, complete all as specified and directed.
Supply and fix in repairs silica gel breather for 11/0.433 KV transformer upto 750 KVA capacity with silica jel etc. complete all as specified and directed.
Supply and fixing in repair LED type RYB indicator set complete all as specified and directed
Supply and fix in repairs silica gel breather for 11/0.433 KV transformer upto 500 KVA capacity with silica jel etc. complete all as specified and directed.
S&F in repairs panel mounted digital type, PF meter, flush mounted, single phase, class 0.01 accuracy, 96mm x 96mm, including modiication of panel for fixing of PF meter, complete all as specified and directed.
Repairs and overhauling of HT 11 KV load break switch by replacement of worn out parts such as gaskets, washers, panel heaters, actuator and ant other required at site and cleaning the complete LBS and testing the same after repair for smooth functioning etc, complete all as specified and directed.
Repairs and overhauling of Air Circuit Breaker (ACB) 3/4 pole, 415 Volt, upto 1200 Amp with thermal magnetic release by replacement of worn out parts and cleaning the complete ACB and testing the same after repair for smooth functioning etc complete all as specified and directed.
Repairs and overhauling of Air Circuit Breaker (ACB) 3/4 pole, 415 Volt, upto 800 Amp with thermal magnetic release by replacement of worn out parts and cleaning the complete ACB and testing the same after repair for smooth functioning etc complete all as specified and directed.
Supply & Laying in repair 80 mm bore GI pipe medium grade in trenches for cable protection (for road crossing) all as specified and directed. (Note: Excavation and earth work shall be measured and paid separately).
Supply and fix in repair MCCB 4 pole, 415 Volt adjustable type with breaking capacity 36 KA from panel boards etc complete all as specified and directed of following rating
Supply & fix in repairs HT 11 KV cylindrical type fuse for load break switch, 16 Amps, complete all as specified and directed. Make : Bussmann/MEI/Eswari
Supply & fix in repairs HT 11 KV cylindrical type fuse for load break switch, 25Amps, complete all as specified and directed.Make : Bussmann/MEI/Eswari
Supply & fix in repairs HT 11 KV cylindrical type fuse for load break switch, 40 Amps, complete all as specified and directed.Make : Bussmann/MEI/Eswari
Supply & fix in repair cylindrical type PT fuse, 2A/3Amps, complete all as specified and directed, Make:- Bussmann/MEI/Eswari.
Supply and fix in repair battery charger 40 volt DC/25 Amp suitable for working on 230V and with output voltage of 40V DC and having 25 A capacity, 50 Hz single phase working on air natural cooling complete all as specified and directed. Make:- Power Guard Systems or equivalent as approved by GE.
Supply and fix in repair Power Pack Equipment suitable for working on 230V and with output voltage of 110V and having 300 VA capacity, complete all as specified and directed. Make:- Gogate Electro System (N) Pvt Ltd or equivalent as approved by GE.
Material and labour for preparation of existing painted steel surface of HT/LT panel by scraping and cleaning the surface and apply two coats of synthetic enamel paint by spray painting to achieve glossy finish in approved colour/shades including writing number and location of feeders with black paint etc complete all as specified and directed.
M&L for finding faults of HT UG cable XLPE, 11KV of any size and any length upto 185 Sqmm by using computerised / primary current injection method / any other method as directed by the GE and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed. Note: Joints shall be paid for separately.
Taking out existing unserviceable HT XLPE cable of size 3 core x 120 Sqmm (including joints where exists) and in lieu supply, laying in trenches/along wall/ pole/ in pipe etc, connecting and testing new HT under ground cable of size 3 Core 120 Sqmm, XLPE insulated, screened, eartherd, PVC sheathed, galvanised steel strip armoured (heavy duty), 11000 Volts grade with stranded aluminium conductor etc complete all as specified and directed. (Note: Excavation & earthwork, cable covers, protection pipes and sand cushioning shall be measured and paid seperately).
M&L for new earthing with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead strip of size 32 x 6 mm by mean of bolts, nuts, check nuts and washers of galvanised iron steel including necessary excavation, earth work, earth pit of PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) with RCC 1:2:4, 50mm thick cover reinfoced with XPM etc all as shown in electrical plate No. 03 of SSR 2009 Part I and connected to earthing test point all as specified including, funnel with GI watering pipe of 20mm bore medium grade & GI protection pipe 40mm bore light grade including testing etc complete all as specified and directed.
Taking out existing unserviceable HT XLPE cable of size 3 core x 95 Sqmm (including joints where exists) and in lieu supply, laying in trenches/along wall/ pole/ in pipe etc, connecting and testing new HT under ground cable of size 3 Core 95 Sqmm, XLPE insulated, screened, eartherd, PVC sheathed, galvanised steel strip armoured (heavy duty), 11000 Volts grade with stranded aluminium conductor etc complete all as specified and directed. (Note: Excavation & earthwork, cable covers, protection pipes and sand cushioning shall be measured and paid seperately).
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth in soft/loose soil for foundation or laying of cable and getting out etc complete all as specified and directed.
Returning filling, including spreading levelling, watering and well ramming in layers not exc 25cm thick etc complete all as specified and directed
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
M&L for filling sand for sand cushioning in trenches / ducts for cable protection all as specified and directed (note : Punned thickness will be measured and paid)
M&L for insulating IS-15652 mat suitable for 11 KV , 2.5 mm thick, corrugted, complete all as specified and directed.
M&L for rubber mat suitable for 433V of size 2m x 1m, 10mm thick, corrugted, complete all as specified and directed.
M&L for finding faults (any number in one running length) of HT UG cable XLPE 11KV of any size upto 185 Sqmm by using computerised / primary current injection method / any other method and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing including earth work all as required and directed. Note: Joints shall be paid for separately.
Material and labour for unreinfoced pre-cast concrete cable cover class HV type-1, flat of size 300mm x 180mm x 40mm etc complete all as specified and directed
Overhauling of HT OCB 11 KV, 400 Amps, 250 MVA of Make Crompton Greaves/MEI/GEC/Southern switch Gear installed at various locations after taking shut down from department and opening both incoming and outgoing connections, dismantling complete Circuit Breaker after detaching oil tank and draining out oil in a separate container and cleaning of oil tank thoroughly and carrying out the following repair work :- (i) Taking out complete parts of OCB separately viz. like ARC control pot assembly, jack ring , contact main, TULIP contact finger assembly, terminal bushing, moving contact block, fixed contact block, pick off spring assembly, moving ARC, Contact ARC, assembly of main moving contact, speed control device assembly etc and checking the same for its serviceability/ suitability for refixing, cleaning of all parts thoroughly as per standard practice, reassembling complete parts of OCBs including replacement of existing unserviceable spare parts all as approved and directed. (ii) Taking out complete parts of Truck & Hoist Assembly, after removing old grease checking the same for its suitability/ serviceability and reassembling complete truck and hoist assembly after replacement of defective parts all as approved and directed including greasing and oiling the complete mechanism as per standard practice. (iii) Servicing of dependent/independent mechanism and spring charging mechanism including replacement of minor spares comprising of scope as under :- (a) Recommissioning including testing of HT OCB for overload setting and adjustment complete (b) Recommissioning of complete Truck and Hoist assembly all as directed (iv) Checking/testing/servicing of tank assembly/barrier, solenoid machianism, trip unit assembly, BUS bar spout epoxy cast side entry cable base busing, arrangment with drawable type PT assembly of male female housing etc complete including repalcement of defective parts with new all as directed. (v) Over hauling of HT panel of each OCB including cleaning of bus bar chember, CT's and painting all exposed surfaces with one coat of insulation paint of same colour and replacement of control fuses, replacement of heater and bus bar insulators all as directed and painting Alphbet/Numbers with bold letters upto 5 cm height with black colour. NOTES: (i) Cost of all the materials, repairs and works as specified above as well as all the other elements (except followings) to make the OCB's fully functional shall be deemed to ve included in the quoted rates :- (a) Cost for filteration and dehydration transformer oil to achieve the desired dielectric value as catered for under item No. 3.00 here-in-before: (b) Cost for supply only additional transformer oil for topping-up as catered for under item No. 4.00 here-in-before: (ii) The above OCB's are located at : (a) MO (MB) Ghatkopar: 04 Nos (b) INS Hamla : 04 Nos
Overhauling and servicing through agency authorised by OEM of HT VCB, 11 KV, 400/630 Amps of make Megawin / AREVA / CG installed at various lacations including cleaning of all VCB contacts with CT's and replacement of minor parts such as Gaskets, washers, panel heater, indicator bulbs and carry out any other repairs required at site to make the VCB fully functional, complete all as specified and directed, Location:- Ghatkopar: 17 Nos, INS Hamla=04 Nos & Powai=07 Nos.
Overhauling and servicing through agency authorised by OEM of HT RMU 11 KV, 400/630 Amps of make Schneider / ABB installed at various locations including cleaning of all VCB contacts with CT's and replacement of minor parts such as Gasket, washers, panel heater and indicator bulbs and any other repair required at site to make the RMU fully functional, complete all as specified and directed, (Note :- The cost of filteration and dehydration of old transformer oil supply only for topping up of transformer oil and replacement of PT fuse will be measured and paid separately.) Location:- Ghatkopar: 03 Nos, INS Hamla=02 Nos
Servicing and overhauling of PT attached with OCB as per standard practice including taking out of transformer oil and refilling the same after filteration and dehydration, replacement of defective bushing, barrel fuse and repairs to damaged coil of PT, topping up the PT with new transformer oil upto desired level, commissioning and testing etc, complete all as specified and directed. (Note :- The cost of filteration and dehydration of old transformer oil supply only for topping up of transformer oil and replacement of PT fuse will be measured and paid separately.) Location:- Hamla
Caliberation of relays of HT VCB by secondary and primary injection, replacement of defective operating handles, checking of under voltage, over current relays and replacement of UNSV parts of master relays complete all as specified and directed.
Power factor improvement capacitor meataliszed poly propylene heavy duty (MPP-H) for 3 phase 440V 50 Hz system suitable to existing load of make Asian/EPCOS/L&T/C&S/HPL
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 Sqmm to 185 Sqmm with connecting single thimbles etc complete all as specified and directed.
S&F in repairs cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 50 Sqmm to 95 Sqmm, also with and including connecting single thimbles etc complete all as specified and directed.
S&F in repairs cable jointing kit for 11 KV (earthed) grade cable for outdoor straight through heat shrink type joint complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 50 Sqmm to 95 Sqmm also including connecting with single thimbles etc, complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium cable of size 95 Sqmm to 185 sqmm including connecting single thimbles etc complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium cable of size 120 Sqmm to 185 sqmm including connecting single thimbles etc complete all as specified and directed.
Supply and fixing of fire Extinguisher CO 2 type 2 Kg capacity to fixed on wall including fixing bracket complete all as specified and as directed.
Supply and fixing of fire Extinguisher CO 2 type 4.5/5 Kg capacity to fixed on wall including fixing bracket complete all as specified and as directed.
S&F fire Ball extingushier ABC Dry powder type, 1.3 Kg, for electrical installation complete all as specifed and directed
Supply and fixing in repair heating strip and supply and installed Fin strip terminals parallel, 400 Watt, 8" long mounted on insulator suitable for 11 KV HT panel for de-humidifying moisture with proper connection to existing panel and testing complete all as specified and directed.
Supply only First Aid kit complete all as specified and directed .
Supply and fix in replacement of 11 KV three phase CT cast resin made indoor type for metering and protection purpose of CT having rated current ratio 100/65/5 A for dual configure purpose with 15 VA secondary burden rating etc and conforming to IS - 2705 with accuracy class 0.5 complete all as specified and directed.
M&L attending the moisuture ingress problem in existing breaker with following scope Replacement of rusty hardware like nuts bolts etc Replacement of support insulators(The insulators will be provided by the contractor deemed to be included in the quoted rate) Replacement of spouts bushings bus side and cable side both (The insulators will be provided by the contractor deemed to be included in the quoted rate) Supply and implementation of hygrostats for humidity controller. Checkig the condition of existing heater and replacement of heater if requirement. Resetting of relay parameters.
M& L for pressure test suitable for 11 KV HT panel, VCBs, CT/PT bus bar complete and appling two coats of insulation spray complete and submit report in writing all as specified and directed
M&L for Plates chequered of Fe 410 W Gde E-250 quality A chalmels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed
M & L for servicing of battery bank of relay panel complete opening, cleaning and checking all circuites for its serviceablity and replacing consumable spares, complete all as specified and directed.
S&F in repairs Microprocessor controlled numeric relay, three phase, overcurrent and earth fault, auxillary voltage of 18-52 VDC, current setting from 0.1 to 25 IN with LED display for trip, alarm warning & auxillary output and back lit, LCD display of parameter with programmable key board settings -Type CGI14N of Make : CROMPTON GREAVES or equivalent of make AREVA/SIEMENS/EASUNRAYROLL as approved by the GE all as specified and directed.Location, Ghatkopar= 04 Nos.
Supply and fixing stainless steel nuts bolts and wahsers of various sizes complete all as specified and directed
Radha Engineering Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .