| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹49.7 L+₹1.4 L (2.87%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L2 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹46.3 L
EMD Value
₹92,500
Closing Date
24 Nov 2021, 6:00 pmClosed
GE Chennai
Garrison engineer, Fort saint George, Chennai
SPECIAL REPAIRS TO SERVANT QTRS BLDG NO XIII TO XIIG, SPECIAL REPAIRS TO SEWAGE LINE BUILDING NO P1 L BLOCK COOK HOUSE OR LINES AND NB BLOCK AT DB AREA OFFRS MESS AND CERTAIN OTHER SANCTIONED WORKS UNDER GE CHENNAI
2021_MES_484241_1
8562/E8
Open Tender
Civil Works
Item Rate
213 days
Fort saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹92,500
Yes
13 Jan 2022
27 Oct 2021
1 Dec 2021
27 Oct 2021
24 Nov 2021
10 Nov 2021
Amount
BOQ UPLOADED ON 08 NOV 2021
Surface dressing not exceeding 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation over area in hard/ dense soil n. exc. 1.50m deep for foundation, or for shafts, wells, cesspits, manholes, etc. and getting out complete all as specified and directed.
Excavation over area in hard/ dense soil exc. 1.50m but n. exc. 3.00m deep for foundation, or for shafts, wells, cesspits, manholes, etc. and getting out complete all as specified and directed.
Excavation in trenches in hard/ dense soil n. exc. 1.50m wide and n. exc. 1.50m deep for foundation, or for shafts, wells, cesspits, manholes, laying cable etc. n. exc. 10 sqm on plan and getting out complete all as specified and directed.
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for foundation, or for shafts, wells, cesspits, manholes, laying cable etc. n. exc. 10 sqm on plan and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil to a distance n. exc. 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Excavation in post holes (or similar holes) in soft/ loose soil each hole n. exc. 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surfaces complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n. exc. 63mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L loose filling of coarse sand in recharge pit all as specified and directed.
M&L loose filling of pea gravel of size 3mm to 5mm all as specified and directed.
Supply only integral water proofing compound all as specified and directed.
Supply only liquid water proofing compound all as specified and directed.
M&L for providing PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling, sub base of floors and mass concrete complete all as specified and directed.
M&L for providing PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling, sub base of floors and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping, kerbs, channels, water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc. complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L 40mm thick damp proof course to in cement concrete (1:2:4) type B-0 as on horizontal or vertical surfaces including necessary formwork and applying finishing coat of bitumen grade (VG-10) @ 1.50 Kg/ Sqm over a coat of bitumen primer complete all as specified and directed.
Extra for forming fair finishing to drain or channels 30cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc., complete all as specified and directed.
M&L for providing PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, deck slabs and the like all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in roof beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L for RCC (1:1½:3) type A-1 using 20mm graded stone aggregate as in roof slabs supported on walls, beams and columns in floors, roofs, deck slabs, cover slabs, shelves and the like complete all as specified and directed.
M&L for RCC (1:1½:3) type A-1 using 20mm graded stone aggregate as in precast cover slab with plain faces for manholes set in cement mortar (1:4) including necessary form work complete all as specified and directed.
M&L for RCC (1:1½:3) type A-1 using 20mm graded stone aggregate as in precast cover slab with plain faces for manholes set in cement mortar (1:4) including necessary form work complete including demolition of existing damaged concrete cover slab, separating, scraping and cleaning reinforcement and removing the rubbish off the premises outside Defence land complete all as specified and directed.
M&L for brickwork with old size fly ash bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with old size fly ash bricks straight or curved on plan to any radius in half brick thick walls in cement mortar (1:4) complete all as specified and directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area n. exc. 1.5 sqm each including separating guard bars/ grills/ wire mesh etc. complete all as specified and directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc. 1.5 sqm but not exc. 4sqm each including separating guard bars/ grills/ wire mesh etc. complete all as specified and directed.
Taking down shutters of any description n. exc. 1 sqm each including all fittings complete all as specified and as directed.
Taking down shutters of any description exc. 1 sqm but n. exc. 2 sqm each including all fittings complete all as specified and as directed.
M&L for second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F for 2nd class hardwood glazed and skeleton window/ ventilator shutters 30mm thick divided into squares open rebated and prepared to receive glass, gauge etc. edges of framing plain, chamfered, rounded fitted with cut and mitered beads for securing glass etc. size of members as specified in SSR Pt 1 section 8 clause 8.24(b) supplied and fitted to chowkats with plain, chamfered or rounded mitered and rebated sash bars any numbers, complete all as specified and directed.
S&F second class hard wood, plain framed, 35mm thick panelled shutters (any number of panels) with rails and panel of 12mm thick veneered particle board with commercial veneering on both faces, the size of rail and stile are as per IS 1003 (part I) Kiln seasoned and chemically pressure treated and fitted to chowkats complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, including supports, overhangs, etc. also splays between floors and beams complete of flat rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick of flat rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but not exc. 20cm wide flat rough finished surfaces of concrete all as specified and directed.
S&F stainless steel butt hinges, medium weight cold rolled 100mm size ISI marked all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 200mm long all as specified and directed.
S&F aluminium handles, fabricated type anodised 100mm size all as specified and directed.
S&F aluminium handles, fabricated type anodised 150mm size all as specified and directed.
S&F aluminium alloy anodised sliding door bolts 300mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections all as specified and as directed.
S&F hasp and staple 100mm size, aluminium anodised safety type with mild steel hinge pin including bolt to hinge plate fixed with screws complete all as specified and directed.
S&F continuous piano hinges mild steel bright finish or electro-galvanized width of flap (when open) 30mm complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wooden frames/Aluminium shutters complete all as specified.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wooden frames fixed in repairs complete all as specified.
M&L for mild steel work in bands, straps, supports of stays, sunshade brackets, hook and pintle hinges, clamps, hold fasts, guard bars, grills bolts etc and similar conforming to FE-290, Gde E 165 complete all as specified and directed.
M&L for 10mm dia and over mild steel TMT bars as in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L for 6mm to 8mm dia mild steel TMT bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and directed.
M&L for steel tubular trusses including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 including one shop coat of zinc chromate primer paint (including preparation of surfaces) at contractor's workshop before fabrication complete all as specified and directed.
S&F framed work such as grills, gratings etc., of any type and size of mesh as per site requirement for filtration of leaves etc. duly embedded in drain complete all as specified and directed.
S&F anodized powder coated aluminium (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilator with one or more rebates including joining cleats for fixing complete all as specified and directed.
S&F anodized aluminium powder coated (minimum thickness of powder coating 50 micron) panelled door shutter of aluminium section for frame work not less than 0.55 Kg/ RM including necessary joining cleats, glazing clips, rubber neoprene packing, 2 No. 150mm long handles, 02 No. 200mm long tower bolts, 03 No. aluminium B21 hinges and 01 No. aluminium mortice lock in each door, fully glazed for providing glass panes, prelaminated particle boards etc. including anodised aluminium snap beads, screws etc. complete all as specified and directed. Note: Glass panes and prelaminated particle board shall be measured and paid for separately under appropriate item of this BOQ.
S&F anodized aluminium powder coated (minimum thickness of powder coating 50 micron) windows and ventilator shutters, side hung type with sash bars, aluminium section weighing not less than 0.55 Kg/ RM including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stay 150mm long (01 No.), 100mm long hinges type B-21 (02 No.), handle 01 No in each shutter complete all as specified and directed.
S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength 550Mpa as in roof covering fixed with self tapping screws as per manufacturer’s instruction complete all as specified and directed.
M&L for galvanised powder coated snap grid framework for false ceiling all as specified including Vinyl laminated MPL gypsum panels (GYPTECH) 9mm thick of size of 60cm x 60cm fixing with staples on snap grid on RCC slabs by means of GI wire not less than 4mm dia, hooks and rawl plugs etc. at 1200mm c/c of make GYPTECH/ ARMSTRONG OR equivalent complete all as specified and directed.
M&L for 18/ 19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed to timber frame work with screws fixed in repairs complete all as specified and directed.
S&F pre-laminated particle board 9mm thick, interior grade pre-laminated on both sides with decorative choice lamination and fixed with snap beads/ screws to timber frame work complete all as specified and directed.
M&L for APP modified prefabricated polymeric membrane, 3mm thick of weight not less than 3.6Kg/Sqm reinforced with non-woven polyester matt, black finished on cold sticker and torch application of membrane with 10cm over lap after necessary preparation of roof surface over 10mm thick screed in cement mortar (1:4) when concrete is green with WPC as per manufacturer's instructions including water proofing treatment consisting of the following all as specified:- (i) One coat of bitumen primer @ 0.40 Kg/Sqm. (ii) One coat of bonding material of blown type bitumen of grade 85/25 heated with working temperature of 45°C and applied @ 1.20 Kg per square meter of the surface area. (iii) A layer of APP modified polymeric membrane of specified thickness and weight. (iv) Top most layer of surface finished with one coat of heat resisting aluminium paint. (v) Rate of WPC shall be inclusive in the quoted rate and nothing extra will be paid.
M&L complete removal of existing treatment from roof surface and applying APP modified prefabricated polymeric membrane, 3mm thick of weight not less than 3.6Kg/ Sqm reinforced with non-woven polyester matt, black finished on cold sticker and torch application of membrane with 10cm over lap over 10mm thick screed in cement mortar (1:4) when concrete is green with WPC as per manufacturer's instructions including water proofing treatment consisting of the following all as specified:- (i) One coat of bitumen primer @ 0.40 Kg/Sqm. (ii) One coat of bonding material of blown type bitumen of grade 85/ 25 heated with working temperature of 45°C and applied @ 1.20 Kg per square meter of the surface area. (iii) A layer of APP modified polymeric membrane of specified thickness and wieght. (iv) Top most layer of surface finished with one coat of heat resisting aluminium paint. (v) Rate of WPC shall be inclusive in the quoted rate and nothing extra will be paid.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified.
M&L nonskid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc. 0.06 Sqm but n. exc. 0.11 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L glazed coloured ceramic tiles of size 300mm x 600mm x 7mm thick laid on vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match the tile laid over and including 10mm thick backing coat in cement mortar (1:3) complete all as specified and as directed.
M&L for vitrified light shade coloured ceramic tiles 8 to 10mm thick (Square/ Rectangle) area of each tiles exc. 0.36 sqm but n. exc. 0.42 sqm each as in floors etc.; set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for chequered coloured (Designer) cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigment laid over and including 15mm thick screed bed in cement mortar (1:6) including dismantling of existing tiles complete all as specified and directed.
M&L for chequered coloured (Designer) cement concrete tiles 40cm x 40cm x 25mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and no pigment laid over and including 20mm thick screed bed in cement mortar (1:4) including dismantling of existing tiles complete all as specified and directed.
M&L 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor finished fair and even complete all as specified and as directed.
M&L 100mm thick PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in floor finished even and smooth complete all as specified and directed.
Roughening of old concrete surface by picking, sweeping cleaning and washing down with water to remove dust etc. complete all as specified and as directed.
M&L 75mm thick PCC (1:3:6) type C-2 using 40mm stone graded aggregate as in plinth protection including filling of joints by bitumen and sand in ratio (1:2) complete all as specified and directed.
M&L for 18 - 20mm thick machine cut granite slab (of any type), laid over and including 15mm thick cement screed in cement mortar (1:4), bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match with the shades of granite stone as in platforms/ cooking tops including cutting and polishing etc. including necessary moulding on edges and ole for gas pipe complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc including racking out of joint, hacking for key, scrubbing down with water etc. and removing the debris outside MD land complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick in two coats i.e. 1st coat 10mm thick in cement mortar (1:6) and 5mm thick finishing coat in cement mortar (1:4) mixed with and including PIDI PROOF LW compound @ 200ml per bag and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5mm thick in cement mortar (1:3) on ceiling finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on ceilings including preparation of newly plastered surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior acrylic emulsion paint (Apex Ultima of Asian or equivalent of other specified makes) over and including a coat of white primer complete all as specified and directed.
M&L for complete removal of existing treatment with electric operated blade, washing with water and bleaching powder solution on external surface of walls and applying two coats of Weather Proof Exterior Acrylic Emulsion paint (Apex Ultima of Asian or equivalent of other specified makes) over a coat of white primer complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over and including a coat of white primer and 2 to 3mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
S&F sheet glass 4mm thick plain ordinary quality and glazing with oil putty/ wooden beads as directed in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed.
S&F sheet glass 4mm thick plain ordinary quality and glazing with oil putty/ wooden beads as directed in squares exc. 0.50 Sqm in each pane complete all as specified and directed.
S&F sheet glass 4mm thick plain ordinary quality and glazing with oil putty/ wooden beads as directed in squares n. exc. 0.50 Sqm in each pane including hacking out old brocken glass panes complete all as specified and directed.
M&L preparation of new steel surfaces of any description not otherwise described over 10cm girth or width and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wooden or wood based surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old treated wooden or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron works new or old treating ends of posts, back of chowkats etc. with tar or coal tar black paint area tarred exc. 0.1 sqm but n. exc. 0.5sqm each complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron works new or old treating small articles such as hold fast etc with tar or coal tar black paint area tarred n.exc 0.1sqm each complete all as specified and directed.
S&F 15mm dia bib taps brass chromium plated, fancy type, long body with flange with crutch or butterfly handle screwed down, screwed for iron pipes or for brass ferrule and fixed in repairs complete all as specified and directed.
S&F in repair 600mm x 450mm bevelled edged looking mirror 6mm thick with aluminium frame work fitted with 6mm thick commercial ply or AC sheet backing to mirror and fixed to wall with raw plugs and chromium plated brass screws and cup washers etc., complete all as specified and directed.
S&F in repairs stainless steel sink with draining board of overall size 914mm x 460mm x 203mm and bowl size 405mm x 354mm x 203mm made out of 1mm thick stainless steel sheet of grade AI SI-304 with plugs, washers, waste coupling and 40mm dia waste pipe, fixed over CI brackets and connecting union to pipe etc., compete all as specified and directed. Make: Prayag Cat No. 1239D or equivalent from other makes specified in Particular specifications.
S&F galvanised steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
S&F galvanised steel water tubing 20mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
S&F galvanised steel water tubing 25mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
M&L for PVC (SWR) pipes of 110mm dia., single socketed in any length with rubber joints, laid in floor/ trenches and set in solvent complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including taking up/ down old pipe complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F 110mm dia PVC (SWR) bend any radius with access door all as specified and directed.
M&L for PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement fixed in repairs complete all as specified and directed.
M&L for PCC (1:4:8) type C-2 using 40mm graded stone aggregate as in concrete bed to 200mm bore SGSW drain pipe including packing under and haunching against the pipe after they are laid and tested complete all as specified and directed.
M&L for PCC (1:4:8) type C-2 using 40mm graded stone aggregate as in concrete bed to 200mm bore SGSW drain pipe including packing under and completely surrounding pipe with concrete after they are laid and tested complete all as specified and directed.
M&L for 200mm bore SGSW pipe laid and jointed complete with collars all as specified and directed.
M&L cutting into existing manholes for connecting new drains upto 200mm dia and making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate smooth finished & reforming benching as required complete all as specified and as directed.
M&L reinforced concrete pipe 200mm dia class NP2 laid over and jointed complete with collars all as specified and directed.
Demolition of brick masonry built in cement mortar including all quoins, arches, pillars, ashlars facings, dressed stone work and pre cast concrete articles etc., complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above GL including removal of debris to outside MD land complete all as specified and as directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, stair landings, chajjas and similar suspended works including separating, scraping and cleaning of reinforcement complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. including removal of debris to outside MD land complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc. or insulation boards/ slabs, blankets; of any thickness including cover fillets complete all as specified and directed.
Taking down old unserviceable/ damaged point wiring carefully of any size and description on teak wood batten/ through pipe (light, fan, socket etc) including removal of battens, pipes/ conduits, sockets, switches, shades, ceiling fittings, bulk head fittings ceiling rose etc complete and making good disturbed portion of wall to match with the existing surface all as specified and directed.
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/roof etc, including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light point controlled by one switch.
One Fan/ Exhaust fan point controlled by one switch.
One 3 pin 5 amps socket outlet on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch.
Bell/ buzzer point controlled by one bell push.
One light point controlled by two No. 2 way switches
M&L for point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100 V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provision of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5 Amps, 230 volts all as specified and directed.
Supply and fix switch piano, flush type, single pole, two way, 5 Amps, 230 volts all as specified and directed.
Supply and fix switch socket combination, 2 in 1, 5 Amps, 230 volts flush type all as specified and directed.
S&F switch socket combination flush type, 3 pin 15 Amps and 3 pin 5 Amps, 230 volts, 5 in 1, multipurpose, universal type complete all as specified and directed.
S&F ceiling rose PVC/ polycarbonate body 65 x 50mm 2 to 3 terminals 230 Volts, AC Single phase all as specified and directed.
Supply and fix call bell/ buzzer multi tune, 230 volts AC all as specified and directed.
Supply and fix bell bush, flush type, single pole, one way, 5 Amps, 230 volts all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fittings/ angle holder as required complete all as specified and directed.
S&F electronic ceiling fan regulator, flush type, 300 watts all as specified and directed.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatized, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 4 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatized, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing isolator TPN, 63 Amps, 415 volts including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 32 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 40 to 63 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply and fix environmental friendly, ultra-modern, energy saving, surface mounted 10 Watts LED decorative oval bulkhead edge-lit LED luminaire comprising of high brightness including taking down the old fitting complete all as specified and directed. Make: Havells Cat No. RUGBYNEONFT 10WLED860SSYMTOPC or equivalent of other specified makes.
S&F batten type luminaries with CRCA body, pre-coated in white and pre-wired for single LED tube light of capacity 22 Watts including LED tube with and including flexible twin core copper conductor 23/0.0076mm from ceiling rose to connector of tube light fitting including taking down old unserviceable fluorescent tube light fittings complete all as specified and directed. Make: Havells Cat Part No. LUMILINEPLUSBS22WLED865SPCSS or equivalent of other specified makes.
S&F batten type luminaries with CRCA body, pre-coated in white and pre-wired for single LED tube light of capacity 10 Watts including LED tube with and including flexible twin core copper conductor 23/0.0076mm from ceiling rose to connector of tube light fitting including taking down old unserviceable fluorescent tube light fittings complete all as specified and directed. Make: Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCSS or equivalent of other specified makes.
S&F high speed standard plain ceiling fan of 1200mm sweep (colour as approved by GE) 230V, 50HZ single phase fixed with suitable clamp and down rod (GI Pipe) including drilling, bolts, nuts etc. including taking down existing ceiling fan and depositing the same in the store yard of AGE E/M complete all as specified and directed.
S&F turbo force 4 blade (300mm sweep) exhaust fans AC single phase 230/ 240 volts, heavy duty corrosion resistant body rigid frame with rubber mountings for minimal noise operation & maintenance free design with pressure die cast aluminium rotor mounted on two ball bearings with maximum air with minimum power consumption conforming to IS: 2312-1967 complete all as specified and directed.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multi-stranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down old submain wiring complete all as specified. Note: Two runs of 6.0sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15mm bore light grade connected upto switch board including 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No. 3 of MES Schedule Part-I including dearth chamber of PCC (1:2:4) type B-1 using 20mm grade aggregate with 40mm thick RCC cover slab (1:1½:3) type A-0 using 12.5mm graded stone aggregate reinforced with 8mm dia TMT bars @ 100mm c/c both ways and 6mm dia MS lifting hooks including testing on completion including dismantling existing earthing complete all as specified and as directed.
M/s.Sai Agency
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .