Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC | ₹1.3 Cr | 1 | Accepted-AOC Due to lower rate |
| 2 | 2₹1.3 Cr+₹4.8 L (3.68%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹1.3 Cr+₹4.8 L (3.68%) | 2 | Rejected-AOC Due to Higher rate |
| 3 | 3₹1.4 Cr+₹5.7 L (4.36%)Rejected-AOC | ₹1.4 Cr+₹5.7 L (4.36%) | 3 | Rejected-AOC Due to Higher rate |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
29 Sept 2021, 2:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PUBLIC HEALTH ENGINEERING DIVISION NARWANA
Const. of 1 no CWT Const of 2nd Bstn Repair of 2 No SS tank 8 no FB 3 no CWT BWall PC SS well VNotch houdies Laying cutting jointing esting of 100 mm 150 mm 200 mm 250 mm 300 mm id DI pipeline
2021_HRY_188068_1
SE No. 5422 dated 07.09.2021
Open Limited
Civil Works
Tender
15 days
NARWANA
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2.9 L
Yes
6 Nov 2021
14 Sept 2021
29 Sept 2021
14 Sept 2021
29 Sept 2021
14 Sept 2021
Amount
Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum four (4) star rating durites directly coupled to AC squirrel cage induction type motor with 1440 RPM, 3 phase, 50Hz and accessories as described in Schedule No. II complete in all respects with priming arrangement with complete base frame. A) Raw Water pump set 2800 LPM 12 mtr. Head
B) Clear water Pump set 2800 LPM 40 Mtr. Head
A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items. A) For Raw water Pump set for 2800 LPM x 12 Mtr. head = 2 Nos. (a) Main switch 100 Amp. 2 no. (L&T Siemens, ABB) (b) Volt meter 100 x 100mm range 0 to 500 volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100 x 100mm range 0 to 100 volt 2 no. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/L&T) (e) VSS&ASS 1no. & 2 Nos of approved make (f) SPP 2 no. of approved make (g) Motor starter, star delta 2no. for 2800 LPM x 12 M Head Motor (L&T Siemens, AAB) (h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp = one set. (j) Change over switch 100 Amp = 1 No.
B) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items. B) For Clear water Pump set for 2800 LPM x 40 Mtr. head = 2 Nos. (a) Main switch 100 Amp. 2 no. (L&T Siemens, ABB) (b) Volt meter 100 x 100mm range 0 to 500 volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100 x 100mm range 0 to 100 volt 2 no. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/L&T) (e) VSS&ASS 1no. & 2 Nos of approved make (f) SPP 2 no. of approved make (g) Motor starter, star delta 2no. for 2800 LPM x 40 M Head Motor (L&T Siemens, AAB) (h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp = one set. (j) Change over switch 100 Amp = 1 No.
C) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items. B) For Clear water Pump set for 400 LPM x 30 Mtr. head = 2 Nos. (a) Main switch 63 Amp. 2 no. (L&T Siemens, ABB) (b) Volt meter 100 x 100mm range 0 to 500 volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100 x 100mm range 0 to 100 volt 2 no. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/L&T) (e) VSS&ASS 1no. & 2 Nos of approved make (f) SPP 2 no. of approved make (g) Motor starter, star delta 2no. for 400 LPM x 30 M Head Motor (L&T Siemens, AAB) (h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp = one set. (j) Change over switch 63 Amp = 1 No.
D) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items. B) For Clear water Pump set for 400 LPM x 40 Mtr. head = 2 Nos. (a) Main switch 63 Amp. 2 no. (L&T Siemens, ABB) (b) Volt meter 100 x 100mm range 0 to 500 volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100 x 100mm range 0 to 100 volt 2 no. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/L&T) (e) VSS&ASS 1no. & 2 Nos of approved make (f) SPP 2 no. of approved make (g) Motor starter, star delta 2no. for 400 LPM x 40 M Head Motor (L&T Siemens, AAB) (h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp = one set. (j) Change over switch 63 Amp = 1 No.
Supply, erection, testing of ISI marked copper wire for 6 No. Motors with under ground system in PVC & flexible pipes copper wire complete in all respects with accessories like thimble etc. Complete in respects. i) 6 sq mm
Supply, erection, testing of ISI marked copper wire for 4 Nos panel boards from main switch to panel and wiring of panel with size 10 sq. mm (copper wire) ISI marked complete in all respects with accessories like thimble etc. Complete in respects.
Supply, erection, testing of reputed make LED light 100 watts with fitting and accessories complete in respects
Supply, erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduct pipe & copper wire etc. as per approved specifications complete in respects.
Bidder Name
Amount
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
Umesh Kumar Contractor(GSTN-NA)
Shiv Shakti(GSTN-NA)
Umesh Kumar Contractor
Shiv Shakti
Umesh Kumar Contractor
ROHTASH KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .