| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC EY 04 PODA WC CHANDIGARH A I A II B I | CHANDIGARH | CHANDIGARH | 160001 | L1 | Accepted-AOC beingL1 | |
| 2 | L2₹8.0 L+₹37,304.05 (4.89%)Rejected-Finance E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | L2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | L3₹8.3 L+₹70,681.35 (9.27%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L3 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 4 | L4₹8.6 L+₹1.0 L (13.2%)Rejected-Finance | L4 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 5 | L5₹9.1 L+₹1.5 L (19.8%)Rejected-Finance | L5 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹8.6 L
EMD Value
₹17,200
Closing Date
26 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
PROVISION OF CERTAIN MINOR WORKS B-R E-M AT AFAC COIMBATORE.
2022_MES_560396_1
8881_E8
Open Tender
Civil Works
Item Rate
120 days
COIMBATORE
Class-E category-a(i) (see NIT for detail)
6 documents required · 6 mandatory
₹500
AGE I AF Coimbatore
₹17,200
Yes
20 Dec 2022
29 Oct 2022
28 Nov 2022
29 Oct 2022
26 Nov 2022
12 Nov 2022
29 Oct 2022 - 19 Nov 2022
Amount
Provn of paved area with toe wall near building No. T-174 at AFAC Coimbatore Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil all as specified and directed.
Excavation in trenches not exc 1.50 mtr wide and not exc 1.50 mtr deep and getting out in hard/dense soil for foundation etc. all as specified and directed.
M&L for PCC 1:4:8 type D2 (40 mm graded stone aggregate) in foundation and mass concrete all as specified and directed.
M&L for Pre- cast cement concrete type C1 1:3:6 (20 mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for 100mm thick Cement concrete type D2, 1:4:8 (40mm graded stone aggregate) as in sub base all as specified and directed.
M&L for Hard core of gauge not exc 63 mm size with broken stone boulders deposited spread, leveled in layer n.exc 15cm thick, watered and well rammed to a true surface all specified and directed.
S& F Heavy duty Vitrified tiles 300x300mmx10mm in flooring all as specified and as directed.
M&L for Screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes all as specified and directed.
S& F Heavy duty Vitrified tiles 300x300mmx10mm in vertical surface all as specified and as directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 as in backing coat of skirting /dado all as specified and directed.
M & L for Filling under floors or in foundations including watering and consolidation all as specified and as directed.
Returning filling in trenches including spreading, leveling watering and well ramming in layers n exc 25 cm thick in hard/dense soils. all as specified and directed.
Removal of excavated soil to a distance n. exc 100m and depositing where directed at a level not exceeding 1.50m above the starting point including loading, unloading complete all as specified and as directed.
Provn of Store for SWO (B/R) work M & L Formwork to sides of concrete foundations, footings,bases of columns sides and soffits (if any) of foundation and plinth beams; and similar work;vertical or to batter for fair finished surfaces all as specified and directed.
M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces . all as specified and directed.
M & L Formwork to sides and soffits of floor or roof beams, beam haunching, girders bressummers, lintels, cantilevers, shelves incl supports, overhangs, etc also splays between floors and beams etc for fair finished surfaces. all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. all as specified and directed.
M & L for TMT bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. all as specified and directed.
Material and labour for reinforced cement concrete 1:1.5:3 type A-1 (nominal mix) (using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams bases for columns, etc. all as specified and directed.
Material and labour for reinforced cement concrete 1:1.5:3 type A-1 (nominal mix) (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed
Material and labour for reinforced cement concrete 1:1.5:3 type A-1 (nominal mix) (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and as directed
M & L for 75mm thick Cement concrete type D2, 1:4:8 (40mm graded stone aggregate) as in sub base all as specified and directed.
M & L for 40 mm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in floors finishing surface even and smooth using extra cement all as specified and directed.
M&L for Rendering in CM1:4, 15 mm thick on fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as specified and directed.
M&L for Rendering in CM1:6, 10 mm thick other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement. all as specified and directed.
Material and labour for preparation of newly plastered wall surfaces and applying three coats of white wash complete all as specified and as directed.
M&L for Preparation of new surfaces of walls and applying two coats of cement base paint over a coat of primer all as specified and directed.
S & F rolled mild steel work in tubular trusses including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240. all as specified and directed.
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc to FE 410-W (Gde-E-250) quality -A all as specified and directed.
S & F Pre - painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of any color having tensile stregth of 550 Mpa as in roof covering/cladding fixed to walls fixed with self tapping screws as specified.
S & F Pre - painted galvalume aluminium zink coating GI based plain steel sheet 0.50 mm thick of any color having tensile stregth of 550 Mpa as in roof covering/cladding fixed to walls fixed with self tapping screws as specified.
M & L for preparing new steel and iron surfaces of any description over 10 cm in width or girth, priming with red oxide and applying two coats of synthetic enamel paint over a coat of red oxide primer. all as specified and directed.
S & F for Second class hard wood Glazed and skeleton shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars),but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers all as specified and directed.
S & F for Second class hard wood with plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints. all as specified and directed.
S & F for framed work such as grills, gratings, etc.with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; framed balusters, conforming to Fe 290 Gde E 165 all as specified and directed.
S & F Butt hinges medium weight cold rolled mild steel, and fixed 75 mm size all as specified and directed.
S & F Extruded aluminium alloy handles fabricated type anodised size 100 mm all as specified and directed.
S & F Aluminium anodised barrel tower bolts extruded section 100 mm size all as specified and directed.
S & F MS hold fast for doors and windows etc complete all as specified and directed.
S & F Glass dividing 28mm thick strips, 3 mm thick inserted in position, conform to design all as specified and directed.
Preparation of new wood or wood based surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
Provn of Store for SWO (E/M) work M&L for concealed point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete including pressed steel sunken boxes 2 mm thick concealed in walls including 3 mm thick phenolic laminated sheet cover and including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor connected with dolly, all as specified and as directed for the following :- Note: ( Cutting chases and making good in wall / floor will be measured and paid separately.
One light point controlled by one, one way switch.
One ceiling fan point controlled by one, one way switch.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
S&F Switch piano, flush type single pole, one way 05 Amps complete all as specified and as directed.
Supply & fix universal regal LED batten with LED tube 1x20/22 watt surface mounting tube light fitting complete and making connection complete.
Supply and fix building security light 36 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 complete including fixing bracket of suitable size .
M&L for concealed Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc including making . Note :- 2 runs of 4 sqmm, 1 run of 4 sqmm (Earth Cotinuity conductor) and 1 Rm of PVC conduit shall be measured as one unit length
Supply and fix MCB DB, SPN, 4 ways, isolated neutral bar, IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete. all as specified and directed. Make: Indoasian / Havells/Standard
Supply and fix MCB SPN 10 Amps, 240Volts, 10 KA, "B" Curve complete all as specified and directed. Make:Indoasian Cat No. 811029 or equivalent in Havells/Standard
Supply and fix MCB SP 6 Amps, 240Volts, 10 KA, "B" Curve complete. Make:Indoasian Cat No. 811008 or equivalent in Havells/Standard
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth all as specified and directed.
Provision of Geysers at building No. P-27 (16 SQMs) at AFAC Coimbatore Supply and fix Electrical Water heater (Geyser) vertical type storage capcity 25 Ltrs, single phase, 2 KW complete including fixing arrangement such as hold fastners, nut/bolts/washers etc complete and testing.
M&L for GI tubing medium grade 15 mm bore, ISI marked with and including all necessary fittings complete all as specified and as directed.
Supply and fixing bib taps, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed of size 15 mm dia bore. all as specified and directed.
M&L for stop/gate valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed of size 15 mm bore, complete all as specified and as directed.
Cutting existing pipe 20/15 mm dia and including inserting of new "GI Tee 20mm x 20mm x 15mm / 15mm x 15mm x 15mm for connecting of GI pipe size 15 mm bore complete all as specified and as directed.
Supply and fix PVC connection 15 mm size with PTMT nuts of length 600 mm suitable for cold and hot water complete all as specified and as directed.
M&L for surface point wiring as per site requirement complete with 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete including pressed steel sunken boxes 2 mm thick concealed in walls including 3 mm thick phenolic laminated sheet cover and including 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor connected with dolly, complete all as specified and as directed for 3 pin socket outlet 15 Amps power point.
S&F multi socket outlet , 2 in 1, 3 pin, 15 Amps, flush type complete all as specified and as directed.
SEMBA ELECTRICALS
VIJAYA ENTERPRISES
DIVYA CONSTRUCTIONS
P JAYAPATHY & C0
SKM CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .