Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-Finance N A | NA | NA | 121004 | ₹5.4 L | L1 | Accepted-Finance OK |
| 2 | L2₹5.9 LAccepted-Finance | ₹5.9 L | L2 | Accepted-Finance OK |
| 3 | L3₹6.0 LAccepted-Finance | ₹6.0 L | L3 | Accepted-Finance OK |
| 4 | L4₹6.6 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹6.6 L | L4 | Accepted-Finance OK |
| 5 | L5₹7.0 LAccepted-Finance 21 10 SHOP NO 1 SECTOR 3 MAHABINI DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹7.0 L | L5 | Accepted-Finance OK |
Tender Value
₹10.1 L
EMD Value
₹20,128
Closing Date
6 Mar 2026, 3:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) North West, Elect. Divn., PWD ISBT, Kashmere Gate, Delhi-110006
3)RMO of various Electrical and Mechanical services at NCC Bhavan,Sec.-19, Rohini, Delhi (SH Servicing routine maintenance of STAC/WTAC and water coolers of different makes)
2026_PWD_287802_1
205/EE(E)/NWED/PWD/2025-26
Open Tender
Electrical Works
240 days
Rohini
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹20,128
Yes
9 Mar 2026
26 Feb 2026
6 Mar 2026
26 Feb 2026
6 Mar 2026
26 Feb 2026
Comprehensive routine maintenance of Window / Split type ACs units of 1.0 / 1.5 / 2.0 TR capacity units of different makes installed at various locations at NCC Bhawan, Asha Kiran, Pension office, Circle office, Sub Division office, Mukarba Chowk, Delhi, i/c repairing / replacement of remote, capacitor running type, all types of defective parts, gun metal taps, electronic parts, float valve assembly i/c PCB for indoor/outdoor, indoor/outdoor Fan motor for invertor and non invertor, indoor/outdoor cooling coil for invertor and non invertor and 3 core x 2.5 sq.mm wire complete as per terms and conditions, and timing as per direction of Engineer -in- charge & wherever reqd. (Note:- i) During the period of Summer Season & duration as specified by the Engineer-in-Charge ii) Maintaining of Complaints will be recorded by the agency in the AC Task/Complaint register) (170 Units X 8 Months = 1360 Units)
Comprehensive running maintenance of capacity of 100/150 litres different makes water cooler units installed at various locations at NCC Bhawan, Asha Kiran, Pension office, Circle office, Sub Division office, Mukarba Chowk, Delhi including repairing/ replacement of condenser motor, compressor & all type of defective parts such as Gun metal taps, float valve assembly, Supplying and charging of refrigerant gas in case of leakage including condenser coil & cooling coil etc complete as per terms & conditions attached. (30 Units X 8 Months = 240 Units)
Complete servicing of WTAC/STAC/unit of different capacity including dismantling the AC from its existing position at various locations/grill/window cutting, washing with High pressure water spray electric machine coil cleaning with D- Scaling Chemical, drying with air blower ,oiling, greasing, of blower fans cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, as required in its existing position complete as per direction of Engineer -in- charge & wherever reqd. a) Window type AC unit/Split type AC of 1.5 TR / 2.0 TR / 3.0 TR capacity
b) Water coolers of capacities 100/150 Ltrs
Supplying & charging of Refrigerant gas (R-22/32/refrigerant suitable as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumizing and gas charging complete as required. (Note:- Quantity of gas filled shall be entered in Consumption Register maintained by the agency) a) In 1.5 TR STAC capacity
b) In 2.0 TR STAC capacity
Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 5/8"and 3/8" suitable for 2 TR STAC duly insulated by nitrile rubber, covered with MS pipe for safety of the pipe along with necessary support, clamps, brackets as required as per site requirement.
Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 1/2"and 1/4" suitable for 1.5 TR STAC duly insulated by nitrile rubber, covererd with MS pipe for safety of the pipe along with necessary support,clamps,brackets as required as per site requirement.
Supplying and replacement of following parts including removal of un-serveceable part, electrical connections & re-installation the same, testing, commissioning etc. as required. (Labour & gas charges already included in below mentioned item.) a) Rotary Compressor 1.5 Ton
b) Rotary Compressor 2 Ton
c) Reciprocating compressor 1.5 Ton
d) Reciprocating compressor 2.0 Ton
e) AC Indoor Unit 1.5/2 Ton Inverter / Non Inverter
f) AC Outdoor Unit 1.5/2 Ton Inverter / Non Inverter
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Dismantling of existing suitable 1.5 TR/2.0 TR capacity WTAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd.
Re-Installation of STAC Unit existing suitable 1.5 TR/2.0 TR capacity STAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd.
Credit of buy back of dismantled materials a) Copper Pipe/Cables
b) AC Outdoor Unit inverter/non inverter
c) Rotary Compressor 1.5 Ton
d) Rotary Compressor 2 Ton
e) Reciprocating compressor 1.5 Ton
f) Reciprocating compressor 2.0 Ton
g) AC Indoor Unit 1.5/2 Ton Inverter / Non Inverter
h) AC Outdoor Unit 1.5/2 Ton Inverter / Non Inverter
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.80 MB
BOQ_381473.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid