Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-Finance | ₹13.9 L | L1 | Accepted-Finance Valid documents received and accepted. |
| 2 | L2₹15.9 L+₹2.0 L (14.5%)Accepted-Finance | ₹15.9 L+₹2.0 L (14.5%) | L2 | Accepted-Finance Valid documents received and accepted. |
| 3 | L3₹17.4 L+₹3.4 L (24.8%)Accepted-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹17.4 L+₹3.4 L (24.8%) | L3 | Accepted-Finance Valid documents received and accepted. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Nov 2024, 6:00 pmClosed
Garrison Engineer
GE (AFA) Hyderabad, Dundigal, Hyderabad
REPAIR/ MAINTENANCE OF LAUNDRY PLANT/ FIRE ALARM SYSTEMS AND CERTAIN MISCELLANEOUS E/M WORKS AT AFA HYDERABAD
2024_MES_680083_1
8507/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AFA) Hyderabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (AFA) Hyderabad
₹50,000
Yes
12 Dec 2024
18 Oct 2024
18 Nov 2024
18 Oct 2024
15 Nov 2024
1 Nov 2024
18 Oct 2024 - 31 Oct 2024
Amount
Repairs/Servicing to the Fire alarm system by checking the following as per the manufacturer specifications including replacing the unserviceable spares by engaging well experienced technicians from an authorized service centre all as directed at site. Note: Spares required shall be measured and paid separately. (a) servicing all detectors of system of any type smoke/heat detector, servicing with blower and cleaning completely, including checking wire (b)Servicing of Intelligent addressable manual call points, including checking wire (c)Conventional sounder (d)Servicing of Intelligent addressable bell control panel (e)Servicing of Power supply unit for the above.
Supply only the following items for replacing only serviceable item No.1 above:-
12 Volts, 7AH DC Battery set complete for backup of complete system
8-zone microprocessor for automatic fire alarm system with UL/LPCB/CE approved.
Response indicators
PVC insulated multi stranded 1.5 sqmmX 2 core FRLSH copper conductor shielded cable
Detectors complying certified to EN-45 Addressable type smoke detector Photoelectric/ Optical with base with self built intelligence as per IS:11360
Same as per Item above but Addressable type heat detector with base with rate of rise cum fixed temperature as per IS:2175
Addressable manual call point resettable type
Hooter/Sounder
Single loop main control panel
Two loop main control panel
Mother board/ CPU for fire alarm system. Make : SIEMENS
Reprogramming 1loop control panel
Reprogramming 2loop control panel
Transformer 24-0-24 volts, 5 amps in existing
Isolator modules
Assorted fuses
24 Volts ,5A Switching mode power supply (SMPS) for fire alarm Panels as per existing make or type.
Repairs/ Servicing of hanger doors with necessary greasing and opening the motorised door mechanism of hanger door leaf, servicing /repairing the forward gear, backward gear, gear shaft, pinion, and replacing the worn out/unserviceable spares parts including checking/ maintenance of hanger door electrical panel board and reinstallation the same after repairs including replacement of necessary electrical connections from electrical panel board and checking the alignment bottom and rail for smooth movement of doors any unserviceable spares/ misc items with new one for the entire hanger door satisfactory working. The following major spares will be measured and paid separetly. Note :- All consumables like grease, cotton waste, nuts, bolts, washers, lugs etc are deemed to be included in the rate quoted
Supply only the following items for replacing only unserviceable item No.20 above:-
Limit switches for automatic cutoff for all driving leaves.
Auxillary Contactors
Power Contactors
Over Load relay
Single phase preventer
Under voltage protection relay
LED Indicator lamps of colors R / Y / B (Make: C&S/SIEMENS/L&T)
Over head cable trailering holders as per existing at site
Push button switches
Interlock contactors
Reduction gear drive suitable for to operate 2 HP motor cap
Gear Shaft
Gear Wheel
Bearing suitable for existing shaft
Gear Oil
Taking down old unserviceable PVC Cable and Supply & fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Sq. mm 4 Core nominal cross section in service connections along with replacement of corroded cable tray/bunching arrangement with suitable cable carriers, festoons etc as per existing capacity at site complete all as specified and as directed.
M & L for taking out motor from the base and re-winding of burnt 2 HP Cap 415 V, 3 phase motors of following capacities with new super enameled copper wire of same gauge and same number of turns as existing after thorough cleaning of stator body and rotor, applying insulating varnish, drying up by heating for improving insulation resistance, re-assembling the motor by replacing both end bearings, re-installing at it’s original position, connecting up, testing and commissioning all as specified and directed Make Kirloskar (For Hanger Doors)
M& L for Servicing of Washer Extractor 60 Kgs capacity of Make RAMSONS. Model RVWE-60 of high spin suspended , of stainless steel 304 grade, microprocessor controlled with moisture resistance screen, auto reverse automatic with pneumatic valves, front loading open pocket fully stainless steel die pressed door with inner cylinder and outer drum of stainless steel 304 grade complete with built in control panel & motor and replacement of unserviceable spares/ misc items with new one for following specifications :- Note: (i) The rated quoted by the contractor is deemed to be including all the Misc Items. Required major Spares required for completion of job satisfactorily measured and paid separately under respective items of the schedule (ii) All repairs/servicing /maintenance shall have to be carried out by the authorised service personnel
M& L for Servicing of Jumbo Boiler 5.5 ltr capacity of Make RAMSONS. Model RV 4425-80 with vacuum ironing table, and steam pressing iron including connecting up and replacement of unserviceable spares/ misc items with new one for following specifications :- Note: (i) The rate quoted by the contractor is deemed to be including all the Misc Items. Required major Spares required for completion of job satisfactorily measured and paid separately under respective items of the schedule (ii) All repairs/servicing /maintenance shall have to be carried out by the authorised service personnel
Supply only of the following spares for repairing /servicing the Mechanical Laundry :- (a) Teflon Shoe
Hose pipe for Steam
2128 Iron Box
Table Foam of existing size
Table Cloth of existing size
Foot Switch
16 Amps rocker switch
16 Amps contactor
Impeller
1 Hp motor
2 kw heater element
Water level control
6 Amps rocker switch
Pressure switch
Pressure guage
Ucp bearing 210
2 Hp main motor
PLC ST 200 complete set
Drain Valve
Water inlet valve
IO Card
Belt for Washing Extractor
Belt for Drier
Fuji drive for washing
Transformer 230v to 12 v
Water level sensor for washing
Shock absorber for washing
Air filter
1/2" Gauge glass with bush
Water level prob
M& L for Servicing of Washer Extractor 30 Kgs capacity, made out of fully stainless body, inne following spares for repairing the Mechanical Laundry of capacity 30 Kg Model No SWE 30, and flat work ironer Model No SFW-R/132 at FCM, Make Super Shine Laundry Systems all as specified and directed by Engr-in-Charge
Supply and fixing Paddings for FLAT Ironer complete all as specified and directed by Engr-in-Charge
Supply and fixing Feed Belts for FLAT Ironer complete all as specified and directed by Engr-in-Charge
Supply and fixing Water hose pipe for Water Extractor,Part No SWE30-001-10 complete all as specified and directed by Engr-in-Charge
Supply and fixing Water Solenoid valve for Water Extractor,Part No SWE30-001-9 complete all as specified and directed by Engr-in-Charge
Supply and fixing Door rubber gasket for Water Extractor,part No SWE30-001-27 complete all as specified and directed by Engr-in-Charge
M& L for Servicing of electrically operated screw Air compressor of Make ELGI Global Series Model E15-7.5 suitable for operating pneumatic tools for delivering air pressure of 100 PSI with a discharge capacity not less than 90 CFM with multistage oil and moisture separators driers comprised with VFD (Variable frequency Drive) direct drive technology with all connected accessories including 1000 ltrs compressed air container and replacement of unserviceable spares/ misc items with new one complete. Note: (i) The rated quoted by the contractor is deemed to be included all the Misc/ Spares required for completion of job satisfactorily (ii) All repairs/servicing /maintenance shall have to be carried out by the authorised service personnel
Supply and Fix quality Industrial Type Air Filter cum regulator integral of Make Kobalt ingersolrand with suitable pressure gauge and air regulator arrangement suitable for 40mm dia bore tube by replacing the unserviceable complete all as directed
M&L for servicing of 100 KW Solar PV integrating with 400 nos of 250 Wp each SPV panel complete including cleaning of area and solar panel plate, checking all connections all as specified and directed below :- Note:-First visit will be carried out within 30 Days of acceptance and second after minimum four month . Note: (i) The rated quoted by the contractor is deemed to be including all the Misc Items. Required major Spares required for completion of job satisfactorily measured and paid separately under respective items of the schedule
M&L for servicing of ELECTRIC CHIMNEY/Fume exhaust system electrically operated with centrifugal blower driven by 7.5 HP, 1440 RPM, 415 V, 50 Hz, 3 Phase electric induction motor suitable or as directed by OEM for achieving 8000 CFM and exhaust blower capacity of 8000 CFM :- .
M & L for taking out motor from the base and re-winding of burnt 7.5 HP Cap 415 V, 3 phase motors with new super enamelled copper wire of same gauge and same number of turns as existing after thorough cleaning of stator body and rotor, applying insulating varnish, drying up by heating for improving insulation resistance, re-assembling the motor by replacing both end bearings, re-installing at it’s original position, connecting up, testing and commissioning all as specified and directed (For Chimney)
Supply and fixing of following spares for repairing /servicing the voltage stabilizer/isolating transformer Panel Lamp
(b) Push Button Switch
(c) Auto Manual Switch
(d) DPDT Switch
(e) Carbon Brush
(f) Micro Switch
(g) Potentiometer
(h) Trigger Transformer
(j) Rotary switch 5 Amp for RYB phases
(k) Volt Meter
(l) Ampere Meter with CT 100/5 A.
(m) Electronic Circuit Card(PCB) for 40KVA & 150 KVA Stabilizer
(n) Servo Motor 3 KG torque for 15 KVA Stabilizer
(q) Drive Assembly upto 75 KVA per Phase
(r) Dimmerstat 10 KVA 10 Amp
(s) Dimmerstat 40 KVA 28 Amp
(t) Main Transformer for 10 KVA
Supply and filling up of Insulating transformer oil including replacing the minor parts like nuts, bolts, washers, gaskets etc., clean the oil sump thoroughly and filling with new transformer oil duly filtered to achieve dielectric strength of minimum 40 KV at 2.5mm gap complete all as specified and all as directed by Engineer-in-charge for Servo Stabilizer and Isolation Transformer. Make: Electrol/Power Oil/ CASTROL/SAVSOL
AKSHITA ELECTRICAL (BID ID -3160370)
Rahul Enterprises (BID ID -3156090)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .