Chief Engineer (D and R)
Office of Chief Engineer (D and R)
DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT KOHIMA (PART-I) DISTRICT OF NAGALAND UNDER THE REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME-RDSS
2024_DP_678_1
CEL/DnR/RDSS/LR/NIT/PKG-KMA (PART-I)/72
Open Tender
Electrical Works
730 days
Nagaland
Refer RFB
3 documents required · 3 mandatory
₹25,000
Chief Engineer (D and R)
₹90.7 L
9 Sept 2024
3 Sept 2024
9 Sept 2024
3 Sept 2024
9 Sept 2024
6 Sept 2024
Amount
A. REPLACEMENT OF LENGTHY LT NETWORK WITH HT
A-1 Supply of Materials for 11 kV Line with Weasel conductor (9.5 M GI STP SP-35 Pole)
GI Steel Tubular Pole SP-35(9.5M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
GI Angle 65X65X6 mm, 5M Length weighing approx 5.8 Kg/Mtr for Road Crossing
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top Section ) weighing 1.4 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top section) weighing 0.7 kg each for SP Brackets
dia - 115 mm (Middle section ) weighing 0.84 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 3 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 8 SWG for Guarding weighing 0.131 Kg/Mtr
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Weasel Conductor
Tension Claim for ACSR Weasel
PG Claim for ACSR Weasel
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
(A-2) Supply of Materials for Construction of 11/0.4 kV, 100KVA Distribution Transformer (Copper/Aluminium Wound) IS:1180 (part I) 2014 Amendment 4, conforming to BIS efficiency Level-2, table 3 Technical Specifications.
GI Steel Tubular Pole SP-35(9.5M)
100 KVA, 11/0.4 KV,3-Ph,CRGO Core, 50 Hz, Oil Type,Transformer (Copper/Aluminium Wound) with Off Circuit Tap Changer, as per IS:1180 (part I) 2014 Amendment 4, conforming to BIS efficiency Level-2, table 3 Technical Specifications.
GI Channel 100x50x5 mm, 2.2 M Length weighing approx 9.60Kg/Mtr -7 nos
GI Angle 50X50X6 mm weighing, 2.2 Mtrs weighing approx 4.5 Kg/Mtr for LT hor Gap/Kit Kat/DTR Metering Box- 2 NOS
11 KV Lightning arrestor, (9KV, 5KA, 1Ph) Outdoor, Gapless Polymer Lightning/Surge Arrestor Distribution Type/Class complete with insulating base, terminal connectors.
11KV, 400A, 3-ph, Gang Switch (Rocking Type Air Break Isolator) along with support insulators operating mechanism, Base Channel, down GI Pipe, terminal connectors and other accessories complete.
11 KV Drop Out fuse of rated current 100 A/ 200A/400A, 3Ph complete with fuse carrier assembly, fuse base & tube and mounting arrangement as per IS:9385 (Part-I to III).
DT Earthing
Copper Plate 2ft x2 ft, 3mm thick (weighing 11Kg each) for DT Neutral and Body - 2 nos
Copper Plate 1'x1', 3 mm thick (weighing 3Kg each) for LA -1No
Copper wire 5 SWG for Neutral - 12 Mtrs (weighing 0.204Kg per mtr)
Copper wire 5 SWG for Body - 12 Mtrs (weighing 0.204Kg per mtr)
Copper wire 5 SWG for LA - 20 Mtrs (weighing 0.204Kg per mtr)
Charcoal - (20kg/bag)
salt - 50Kg
2" (25mm) GI Pipe 3 mtr (for water recharge/alternate electrode)
ACSR WEASEL Conductor 6/2.59mm + 1/2.59 mm.
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
11 kV Polymer Disc insulator B&S (70KN)
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
Tension clamp for ACSR Weasel
PG Clamp for Weasel
LT XLPE Single Core Aluminium Conductor Armoured Power Cable (for DT terminal to LT Bus Bar and LT Bus bar to feeder Pole)
120 Sqmm (AL) for DTR LT Bushing to Bus Bar
95 Sqmm (AL) (for Bus to line 2 CKt)
70 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top Section ) weighing 1.4 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top section) weighing 0.7 kg each
dia - 115 mm (Middle section ) weighing 0.84 kg each
dia - 140 mm (Bottom Section) weighing 0.98 kg each
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length,Bow,Anchor Plate, guy insulator etc complete set
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr) - 28Mtrs
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 200mm ((5/8"x8") each weighing 0.43 kg - 12 nos
16 mm dia x 100mm ((5/8"x4") each weighing 0.269 kg - 48 nos
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg - 16 nos
16 mm dia x 50mm ((5/8"x2") each weighing 0.19kg - 24 Nos
12 mm dia x 65mm ((1/2"x2 1/2") each weighing 0.115 kg
GI Washers 3mm thick of 18mm inner dia each weighing 0.011Kg, suitable for 16mm (5/8") threaded bolt - 200 nos
GI Washers 3mm thick of 14mm inner dia each weighing 0.0063Kg, suitable for 12 mm (1/2") threaded bolt - 6 nos
Danger plate 11KV
Aluminium Tape
DTR FENCING WITH welded Mesh Fencing made of GI Rod 6-Gauge vertical spacing 150mm horizontal spacing 100mm. The length of the roll shall be 15 Mtrs and height of the roll shall be 2.44 Mtrs.
G. I Pipe 50mm (2") 3 Mtrs (10') Length for Fencing Frame & Post
G. I Pipe 25mm (1") , 3 Mtr (10') Length for Fencing Gate Frame
(A-3) Supply of Materials for Construction of 11/0.4 kV, 63KVA Distribution Transformer (Copper/Aluminium Wound) IS:1180 (part I) 2014 Amendment 4, conforming to BIS efficiency Level-2, table 3 Technical Specifications.
GI Steel Tubular Pole SP-35(9.5M)
63 KVA, 11/0.4 KV,3-Ph,CRGO Core, 50 Hz, Oil Type,Transformer (Copper/Aluminium Wound) with Off Circuit Tap Changer, as per IS:1180 (part I) 2014 Amendment 4, conforming to BIS efficiency Level-2, table 3 Technical Specifications.
GI Channel 100x50x5 mm, 2.2 M Length weighing approx 9.60Kg/Mtr -7 nos
GI Angle 50X50X6 mm weighing, 2.2 Mtrs weighing approx 4.5 Kg/Mtr for LT hor Gap/Kit Kat/DTR Metering Box
11 KV Lightning arrestor, (9KV, 5KA, 1Ph) Outdoor, Gapless Polymer Lightning/Surge Arrestor Distribution Type/Class complete with insulating base, terminal connectors.
11KV, 400A, 3-ph, Gang Switch (Rocking Type Air Break Isolator) along with support insulators operating mechanism, Base Channel, down GI Pipe, terminal connectors and other accessories complete.
11 KV Drop Out fuse of rated current 100 A/ 200A/400A, 3Ph complete with fuse carrier assembly, fuse base & tube and mounting arrangement as per IS:9385 (Part-I to III).
DT Earthing
Copper Plate 2ft x2 ft, 3mm thick (weighing 11Kg each) for DT Neutral and Body - 2 nos
Copper Plate 1'x1', 3 mm thick (weighing 3Kg each) for LA -1No
Copper wire 5 SWG for Neutral - 12 Mtrs (weighing 0.204Kg per mtr)
Copper wire 5 SWG for Body - 12 Mtrs (weighing 0.204Kg per mtr)
Copper wire 5 SWG for LA - 20 Mtrs (weighing 0.204Kg per mtr)
Charcoal - (20kg/bag)
salt - 50Kg
2" (25mm) GI Pipe 3 mtr (for water recharge/alternate electrode)
ACSR WEASEL Conductor 6/2.59mm + 1/2.59 mm.
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
11 kV Polymer Disc insulator B&S (70KN)
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
Tension clamp for ACSR Weasel
PG Clamp for Weasel
LT XLPE Single Core Aluminium Conductor Armoured Power Cable (for DT terminal to LT Bus Bar and LT Bus bar to feeder Pole)
i). 95 Sqmm (AL) ( DT Terminal to LT Bus)
ii) 70 Sqmm (AL) (for Bus to line 1 CKt)
iii). 25 Sqmm (AL) (for Neutral)
Copper Tubular Terminal ends/Lugs heavy duty (for DTs only)
ii) 95 Sqmm
ii) 70 Sqmm
iii) 25 Sqmm
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top Section ) weighing 1.4 kg per pair
dia - 140 mm (Bottom Section) weighing 1.96 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top section) weighing 0.7 kg each
dia - 115 mm (Middle section ) weighing 0.84 kg each
dia - 140 mm (Bottom Section) weighing 0.98 kg each
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length,Bow,Anchor Plate, guy insulator etc complete set
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 200mm ((5/8"x8") each weighing 0.43 kg
16 mm dia x 100mm ((5/8"x4") each weighing 0.269 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
16 mm dia x 50mm ((5/8"x2") each weighing 0.19kg
12 mm dia x 65mm ((1/2"x2 1/2") each weighing 0.115 kg
GI Washers 3mm thick of 18mm inner dia each weighing 0.011Kg, suitable for 16mm (5/8") threaded bolt
GI Washers 3mm thick of 14mm inner dia each weighing 0.0063Kg, suitable for 12 mm (1/2") threaded bolt
Danger plate 11KV
Aluminium Tape
DTR FENCING WITH welded Mesh Fencing made of GI Rod 6-Gauge vertical spacing 150mm horizontal spacing 100mm. The length of the roll shall be 15 Mtrs and height of the roll shall be 2.44 Mtrs.
G. I Pipe 50mm (2") 3 Mtrs (10') Length for Fencing Frame & Post
G. I Pipe 25mm (1") , 3 Mtr (10') Length for Fencing Gate Frame
(A-4) Supply of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-70 Sq.mm on SP-11 Pole
GI Steel tubular pole SP-11
Pole Double Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Pole Single Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Cable ABC 1.1 kV XLPE with insulated messenger with one Streelight Cond. 3CX 70Sqmm (213A) + 1CX 50 Sqmm (Insulated Messenger/Neutral) + 1CX 25 Sqmm (Street light).
Cable Tie
Anchor clamp wedge type LT ABC as per NFC standard
Suspension Clamp ABC as per NFC standard
Eye Hook/Eye Bolt
Insulating Piercing Connector IPC EP95 for Streetlighting as per NFC Std.
Insulating Piercing Connector IPC P2X95 FOR DB CHARGING as per NFC Std.
Insulating Piercing Connector IPC P3X95 for ABC to ABC TEE connection as per NFC Std.
Cable end caps for ABC cables
ASA Distribution box for 140A, 1Ph. 10 Connectors with Spring Loaded Busbar System
Steel Strap for Installing DB size 20 mm X 1 m long
Buckles for steel Strap for DB Fixing
Insulated Waterproof bimetallic lug for Transformer Connections (Set contains 5 nos. Lugs as per Cable) as per NFC Std.
Insulated Crimping type Midspan Joint (Set contains 5 nos. Ferrules as per Cable) as per NFC Std.
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
LT stay set with GI Rod of 16mm dia and 1.6 Mtr Length,Bow,Anchor Plate, guy insulator etc complete set
G.I Stay wire , 7/12 SWG, 10Mtr per stay set (weighing 0.300 kg per mtr)
( A-5 ) Supply of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-50 Sq.mm on SP-11 Pole
GI Steel tubular pole SP-11
Pole Double Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Pole Single Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Cable ABC 1.1 kV XLPE with insulated messenger with one Streelight Cond. 3CX 50Sqmm (213A) + 1CX 35 Sqmm (Insulated Messenger/Neutral) + 1CX 16 Sqmm (Street light).
Cable Tie
Anchor clamp wedge type LT ABC as per NFC standard
Suspension Clamp ABC as per NFC standard
Eye Hook/Eye Bolt
Insulating Piercing Connector IPC EP95 for Streetlighting as per NFC Std.
Insulating Piercing Connector IPC P2X95 FOR DB CHARGING as per NFC Std.
Insulating Piercing Connector IPC P3X95 for ABC to ABC TEE connection as per NFC Std.
Cable end caps for ABC cables
ASA Distribution box for 140A, 1Ph. 10 Connectors with Spring Loaded Busbar System
Steel Strap for Installing DB size 20 mm X 1 m long
Buckles for steel Strap for DB Fixing
Insulated Waterproof bimetallic lug for Transformer Connections (Set contains 5 nos. Lugs as per Cable) as per NFC Std.
Insulated Crimping type Midspan Joint (Set contains 5 nos. Ferrules as per Cable) as per NFC Std.
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
LT stay set with GI Rod of 16mm dia and 1.6 Mtr Length,Bow,Anchor Plate, guy insulator etc complete set
G.I Stay wire , 7/12 SWG, 10Mtr per stay set (weighing 0.300 kg per mtr)
Description of Work / Item(s)
Amount
A. REPLACEMENT OF LENGTHY LT NETWORK WITH HT
(A-1) Erection, Installation, Commissioning & Testing of Materials for 11 kV Line with Weasel conductor (9.5 M GI STP SP-35 Pole)
Detail Survey
Tree cutting along the line including trimmimg, looping, branching etc as required
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, GI earth pipes etc.
Stringing of conductors
Erection of stay wires
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(A-2) Erection, Installation, Commissioning & Testing of Materials for Construction of 11/0.4 kV, 100KVA Distribution Transformer (Copper/Aluminium Wound) IS:1180 (part I) 2014 Amendment 4, conforming to BIS efficiency Level-2, table 3 Technical Specifications.
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, etc.
Erection, Installation, testing and commsissioning of 11/.4KV, 100 KVA Distribution Tranformers including Cables, LA, Gang Switch and DO Fuse alongwith all required accessories
Sub-Station Earthing; Earthing for DT and LA alongwith all required accessories
Erection of stay Set
Fencing of Sub-Station with welded Mesh Fencing including GI pipe as frame and post.
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(A-3) Erection, Installation, Commissioning & Testing of Materials for Construction of 11/0.4 kV, 63KVA Distribution Transformer (Copper/Aluminium Wound) IS:1180 (part I) 2014 Amendment 4, conforming to BIS efficiency Level-2, table 3 Technical Specifications.
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, etc.
Erection, Installation, testing and commsissioning of 11/.4KV, 100 KVA Distribution Tranformers including Cables, LA, Gang Switch and DO Fuse alongwith all required accessories
Sub-Station Earthing; Earthing for DT and LA alongwith all required accessories
Erection of stay Set
Fencing of Sub-Station with welded Mesh Fencing including GI pipe as frame and post.
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(A-4) Erection, Installation, Commissioning & Testing of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-70 Sq.mm on SP-11 Pole
Erection of poles including excavation of earth; fitting of Insulators & Accessories, Hardware fittings, etc.
Stringing of Cables ABC & Installation of all required accessories
Installation of Eye Hook/Eye Bolt, Insulating Piercing Connectors for Street Light, DB Charging and ABC to ABC TEE Connection
Installation of Anchor & Suspension Clamp
Installation of ASA Distribution box and Accessories
Installation of Pole clamp
Installation of Insulated Waterproof bimetallic lug Insulated Crimping type Midspan Joint
Erection of stay Set
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
( A-5 ) Erection, Installation, Commissioning & Testing of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-50 Sq.mm on SP-11 Pole
Erection of poles including excavation of earth; fitting of Insulators & Accessories, Hardware fittings, etc.
Stringing of Cables ABC & Installation of all required accessories
Installation of Eye Hook/Eye Bolt, Insulating Piercing Connectors for Street Light, DB Charging and ABC to ABC TEE Connection
Installation of Anchor & Suspension Clamp
Installation of ASA Distribution box and Accessories
Installation of Pole clamp
Installation of Insulated Waterproof bimetallic lug Insulated Crimping type Midspan Joint
Erection of stay Set
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
Description of Work / Item(s)
Amount
Taxes Applicable on Supply and Erection, Installation & Commissioning of Materials
Total GST on Supply of Materials (BoQ1)
Total GST on Erection, Installation & Commissioning (BoQ2)
Description of Work / Item(s)
Amount
TOTAL SCHEDULE NO. 1
Ex-works supply of materials (BoQ1)
TOTAL SCHEDULE NO. 2
Erection, Installation & Commissioning (BoQ2)
TOTAL SCHEDULE NO. 3
Taxes (BoQ3)
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid