Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 CrAccepted-AOC E 7 HIG 497 ARERA COLONY BHOPAL 16 M P | BHOPAL | BHOPAL | MADHYA PRADESH | 462016 | ₹32.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹33.6 CrRejected-AOC | ₹33.6 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹35.0 CrRejected-Finance PLOT NO 3 YOGANAND CO OP HOUSING SOCIETY BEHIND BIJAN HOSPITAL NEAR MALPANNI HOSPITAL VIGHA MALA CANADA CORNER COLLEGE ROAD NASHIK | NASHIK | NASHIK | MAHARASHTRA | ₹35.0 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹35.8 CrRejected-Finance | ₹35.8 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹35.9 CrRejected-Finance | ₹35.9 Cr | L5 | Rejected-Finance L5 |
Tender Value
₹37.5 Cr
EMD Value
₹18.7 L
Closing Date
22 Jul 2025, 6:00 pmClosed
Executive Engineer
Executive Engineer EGS. (Works) Division, Ahilyanagar Bandhakam Bhawan Chh. Sambhajinagar Road Ahilyanagar-414003
Construction of New Court Building (Ground and 3 Floors) (5 Court Halls) at Newasa Tal. Newasa Dist Ahilyangar
2025_PWR_1198368_1
E-TENDER NOTICE NO. 2 for 2025-26 IInd Call
Open Tender
Civil Works - Buildings
730 days
Newasa
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,540
₹18.7 L
Chief Engineer, Public Works Region, Nashik
24 Dec 2025
8 Jul 2025
23 Jul 2025
8 Jul 2025
22 Jul 2025
8 Jul 2025
14 Jul 2025
Amount
Civil work as per NIT GF FF SF TF
Empty boring for 425 to 500 millimetre diametre bored Reinforced Cement Concrete cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete.
Empty boring for 525 to 600 millimetre diametre bored Reinforced Cement Concrete cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete.
Providing bentonite slurry process for various diameter of piles vide Item Nos 1 (i to xxiv) above.
Chiseling through pile shells in hard strata like boulders, soft and hard rocks Upto and inclusive of 550 millimetre diameter including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete.
Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 550 millimetre and upto and inclusive of 750 millimetre diametre including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete.
Providing and laying cast in situ / Ready Mix Cement Concrete Mix-30 for bored piles each of load capacity and as per design and of 500 millimetre diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based Programmble Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
Providing and laying cast in situ / Ready Mix Cement Concrete Mix-30 for bored piles each of load capacity and as per design and of 600 millimetre diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based Programmble Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
Chipping and dressing of the Reinforced Cement Concrete piles upto 0.60 meter including cleaning reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the building area etc. for providing pile caps.
Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 550 millimetre and upto 650 millimetre diameter including construction of test cap, use of accessories and instruments including providing graphs as per Indian Standard code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.
Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 650 millimetre and upto 750 millimetre diameter including construction of test cap, use of accessories and instruments including providing graphs as per Indian Standard code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre) By Mechanical Means
Providing preconstructional antitermite treatment as per Indian standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Inadian Standard 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 Cement Mortar diametre about 30 -60 centimetre deep at 15 centimetre centre to centre as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
Providing and laying Plain Cement Concrete in Mix 15 grade levelling course of 100 millimetre thick below pile cap with fully automatic micro processor Programmable Logic Controller with Supervisory Control And Data Aqusition enabled reversible drum type mixer/ concrete batch mix plant (pan mixer) etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap metal for Reinforced Cement Concrete pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Aqusition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Imapcted Grade) complete (Excluding steel reinforcement)
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete in Mix 15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based Programabble Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade) for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and laying Cast in situ/Ready Mixcement concrete Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite/granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with Cement Mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre x 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180x100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of in foundaions and plinth of inner walls/in plinth external walls including bailing out water,striking joints on unexposed faces,racking out joints on exposed faces and watering etc.complete
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to Indian Standard : 6441 (Part I) - 1972)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to Indian Standard:6441 (Part I) - 1972)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing water proof bedding for flooring of Bath and Water Closet 25 millimetre thick in Cement Mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing waterproof plaster in Water Closet and bath 20 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing patti/ band 75 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortar 1:3 line and level including neat finishing scaffolding curing etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing patti/ band 100 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortar 1:3 line and level including neat finishing scaffolding curing etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing internal cement plaster 20 millimetre thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete.
Providing and applying plaster with plaster of paris in 6 millimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
for fifth floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diametre and vertical pipe of 38 millimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fifth floor
Providing and fixing in position aluminium color anodized fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 millimetre thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fifth floor
Supplying and fixing in position Colour anodized Aluminium four track sliding windows with outer frame made from section of over all size 122 millimetre x 45 millimetre, bottom section with drain section track weighing 1.83Kilogramper metre and top and side section of size 122x 31.75 millimetre weighing 1.15Kilogramper One Running Metre with shutter sections made of 18 millimetre x 40 millimetre size having average weight of 0.6Kilogramper One Running Metre (or as required size) with change in proportionate weight, with 6 millimetre float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Door Frame: Supplying frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram / cubic metre) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per Indian Standard:401and kiln seasoned to moisture below 15% as per Indian Standard:1141 of section 120 X 60 millimetre spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimetre x 4 millimetre affixed in the slit of the Frame for fire and smoke sealing, etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Shutter : Providing of 65 millimetre thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes Indian Standard 3614 part -II comprising of 2x9 millimetre Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per Indian Standard:401and kiln seasoned to moisture below 15% as per Indian Standard:1141 frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128Kilograms/CMT), vermaculite mix faced with 6 millimetre Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10 millimetre x 4 millimetre concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre x 40 millimetre x 5 millimetre with oil painting, etc. complete for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35 millimetre thick style and rail with 25 millimetre thick panels with openable fan light as per detailed drawings. Excluding the door frame 60 millimetre x 100 millimetre stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame)for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. On cenitmetre 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing fiber glass reinforced polyster door shutter 35 millimetre thick as per Indian Standard 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one number stainless steel 304 hinged rail 76 centimetre & three number stainless steel 304of (Grab Bar) 60 centimetre all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-chargefor First Floor
for Second Floor
for Third floor
Providing and fixing ISI marked double swing flush door shutters conforming to Indian Standard :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimetre thick including ISI marked Stainless Steel L- hinges with necessary screws Fittings & Fixtures per leaf stainless steel kick plates on both sides of the door of 300 millimetre height Heavy Duty satin finish butt Stainless Steel Hinges (100 millimetre x 75 millimetre x 3 millimetre in size) -4 umber. Stainless Steel finished lever handle with mortise lock- 1 One Number Floor spring- 1 One Number 100 millimetre x 100 millimetre safety glass at the specified location for First Floor
for Second Floor
for Third floor
Grab bars-Providing Stainless steel grab bars set for accessible toilets comprising of 4 number Grab bars as specified below.(1 number wing grab bar + 1 number L shaped grab bar + 2 number straight grab bars = 1 typical set) 27a) Swing grab bar (1 number) Providing a stainless steel 304 SWING HANDICAP GRAB BAR - 700 millimetre and of DIAMETRE: 32 millimetre and thickness 1.5 millimetre of the roved brand and make. 27b) L Shaped grab bar (1 number) Providing stainless steel 304 L SHAPED DISABLED GRAB BAR of SIZE-600 millimetre (H) X 600 millimetre (D) and 32 millimetre DIAMETRE. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 number) Providing stainless steel 304 GRAB RAIL (600 millimetre),32 millimetre DIAMETRE and thickness 1.5 millimetre of the approved brand and makefor First Floor
for Second Floor
for Third floor
Providing and laying in situ cement concrete Mix 20 with tremix treatment for 100 millimetre thickness for flooring with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen etc. complete.
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 millimetre thickness of having a strength of 400 Kilogram / Square centimetre of approved quality and shape on a bed of crushed sand of 25 to 30 millimetre thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)
Providing and laying handcut polished Kotah Stone flooring 25 millimetre to 30 millimetre thick and 30 centimetre wide in plain/diamond pattern on a bed of 1:6 Cement Mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooringfor Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimetre to 30 millimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in centi metre 1:3 curing and cleaning etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying vitrified matt finish tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying matt finish ceramic tiles of having size 30 centimetre x 30 centimetre confirming to indian standard 15622/2006 (group D II-A) and 7 to 8 millimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding Indian standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
Providing and laying in place 300 millimetre x 300 millimetre x 9.8 millimetre vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Directional signage - Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6 inch x 9 inch designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15 millimetre raised not less than 0.8 millimetre above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15 millimetre raised not less than 0.8 millimetre above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200 millimetre from FFL and as per the directions by the engineer in charge.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessaryfor Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6 millimetre thickness or Tape Grooves 35 to 45 millimetre thickness or as required, in all position including preparing the surface, scaffolding etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Chrome Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing 20 millimetre diametre screw down bib/ stop tap of brass including necessary socket union nut complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing screw down for 20 millimetre diametre wheeled stop tap of brass including necessary sockets/union nut complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying concrete pipes of Indian Standard Non Pressure class of 225 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of Indian Standard Non Pressure class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipe, Brick Masonry, plastering from inside and airtight Cast Iron cover of 75 Kilogram with lid and frame fixed in cement concrete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware Pipes, Brick Masonry, plastering from inside and Cast Iron lid cover of 75 Kilogram with lid and frame fixed in cement concrete.
Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing 75 millimetre diametre stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing 100 millimetre diametre stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing on walls/ ceiling/ floor 15 millimetre diametre Chlorinated Polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing on walls/ ceiling/ floor 20 millimetre diametre Chlorinated Polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing on walls/ ceiling/ floor 25 millimetre diametre Chlorinated Polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing on walls/ ceiling/ floor 40 millimetre diametre Chlorinated Polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing on walls/ ceiling/ floor millimetre diametre Chlorinated Polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing 10 centimetre Poly Vinyl Chloride nahani trap with grating etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and laying in trenches 50 millimetre diametre heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimetre diametre 1.2 millimetre thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimetre diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimetre thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimetre diametre 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Providing and fixing copper strip 25 millimetre wide and 3 millimetre thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthinf pits is not considered in this item for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 centimetre x 45 centimetre size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including Poly Vinyl Chloride waste pipe and trap up to the outside face of the wall. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 millimetre size with pillar cock, Chrome plated Angular stop cock, long thread of approved make continental including stainless steel bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 millimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing orissa type colour glazed earthenware 625 x 450 millimetre water closet pan including trap, Cast Iron soil and vent pipe upto the out side face of wall including 100 millimetre diametre Cast Iron plug, bend, 15 millimetre thick 10 litre Poly Vinyl Chloride flushing cistern with all necessary pipe connection etc. complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing white Opal series European type wall-hung, of size 400 millimetre x 370 millimetre x 575 millimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 millimetre diametre Cast Iron plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete for Ground Floor.
for First Floor
for Second Floor
for Third floor
for fourth floor
Boring/drilling bore well of 300 millimetre diametre for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized Poly Vinyl Chloride medium well-casing pipe of 150 millimetre diametre conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.
Providing and fixing Mild Steel grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Square metre) Spec.One Number: As directed by Engineer- in-charge.
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and laying perforated Poly Vinyl Chloride 160 millimetre diametre pipe in proper line,leveland slope including necessary material fitting etc. complete.
Providing and laying of filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600 millimetre with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition as per drawing and technical specifications etc. complete.
Providing cast in situ / ready mix Mix 20 grade cement concrete for head walls of Cross Drainage work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with Supervisory Control And Data Acquisition
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete.
Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate up to 4.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make with Poly Vinyl Chloride waste pipe with fitting arrangement etc.complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Vinyl CHloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimetre diametre Poly Vinyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing white glazed urinal of size 710x460x300 millimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetre diameter Poly Vinyl Chloride flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 metre x 0.60 metre and height is 0.75 metre)for Ground Floor
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 16 millimetre thick of 1200 millimetre (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval The 16 millimetre thick panels shall be used for a roofing height of upto 15 metre.
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. for Ground Floor
for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimetre with lock plate of 3.15 millimetre thickness reinforced with 35 x 35 x 5 millimetre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 millimetre and 3.15 millimetre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 millimetre minimum size and shape with square bar, suspension shaft of minimum 32 millimetre diameter, hood cover of Mild Steel sheet not less than 0.9 millimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear)
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Verticle Shaft Impacted Grade)
Providing second class Burnt Brick masonry with conventional/ Indian standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing and fixing wall panelling 12 millimetre thick commercial Gurjan plywood covered with 1 millimetre with laminate of approved colour over frame work of 12 millimetre thick commercial Gurjan plywood including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Judge's table in Court Hall of size 2.13 x 0.84 x 0.84 = 1 Number with frame work with 18 millimetre thick commercial Gurjan plywood & 6 millimetre thick commercial Gurjan plywood all exposed surfaces (except front & sides) masked by Steno & Clerk's tables) covered with 1 mm. laminate of approved colour & top provided with 12 millimetre thick clear glass over red velvet cloth bordered with Teak wood moulding 100 x 25 millimetre melamine polish & melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing foot rest of size 0.78 x 0.78 x 0.10 = 1 Number for Judge's table of 12 millimetre thick commercial Gurjan plywood frame work fitted with 1 millimetre laminate on exterior surfaces & french polish to internal surfaces & including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Steno table in Court Hall of size 1.22 x 0.55 x 0.76 = 1 Number with frame work with 18 millimetre thick commercial Gurjan plywood & 6 millimetre thick commercial Gurjan plywood all exposed surfaces (except front & sides masked by Judge's table & partition) covered with 1 millimetre laminate of approved colour, melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing and fixing Clerk table in Court Hall of size 1.72 x 0.55 x 0.76 = 1 Number with frame work with 18 millimetre thick commercial Gurjan plywood & 6 millimetre thick commercial Gurjan plywood all exposed surfaces (except front & sides masked by Judge's table & partition) covered with 1 millimetre laminate of approved colour, melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing and fixing foot rest of size 0.78 x 0.50 x 0.10 = 1 Number for Judge's table of 12 millimetre thick commercial Gurjan plywood frame work fitted with 1 millimetre laminate on exterior surfaces & french polish to internal surfaces & including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Judge's partition with side gates in Court Hall of size 4.26 x 1.65 of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate fitted on exterior surfaces & teak wood balusters & Teak wood ball for decoration, Teak wood balusters 0.07 x 0.07 x 0.60 & moulding on railing top polished in mirror finish melamine polish including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing and fixing Advocate Court table in Court Hall of size 2.70 x 0.90 x 0.76 = 1 Number of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces & fitting with decorative Teak wood balusters in the front corners including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Writing desk of size 0.53 x 0.46 x 0.30 = 1 Number of 18 millimetre thick commercial Gurjan plywood fitted with top in 12 millimetre commercial Gurjan plywood fitted with laminate of approved colour on exterior surfaces & 30 x 30 x 100 millimetre Teak wood legs to be placed on Advocate Court table including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Witness Box size 0.90 x 0.90 x 1.20 = 1 Number in Court Hall in 18 millimetre thick commercial Gurjan ply fixed fitted with 1 millimetre laminate of approved colour & Teak wood balusters & decorative Teak Wood ball over pillars & Teak wood moulding melamine polish over railing & provided with folding flap of 18 millimetre commercial Gurjan ply & Stainless steel window stay hooks 230 millimetre & Stainless steel hinges including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing partition of thickness 0.11 metre for Defendant's Enclosure with side gate in Court Hall of size 4.60 x 1.21 + 1.18 x 1.21 of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces & Teak wood balusters & Teak wood balla & Teak wood moulding melamine polished including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Bench of size 4.43 x 0.40 x 0.46 = 1 Number. in Defendant's Enclosure in Court Hall of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Judge's table in Chamber of size 2.13 x 0.79 x 0.76 = 1 Number with frame work with 18 millimetre thick commercial Gurjan plywood & 6 millimetre thick commercial Gurjan plywood all exposed surfaces (except front & sides) masked by Steno & Clerk's tables) covered with 1 millimetre laminate of approved colour & top provided with 12 millimetre thick clear glass over red velvet cloth bordered with Teak wood moulding 100 x 25 millimetre melamine polish & melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Back Runner of size 2.54 x 0.41 x 0.76 = 1 Number for Judge's table in Chamber of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Side Drawer of size 0.90 x 0.41 x 1.90 = 1 Number for Judge's table in Chamber of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Full height storage of size 1.18 x 2.32 x 0.60 = 1 Number. in Judge's Chamber with frame work in 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces & back in 12 millimetre thick commercial Gurjan ply & 1 shutter in aluminium profile section with 5 millimetre plain glass including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Steno table of size 1.63 x 0.69 x 0.76 = 1 No. in Judge's Chamber waiting with frame work with 18 mm. thick commercial Gurjan plywood & 6 mm. thick commercial Gurjan plywood all exposed surfaces covered with 1 mm. laminate of approved colour, melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Clerk table of size 1.21 x 0.61 x 0.76 = 1Number. in Judge's Chamber waiting with frame work with 18 millimetre thick commercial Gurjan plywood & 6 millimetre thick commercial Gurjan plywood all exposed surfaces covered with 1 millimetre laminate of approved colour, melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing Dining table in Ante room of Judge's Chamer of size 1.20 x 0.75x 0.76 = 1 Number of rubber wood with & melamine polish complete as per instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing and fixing Notice Board outside of Court Hall of size 1.22 x 1.22 x 0.20 with 1 millimetre laminate on external surfaces & 5 millimetre plain glass with handles & lock, soft board and blazer cloth fixed on the inside back etc. including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Bar table of size 1.20 x 0.75 x 0.76 = 1 Number in Bar Room of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour & melamine polish to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Staff table with side runner of size 1.50 x 0.69 x 0.76 + 0.90 x 0.41 x 0.76 = 1 Number of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour, melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Senior Staff table of size 1.80 x 0.69 x 0.76 + 0.90 x 0.41 x 0.76 = 1 Number with side runner of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces, melamine to all exposed lipping patti & French polish to all internal surfaces of drawers & cabinet including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Judge's reading table of size 2.10 x 0.90 x 0.76 = 1 Number. in Library of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces & Melamine polish to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Judge's Meeting hall table of size 4.27 x 0.75 x 0.76 = 1 Number of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces & Melamine polish to exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in chargefor fourth floor
Providing and fixing Staff table ST-1 for Bailif & other staff of size 1.21 x 0.69 x 0.76 = 1 Number of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces with Melamine polish to exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Staff table ST-2 of size 1.80 x 0.60 x 0.76 = 1 Number for Male & Female Witness room & other staff of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces with Melamine polish to exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing and fixing Bar typist table - 3 seater of size 2.45 x 0.69 x 0.76 = 1 Number of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
Providing and fixing Bar typist table - 4 seater of size 3.23 x 0.69 x 0.76 = 1 Number of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
Providing and fixing computer table in computer branch of size 0.90 x 0.60 x 0.91 = 1 Number of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Meeting table of size 4.27 x 0.90 x 0.76 = 1 Number in Officer's room of 18 millimetre thick commercial Gurjan ply with 1 millimetre termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing and fixing Conference table of size 2.90 x 1.40 x 0.76 = 1 Number in DLSA room of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in chargefor fourth floor
Providing and fixing Full height/Low height storage of size 2.00 x 0.47 x 2.44 in various branches of 18 millimetre thick commercial Gurjan ply & 12 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour fitted on exterior surfaces including surface termite treatment to all plywood, necessary hardware, labour etc. complete as per design & drawing as directed Architect's Drawing & instructions of Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing Judges chair of overall size 0.60 x 0.50 x 1.15 made in Burma teak wood at bottom teak wood support of size 80 x 80 millimetre are hand rest is to be provided cushion back rest and melamine polish for teak wood frame and seat & back rest in 50 millimetre thick high desity foam as per instructions of Engineer in charge & as per sample.for First Floor
for Second Floor
for Third floor
Providing Executive chair high back for Judges with powder coating of approved company with five legged moulded nylon base and push back arrangement, chair shall be with high density foam for optimum seating comfort 360° revolving on suitable base adjustment and heavy duty castor wheels to take minimum 80 kilogram per castor wheel with moulded type PU arm rest the chair shall be provided with approved type wherever required as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing Executive chair medium back for Judicial Officer & Senior staff with powder coating of approved company with five legged moulded nylon base and push back arrangement, chair shall be with high density foam for optimum seating comfort 360° revolving on suitable base adjustment and heavy duty castor wheels to take minimum 80 Kilogram per castor wheel with moulded type PU arm rest the chair shall be provided with approved type wherever required as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing chair low back for staff with powder coating of approved company with five legged moulded nylon base and push back arrangement, chair shall be with high density foam for optimum seating comfort 360° revolving on suitable base adjustment and heavy duty castor wheels to take minimum 80 Kilogram per castor wheel with moulded type PU arm rest the chair shall be provided with approved type wherever required as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing Mild Steel perforated multi three seater with heavy duty stand Mild Steel perforated sheet with powder coated for seat and back with separate PU handle for each seal etc. complete as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing Mild Steel perforated multi two seater with heavy duty stand Mild Steel perforated sheet with powder coated for seat and back with separate PU handle for each seal etc. complete as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing chair high back for Judge's on dias in Meeting Hall with cushion seat back and PU handles of approved company with four legs, chair shall be provided with approved type wherever required as approved by Engineer in chargefor fourth floor
Providing Bench of size 1.50 x 0.45 x 0.45 made out of Mild Steel pipe powder coated finish with 18 millimetre thick commercial Gurjan plywood and 1 millimetre thick laminate of approved colour as per instructions by Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing low back chair in Mild Steel pipe frame with powder coating & seat and back in powder coated perforated Mild Steel sheet with P.U. arm rest as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing low back chair in Chrome plated pipe legs and moulded frame seat and back as visitors chairs, library, mini conference as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
Providing low back chair in P.C. pipe frame & perforated powder coated Mild Steel sheet with cushioned seat and back and folding flap in 18 millimetre plywood with laminate as chair in Meeting Hall as approved by Engineer in chargefor First Floor
for Second Floor
for Third floor
Providing Book Shelf Rack of size 0.86 x 030 x 1.82 = 1 Number in Mild Steel sheet with partly glass shutters with locking arragement duly spray painted of approved colour as approved by Engineer in charge.for First Floor
for Second Floor
for Third floor
for fourth floor
Providing and fixing Canteen table of size 1.20 x 0.75 x 0.76 = 1 Number with top of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour & Teak wood moulding on edges fitted on frame of 35 x 35 x 5 millimetre Mild Steel angle over stand of 35 millimetre Mild Steel square pipe painted in enamel paint & fitted with rubber bushes for the legs as approved by Engineer in charge for First Floor
for Third floor
Providing and fixing Canteen table of size 0.60 x 0.60 x 0.76 = 1 Number. with top of 18 millimetre thick commercial Gurjan ply with 1 millimetre laminate of approved colour & Teak Wood moulding on edges fitted on frame of 35 x 35 x 5 millimetre Mild Steel angle over stand of 35 millimetre Mild Steel square pipe painted in enamel paint & fitted with rubber bushes for the legs as approved by Engineer in charge. for First Floor
for Third floor
Providing Judges chair of overall size 0.60 x 0.50 x 1.15 made in Teak wood at bottom teak wood support of size 80 x 80 millimetre are hand rest is to be provided cushion back rest and melamine polish for teak wood frame and seat & back rest in 50 millimetre thick high desity foam as per instructions of Engineer in charge & as per sample.for First Floor
for Second Floor
for Third floor
Providing Dining Chairs in Ante room of Judge's Chamber of size 0.43x0.48x0.89 of rubber wood with cushioned seat & back & melamine polish complete as per instructions of Engineer in charge. for First Floor
for Second Floor
for Third floor
Providing low back chair in Chrome Plated pipe frame & cusioned seat and back as visitors chairs, library, mini conference as approved by Engineer in charge. for First Floor
for Second Floor
for Third floor
for fourth floor
Providing steel store wells 0.92 x 0.50 x1.98= as approved by Engineer in charge. for First Floor
for Second Floor
for Third floor
Transformer & DG Set
Providing and erecting 4 Pole MCCB 415V 250A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-3]
Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB. [5-11-18]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-21]
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(UE) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT [7-3-9]
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-1]
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT [7-5-5]
Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4]
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete. [7-6-6]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-11]
Supplying and erecting inline D. P. Structure for 11/0.415 kV 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set L.A. A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps Nut-bolts. V cross arm top clip insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. [8-3-20]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-2]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. [9-2-5]
Supplying, installing, testing and commissioning of 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50 ? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.[10-1-5]
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG [10-6-18]
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. [10-6-19]
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD [10-6-20]
Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22]
Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10-6-24]
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25]
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 17.4 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG [11-1-12]
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 82.5 kVA up to 100 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF. [11-2-10]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11]
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5]
second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1 6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually striking joints on unexposed faces raking out joints on exposed faces and watering etc. Complete. [16-2-1]
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. [16-2-3]
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). [16-2-4]
Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). [16-3-7]
Internal Electrical Installation
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type buzzer 220 / 250V duly erected on provided plate and box with wiring connections complete. [1-6-19]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-38]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40]
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15]
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-16]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2]
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 1500 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-4]
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7]
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22]
Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. [2-3-15]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. [2-11-3]
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22 [3-3-9]
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1]
Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3]
Supplying, installing, testing and commissioning of 6kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-4]
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete [3-8-8]
Supplying and erecting 12V/26Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-9]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-2]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9]
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-16]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying and erecting 100 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-5]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-16]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-20]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-21]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-6]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-2]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1]
L.V. System
Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete. [1-6-14]
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. [1-6-26]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1]
Supplying and erecting 10 pair 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier polythene sheathed G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW [1-8-13]
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18]
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW [1-8-19]
Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1]
Supplying, Erecting and Commissioning of 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-11]
Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18]
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. [1-9-26]
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29]
Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16]
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC [1-10-18]
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. [1-11-1]
Supplying, fixing, and configuring 24 ports POE switch in provided rack as per specification No. WG-NWC/ENS [1-11-3]
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4]
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18]
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-13]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. [2-11-4]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-13]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-9]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. [17-1-21]
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680 Kg · Floors :- G+4 floor (5 Stops/5 Landings) · Travel :- 21 mtrs· Location of Lift Machine:- MR/MRL · Rated speed :- 1.0 mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1300 .mm wide x 1350 .mm deep x 2250 mm high · Lift shaft available having clear size of 2100 mm wide x 1900 mm deep, 1500 mm Pit depth, 4500 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. and Other As per NIT
Fire Fighting
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-24]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-8]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP [13-1-4]
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP [13-2-1]
Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP [13-4-2]
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-2]
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-3]
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-4]
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5]
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6]
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-7]
Providing G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-8]
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. [13-6-10]
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS [13-7-8]
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-15]
Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-16]
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-18]
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-19]
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-20]
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-21]
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-24]
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-25]
Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-37]
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8-2]
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4]
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ [13-8-8]
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8-10]
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT [13-8-12]
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13]
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14]
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS [13-8-15]
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP [13-8-16]
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-19]
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20]
Supplying, installing, testing and commissioning of remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI [13-9-9]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10]
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 1 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.[13-10-2]
Supplying, installing, testing and commissioning of addressable optical smoke detector single/twin LED’s with 360 degree view suitable for low voltage 15 to 32 V DC two wires supply in-built locking mechanism to check the removal and pilferage of the detector in built isolation mode start up current 300µA and alarm condition current shall be maximum 6.5 mA operating temperature 0°C to 50°C humidity 0-95% RH IP 41 conforming to IS 2189 2008 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD . [13-10-6]
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors in built isolation mode suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS 2175 - 1988 reaffirmed 2000 IS 15908 2021 standards FF-AFAS/SD. [13-10-7]
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type) made of addressable break glass plastic square in shape surface/flush mounted with Break Glass massage embedded on the glass complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. [13-10-9]
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 reed relays EN 54 or UL Listed FF-AFAS/CRM [13-10-10]
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/MM [13-10-11]
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/ISM [13-10-12]
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908 2021 with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54 conforming to IS 2189 2008 IS 15908 2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. [13-10-13]
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1]
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2]
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3]
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4]
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6]
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10]
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. [13-12-1]
Supplying, erecting, testing and commissioning of vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. [13-12-2]
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). [16-3-5]
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-10]
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-11]
Supply and erecting ABC powder type fire extinguisher as per IS 13849/15683 of 6 kg capacity with necessary clamp erection on wall. [999-1-85]
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages in PVC/Vinyl 4/6mm thick sheet or as per sample approved by client viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 300mm* 100 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [999-1-86]
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 450mm* 150 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [999-1-87]
Supply & Eracting 1000 mm long 25 mm dia. Stainless steel corrugated flexible pipe (hose)nfor dropping sprinkler below false ceiling pipe shall have 16 bar rating and with union/reducer coller clamps etc. as required.(Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [999-1-88]
Supply lnstaltation testing & commisrioning of flow switches in 80/100/150 mm dia pipe with all acceslories as required. [999-1-89]
Rossette Plate powder coated in white/off white colour with 25 mm dia. Hole. (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [999-1-346]
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet outlet overflow pipe inclusive of all tanks capacity up to 20000 litres. [4-8-7]
Air Conditioner
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-6]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying 6 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply. [1-5-16]
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-10]
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC [3-2-13]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. [3-2-26]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. [3-2-27]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. [3-2-28]
Supplying, erecting, testing and commissioning of 7HP to 8HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete [3-11-2]
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. [3-11-23]
Supplying, erecting, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements fan refrigerant liquid and refrigerant piping cordless remote control and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase 230V 50Hz AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. [3-11-22]
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77]
Supplying and installing of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways Nitrile rubber insulation painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. [3-11-86]
Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size. [3-11-87]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-93]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-94]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-95]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. [4-2-9]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. [4-2-10]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. [4-2-12]
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-19]
Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. [5-3-14]
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board. [5-3-19]
Supplying and erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A 2 pin plug & earth socket and 10A 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. [5-4-10]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
CCTV System
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON. [1-2-4]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. [1-11-1]
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18]
Supplying, installing, testing and commissioning of 2kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-2]
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-10]
Supplying and erecting Supplying erecting and commisioning of 16 channel professional series 4 k HD network video/ audio IP video input 16 ch Two way audio 1 ch RCA network bandwidth 320 MBPS (i/c&OG) remote user 128 protected p2p U pup NTP DHQ video remote user 128 protected p2p U pup NTP DHQ video Audio output HDMI/VGA 1920 x 1080p/ 60 Hz 280x720/60 12 MP/8MP/6MP/5MP/108 Recording resolution Op/960p/720p/p1/2CIF all Audio output LCH RCA 16ch play back corridor mode 3/4 /5/7/9/10/12/16/3 Deced format H265 h 264 Live view play back 12 MP/8MP/6MP/5MP/4MP/3MP 30 16x 1080P 30X Hard disk sata 4s interface upto 10 TB for each serial interface 1xR4585 USB front panel 1xusb 20 Rear panel 1 ALARM 08CH A08um out 4 ch power supply 12 V PC power consumption 12W(without 10cnt (+14 fat 131F) environment Dimentious humidity 590% RH (non condensing) 440 mmx 30 mm (17.3 x 13.5 x 2.0 ) (WXDXH) (weight without hdd)< 3.14 kg (6.9216) certification with three year warrenty CE FCC UL) mAKE- HIKVISION NON CSR SANCTIONED BY S.E. MREC MUMBAI LETTER NO. 583 DT 22/02/2022 est no. 0618/2021-22) [999-1-349]
Supply and installation of 8TB surveillance storage Hard Disk Drive-24/7 Surveillance HDD capacity -8 TB interface - SATA III 6 Gb/s Max sustained Transfer Rate OD- 210 MB/s cache-256 MB Tamish Resistant load /unload cycles- 300 000 power on Hours/ year 8760 mean Time Between failures (MTBF) - 1 million hours operating Temperature- Ambient 41 F/5 C(min) Drive case 158 F/70C (max) Non operating Temperature Ambient -40 F/ -40C (min). Make - Seagate (NON CSR Sanctioned by S.E. MREC Mumbai Letter No.583 Dt.22/02/2022 Est.No.0618/2021-22 ) [999-1-350]
Supplying and erecting Supply installation and commi-ssioning of 43 full 4k Full HD commercial 4K Led Display monitor /42 inches or higher full HD VGA DVI HDMI LAN USB RGB RS 232C IN / OUT AV IN COMPONENT IN AUDIO IN/OUT WIFI READY SPEAKERS Make- Sony (NON CSR Sanctioned by S.E. MREC Mumbai Letter No.583 Dt.22/02/2022 Est.No.0618/2021-22 ) [999-1-351]
Supply Installation commissioning of 4 MP Full HD IP Dome / Bullet Camera Image Sensor 1/3 4 megapixel progressive scan CMOS Effective Pixels 2304 (H) × 1296 (V) Electronic Shutter Speed Auto/Manual 1-1/100000 s Min. Illumination 0.1 lux F2.1 (Color) 0 lux (IR LEDs on IR Distance - nUp to 100 ft (30 m) Day/Night -auto (ICR)/Color/BW Backlight Compensation - BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking- Up to 4 areas Lens Focal Length- 2.8 mm Horizontal Angle of View 92° 86°-28 Compression H.264 (Main/High/Baseline Profile) /MJPEG Resolution 3 MP (2304×1296) 1080p Main Stream 3 MP (1-20 fps) 1080p (1-25/30 fps) Corridor Mode Support Network Protocol IPv4/IPv6 HTTP HTTPS TCP/IP UDP UPnP ICMP IGMP RTSP RTP SMTP NTP DHCP DNS PPPoE DDNS FTP IP Filter QoS Compatibility -nONVIF Profile S CGI Max User Access 20 users Mobile App - for iPhone iPad Android Phone and Tablet Power Supply PoE (802.3af) 12 V DC Working Environment -22°F to 140°F (-30°C to 60°C) 10% to 100% RH condensing Ingress Protection IP66 Vandal Resistance - IK10 Regulatory FCC Part 15B Class B -(CSR Rate Approved by SE PREC Pune Vide letter No.39/2022-23 dated 20/9/2022 ) [999-1-393]
Street Light
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 6600 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-5]
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-12]
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21]
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9]
Water Pump
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying, fixing, and commissioning MCB type change over switch 4 pole 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-24]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nuts bolts etc. complete. [6-1-12]
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars 500V 100A having 15mm (Width) X 3 mm (Thickness) with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB [6-2-1]
Supplying and erecting 525 V 3 phase 50 Hz. MPP type capacitor having minimum overcurrent capacity of 1.8 In peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2 3 5 7 10 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. [6-5-3]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-1]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-2]
Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-9]
Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15]
Supplying and erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) [12-4-16]
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17]
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6]
Supplying and erecting ISI mark GI pipe 100 mm dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP. [16-5-15]
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18]
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21]
Rooftop Solar System
Supplying, installing, testing and commissioning of 20 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 60 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter proper base plate canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB MCB etc. wiring up to solar Inverter in casing and capping display board sign board two distinct earthing lightning arrester liaisoning charges remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. [4-5-5]
Supplying and installing of Solar PV Module cleaning unit consisting of nozzles spray necessary pipes valves post electronic panel board concealed with weather proof cabinet spreading water periodically for removal of dust related motor pump controller timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). [4-8-8]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010 [6-1-14]
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 3x240V 50 Hz with optical & RS 232 port backlit LCD measure & display trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. [6-3-5]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-34]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
M/s. Sai Construction (BID ID -6782233)
M/s Kranti Construction (BID ID -6780443)
K H CONSTRUCTION (BID ID -6783070)
Spectrum Infrastructure (BID ID -6781224)
M/s. KK G Construction Co. (BID ID -6774500)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 14.78 MB
BOQ.xls
BOQ • 0.83 MB
Tenderdocument_2.pdf
Tender Documents • 2.25 MB
Tenderdocument_3.pdf
Tender Documents • 0.56 MB
Download all tender documents and submit your bid