Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.1 L+₹29,380.10 (3.74%)Rejected-AOC | L2 | Rejected-AOC BEING NOT LOWEST | |
| 3 | L3₹8.6 L+₹79,355 (10.1%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-AOC BEING NOT LOWEST | |
| 4 | L4₹8.8 L+₹94,715 (12.1%)Rejected-AOC | L4 | Rejected-AOC BEING NOT LOWEST |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
10 Jul 2023, 6:00 pmClosed
GE 863 EWS
GE 863 EWS C/O 56 APO
REPAIR MAINTENANCE OF STREET LIGHTS POST TOP LANTERNS AND OTHER CONNECTED WORKS AT JHAKRI AVERIPATTI KARCHAM AND POARI IN THE AREA OF AGE E/M WE POOH UNDER GE 863 EWS
2023_MES_602851_1
GE863/EWS-T-34 OF 2023-24
Open Tender
Civil Works
Item Wise
180 days
KARCHAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹28,000
Yes
22 Aug 2023
12 Jun 2023
12 Jul 2023
12 Jun 2023
10 Jul 2023
26 Jun 2023
Amount
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete, all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm, complete, all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point, complete, all as specified and as directed.
Supply and laying sand in trenches for protection of cable, sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers, complete, all as specified and as directed.
Supply and lay well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete, all as specified and directed
Supply , Laying , testing and commissioning in replacement XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor , 1100 volts grade of size 16 sqmm 4 core,laid in trenches/fixed on pole/wall/passed through pipe complete all as specified and directed . Note : Earthwork and excavation shall be measured and paid for seperately. complete, all as specified & directed .
All as per ser item No 6 here in before but of 10 Sqmm 2 core
All as per ser item No 6 here in before but of 6 Sqmm 2 core
S & F in replacement of GI pipe light grade galvanized with all fittings laid in trenches for cable protection of 50 mm bore all as specified and directed
M & L for Plain cement concrete 1:2:4 type B1 using 20mm well graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary, complete, all as specified and directed.
M & L in replacement of Earthing complete with galvanised steel earth plate electrode 600 × 600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to pole/panel all as specified or indicated including testing on completion all as directed.
Supply and fixing LED Solar street light fitting 12 Watt including GI pole of 50 mm dia and 5m height, necessary excavation, earthwork , PCC work (1:2:4) type B1 using 20 mm graded stone aggregate & form work etc in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete, all as specified and directed.
Supply and fixing LED Solar street light fitting 16 Watt including GI pole of 50 mm dia and 5m height, necessary excavation, earthwork , PCC work (1:2:4) type B1 using 20 mm graded stone aggregate & form work etc in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete, all as specified and directed.
Supply and fixing LED Solar street light fitting 20 Watt including GI pole of 50 mm dia and 5m height, necessary excavation, earthwork , PCC work (1:2:4) type B1 using 20 mm graded stone aggregate & form work etc in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete, all as specified and directed.
S & F LED street light fitting 45 Watt, 230 V, AC ,outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete, all as specified and directed
S & F LED street light fitting 60 Watt, 230 V, AC ,outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete, all as specified and directed.
S & F LED flood light 100 watt 230 V, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete, all as specified and directed.
S & F post top lantern LED type 20 watt ,230 volts, AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete, all as specified and directed.
S & F in replacement of kiosk pole box made out of Engineering plastic comprising 60Amps, 4 pole aluminium strips, mounted on DMC insulator, size 250 x 200 x 100mm, complete, all as specified and directed
S&F in replacement of street light bracket made out of GI pipe light grade 40mm bore bent to shape as required at site for street light fitting 1.2 m in length and fixed on wall/pole including necessary MS clamps made out of ms flat 40x6 mm- 02 sets, nuts, bolts etc, complete, all as specified and as directed.
Taking down the defective / unserviceable street light/perimeter/post of lantern/flood lights fittings of any wattage, from the buildings/poles/post tops for repair and refixing the same after carrying out repair (replacement of spares like LED driver,etc shall be measured and paid seperately as supply only) complete, all as specified and directed
Supply only constant current led driver model suitable for 45 to 60 watt LED street Light, complete, all as specified and directed.
Supply only constant current led driver model suitable for 100 watt LED street Light/flood light, complete, all as specified and directed.
M & L in replacement sub main wiring with three single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed FRLS cable 1100 volts grade drawn into and including non-metalic rigid PVC conduit 20mm dia including accessories fixed on poles with proper bracings, complete, all as specified and directed.
M&L in Replacement of unserviceable wire/cable from junction box to light fitting fixed on pole on existing PVC conduit by PVC insulated unsheathed copper conductor FRLS of 1.5 sqmm, 3 runs.
Supply only battery electrolyte (distilled water with acid) for inverter battery, complete, all as specified and directed.
S & F in replacement of power contactor 4 pole, 32 amps, AC 220V including auxilliary contact arrangement with 1NO + 0NC, complete, all as specified and directed
Net Contract Sum will be after deducting Sch Of Credit of Rs. 46,190.00
JAMDAGNI ENGG WORKS
R B TRADERS
B S Ranbir and Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .