| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance | -7.96% | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 CrAdmitted-Finance 00 SUBHASH WARD DONGARGARH RAJNANDGAON RAJNANDGAON CHHATTISGARH 491445 UDYAM CG 15 0004239 | RAJNANDGAON | CHHATTISGARH | 491445 | +0.00% | ₹1.7 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical technically not quallified |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
15 Jan 2026, 5:00 pmClosed
ADMINISTRATOR JMT NAGAR PARISHAD
NAGAR PARISHAD JMT
CONSTRUCTION OF DEVELOPMENT OF VENDING ZONES SHOPS WITH BASIC INFRASTRUCTURE AND PUBLIC AMENITIES FOR STREET VENDOR NEAR GANDHI SCHOOL.
2026_UDD_108685_2
JMC/04/2025-26(2nd Call)
Open Tender
Civil Works - Buildings
365 days
JHUMRI TELAIYA
2 documents required · 2 mandatory
₹10,000
₹3.4 L
20 Apr 2026
7 Jan 2026
17 Jan 2026
7 Jan 2026
15 Jan 2026
7 Jan 2026
7 Jan 2026 - 15 Jan 2026
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B)
Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Providing TMT steel reinforcement above 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. 8 mm (Only Valid for SAIL & TATA Steel)
10mm (Only Valid for SAIL & TATA Steel)
12,16,20,25 mm (Only Valid for SAIL & TATA Steel)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roof , landings,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, abutments, Posts and struts
providing designation 75 B brickwork in C M (1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9"x4'5"x3" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials,n caffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Providing and laying of brick bats including cost of material, labour charges etc complete as per specification & E/I
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately).
Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings- and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses.
Supplying,fitting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 SQM
Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% or any approved water proffing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :- (a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.
Providing and mixing Liquid lntergral water proofing compound in Conctrete or plaster as per rnanufacturer specificatioqand as per cjirection of Eng - in Charge Brand- Sika Plastocrate plus, MYK proof WP 1 0, Fosroc-Cc.rnplast X4211 C, Dr fixit Pidiproof LW+ or Equivalent
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
OUTDOOR FURNITURE Supply and Installation of Precast Concrete Reinforced Square Cement Flower Pots Material - Cement Shape (When viewed from Top) Square Artistic /Decorative work on Pots Yes Pot Length (mm) 18 inch Pot Width (mm) 18 inch Pot Height (mm) 18.5 inch
Supply and Installation of Precast Concrete Reinforced Bench M-30 Grade concrete mix in accordance with IS : 10269/Latest in gray cement by using vibro - compaction technique and with reinforcement as detailed in Govng. specn. ach seating plank ( bottom ) of bench bolted with leg by help of 12 mm dia. X 65 mm length galvanized steel countersunk bolts with EVA washer – Backrest planks fitted with half threaded carriage bolts and nuts of size 165 mm X 8 mm dia with EVA & steel washer Seat / plank length ± 3 mm = 1500MM Seat height ± 3 mm = 450 MM Seat width ± 3 mm = 440 MM
ROAD WORK 5.50 MTR WIDE Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Plant mix method (Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401) (ii) Rate per cum for grading-II Material
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved color design and pattern.
Cast-in-Situ Cement Concrete M20 Kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class- B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.120 cm equilateral triangle
EXTERNAL ELECTRICAL WORKS Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply and erection of 7 Mtr. height Octagonal Hot - Dip galvanized pole( BOP - 7030) with top dia 70 mm, bottom dia L30 mm & made of 3 mm thick sheet, base plate dimensions200X 200X12mm ( Lx B xT) including suitable sizes of foundation bolt all complete as reqd. (Without Arm)
lnstallation, Testing & Commissioning of the 7 Mtr. Octagonal Pole & light fitting with the help of suitable tools and plants, and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity of 10T/mhs sq. but excluding wire and MCB.
lnstallation, Testing & Commissioning of the 1 m Sinele Arm suitbale for 70mm Top for 7 Mtr. Octagonal Pole.
Supply of following sizes sizes of PVC insulated PVC sheathed aluminium conductor armoured 1.1 KV grade as as required. 2C x 6 sq mm
2C x 10 sq mm
2C x 16 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade. 2C x 6 sq mm
2C x 10 sq mm
2C x 16 sq mm
Supplying and fixing of outdoor type junction box( IP 67 ) suitable to incoming and outgoing up to 16 sq. mm Al Armoured Cable. The juction box shall also be suitable for 3 Nos. outgoing circuits each consisitng of 3 Nos. 2.5 sq mm copper wired wires
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
2X2.5 sq. mm + 1X 2.5 sq. mm earth wire
PVC/ XLPE insulated PVC sheathed heavy duty, armoured electrical cables with Aluminium conductor for working voltage upto and including 1100volts ( conforms to IS:1554, Part-1) 3.1/2 core 35sq. mm.
4 core 16sq. mm.
4 core 10 sq. mm.
4 core 6 sq. mm.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size cables in the existing RCC/ HUME/ Stoneware/ Metal pipe as required Upto 35 sq. mm
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade. 3.1/2 core 35sq. mm.
4core 16sq. mm.
4 core 10sq. mm.
4 core 6sq. mm.
415V LT PANELS & DISTRIBUTION BOARDS Incoming 1 No. 100. Amps 4 Pole MCCB and ON/OFF/Trip & shunt trip coil. Digital energy meter (conzerve – EM 6400NG with RS-485 or equivalent) of accuracy class-I, with 3 Nos. 120/5 amps 15VA CTs. Phase indicating light shall be protected by suitable rating MCB’s.- 3 Sets Breaker ON / OFF / TRIP indicating lights with control MCB’s. - 1 Set Bus Bars 300 amps 4P Copper bus bars with colour coded heat shrinkable insulating sleeves - 1 Set. Outgoing 1 No. 63 Amps TPN Pole MCCB and ON/OFF/Trip 6 No.63 Amps FP Pole MCB. Panel as described above.
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal or coke and salt).
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
Supplying and laying 25 mm X 6 mm G.t. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.l. nut bolt & spring washer spaced at 50 mm)
Supplying and laying 25 mm X 5 mm G.l. strip in 40 mm dia G.l. pipe from earth electrode, including connection with G.l. nut, bolt, spring, washer excavation and refilling etc. as req uired.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
LIGHTNING PROTECTION Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having singte prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.
Providing and laying coppertape 32 mm X 6 mm from earth electrode directly in ground as required,
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
SUPPLY AND INSTALLATION OF LIGHT FIXTURES AND EXHAUST FANS Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 45W LED STREET LIGHT
Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required. 50/60W LED FLOOD LIGHT
Supplying and fixing Recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 10/12w LED RECESSED ROUND DOWNLIGHT
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 10/12 W LED ROUND SURFACE DOWNLIGHT STAIR LIGHT
Supplying and fixing replaceable compact commercial batten suitable for Single TB LED tube complete with 22 watt LED polycarbonate TB tube with built in driver etc. directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
SITC of following ratings LED Post top lamp made in dia cast aluminium housing with decorative clear/ opal acrylic diffuse on existing pipe including connection with 1.5sq mm copper conductor etc all complete as required. 20/25W LED post top lamp clear
LED strip light 24 volts DC with IP 65 rated in different colours of length 5 mtr and power 5 W per meter including driver IS: 10322 pert 5/ section-7.
Supply of LED Mirror Light with power 8/10W rated voltage 230V 50 Hz aluminium/ PC body with rauuning life minimum 30000 Hours
FansSupply insttalation , testing and commisioning of following size ceiling fan 3 balde confirming to IS : 374:2019 incuding wiring thedown roads of standed lenth ( upto 30 cm ) with 1.5 sqmm PR PVC, insulated copper wire suitable for 230V 50Hz single phase supply etc. compleyte as required. 1200mm (48 Degree)
Supply and fixing of step type electronic fan regulator on existing modular plate switch box including connection but excluding modular plate etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supply of 12" (300mm) metal exhaust fan
INTERNAL WIRING AND FINAL DISTRIBUTION BOARDS Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with modular switch ,modular plate ,suitable GI box as required Group - C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. S.P 5/6 amps, one way modular switch, ISI Marked
S.P 15/16 amps, one way modular switch, ISI Marked
5 pin 5/6 amps, modular socket Outlet, ISI Marked
6 pin 15/16 amps, modular socket Outlet, ISI Marked
6 pin 15/16 ampsSupplying and fixing following size/ modules, Gl box along with modular base and cover plate for modular switches in recess etc as required., modular socket Outlet, ISI Marked 1 or 2 Module (75mm X 75mm)
3 Module (100mm X 75mm)
DB SUBMAIN WIRING IN STEEL CONDUITS Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre
2 X 4 sq. mm + 1 X 4 sq. mm earth wire Metre
2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre
4 X 6 sq. mm + 2 X 6 sq. mm earth wire Metre
4 X 10 sq. mm + 2 X 6 sq. mm earth wire Metre
4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre
POWER SOCKETS Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection, painting etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.
FINAL DISTIRIBUTION BOARD Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6/32 SP
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. 16/25 Amps
PLUMBING/SANITARY WORKS Providing and fixing 15 mm dia and 45 cm. long P. V .C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of E/l .
Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l. (b) C.I. body brass spindle
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l. (a) Mirrors of 6 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirror B(1)600x450 mm size
C(2) C.P brass liquid shop container
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (B)12.5 lit. low level PVC cistern
Making holes in wall for laying H.C.I, pipe and restoring the same after pipe laying as per specification and direction of E/l. (i) 125 mm dia
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing white vitreous china battery based infrared sensor operated urinal of appx.size 610x390x370mm having pre & post flushing with water (250ml & 500ml consumption) having water inlet from back side,including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
40 mm dia
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion. 110mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion. Coupler 110 mm dia
Single Tee with door 110x110x110 mm
Bend 87.5 deg 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised- PVC pipe clip of approved desing to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwes with M.S. Screw of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse sand ) and making good the wall etc. complete.110mm dia
Providing and fixing C.P. bass angle valve of approved quality conforming to I.S:8931.15 mm nominal bore
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter
250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter
250 mm diameter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc. complete. 150 mm. dia. RCC Pipes
300 mm. dia. RCC Pipes
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing square mouth SW gully trap class SP-1 complete CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.7 kg. as per standard design. 100x100mm size P type With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. White vitreous china wash basin size 630 mm x 450 mm with a single 15mm CP brass pillar tap.
Constructing brick masonry road gully chamber 50 X 45 X 60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500 X 450 mm precast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing fixing, testing and commissioning in position SWR PVC PIPE TYPE-B pipe comforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offests, cowl, access pieces/clean out plugs, clamps /supports/ hangers etc. jointing with PVC Adhesive joints including cutting holes in walls, core cutting in slabs and making good the same. all complete as per specification and direction of E/l. (a) 150 mm dia
(c) 100 mm dia
(e) 50 mm dia
Providing & fixing in position uPVC P"or S" trap of self cleaning design of following sizes for the embedded areas. Making proper connection with drip-seal joints, cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. 3 x 50 mm inlet and 100 mm outlet (Multi Floor Trap)
Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge. (Make: Jaquar, Hand Shower (Health Faucet) ALD-CHR-573 )
Providing & fixing chinaware urinal partition of 160X 400X 825 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required (Make: Parryware, white C0507 Large or equivalent)
Providing and fixing C.P. brass twin coat hooks fixed on toilet door with including CP brass screws, washers rawl plugh etc. complete in all respact. (Make: Jaquar, ACN-SSF-1161N)
Providing & fixing horizontal centrifugal pumps for domestic water lifting with CI casing bronze impeller suitable for operation on 400 / 440 V pH 50 cycle A/C power supply.Cost shall include electrical control panel (star/dol starter) with all controls to make the pumps to operate automaticaly.Sequencing shall be provided for the pumps.Pumps shall start /stop automatically depanding upon water level in overhead tank.(for Residencial Buildings) Domestic water Pumps inlet with Panel Location - Transfer pump to Terrace ' Capacity 2 LPS each ' Head 20 Mts RPM 2900 HP(appx) - 1.5 Pumps & associated works as described above
Providing and fixing forged brass auto air vent valve PN10 (10.00 Kg/cm2) rating including all fitting with ball valve & accessories. 15 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 25 mm nominal outer dia pipes.
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 32 mm nominal outer dia pipes.
Fixing water meter and stop cock in G.I pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),i/c necessary excavation foundation concrete 1:5:10 (1 Cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 Cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (i) Domestic tank
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 grams with threaded end for hose connection.
Providing and fixing gun metal non- return valve of approved quality (screwed end). 50 mm dia nominal bore-vertical
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore
Carriage of matarials Bricks - 30 km
Sand - 20 km
Stone Chips - 18 km
ADD @ 18 % GST
ADD @ 1 % Labour Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
SBDVENDING26.pdf
Tender Documents • 0.99 MB
BOQ_146701.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid