Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹13.4 L+₹39,760 (3.06%)Rejected-Finance C O MANOJ KUMAR KESHRI MIRA SADAN ROAD NO 03 ANAND VIHAR NEAR WAXPOL FACTORY BOOTY MORE BUTI RANCHI JHARKHAND 834012 | RANCHI | RANCHI | JHARKHAND | 834012 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹14.1 L+₹1.1 L (8.41%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹14.5 L+₹1.5 L (11.4%)Rejected-Finance 85 D GHOSH PARA ROAD BARRAKPORE KOLKATA PIN 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹14.5 L+₹1.6 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹25,200
Closing Date
28 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DIPATOLI
GARRISON ENGINEER MES DIPATOLI MIL STN P.O. - HOTWAR RANCHI (JHARKHAND) 835217
PROVN OF TOILETS AT UNIT MT AREA OF 23 INF DIV SIG REGT (AREN) UNDER AGE B/R-II AT DIPATOLI MIL STATION
2020_MES_393260_1
8000/1623/E8
Open Tender
Construction Works
Item Rate
180 days
DIPATOLI
CLASS E CATEGORY a(i)
7 documents required · 7 mandatory
₹500
Yes
GE DIPATOLI
₹25,200
Yes
24 Dec 2020
7 Nov 2020
30 Nov 2020
7 Nov 2020
28 Nov 2020
21 Nov 2020
60 days
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, n.exc 10 sq.m on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation filling or mass concrete complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for brick work using sub class 'B' brick, curved or straight on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and as directed.
M&L for brick work with Sub-Class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L PCC (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in benching, side to path, bed blocks, coping and necessary use andwaste of form work complete all as specified and directed.
M&L for chequered cement concrete tile with grey cement and pigment of size (30cmx30cm) x20mm thick, with and including over 15mm thick screed bed in CM (1:6), set and joined and pointed in neat cement slurry with coloured cement and no pigment complete all as specified and directed.
M&L for 40mm thick cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in floors /sub base finished even and smooth without using extra cement complete all as specified and directed.
Returning/filling in including spreading, levelling, watering and well ramming etc in layer n. exc 25 cm thick complete all as specified and as directed.
Removing excavated soil to distance n. exc 50 mtr and deposited complete all as specified and directed complete all as specified and directed.
M&L for 15mm thick plastering on brick wall or concrete surfaces in CM (1:6), surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in CM (1:4) on brick/concrete surface, finished the surface even and smooth with using water proofing compound complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid seperetely.
M&L for rendering 5 mm thick cement plaster in CM (1:3), on fair faces of brick work or concrete surfaces of ceiling surface complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on wall complete all as specified and as directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer on walls, facia, chajjas etc complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for hard core of gauge n. exc 63 mm of broken stone or boulders, deposited, spread and leveled in layers n. exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection /path etc complete all as specified and directed.
S&F PVC door chowkhats of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supply & fixing in opening as per specification & drawing complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F stainless steel butt hinges 75mm long medium weight complete all as specified and as directed.
S&F aluminium anodised barrel tower bolt of extruded section and fixed of 150mm size complete all as specified and as directed.
S&F 125mm size aluminium handles, cast type anodised complete all as specified and as directed.
S&F 15mm dia stop valve cast copper alloy CP fancy type long body screwed to unioun or GI pipe etc. complete all as specified and as directed.
S&F 15mm dia stop valve (concealed type) cast copper alloy CP fancy type long body screwed to unioun or GI pipe etc complete all as specified and as directed.
S&F brass chromium plated shower rose 125mm size complete all as specified and as directed.
S&F GI water tubes medium grade 15mm bore with fittings laid in floors/walls complete all as specified and as directed .
S & F soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and as directed .
S&F vitreous china squatting pan, 'Orissa' pattern, size (580 x 440)mm white, with integral foot rests, including trap, set in and including concrete, connection to trap, and to flushing pipe, anti-syphonic pipe, etc complete including making good of floor (Excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.
S&F vitteous chinaware EWC (pedestal type closet) with and including white seat & cover with flat bottom with hinging device complete all as specified and as directed.
S&F vitreous china urinal bowl, flat back of size (465x355)mm x 265mm (minimum) white with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
S & F bib tap brass 15mm dia cast copper alloy chromium plated with butter fly handle CP fancy type complete all as specified and as directed.
S & F GI tubing 20mm bore medium grade with all GI fittings fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S & F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets , long bend including flush pipe of PVC 32mm dia and connection to pipes etc complete all as specified and directed .
S&F PVC connections 15mm size and 450mm length complete all as specified and as directed.
S&F 110mm PVC (SWR) WC connections short connections bent type complete all as specified and as directed.
S&F 110mm PVC (SWR) branch pieces, single equal or unequal complete all as specified and as directed.
S&F 110mm PVC (SWR) Bends any radius complete all as specified and as directed.
S&F 110mm PVC(SWR) vent cowls complete all as specified and as directed.
S&F PVC (SWR) 110mm pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) 110mm pipes single socketed in any length with rubber ring joints, fixed on wall complete all as specified and as directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
M&L cast iron 100mm floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
M&L providing pre-cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole cover slabs, set in CM (1:4) including necessary use and waste of form work complete all as specified and directed.
M&L for 10mm dia and over TMT bars in reinforcement, cut to length, bent to shape etc as required including binding with MS wire annealed not less than 0.90m dia complete all as specified and as directed.
M&L for TMT Mild steel bas 6mm to 8mm dia, cut to length , bent to shape required including cranking, bending spirally for hooping for columns, hokking ends and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securing with clip quality complete all as specified and as directed.
M&L for TMT mild steel bas 5mm dia and over upto and including 10mm dia in stirrup, spacers and binder and including mild steel wire (anealed) not less than 0.9mm dia or securing with clip quality complete all as specified and as directed.
M&L for 1000 Ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layered, hoisted and fixed in position complete all as specified in SSR Part I complete all as specified and as directed.
M&L for ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed 20mm bore complete all as specified and as directed.
M&L for preparing new surface of steel any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
S&F vitreous china wash basin white flat back size (550 x 400)mm including brackets, cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed.
S&F 40mm low density polyethylene (LDPE) pipes complete all as specified and as directed.
S&F pillar cock cast copper alloy 15mm dia CP fancy type complete all as specified and as directed.
S&F 32mm waste fittings brass chromimum plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S&F tubular towel rail, 20mm dia, D type, 60 cm long between flanges CP brass complete all as specified and as directed.
S & F 3mm thick sheet glass, figured glaass, pin headed in square n exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for 15mm thick screed in CM (1:6) on brick or concrete surfaces for fixing of tiles as in floor complete all as specified and as directed.
M&L for non skid ceramic coloured tiles of size (300 x 300)mm x 7 to 8 mm thick as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic colour tiles of size (300x200)mm x 7mm thick, as in dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay with glazing bars welded complete all as specified and as directed.
M&L PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes of 150mm bore, laid to slope including packing under and hanuching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for salt glazed stone ware drain pipe, grade 'A' 150mm bore (internal dia) laid in trenches on concrete bed to required slope jointed and tested complete all as specified and directed. Note:- Excavation/earth work and concrete bed shall be measured and paid separately.
M&L for PCC (1:2:4) type B-O, (using 12.5mm graded stone aggregate) as in manholes floors etc and to be finished even and smooth with using extra cement complete all as specifed and directed.
M&L for 10mm thick rendering in CM (1:4) on brick or concrete surfaces for fixing of tiles as in dado/skirting complete all as specified and as directed.
S&F stop valves, 20mm bore dia of pipe cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed
M&L for reinforced cement concrete in mix (1:1½:3) (using 20mm graded stone aggregates) as in foundations, including rafts, footings, plinth beams etc complete all as specified and as directed.
M&L for reinforced cement concrete in mix (1:1½:3) (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts etc complete all as specified and as directed.
M&L for reinforced cement concrete in mix (1:1½:3) (using 20mm graded stone aggregates) as in beams, cantilevers, bressum-mers lintels over 1.5m span etc complete all as specified and as directed.
M&L for reinforced cement concrete in mix (1:1½:3) (using 20mm graded stone aggregates) as in slab supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits of foundation and plinth beam, and similar work, vertical or batter work fair finished flat surface of concrete complete all as specified and as directed.
M&L for use and waste of formwork to side of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal, rough fiished surfaes of concrete complete all as specified and as directed.
M&L for use and waste of formwork to sides and of floor or roof beam, beam hauchings, girders, bressum-mers, lintels, cantileers, shelves including supports, overhangs, etc, also splays betwee floors and beams etc flat and rough finished suraces of concrete complete all as specified and as directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slab, etc flat not exceeding 200mm thick fair finished surface complete all as specified and as directed.
M&L for use and waste of form work to edges of concrete flats, treads, opening in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls etc for fair finished complete all as specified and as directed.
M&L for forming construction joints (30 mm deep x 10 mm wide), filled with sealing compound (1 part of bitument and 3 part of sand) complete all as specified and as directed.
M&L for forming square grooves in plaster n.exc 12mm deep and n exc 15mm on face complete all as specified and as directed.
M&L for roof treatment for non approachable roof in following stages:- (i) Rendering 10mm thick in cement mortar (1:3) mixed with liquid water proofing compound finished the surface fair and even (ii) Applying evenly a coat of bitumen primer @0.30kg/Sqm (iii) After primer, the entire roof surface shall be painted two coats over polymeric before and after laying polymeric membrane with hot blown bitumen grade 85/25 conforming to IS-702 @ 1.2 Kg/Sqm (iii) Applying APP modified polymeric membrane over the bitumen coat surface weight shall be 3.20-3.50Kg/Sqm and over lap 100mm and sealed by torch application as per manufacturer's instructions (iv) Applying a coat of alumunium paint @200gm/sqm in two coats over polymeric membrane.
M&L for point wiring with 2x1.5 Sqmm single core PVC insulated unsheathed copper multi stranded conductor (Phase-Red Colour and Neutral- Black Colour) in and including concealed PVC conduit of size 20mm for incomer circuit and 25 mm for out going circuit marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3mm thick sheet cover of suitable size complete including PVC insulated stranded copper conductor 1.5 Sqmm as earth wire (green colour) to common earth dolly for connection to ceiling rose to earth terminal including cutting chasses and making good distrubed surface to match with existing finish with plaster for One light/Fan point controlled by one one way switch complete all as specified and as directed.
Description all as per ser item No. 81 here-in-before but for one 3 pin socket outlet 5 Amps on the same board complete all as specified and as directed.
Description all as per ser item No. 81 here-in-before but for point wiring with 2.5 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continutiy complete all as specified and as directed.
S&F switch piano type single pole 5 amp 230 v complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 Pin, 5 amp complete all as specified and as directed.
S&F switch piano type single pole 15 amp 230 v complete all as specified and as directed.
S&F socket outlet 2 in 1, 6 Pin, 5 and 15 amp complete all as specified and as directed.
S&F ceiling rose surface type bakelite (65x50) mm three terminals complete all as specified and as directed.
S&F lamp holder PVC polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F LED tube light fitting 1x20 watt 230 Volt housing extruded aluminium heat sink, complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surface including fixing material/accessories complete all as specified and as directed.
S&F MCB SP 240 volt 6 to 32 Amps 'C' series 10 KA complete all as specified and directed.
S&F MCB DP 40 Amps 'C' Series 10 KA complete all as specified and directed.
Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm buried directly in ground vertically to depth not less than 2.25mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth wire of size 4.00 mm dia by means of nuts, bolts, check nuts, & washers made out galvanised iron or steel earth wire protected by galvanised iron pipe 20mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 30cm x 30cm x 10cm with one handle for lifting made out of 8mm dia MS bar, funnel wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 3 of MES Sch Pt-I all as specified and directed.
M&L for sand filling in cable trenches for cable protection with clean dry sand unwashed incl gently punning, complete all as specified and as directed. Note:- Thickness of punned surface shall be measured and paid.
M&L for bricks sub class 'B' kiln burnt, well burnt, laid as in trenches/cable cover/protection complete all as specified and as directed.
Supply, laying in trench/on walls as per site requirement, jointing, testing and commissioning with XLPE insulated, armourred, heavey duty, PVC sheathed electric cable with aluminum conductor, 1100 volts grade connecting to with new cable aluminium lug and cable glands of cross sectional area 16 sqmm 2 core complete all as specified and as directed. Note:- Excavation, earthwork and protection of cable shall be measured and paid seperately.
Supply and laying under roads, under culverts along poles light of GI pipe 40mm bore dia with all fittings as in cable protection complete all as specified and directed at site.
S&F in replacement metallic ventilating air fan single phase 300 mm sweep 900 RPM complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
S&F LED security light/street ligth fitting 35/36 watt with and including suitable size of GI bracket with clamp nut bolts, aluminium pressure die cast housing with touched glass cover (IP 66 protection) luminaire with high power LED as light source complete all as specified and as directed.
Boring of holes under road/hard standing or any other situation by manual mean for passing GI pipe 40mm bore grade and making good both the ends complete all as specified and directed.
Supplying, laying and jointing, threading into trenches / wall / roof / floor etc 25mm bore medium grade GI steel water tubing including all fittings complete all as specified and directed.
S&F gun metal globe or gate valve 25mm bore with iron wheet head, screwed both ends for iron pipe complete all as specified & as directed.
M&L for ferrule for tapping from existing water mains, straight plain brass ferrule or connecting screws both ends and fixed 25mm bore GI pipe complete all as specified and directed.
S&F LED lamps 18 watt capacity suitable for battens complete all as specified and directed.
M/S.R.S.Chauhan and Sons
Associated Engineers
Vp sanjiv
M/s R R MUKHERJEE & CO
M/s Mukesh and company
Ashis Enterprises
Elite Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .