Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC AT MAIN ROAD KATHARA PO KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | L1 | Accepted-AOC Accepted as L1 as per NIT | |
| 2 | L2₹3.2 L+₹12,594.80 (4.12%)Rejected-Finance MAIN ROAD RAMGARH CANTT 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-Finance Not accepted as per NIT | |
| 3 | L3₹3.3 L+₹21,638.25 (7.07%)Rejected-Finance NEAR RELIANCE PETROL PUMP RAMGARH CANTT 829122 DIST RAMGARH JHARKHAND | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-Finance Not accepted as per NIT |
Tender Value
₹3.6 L
EMD Value
₹4,600
Closing Date
22 Feb 2025, 4:00 pmClosed
Colliery Manager (M), Manager(F), Project Engineer
P.E. (EnM), Office of the PO, Kathara Colliery
installation of one No. 11KV, 400Amps, VCB (Make-Madriton) at river side pump house and one No. 6.6KV, 400 Amps VCB (Make-Meditron) at Regional sub-station and one No.6.6KV, 400 Amps VCB (Make-Transgietz) at 02 no Electrical sub-Station Kathara.
2025_CCL_328581_1
KTC/PE/EnM/24-25/214 date-10.02.2025
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Office of the Project Officer, PE (EnM), Kathara C
installation of one No. 11KV, 400Amps, VCB (Make-Madriton) at river side pump house and one No. 6.6KV, 400 Amps VCB (Make-Meditron) at Regional sub-station and one No.6.6KV, 400 Amps VCB (Make-Transgietz) at 02 no Electrical sub-Station Kathara.
6 documents required · 6 mandatory
₹4,600
Yes
12 Mar 2025
11 Feb 2025
24 Feb 2025
12 Feb 2025
22 Feb 2025
12 Feb 2025
12 Feb 2025 - 19 Feb 2025
Amount
Earth work by mechanical manual means in rough excavation, banking excavated earth in layer not exceeding 20cm in depth, braking clods, watering , rolling each layer with t: tonner roller or wooden or steel rammers, androlling every 3rd and top most layer with power rollerof minimim 8 tonnes sand dressing up in embankments fr roads, flood banks marginal bank sand guide banks or filling up ground depressions lead upto 50M and for all lif: all kinds od soil (01) For VCB-0.65 mtrs x(2mtr+2mtr+1mtr+1mtr)=3.9 CUM)
Brick work with common burnt clay F.P.S (Non Modular) Bricks of class designation 7.5 in foundation and plinth in :1 Cement mortar 1:4 (1 Cement:4 Coarse sand) (1) for VCB-0.25 mtrsx2x2.5mtr+2mtrx0.75 mtr)x2 nos=3.25 CUM+0.75 CUM (for Stairs)= 4 CUM
Providing and laying in position specified grade of rein forced cement concrete, excluding the cost of centering, shuttering, finishing and rein forcement-All Work upto planth level :1:2:4 (1 cement :2 Coarse sand (Zone III) Derived from natural sources: 4 grade stone aggregate 20 MM nominal size derived from natural sources (1) for VCB-0.25 Mtrx 2 Mtrx2.5mtrx2 Nos=2.5 CUM
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick. (i) For VCB-2 Mtrx(2x2 mtr+2x1mtr)x0.0508=0.60 CUM +0.20 CUM (For stairs)= 0.80 CUM
Supply and fillig in plinth with sand under floors, including watering, ramming, consolidating and dressing complete For VCB-1.75Mtrx(2x1.75 mtr+2x0.50 mtr=7.87 CUM
Supply & Fixing of Bi-Metalic Connector
Supply & Fixing of 120Sq.mm, Copper lugs
Laying of one number PVC insulated and PVC Sheathed/XLPE Power Cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95sq.mm and upto 185 Sq.mm
Laying of one number PVC insulated and PVC Sheathed/XLPE Power Cable of 1.1KV grade of following size in the existing masonry open duct as required.
Cable, 16 Core, 2.5 Sq.mm Armoured.
Wiring with ferrul and Lugs
Providing & fixing maintenance earth resistance G.I bonded tube 3 mtr, 50mm and advanced ground enhancing compound 02 bags, ISO 9601-2000 Certofied with installation complete
Supply & Fixing of aluminium Unarmoured cable single core 1100 Volts grade 35 sq mm
Suppluing and erection of 11KV Disc insulator for 11KV over head lines with galvanised insulator fitting, ball and socket type and complete with galvanised strain clamps, bolts, nuts washer etc. as required.
Supplying and erection of 11KV pin insulator complete with large steel head G.I Pin Nuts washer etc. as required.
Erection of ACSR Conductor of 7/32.35 mm to 7/4.00 diameter and above including binding etc. as required (30Mtrx3wirex1 span =90 mtr+4.5 mtr (for jumphering)= 94.5x0.394kg/Mtr=37.23
Total impact of GST for the purpose of CTC
M.k. Traders (BID ID -1130153)
Rajneesh Electricals (BID ID -1130877)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .