GE 873 EWS
Garrison Engineer 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF SHED FOR AVIATION TURBINE FUEL (ATF) REFUELLER TRUCK FIRE FIGHTING (TFF) AND HARD STANDING AT BASE CAMP-III UNDER GE 873 EWS
2026_MES_782529_1
GE/873/EWS-69/2026-27
Open Tender
Civil Works
Item Rate
270 days
GE 873 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE 873 EWS
₹1.2 L
Yes
7 Sept 2026
3 Aug 2026
9 Sept 2026
3 Aug 2026
7 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SCHEDULE 'A' PART-I (BUILDING/STRUCTURE WORKS)
Lump sum price worked out by the tenderer for "BUILDING/STRUCTURE WORKS" as listed in Schedule 'A' Part-I | 1 | LUMP SUM | 56,14,300 | ₹56,14,300 |
| 2 | SCHEDULE 'A' PART-II (HARDSTANDING WORKS)
Lump sum price worked out by the tenderer for "HARDSTANDING WORKS" as listed in Schedule 'A' Part-II | 1 | LUMP SUM | 2,49,634.84 | ₹2,49,634.84 |
| 3 | SCHEDULE 'A' PART-III (EXTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the tenderer for "EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule 'A' Part-III | 1 | LUMP SUM | 1,01,383.8 | ₹1,01,383.8 |
| 4 | SCHEDULE 'A' PART-IV (EARTH WORKS)
Lump sum price worked out by the tenderer for "EARTH WORKS" as listed in Schedule 'A' Part-IV | 1 | LUMP SUM | 93,723.71 | ₹93,723.71 |
| 5SCHEDULE 'A' PART-V (MISCELLANEOUS ITEMS) | |||||
| 5.01 | Supply and fix Double wall corrugated (DWC) outer pipe 40mm and inner dia 32 mm fix complete to Wall, Poles , laid in trench with cable etc with suitable clamp for protection of cable complete all as specified and directed. | 80 | RM | - | - |
| 5.02 | Supply and fix Double wall corrugated (DWC) outer pipe 63mm and inner dia 50 mm fix complete to Wall, Poles , laid in trench with cable etc with suitable clamp for protection of cable complete all as specified and directed. | 210 | RM | - | - |
| 5.03 | Supply ,Install Testing & Commissioning of self supporting totally enclosed double door at front, LT Feeder piller compartmentalised design, dust and varmin proof of size 1000 mm(Height) x 800 mm(Length) x 800 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon regid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom, complete after taking down the old unserviceable one. The Panel shall be emmbeded with 50x50 x 6 mm MS Angle Iron frame and to be grouted with PCC foundation (1:2:4 ) type B2 upto a height of 50 cm from normal ground level complete all as specified and directed by Engr in charge and comprising of the following. | 1 | Each Job | - | - |
| 5.04 | Incoming:-
(a) Copper bus bar 100 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
(b) MCCB of TPN, 63A, 16 KA, Make : L & T/Havells - 01 No
Outgoing:-
(c) MCCB of SPN, 40A, 16 KA, Make : L & T/Havells - 02 No
INDICATING DEVICES
(a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3
(b) Digital Voltmeter (Make AE/L&T) - 01 No
(c) Current Transformer having Ratio 400/5, 15 VA - 01 Set of 3
Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (ii) MCCB shall be fixed in suitable sheet metal enclouser (iii) Danger notice plate (02 Nos) LT size 20cmx 15cm shall be fixed on the panel (iv) Contractor provided power coated finish paint on panel. (v) Contractor have to provide panel drawing before carring panel at site. (v) Contractor have to provide panel drawing before carring panel at site. | - | - | - | - |
| 5.05 | Supply and fixing LTcable route direction metal sign board, yellow color circular plate with written indication and fixing arrangement on earth complete all as specified and directed. | 80 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_876707.xls
BOQ • 0.28 MB
Drawings.pdf
Additional Documents • 2.99 MB
Tender69.pdf
Tender Documents • 1.51 MB
Corrigendum69.pdf
PDF • 0.11 MB
Corrigendum69.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].