Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.1 L+₹1.8 L (29.4%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹8.7 L+₹2.4 L (38.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹10.8 L
EMD Value
₹21,600
Closing Date
18 Oct 2021, 6:00 pmClosed
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF UG CABLE AND LT PANEL AT TIGER HILL AND ADDN/ALTN OF UG CABLE AND LT PANEL AND CONNECTED ITEMS AT DELTA CAMP AND TIGER HILL AT DHURMUND UNDER GE(I) 873 EWS
2021_MES_476569_1
NIT-47 of 21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) 873 EWS
₹21,600
Yes
12 Nov 2021
20 Sept 2021
21 Oct 2021
20 Sept 2021
18 Oct 2021
4 Oct 2021
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core laid in trenches or passing through pipes/ducts or fixed to walls/poles, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old cable, complete complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Laying only serviceable bricks as mechanical protection to underground cable with width equal to length of bricks, width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
On load change over switch 200 Amps, 4 pole, 415 volts, including taking down old unserviceable change over switch, complete all as specified and directed.
On load change over switch 100 Amps, 4 pole, 415 volts, including taking down old unserviceable change over switch, complete all as specified and directed.
Supply & fix in repair Bus bar panel size 0.8x0.4x0.4 Mtr, KISOK, outdoor type, CRPI tested, LT 440 Volts, 50 Hz, 3 phase 4 wire supply, comprising of bus bas chamber with 4 Nos aluminium strip bus bars PVC insulated with colour coding af rating 200A, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 thick MS sheet CRCA on angle iron 30x30x4mm frame with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufactures in PCC 1:3:6 type C-2, using 40 mm graded crushed stone aggregate as directed by the Engr-in-Charge including earth work complete all as specified.
M&L testing & commissioning in replacement LT Panel, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement including powder coating up to 50 to 60 micron layer after phosphating process internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following fitments-
(A) Incoming (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size suitable for 250A current. PVC sheathed with colour coding. (b) MCCB having current ratings 250 Amps with rupturing cap 25 KA , AC 415 Volts four pole with microprocessor release complete with spreader links. - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, including suitable CTs with secondary current 5A, with display volt, Amp , Frequency, KWH. - 01 No
(B) Outgoing (a) MCCB having current ratings 100 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 02 Nos (b) MCCB having current ratings 63 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 01 Nos (c) MCB SPN 32 Amps-02 Nos (d) MCB SPN-20Amps-02 Nos All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
M&L testing & commissioning in LT Panel, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement including powder coating up to 50 to 60 micron layer after phosphating process internally and externally complete over a coat of red oxide primer, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following fitments-
(A) Incoming (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size suitable for 630A current. PVC sheathed with colour coding. (b) MCCB having current ratings 400 Amps with rupturing cap 36 KA , AC 415 Volts four pole with microprocessor release complete with spreader links. - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, including suitable CTs with secondary current 5A, with display volt, Amp , Frequency, KWH. - 01 No
(B) Outgoing (a) MCCB having current ratings 250 Amps with rupturing cap 36 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 01 Nos (b) MCCB having current ratings 160 Amps with rupturing cap 36 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 03 Nos All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Make of Panels : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO
M/S BALI CONSTRUCTIONS
M/S Builders Indias
Bidder Name
M/S BALI CONSTRUCTIONS
M/S Builders Indias
RAVI KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .