| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹8.2 L+₹151 (0.02%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹8.7 L+₹55,271 (6.75%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹10.8 L+₹2.6 L (31.7%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest | |
| 5 | L5₹10.9 L+₹2.7 L (32.4%)Rejected-Finance | L5 | Rejected-Finance 5th Lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
6 May 2024, 6:00 pmClosed
CWE Mhow
HQ CWE MHOW MHOW CANTT MHOW-453441
REPAIR MAINT OF CENTRAL AC PLANT COOLING APPLIANCES WATER COOLER DESERT COOLER REFRIGERATORS SPLIT WINDOW TOWER ACs WITH OTHER CONNECTED ITEMS UNDER GE AWC MHOW
2024_MES_649028_1
CWE/MHOW/01(T) of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE Mhow
Pl refer tender docs
8 documents required · 8 mandatory
₹500
GE (AWC) MHOW
₹24,000
31 May 2024
2 Apr 2024
8 May 2024
2 Apr 2024
6 May 2024
23 Apr 2024
Amount
M&L for servicing of both (indoor & outdoor) unit of ACs of windows/ split type/ Cassette/Tower type of any capacity by cleaning coils with the use of c shine solution, removing internal dust and cleaning of filters by using water pump jet and air blower, oiling & greasing wherever required and checking of all other parts and proper cooling complete all as specified and directed . Note:-(i) All tools and machinery required deemed to be in quoted rates including servicing kit for indoor and outdoor unit with air compressor and servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge. (ii) All minor parts reqd for satisactory performance of the AC must be replaced and shall be deemed to be included in the above item rate.
M&L for servicing of both (indoor & outdoor) unit of AC's of split type /cassette type of any capacity (fitted on inside/outside wall at height of 25-40 feet and above) by cleaning coils with the use of c shine solution, removing internal dust and cleaning of filters by using water pump jet and air blower, oiling & greasing wherever required and checking of all other parts and proper cooling complete all as specified and directed . Note:-(i) All tools and machinery required deemed to be in quoted rates including servicing kit for indoor and outdoor unit with air compressor and servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge. (ii) All minor parts reqd for satisactory performance of the AC must be replaced and shall be deemed to be included in the above item rate.
M&L for taking down the indoor and outdoor and refixing it back to its original position or any other place after servicing of both (indoor & outdoor) unit of split type ACs . Note:-(i) All tools and machinery required for taking down and refixing deemed to be in quoted rates (ii) servicing of AC Shal be measured separately. (iii) spare parts copper tube and cable wire shall be measured separately.
M&L for Leakage testing of complete AC unit of any description and of any capacity after making all necessary arrangements in any position including vacuumising & pressure testing with and including dry Nitrogen Gas (N2) after necessary brazing and soldering etc complete all as specified and directed..
M&L for writing of SM/MES No etc on window AC/Split AC/Refrigerator/Water cooler/Deep freezer/Desert cooler with the help of stencil with synthetic enamel paint colour complete all as specified and directed.
Supply and fixing of copper tube suitable for split ACs of capacity 1.5/2 TR of the following sizes including dismantling of old U/S copper tube and insulation of the new copper tube 1/4 " inch
All as per Item No.06 above but size 3/8 "inch
All as per Item No.06 above but size 1/2 " inch
All as per Item No.06 above but size 5/8" inch
S & F in replacement of 20 mm dia transparent PVC heavy duty flexible pipe ISI marked with and including necessary clamps & nails for fixing the drain pipe for drainage of swetting water of indoor unit of split type ACs complete all as specified and directed.
S & F in replacement Blower/ Condenser fan blade (PVC) assembly of existing make & size suitable for window type ACs/Split ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
S & F in replacement Blower/ Condenser fan blade (PVC) assembly of existing make & size suitable for split/Cassette/Tower type of capacity 3.0/ 4.0TR complete all as specified and directed.
S & F in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for AC 1.5 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.
S & F in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for AC 2.0 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.
Supply and fixing in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for split/Cassette/Tower type AC 3.0/4.0 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.
Supply only refrigerant gas R-134 ( Non CFC) / R-407C in returnable sealed cylinder complete all as specified and directed by EIC.
Supply only refrigerant gas R-22/410/32 in returnable sealed cylinder complete all as specified and directed by EIC.
S & F of new air filters of size 13.3 inch * 8.6 inch or of suitable for existing model of 1.5/2 TR Split/Window AC including taking down the old U/s air filters.
Supply and fixing of new air filters of size of suitable for existing model of 3.0/4.0 TR Split/Window AC including taking down the old U/s air filters.
S & F in repair/replacement of printed control board panel (PCB) of existing make/ model suitable for window Acs/Split Acs of capacity 1.5/2.0 TR complete all as specified and directed.
S & F in repair/replacement of printed control board panel (PCB) of existing make/ model suitable for split/Cassette/Tower type AC 3.0/4.0 TR complete all as specified and directed.
S & F in repair/replacement of capillary tube/thermal expansion valve suitable for Split Acs/Window Acs /water cooler/refrigerator /deep freezer of existing make/model as reqd at site complete all as specified and directed.
S & F in replacement of battery operated cordless remote control of existing make/ model suitable for split type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
S & F in replacement of, PVC front grills of existing make, shape & size suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
S & F in replacement, air sweep louvers with motor complete set suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
S & F in replacement, PVC sheathed, 3 core copper conductor flexible cable of following size with thimbles of suitable size & shape complete all as specified and directed. 2.5 sqmm 3 core
All as per Item No. 23 above but size 1.5 sqmm 3 core
S&F in replacement, sheet metal enclosure (AC box) including a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 Volts complete all as specified & directed. Make:- legrand /L & T /Schneider
S&F of 3 pin 15 A plug top suitable for power load applications complete all as specified and directed by Engr-In-Charge.
M&L for bracket of power coated GI steel for outdoor unit and mounting with suitable size of anchor bolt and nuts complete all as specified & directed.
M&L for insulation of copper pipes (refrigerant gas pipes) with insulating materials of approved quality for better cooling effects of split type ACs or heat resistance/ protection of copper pipes from atmosphere including sealing/ covering the same with packing tape complete all as specified and directed.
Taking down & shifting of existing split type air conditioner of capacity 1.5/2.0TR to new location as directed including re-installation/ re-fixing the same at new location i.e outdoor and indoor units at new locations and making all necessary electric/ charging pipe line connections, commissioning and testing on completion and making good the disturbed surfaces of wall/ floor as per existing including comprising of the following accessories/ works complete all as specified and directed:- Note:- The rate quoted above will include all the necessary tools and spare parts required for its reinstallation including gas charging after carrying out leakage test and new drain pipe & copper pipe with insulation as required at site.
Disconnecting the existing refrigerators/Deep freezer of any capacity and transporting the same from site/AGE E/M Yard to workshop and back after necessary repair/ repair of old unserviceable or wornout accessories/ parts in the workshop and re-fixing/ re-connecting the same in existing position and testing on completion for efficient cooling complete all as specified and directed for the following capacities:- Note:- Gas charging and repair of spare parts of refrigerators shall be measured and paid separately under respective items of BOQ/ Sch'A' as "material and labour" complete.
S & F in repair/replacement, compressors of refrigerators/Deep freezer of following models including cutting the suction and discharge line for removing of un-serviceable compressors and fixing of new compressors by jointing suction & discharge line, welding, brazing/ soldering, vaccumising and charging of gas with required quantity of R-134(a) gas to achieve the efficient cooling & smooth functioning and testing on completion complete all as specified and directed:- Note:- Gas charging of refrigerators shall be measured and paid separately under respective items of BOQ/ Sch'A' as "material and labour" complete. Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 120 to 230 Ltrs capacity omplete all as specified and directed.
Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 240 to 500 Ltrs capacity complete all as specified and directed.
S & F in repair/replacement, PVC stand of refrigerators 100 ltr to 420 ltr of best quality suitable for refrigerators of OFF sizes complete all as specified and directed.
Labour for disconnecting, dismantling and taking out the water coolers of any description, any make and in any position having capacity 40 to 150 Ltrs, cleaning and servicing of the water cooler with using C shine solution, taking out or removing all unserviceable/ defective parts of water cooler and fixing of new spare parts/ items i.e wiring kit, compressor, condenser, condenser fan motor, relay, capicitors, thermostat, overload relay and including necessary brazing, vaccumising, gas charging, reassembling/ reinstallation of water cooler, making connections and testing complete all specified and directed. Note:- repair of unserviceable/ defective/ wornout parts/ spares of water coolers shall be measured and paid under respective items as ''Supply & Fixed''
S & F of new compressor for water cooler in repair suitable for 40/80 Ltrs capacity water cooler of any make and model complete all as specified and directed.Make:- kirloskar model KCE-444 HAG/ Tecumseh AE Model No 4440G.
S & F of new compressor for water cooler in repair suitable for 120/150/160 Ltrs capacity water coolers compete all as specified and directed. Make:- Tecumseh No AW-1000/AHR-13/ Kirloskar model KCJ 513 HAE-B-420/ 422 or KCJ 511 HAE B-420/ 440.
S & F' in repair of unserviceable PVC connection 15mm bore of 450 mm long with brass coupling with washers at both ends and connection to water cooler and water main complete all as specified and directed.Make-Prayagraj/Jyoti
S & F' in repair of unserviceable 15mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe or brass ferrule complete all as specified & directed. (Note-Min weight should not be less than 142 gms) Make:-Prayag /Jyoti
S&F in repair of MS bracket/base for fixing of condenser fan motor with 02 Nos rubber bush and 02 Nos GI clamp with & including 04 Nos MS nuts and bolts and washers suitable for any type & capacity condenser fan motor of water coolers complete all as specified and directed.
S & F in repair of unserviceable aluminium blade for condensing fan motor of water coolers of any model/ size as per existing complete all as specified and directed.
Disconnecting and taking out the defective/ non-functional desert cooler of any description and in any position/ installed at any floor . Strip opening of desert cooler, cleaning, servicing, oiling & greasing,painting of entire body etc of desert cooler, taking out and removing unserviceable/ defective parts and including replacement of unserviceable spares/ parts i.e condenser, internal wiring, re-assembling & testing of the desert cooler complete all as specified and directed. Note:- Replacement/repair of defective/ wornout spares/ parts of desert cooler i.e condenser & internal wiring shall be measured and paid separately under respective items as ''S&F in repair''.
S&F in replacement of unserviceable wood wool pads (set of three) in repair including PVC pipe pieces 03 Nos of required length & dia for connection of water distribution PVC elbows 03 Nos of desert coolers of (Approx) complete all as specified and directed.
S&F in replacement of unserviceable submersible pump for desert cooler in repair, heavy duty, single phase of power 20 to 150 watts and head 2 m complete all as specified and directed.
S&F of electric motor of desert coolers with copper winding heavy duty, 380mm sweep, 1400 RPM with all connected items reqd for its installation complete all as specified and directed.
S&F of metal fan blade set for desert coolers for medium and heavy duty coolers of any size complete all as specified and directed.
M&L for removing of perished body of desert cooler over all approx size of 0.750x0.750x0.910 mtr or as per existing size from existing site and replace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximet 0.750x0.750x0.230mtr and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally complete all as specified and directed by EIC.
S&F of detachable type perforated side panel in repair made out 22 gauge PGI sheet of desert coolers of size 90cmX90cmX75cm or existing size complete all as specified and directed by EIC.
S&F of front grills desert coolers in repair, size 18"x18" of each made out of 22 gauge sheet as per sample and including piano type switch complete all as specified and directed.
S&F 'C' series MCB SP, 6 to 32 Amps, 240 volts, 50Hz , 10kA complete all as specified & directed.
S&F 'C' series MCB SPN, 40 to 63 Amps, 240 volts, 50Hz , 10kA complete all as specified & directed.
Taking out existing defective/unserviceable rusted body of outdoor unit and dismantling of all the spare parts compressor, fan motor , fan blade and renewal with new out door unit body suitable for split type 1.5/2.0 TR complete with copper tube condensor heat exchanger and fins and refixing of compressor, fan motor and fan blade of old oudoor unit to new body with all connected items reqd for its installation complete all as specified and directed by Engr-in-charge.
Taking out existing defective/unserviceable body of indoor unit and dismantling of all the spare parts PCB , blower motor , blower and all conected parts and renewal with new indoor unit body suitable for split type 1.5/2.0 TR complete with all connected items i.e copper tube cooling coil,filter and refixng of blower, blower motor and PCB of old uns indoor body to new body with all connected items reqd for its installation complete all as specified and directed by Engr-in-charge.
Disconnecting of the unserviceable voltage stabilizers capacity upto 5 KVA from the site and removing to workshop for repair and re-fixing/testing/commissioning at the original position after rewinding / replacement of parts/spares to the extent required /reassembling complete all as specified and directed. Note :- Spares/parts shall be measured and paid seperately under respective items of BOQ as " Supply only".
Supply and fixing of voltage stablizers of 5 KVA capacity including its installation and connecting with the existing machinery.
Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete all as specified and directed.
Supply only volt meter 0 to 300 volts complete all as specified and directed
S&F in replacement of main PCB for voltage stabilizer 0.5 KVA to 5.0 KVA of approved make complete all as specified and directed.
S&F in replacement of auxiliary transformer for the 0.5 KVA to 5 KVA capacity stablizer of approved make complete all as specified and directed.
M&L for rewiring (wiring kit) of window/split/Cassette/Tower type ACs,water cooler,deep freezeer,refrigerator with using best quality PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed.
Supply and fixed in replacement, fins and tube type air cooled copper condensers of following capacity of any make complete all as specified and directed including taking down the old U/S fins:- Split type ACs of capacity 1.5TR/2 TR
All as per Item No.59 above but for Window type ACs of capacity 1.5TR
All as per Item No.59 above but for Refrigerator of capacity 120-200 ltrs.
All as per Item No.59 above but for Refrigerator of capacity 320 ltrs
All as per Item No.59 above but for Deep freezers of capacity 200 to 500 ltrs.
All as per Item No.59 above but for Water cooler of capacity 40 to 150 ltrs
Supply and fixing of Running/Starting aluminium body with lugs terminal capacitors of the following capacities for Acs/water coolers/ Refrigerators/ Deepfreezers/desert coolers etc.complete all as specified and directed by Engr-in-Charge Upto05-30 mfd
All as per Item No.60 above but Upto 30-80 mfd
All as per Item No.60 above but Upto 80-120 mfd
Supply and fixing of starting relay of approved make including dismantling old one suitable for the following :- Window type/Split type AC 1.5/2 Ton capacity
All as per Item No.61 above but for Refrigerator of 120 to 320 liters capacity.
All as per Item No.61 above but for Deep freezers of 200 to 500 ltrs capacity.
All as per Item No.61 above but for Water coolers 40 to 150 ltrs cooling capacity
Supply and replace thermostats of approved make including dismantling old one of the following:- Refrigerator of 120 to 320 liters capacity.
All as per Item No.62 above but for Deep freezers of 200 to 500 ltrs capacity.
All as per Item No.62 above but for Water coolers 40 to 150 ltrs cooling capacity
Supply and replace overload protector relay of approved make including dismantling old one of the following:- Window type/Split type AC 1.5/2 Ton capacity
All as per Item No.63 above but for Refrigerator of 120 to 320 liters capacity.
All as per Item No.63 above but for Deep freezers of 200 to 500 ltrs capacity.
All as per Item No.63 above but for Water coolers 40 to 150 ltrs cooling capacity
Supply and replace starting motor of approved make including dismantling old one of the following:- Outdoor motor suitable for split ac/window ac 1.5/2 TR.
All as per Item No.64 above but for Indoor blower motor suitable for split ac/window ac 1.5/2 TR.
All as per Item No.64 above but for Swing motor with flapper for split ac/window ac 1.5/2 TR.
All as per Item No.64 above but for Motor for water cooler 40 to 80 ltr/hr.
All as per Item No.64 above but for Motor for water cooler 80 to 150 ltr/hr.
All as per Item No.64 above but for Motor for double door refrigerator 280 to 320 ltr/hr.
All as per Item No.64 above but for Motor for deep freezer 200 to 500 ltr.
Supply and replace cooling coil complete made out of copper tube of approved make complete all as specified and as directed by Engineer-in-Charge of :- Window type/Split type room air conditioners of capacity 1.5/2 Ton cap.
All as per Item No.65 above but for Water coolers 80/120/150 ltrs capacity.
All as per Item No.65 above but for Refrigerator of upto 320 ltrs capacity.
All as per Item No.65 above but for Deep freezers of 200 to 500 ltrs capacity.
Supply & fixing ( in repairs) Drain pump for cassette type Ac's capacities of 4 TR, 220-240V, 50/60Hz complete all as specified and directed by Engineer-in-Charge.
M&L for Repair overhauling of exahaust system installed at 'B' Mess including check of all vents, leakage & water pipe lines etc complete all as specified and directed EIC.
Repair/Maint/Servicing of cold storage room ( plus temperature and minus temperature )of 'B mess' due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the cold storage functional by replacement/ renewal, complete all as specified and directed by Engr-in-Charge. Note:- (i) The minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Descaling of condenser unit by using cleaning solution, HCL, Sulphuric Acid, shoftner chemical, circulating pump, descaling brush, shoe, hand gloves, flange gaset, rubber insertation gasket etc. of capacity 37.5 TRX02 chiller complete all as specified & diected.
Descaling of condenser unit by using cleaning solution, HCL, Sulphuric Acid, shoftner chemical, circulating pump, descaling brush, shoue, hand gloves, flange gaset, rubber insertation gasket etc. of capacity 11.5TRX02 chiller complete all as specified & diected.
Repair/servicing of hot water generator of capacity 54kw including replacement of unserviceable element complete all as specified & diected.
Repair/servicing of hot water generator of capacity 22kw including replacement of unserviceable element complete all as specified & diected.
Repair and servicing of scroll type panel of capacity 37.5 TR cleaning all contactors and removing damaged electric cable and rewiring with the same gauge new copper wires and make functional complete all as specified and directed.
Repair and servicing of scroll type panel of capacity 11.5 TR cleaning all contactors and removing damaged electric cable and rewiring with the same gauge new copper wires and make functional complete all as specified and directed.
Maintenance/Servicing and attending complaint from in respect of non functioning of Air Conditioner plant of 37.5 x 2 TR capacity and 11.5 x 2 TR capacity due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the Plant functional and checking of all meters and make them functional complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/articles/gas renewed only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Repair/servicing of cooling tower tank of central Ac plant of 37.5TRX2 with removing of small leakage including foot valve and cleaning of fins by chemical complete all as specified & diected.
Repair/servicing of cooling tower tank of central Ac plant of 11.5TRX2 with removing of small leakage including foot valve and cleaning of fins by chemical complete all as specified & diected.
Servicing/ cleaning of AHU filter of suitable size complete all as specified & diected. Note :- (i) The contractor will collect the complaint slip at 9 am from the AGE E/M office and will ensure that the unserviceable ACs are rectified within 24 hours of receiving of complaints. (ii) If contractor fails to make ACs serviceable even within 48 hrs time then panel recovery of 500/- per day for each complaint will be made from contrator dues. (iii) The contractor will detail one rerigeration mechanicand one helper for AC and summer cooling appliances on a daily basis (iv) No absentee of refrigeration mechanic and helper will be permissible beyond one day and subjected to a recovery of 500 per day from contractor dues.
Vending Services And Solutions
shanti electricals
Mighty Steel Sales Crop
Ms Kailash Chandra Babulal
Vinayak Trading House
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .