Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹25.5 L+₹16,240 (0.64%)Rejected-Finance | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹25.9 L+₹64,478 (2.55%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹26.8 L+₹1.5 L (5.82%)Rejected-Finance | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹32.2 L+₹6.9 L (27.3%)Rejected-Finance 120 144 III PHASE APNA VIHAR JAMMU J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180010 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
16 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
PROVN OF GDT TOWER AT SATWARI
2021_MES_459311_1
CWEAFJ-10/2021-22
Open Tender
Civil Works
Item Rate
180 days
JAMMU
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (P) (AF) Jammu
₹80,000
Yes
2 Sept 2021
13 Jul 2021
18 Aug 2021
13 Jul 2021
16 Aug 2021
2 Aug 2021
60 days
Amount
Note : The height of the Building is approximately 10metres. The Contractor shall bear this aspect in mind and quote his rates for various items accordingly.
B/R Portion
Surface dressing not exceeding 15cm deep including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 15cm girth and height not excceding 1.5 metres and removing rubbish to a distance exceeding 250 metres but not exceeding 500 metres, complete all as specified and directed.
Surface Excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Anti-Termite Treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
Anti-Termite Treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
Anti-Termite Treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
Plain Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed.
RCC M-25 (design mix) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
RCC M-25 (design mix) in as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified & directed.
RCC M-25 (design mix) in as in staircase ,waist slab, treads, risers including landing and the like complete, complete all as specified & directed.
Formwork to sides of concrete foundation, footings, bases of columns, rafts and raft beams and similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finish flat surfaces of concrete, complete all as specified and as directed.
Formwork to Staircases with sloping or stepped soffits including risers and stringers, complete all as specified and as directed.
TMT bars 10mm dia and over, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete, all as specified and as directed.
TMT bars 6 to 8mm dia, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete, all as specified and as directed.
TMT bars 5mm dia and over as in stirrups, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete all as specified and as directed.
Preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as directed :- (a) Applying 1st course of 20mm thick screed bed with cement mortar 1:4 over concrete surface. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified prefabricated five layer polymeric membrane 3mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm end overlap.
(e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm and blended with fine sand in dry condition @ 0.50Kg/Sqm dusted over the bitumen coat. Note : The membrane shall be laid using butane torch. The membrane shall be first laid upto the parapet wall junction and then shall be overlapped with another membrane (flashing) with an overlap covering upto a distance of 300mm. In case the parapet height is less than 500mm, the membrane shall be terminated at the top of parapet.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
Rendering 5mm thick cement mortar 1:3 on concrete surfaces of ceilings finished even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound all as specified and as directed.
Hard core of broken stone gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and as directed.
75mm thick PCC 1:4:8, type D-1 (using 20mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and as directed.
16mm to 18mm thick of size not less than 53 x 53cm, machine cut Kota stone slab flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finish polishing, over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 all as specified and as directed.
16mm to 18mm thick, machine cut Kota stone as in riser or steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and rounding off edges complete with mirror finish polishing, over and including 10mm thick screed bed or bedding layer of cement mortar 1:4 all as specified and as directed.
Precast cement concrete coloured glazed interlocking tiles 80mm thick, M-50 grade, conforming to IS-15658 2006, any shade, colour and pattern laid over and including 20 to 30mm thick stone dust / sand cushioning laid dry to the profile including vibrating with surface vibrator after laying of tiles including budding and filleting joints etc. complete all as specified and directed.
75mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection etc., finishing surface even and fair without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete as specified and directed. Note : The concrete shall be laid at a stretch not exceeding 3.0m in length and joint shall be made at every turning / corners, complete all as specified and directed.
Pressed steel frame of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in back filling of pressed steel door frames and in bed block for holdfast and similar works etc. complete all as specified and directed.
35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete as specified and directed.
Steel Windows or Ventilator, fixed type, with glazing bars, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, 100mm size, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 250mm, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section and fixed complete of Size 150mm long complete all as specified and directed.
Aluminium handle cast type anodized of size 150mm, complete all as specified and directed.
3.0mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Mild steel works as Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410 (Gde E-250) quality A, complete all as specified & directed.
Preparation new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including a coat of wall care putty (Birla/JK) of average thickness 2 to 3mm, complete all as specified and as directed.
Preparation new plastered or previously untreated surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
Preparation new plastered surfaces of wall and applying two coats of Exterior Emulsion (Weatherproof Paint) over a coat of primer complete all as specified and as directed.
Preparation of new wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
E/M Portion
Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including concealed PVC conduit 20mm dia or more as per the site requirement including its fittings and fixtures such as ties, bends, elbows and junction boxes etc. including 1.50 Sqmm copper earth wire (green colour) FRLS Cable as earth continuity conductor connected to main earthing and common earth terminal for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sunken box and inner and outer plate for mounting of Modular Switches including cutting chases and making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 50 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 50 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed.
Modular switch 1 way 06 Amps, 1 module, complete all as specified and as directed.
Modular Socket, 06 Amps, 2/3 pin combined 2 module, complete all as specified and as directed.
Modular switch 1 way 16 Amps, 1 module, complete all as specified and as directed.
Modular Socket 6/16Amps, 2/3 pin combined 2 module, complete all as specified and as directed.
Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
LED Tube Light Fitting, 1 x 18 watt, single tube, 230 Volts, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Surface mounting powder coated white CRCA full glow LED panel functional and decorative luminare suitable for hang on bird proofing LED light fitting 42 watts complete with, connector block all accessories prewired with suitable size cable including connecting electrically using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or as directed.
Distribution Board, iron clad, Double Door with IP-43 1K-09 protection suitable for MCB TPN as incommer and MCB SP as outgoing, 415 Volts Three Phase 50 C/s, Four Way, complete with appropriate size copper bus bar and neutral link complete with rupturing capacity 10 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed.
MCB SP, 6 to 32 Amps 10 KA, 'C' curve type with rupturing capacity 10 KA complete all as specified and as directed.
MCB SPN, 63 Amps 10 KA, 'C' curve type with rupturing capacity 10 KA complete all as specified and as directed.
MCB TPN, 63 Amps 10 KA, 'C' curve type with rupturing capacity 10 KA complete all as specified and as directed.
Street Light fitting 30 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including fabricated mild steel bracket made of 50 x 50 x 6 mm and clamps of size 40 x 5mm including nuts, bolts and washers complete all as specified and as directed.
Integral LED Aviation Light fitting, 10 Watts, IP-65, comprising of die-cast aluminum housing with red polycarbonate dome for better illumination with integral driver, complete all as specified and as directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, one twin core cable flat or circular of size 6 Sqmm, with and including fitting arrangements viz. PVC conduit with clamps complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core including taking down / up unserviceable cable and making good disturbed surfaces, complete all as specified and directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note : Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub-class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick equal to the length of cable, complete all as specified and as directed.
Galvanized iron water tubing, light grade, 50mm bore for protection of cable with all fittings fixed to walls and ceilings or laid in floors/road crossing, complete all as specified and directed.
PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm, 3 Core, 1100 Volts grade complete all as specified and as directed.
Supply, installation, Commissiong & Testing of LT Feeder Pillar Box compartmentalised design of size not less than 70 x 70 x 25 cm suitable for 440 volt 3 phase 4 wire system made out of 2.5 mm CRCA sheet powder coated having gasketed front two hinged doors with locking arrangement including bottom and top detachable gland plate complete with suitable size of rust proof nuts, bolts, and washers etc. complete with mounting accessories including the following components :- (a) Four Nos 30cms long Copper bus bar 400 Amps mounted on epoxy insulators provided with rust proof nuts bolts and washers (b) LED indicating lamps - 3 Nos. (Red, Yellow, Blue) (c) MCCB, Four Pole, 415 Volt, 63 Amps capacity with 16 KA with adjustable thermal magnetic trip unit/release with Ics= 100% Icu qty 01 No (d) Changeover Switch 63 Amps - 01 No
Aluminium strip of size 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground / earthing strips all as directed.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically (earth plate not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including earth lead of GI Strip 32 x 6mm size by means of steel bolts, nuts, check nuts and washers test points made of GI strip 40 x 8 mm, 10 cm long, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), in pit, angle iron 25 x 25 x 3 mm frame work with precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) cover reinforced with 8 mm dia TMT bars @ 150 mm C/C both ways and 12 mm dia MS fabricated handle, light grade GI watering pipe 20 mm bore with funnel, wire mesh and light grade GI protection pipe 40 mm bore upto 7.5 m length for drawing in earth lead, salt, charcoal etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete all as shown in electrical plate No. 3 of MES schedule 2009 Part-I Including connecting and testing on completion all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire up to 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
M/S Vishwakarma Builders
Karmnaya Construction
SHALIMAR CONSTRUCTION CO
bamral builder
Continental Enterprises
Bidder Name
M/S Vishwakarma Builders
M/s Mohan lal
SHALIMAR CONSTRUCTION CO
Karmnaya Construction
bamral builder
Continental Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .