Superintending Engineer
Superintending Engineer No 18 1st main road CIT Nagar chennai35
Providing Electrical works for the Construction of Multi Storied Office cum Commercial Complex Building 3 Basement with G.F with 17 Floors in S.No. 343 of Mylapore Village and Taluk, Triplicane part 2. Block 11, Chennai District.
2026_TNHB_729388_1
CC-II/03/2026-27
Open Tender
Civil Works - Others
Item Rate
120 days
MYLAPORE
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹2.9 L
21 Nov 2026
21 Nov 2026
4 Dec 2026
21 Nov 2026
4 Dec 2026
21 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | ELECTRICAL WORK | - | - | - | - |
| 2 | 33 KV Ring Main Gear (RMG) - Outdoor Type
Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV,50Hz, A.C.distribution network, complete with all accessories excluding foundation complete as per specfication and standards as directed by departmental officers Outdoor Type Panel 33kV HT Ring Main Gear Comprising of Incomer :2nos 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements (AS PER TANGEDCO NORMS). Outgoings :1no of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements (AS PER TANGEDCO NORMS).Busbars:33KV,800A,TP,50Hz,26.3 KA, Copper. BusbarsThe panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets and as per TANGEDCO Requirements. PANEL & BREAKER COMPONENT 33KV Outdoor VCB panel 33kV,800A 26.3kA/1 sec Metal base frame Vaccum Circuit Breaker Closing & Triping Coil:110V DC. Spring Charge Motor: 230V AC, Auxiliary Switch (8 NO & 8NC).Main Bus bar/Earth Busbar(Copper).INSTRUMENT TRANSFORMER
Single phase Current Transformer 33kV Resin Cast Current Transformer (65/5-5A),Core1: Class: 0.2s, Burden: 5VA, Core 2: Class: 5P20, Burden:15VA. STC: 25KA Time: 1 Sec ILV 36/70/170 kVp. Secondary Terminal on P1 Side. Single phase potential Transformer (BUS PT) Fixed Type 33kV Single Phase Potential Transformer with HT fuse, 33kV/R3/110/R3Core1: Class: 0.2, Burden:50VA,Voltage Factor 1.2 Continuous/1.5 for 30 Seconds. ILV 36/70/170 kVp. With one Nos. HRC Fuse on HV side of Rating 33kV, Amp Battery backup based Power packDual output.Input Voltage: 230VAC, Output Voltage: 110VDC, Burden: 100VA Surge Arrestor 30KV ,10KA CL-1, RELAYS & CONTACTORS
Numerical Over Current & Earth Fault Without communication port Protections, 50, 50N, 51, 51N Aux. Voltage: 110VDC Anti pumping relay
Aux. Voltage: 110VDC Electromechanical based control Master Trip Relay1 Element (3 NO & 1 NC)Aux.Voltage: 110VDC Auxillary Relay (2NO&NC) Aux. Voltage: 110VDC, METER Analog Ammeter Scaling range (0-150A/5A) 90 degree scale Accuracy Class 1.0
Cut out: 96 X 96mm Ammeter Selector Switch 6A,3 ways with OFF Position(R, Y, B & OFF) Size : 48 X 48 mm Analog Voltmeter
Scaling range (0-11kV/110/V3) 90 degree scale Accuracy Class 1.0 Cut out: 96 X 96mmVoltmeter Selector Switch 6A,3 ways with OFF Position(RY, YB, BR & OFF)Size : 48 X 48 mm Digital Multi Function Meter with RS 485 Port Ratio: CTR: 5A, PTR: 110V AC Accuracy Class: 0.5
Cut out : 96 X 96mm, SWITCHES & FUSE MCB 2 Pole, 230V, 6A 1O KA AC2 Pole, 110V, 10A 6 KA DCFUSE 20 A Fuse holder 6A fuse4A fuse
Neutral link 32ATrip neutral switch (breaker control switch)16ALocal / remote switch16ADoor limit switch 5ABreaker position limit switch10A
Toogle switch 10A On/Off switch 5A, INDICATION LAMPS Red (VCB ON Indication),service Green (VCB OFF Indication)test
Blue (Spring charge Indicaton) Amber (Auto Trip Indication) White (Trip Circuit Healthy) White push button with 1 NO Contact Green(test position indication) Red (service position indication) Mushroom head push button with 1 NO & 1NC Contact RYB indication lamp 22 dia Ultra Super Bright LED Cluster Type Indicating lamp Aux. Voltage: 110VDC, PANEL ACCESSORIESThermostat 30 degree C to 85 degree CSpace Heater 230VAC, 80WLED lamp with Holder 230VACSocket With Switch 16A 5pin socket8 window annunciator with hooter110V DC | 1 | NOS | - | - |
| 3 | 33 kV HT 1 VCB Panel (Outdoor Type )
Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV, 50Hz, A.C.distribution network, complete with all accessories excluding foundation complete as per specfication and standards as directed byDept.oficers..1no 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB, PANEL & BREAKER COMPONENT
33KV Outdoor VCB Panel with metal base frameHorizontal draw out Mu Series Vacuum Circuit Breakerflowing accessories.Vacuum Interrupter(BEL MAKE) Trip coil 110V DC Closing coil-110V DCSpring charging motor-230V ACBreaker Aux swilch 8NO+8NC contactsAnti-pumping relayMechanical close and trip PB Manual Spring charging device Mechanical operation counter Mechanical ON-OFF indicator Mechanical Spring charged Indicator 33KV 630A 25KA/3 sec Main Bus bar Aluminum Earth busbar Aluminum INSTRUMENT TRANSFORMER
Single phase Current Transtormer 33kV Resin Cast Current Transformer (66/5-5A) Core 1: Class 1.0, Burden: 5VA Core 2: Class: 5P10, Burden: 1OVA, STC 100XIP 1 SEC
IIV 36/70/170kVp. Secondary Terminal on P1 Side. Single phase potential Transformnor 33kV Indoor Epoxy Resin Cast VT Single Phase 50 Hz Ratio 33kV/V3/110/V3/110/V3
CORE 1: Clans: 1.0, Burden 25VA Voltage Factor 1.2 Continuous/1.5 for 30 Seconds. ILV 36/70/170kVp with one nos. HRC Fuse on HV sidio of Rating 36kV. Surge Arrestor 10KA 30KV Single Output Power Pack Input: 230VAC, Output: 110VDC, Burden:100VA RELAYS & CONTACTORS Numerical Over Current & Earth Fault without communication port 50/51/50N/51N
Aux. Voltage: 110 VDC Electromechanical based control Master Trip Relay 1 Element (3 NO & 1 NC) Aux voltage 110 V dc Auxiliary Relay 2 CO Aux voltage110 V DC, METERS
3ph Digital Ammeter CL: 1.0 Aux. Voltage: 230VAC 3ph Digital Voltmeter CL: 1.0 Aux. Voltage: 230VAC Digital Multifunction meter With RS485Communication port CL: 1.0 Aux. Voltage: 230VAC SWITCHES & FUSES MCB 2 Pole, 230V, 6A 1OKA AC 2 Pole, 110V, 10A 6KA DC FUSE 20 A Fuse holder6A fuse4A fuseNeutral link32ATrip Netural Switch(Breaker Control Switch)16ALocal/Remote Switch Door limit Switch 16ADoor limit switch 10A Breaker position limit switch 10AToodle switch10AON/OFF SWITCH 10A , INDICATION LAMPSRed (VCB ON Indication), SERVICEGreen (VCB OFF Indication), TESTBlue (Spring charge Indication)Amber (Auto Trip Indication)White (Trip Circuit Healthy)White push button with 1 NO Contact
Green (Test Position indication)Red(service position indication)Mushroom head push button with 1 NO & 1NC Contact22 dia Ultra Super Bright LED Cluster Type Indicating lampAux.Voltage: 110VDCRed (R Phase Indication)Yellow (Y Phase Indication)Blue (B Phase Indication)22 dia Ultra Super Bright LED Cluster TypeIndicating lampAux. Voltage: 63.5VAC.PANEL ACCESSORIESThermostat 30ºC to 85ºC Space Heater 230VAC, 80W LED lamp with Holder 230VAC Socket With Switch 8 Window Annunciator with Hooter 110V DC | 1 | NOS | - | - |
| 4 | 33 kV HT 4 VCB Panel (Outdoor Type )
Design, Manufacture, Assembly, Inspection and Testing before supply,Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,33kV,50Hz, A.C.distribution network, complete with all accessories excluding foundation complete as per specfication and standards as directed by Dept.officers..Outdoor Type Panel 33kV HT Panel-1 Comprising of Incomer :1no 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements Outgoings :3nos of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements Busbars:33KV,800A,TP,50Hz,26.3 KA, Copper. Busbars The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, Arc flashrelay,, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets. PANEL AND BREAKER COMPONENTS 33KV Outdoor VCB Panel Metal base frame Vacuum Circuit Breaker 33kV,800A,26.3kA / 1 sec, Closing & Triping Coil:110V DC, Spring Charge Motor: 230V AC, Auxiliary Switch (8 NO & 8 NC). Main Bus bar / Earth Busbar Copper. INSTRUMENT TRANSFORMER1Ø Current Transformer33kV Resin Cast Current Transformer (65/5-5A),Core1: Class: 1, Burden: 5VA,Core 2: Class: 5P10, Burden:10VA. STC: 25KA Time : 1 Sec ILV 36/70/170 kVp. Secondary Terminal on P1 Side. 1Ø potential Transformer ( BUS PT) Fixed Type33kV Single Phase Potential Transformer with HT fuse, 33kV/R3/110/R3Core1: Class: 0.2, Burden:50VA,Voltage Factor 1.2 Continuous/1.5 for 30 Seconds. ILV 36/70/170 kVp.With one Nos. HRC Fuse on HV side of Rating 33kV, Amp Battery backup based Power pack
Dual output.Input Voltage: 230VAC, Output Voltage:110VDC, Burden: 100VA Surge Arrestor 30kV. 10KA CL-1 RELAYS & CONTACTORS Numerical Over Current & Earth Fault
Without communication port Protections, 50, 50N, 51, 51N Aux.Voltage : 110VDC Anti pumping relay Aux. Voltage: 110VDC Electromechanical based control
Master Trip Relay1 Element (3 NO & 1 NC) Aux.Voltage : 110VDC Auxiliary Relay (2NO&NC). Aux.Voltage : 110VDC Auxiliary Relay Din rail Mounted with base for Transformer Protection
2 Element (2 NO) Aux.Voltage : 110 VDC. METERS Analog Ammeter Scaling range (0-150A/5A) 90 degree scale Accuracy Class 1.0 Cut out: 96 X 96mmAmmeter Selector Switch 6A,3 ways with OFF Position(R, Y, B & OFF)Size : 48 X 48 mm Analog VoltmeterScaling range (0-11kV/110/V3)90 degree scale Accuracy Class 1.0 Cut out: 96 X 96mm Voltmeter Selector Switch 6A,3 ways with OFF Position(RY, YB, BR & OFF)Size : 48 X 48 mm Digital Multi Function Meter with RS 485 Port Ratio: CTR: 5A, PTR: 110V AC Accuracy Class: 0.5 Cut out : 96 X 96mm | 1 | NOS | - | - |
| 5 | Supply, Laying, testing and commissioning of 3 core 300 sqmm 33KV, XLPE Aluminium conductor individual core screened, PVC sheathed, flat steel strip armoured earthed cable From RMG to HT yard(Transformer) | 100 | RMT | - | - |
| 6 | Cable shall be laid in ground , necessary excavation, sand brick protection and back filling -From RMG to HT yard(Transformer) | 100 | RMT | - | - |
| 7 | Supply & Installation of outdoor type heat shrinkable end termination kits and making End Terminations for XLPE insulated HT power cables 33kV grade of 3Cx300sqmm | 12 | NOS | - | - |
| 8 | SINGLE ACB PANEL -OUTDOOR Type
Supplying, installation, testing & commisioning of 3200A 50kA 4P EDO ACB Panel with provision of suitable size bus bars for Incomming cable of suitable runs to suffice the load requirements and outgoing Bus Duct connections with O/C, S/C, E/F release SC for 1 sec as Isoaltor Unit made with 2mm thick steel sheet enclosure (IP55) duly powder coated with ACB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories and necessary items for work etc. as required. Separate cable alley need to be considered for cable termination considering the cable bending.(FOR each Transformer 1 nos) Air Circuit BreakerRated current (In) 3200 ARated voltage (Ue) 415 V AC 3-phase, 4-wireFrequency 50 HzPoles 4P Mounting Draw-out type preferred for main LT incomerStandard IEC 60947-2
Trip unit ElectronicProtection LSI / LSIGShort-circuit breaking capacity (Icu) 65 kA Service breaking capacity (Ics) 65kAShort-time withstand (Icw) Typically 65–85 kA for 1 sec for high-capacity modelsRated insulation voltage (Ui) Typically 800–1000 V Impulse withstand (Uimp) Typically around 8–12 kV Closing Manual + electrical
Opening Manual + shunt/electrical trip Under-voltage release Required where specified Shunt trip RequiredAuxiliary contacts NO/NC as required Spring chargingMotorizedInterlocking
Mechanical/electrical as required Communication Optional Modbus/BMS depending on trip unit Neutral protectionAdjustable/100% neutral option depending on 4P model | 3 | NOS | - | - |
| 9 | Design, supply, erection, testing and commissioning of 3200 Amps TPN 433V,50 Hz LV Busduct 50kA outdoor sandwich type Aluminium4Pole busduct and with suitable support from ceiling as per the detailed specification enclosed. The busduct shall have 2Rnus of external body earth conductor along full length of busduct. The bus duct shall be fabricated as per the detailed specification.(From HT yard to Electrical room) | 50 | RMT | - | - |
| 10 | Design, supply, erection, testing and commissioning of 3200 Amps flexible joints suitable for sandwich type 4P Aluminiumbus duct at end terminals including all accessories.(RYB+N=1set) | 2 | NOS | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
SCHEDULEupload.pdf
Tender Documents • 0.58 MB
BOQ_875361.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .