Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹36.9 L+₹3.5 L (10.6%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-Finance BEING NOT L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
22 Nov 2022, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
SPECIAL REPAIR TO FIRE ALARM SYSTEM AND PROVN OF OVER HEAD WATER FILLING POINT NEAR ASD 30 AT AF STATION OJHAR
2022_MES_559571_1
8906/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹82,000
Yes
19 Dec 2022
22 Oct 2022
24 Nov 2022
24 Oct 2022
22 Nov 2022
10 Nov 2022
Amount
Supply, Installation Testing & Commissioning in repair ot microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity from 2 loops to8 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have thee capablity to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall havea capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of |minimum 10,000 events1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 Inputs controlling& 20,000 Controling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 Inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs vla optlonal RS485 cOMMS serially connected expansion cards. The Panel shali have 240 V AC power supply along8 fully expandable via comman plug in loop driver boards. The user shall have a cholce of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4, The Panel shall have configurable via USB port to PC or memory stick. The Panel shail have dedicated RS232 serlal port for optlonal printer. Approved by LPCB. Model- Latitude 2LKS Make: Hochiki/LST/ESP Note: Old unserviciable obtained from item no 1 to 28 to be deposited to MES store AGE E/M Ojhar, cost of taking down and trasnporting to store deemed to be included in the quoted rate.
Supply, Instalation, Testling and Commissioning in repair of Network Module. The Module shall connect Panels and Repeator Panels through RS485. The Module shall use RS485 data at a Baud rate of 115200 Bauds. The Network Module must be configured Master/Slave, Multiple Master/ slave and TPeer to Peernetworking. Model- Network Module HOCHIKI
Supply, Installation Testing & Commisslonlng in repair of lntrinsicaly Safe Corventional Rate of Rise Heat detector features, Twin LEDS allow 360 degree vewing, Electsonics free mouting base, remote indicator output, ATEX classification I 1G EEx ia lIC T5 Tamb = 55 degree, Suitable for installation in areas at Category 1 (inc all lower 4 categorkes). ATEX Approved
Supply, Installation Testing & Commissloning in repair of Analogue Addressable Dual Zone Module with integral Short Circuit Isolator which allow Support single independent zones Up to 60 Conventional Detectors. fully monitored for short/open circuit, Powered Externally. Addrassing via DIL switches, Approved by LPCB. Model- CHQ-DZM2-SCI HOCHIKI/LST/ESP
Addressable Conrol module Make : HOCHIKI/LST/ESP
Supply, Installation, Testing and Commissioning of Optical Beam Smoke Detector. The detector shall have 5 - 100 m range, Automatic compensation, Maximum coverage 1500m2, Automatic Signal strength adjustment, Emitter unit can be powered directly from 20ne ( or loop), Features a Latching or Non- Latching faut relay, Full line continuity options, Approved by LPCB &Vds. Model- SPC-ET HoCHOKI/LST/ ESP
Power supply 7 battery for item no 7
Supply and laying 2core X 1.5 sq mm, multi stranded copper cable, FRLS Armoured cable laid/ fixed to wall/ ceiling/ loop using proper clamps/ clips complete. Make: Plza, Polycab, Havells.
Main control panel - 2 zone, complete all as speified & as directed by Engineer-in-charge.
Junction box for smoke detectors, complete all as specified & as directed by Engineer-in-Charge.
Smoke detectors of coventional type, complete all as specified & as directed by Engineer-in-Charge.
Copper Armoured Cable, (Make -Polycab) , complete all as specified & as directed by Engineer-in-Charge.
Repair in existing Fire alarm system, Modification, Programming, Testing & Re Commissioning of microprocessor based Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have two loop capacity. The Panel must also have the |capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel must have 4 inbuilt| programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54- 4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated R5232 serial port for optional printer.Existing Make Of Panel: Seimens
Supply and fix in repair in replacement Analog Addressable photo electric smoke detectors with mounting base complete ( Confir ms to EN 54. ) Approved by LPCB.
Supply & fix in repair 12 V 7 AH Battery complete all as specified and directed. Make Exide /Amaron/Panasonic.
Supply, Installation Testing & Commissioning in repair of Analogue Addresable Manual Call Point with Analogue Addressable Protocol having, Bi-coloured status LED (red for alarm, amber for (short-circuit), Non- frangible element fitted as standard (conforms to EN54), pulsing/non-pulsing.can.selestable via panel, 4 Approved by LPCB. SIEMENS/HONEYWELL
Supply and fix in repair old unservicable main circuit board addressable Fire alarm control panel complying with BSENS4/UL 2 loop panel of capacity from 126 detectors & 126 modules complete all as specified and directed. Make:- Honey well /Siemens
Supply and fix in repair old unservicable loop circuit board addressable Fire alarm control panel complying with BSENS4/UL 2 loop panel of capacity from 126 detectors & 126 modules complete all as specified and directed. Make: Honey well / Siemens
Supply and fix in repair old CPU circuit board addressable Fire alarm control panel complying with BSEN54/UL 2 loop panel of capacity from 126 detectors & 126 modules complete all as specified and| directed. Make: Honey well / Siemens
Supply and fix In repair old unsevicable Display and Keys circuit board of addressable Fire alarm control panel complying with BSEN54/UL 2 loop panel of capacity from 126 detectors & 126 modules| complete all as specified and directed. Make: Honey well/ Siemens
Supply and fix in repair laying 2Core x 1.5 Sq.mm, Multistranded Copper cable, FRLS Armoured cable laid / fixed to wall/ celing/ loop using proper clamps/ clips complete. Make: Plaza/ Polycab/ Havells
Supply and Fix in repair of Control module Make: Siemens/Honeywell
Supply and Fix in repairof Isolator module. Make: Siemens Honeywell
Supply and Fix in repair of Monitor module Make: Siemens/Honeywell
Supply and lay pipe galvanized. “Heavy class”, including fittings 150 mm (6”) dia as specified and as directed by engineer-in-charge.
Supply and fix Sluice valves (Brass insert) of 150 mm bore, as specified and as directed by engineer-in-charge.
Supply and fix foot valves of 150 mm bore, as specified and as directed by engineer-in-charge.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out soft/loose type soil complete all as directed.
Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm complete all as directed..
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Supply, install, Testing & Commissioning of self primimg bare shaft pump of 15 KW, 20 HP suc X dis 150 X 150 mm with a head of 10 to 25 Mtrs at 15 Mtrs it should have a discharge of 3450 LPM. Impeller, motor body, delivery casing made of CI & shaft SS, Shaft sleeve SS, Sealing gland packed including starter of make Kirloskar or equivalent, completete all as specified & as directed by Engineer-in-charge.
Cement concrete in foundations, filling and mass type B2 1:2:4 of 40 mm aggregate, complete all as specified and as directed by the Engineer-in-charge.
Cement concrete in foundations, filling and mass type B2 1:4:8 of 40 mm aggregate, complete all as specified and as directed by the Engineer-in-charge.
Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes in soft/loose soil and getting out, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Boring of holes under road,, pavement , hard standing by trenchless technology using ultra sounding technique and necessary machine ncluding HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply, laying and testing cable XLPE insulated, pvc bedded, gaalvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as speified & as directed by the Engineer-in-Charge.
Supply & laying double wall corrugated (DWC) duct (dura guard) of size 38 mm inner dia and 50 mm outer dia as per IS 14930 part II as in LT UG cable protection including coupler, elbows, T joints, Bends etc., and test reports all as specified and as directed Make: Dura-line, Gemini, Rex
Rolled mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in cluding cleats, brackets, weling, cutting, nut bolts as required at site etc. complete all as specified & as directed by the Engineer-in-Charge.
shakti engineering and electrical works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .